{"title":"Research on meteorological impact factors of wind farm output power in plateau mountainous areas","authors":"Q. Fan, Xiankui Wen, Chenghui Lin, Yan Zhang","doi":"10.1109/ICPRE.2017.8390561","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390561","url":null,"abstract":"It is discussed the characteristics of wind resource, and is forced on researching the meteorological impact factors of wind farm output power in plateau mountain areas and in different terrain conditions. The thesis analyzes the influences of wind farm output power caused by meteorological impact factors in wind farm areas with the typical characteristics of plateau mountain areas. Finally, It is pointed out that the set of wind speed and wind direction is the minimum meteorological impact factor set of wind farm output power in plateau mountain areas.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126978015","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
X.T. Wan, Jie Ren, Tian Wan, Shi Jing, Sinian Xiong, Jiaxu Guo
{"title":"A control strategy of single phase voltage source PWM rectifier under rotating coordinate","authors":"X.T. Wan, Jie Ren, Tian Wan, Shi Jing, Sinian Xiong, Jiaxu Guo","doi":"10.1109/ICPRE.2017.8390520","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390520","url":null,"abstract":"Feed forward decoupling control under Rotating coordinate can suppress the static error of single-phase PWM rectifier's current. But due to the variation inductance in the actual situation, the performance of control will be poor. The feedforward decoupling control method without inductance value is adopted in this paper to solve the problem that the inductance value is not accurate. Simulink simulation results show that the control method can be completed when the L value is not accurate.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133311154","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"User-side load fast precise dispatching model based on contracts and direct load control","authors":"X. W. Wang, Y. Gong","doi":"10.1109/ICPRE.2017.8390633","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390633","url":null,"abstract":"In recent years, the whole society's electricity demand showed a sustained and rapid growth trend. Power supply is difficult to meet the demand. During load peak period in summer, the proportion of air conditioning load is as high as 30% ∼ 50% This kind of load will lead to further widening the peak-valley difference and bring hidden danger to operation of power grid. This paper first introduces the interaction between users, load aggregator and grid dispatch center. Then design contract details between user and load aggregator. Two dispatching models based on contracts and direct load control are put forward in this paper, which incorporates the electric excitation and electricity price response, to ensure safe and stable operation of power grid during peak period. On the basis of grid stable operation, achieving costs optimal. Finally, solving results show that the coordinated dispatching strategy we proposed could not only effectively reduce peak load of the system but fast and precisely dispatch loads when system faults occurs.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134047192","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on calling sequence of peaking regulation means in power system with pumped hydro power (PHP) station","authors":"Jinfang Zhang, Bo Yuan, Xiaochen Wang, Nan Li","doi":"10.1109/ICPRE.2017.8390594","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390594","url":null,"abstract":"In this paper, the pumped storage power station and other conventional power sources will be considered to participate in the peaking regulation of power system, and the adjustment order to obey has been studied. Based on the key concepts including continuous ramping events and unit capacity adjustment cost, an comprehensive cost optimization model for the adjustment order of different peaking-regulation measures is proposed, in which the characteristics of the system load ramping, pumped storage power station characteristics, all kinds of peak adjustment means cost have been taken into consideration. The example has shown that the method can effectively realize the sorting of many kinds of peaking regulation measures in the power system. It also has shown that the calling order of the pumped storage power station not always takes the first place as the conventional consideration, which is necessary to combine with the specific conditions of the system.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124260075","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Xue Hui, W. Qun, L. Yao, Zhang Yingbin, Shi Lei, Zhang Zhisheng
{"title":"Short-term load forecasting model based on deep neural network","authors":"Xue Hui, W. Qun, L. Yao, Zhang Yingbin, Shi Lei, Zhang Zhisheng","doi":"10.1109/ICPRE.2017.8390603","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390603","url":null,"abstract":"The short-term load forecasting model based on deep neural network is constructed in this paper. The forecasting model contains multiple hidden layers, which can extract the deep characteristics of the data. This allows the deep neural network to contain more information, extends the modeling ability of neural networks, and improves the predictive ability of the model. Genetic algorithm is used to optimize the weights and the thresholds of deep neural network. Using actual load data of electric power system for simulation test, compared with the conventional BP neural network, the test results show that the short-term load forecasting model based on deep neural network has good prediction effect.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125297028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Wang Jiaqiong, Wang Kai, Zhao Ruijie, T. Kai, D. Tao
{"title":"Research on eddy current loss of ‘Wet’ magnetic coupling","authors":"Wang Jiaqiong, Wang Kai, Zhao Ruijie, T. Kai, D. Tao","doi":"10.1109/ICPRE.2017.8390494","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390494","url":null,"abstract":"Eddy current loss of the magnetic coupling in fluid medium which named ‘wet’ situation is observed in this research. Numerical simulation of ANSYS is used to calculate and analyze eddy current loss in different fluid medium. The key equations of eddy current loss are based on the principle of magnetism. The model of ‘wet’ magnetic coupling is established to analyze the eddy current loss produced by magnetic coupling and isolation sleeve on the basis of finite element theory. Additionally, effect of rotational speed and conductivity on eddy current loss is analyzed in the study. Several methods to reduce eddy current loss are put forward incidentally.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"93 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131668115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mingfeng Xue, Kun Shi, Bin Yang, Xuejing Wang, Yi Sun, Bin Li
{"title":"Research on commerical mode for load optimizing via power grid and information network integration","authors":"Mingfeng Xue, Kun Shi, Bin Yang, Xuejing Wang, Yi Sun, Bin Li","doi":"10.1109/ICPRE.2017.8390601","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390601","url":null,"abstract":"In the context of the development of smart grid in China and the large number of residents, it is very likely that the power grid will face the problem of regional power failure and the problem of power imbalance at the peak of the load. Control can mitigate the dangers of an emergency. For this reason, this paper discusses the direct control strategy based on load aggregation, and evaluates and prospects the direct load control under power failure.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134417198","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jinhao Wang, Yanzhi Pang, Da Lei, Yonghai Xu, Mengmeng Zhang
{"title":"Harmonic assessments with multi-values considering the regulation effect","authors":"Jinhao Wang, Yanzhi Pang, Da Lei, Yonghai Xu, Mengmeng Zhang","doi":"10.1109/ICPRE.2017.8390498","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390498","url":null,"abstract":"The current method of harmonic evaluation is comparing the 95% value with the limit value based on GB/T 14549-93<Quality of electric energy supply harmonics in public supply network>, which can only judge whether the harmonic is exceeded or not. But it cannot evaluate the degree of harmonic pollution. Under the premise of ensuring the power quality of the utility grid as well as taking the different harmonic characteristics of the harmonic source users into account, it is necessary to refine the excessive degree of harmonics out of specification. And, the harmonics evaluation should link harmonic current assessment to harmonic voltage evaluation effectively to get a better assessment result. And a method of using multi-values maybe can be adopted. Therefore, a method of harmonic assessment with multi-values considering the regulation effect is proposed in this paper. The proposed method divides the harmonics influence on power grid into seven grades, which can give the reference to the harmonic mitigation both considering the cost of harmonic governance and the effect of the harmonic mitigation. The result of the case study proves the proposed method is effective and feasible to the harmonic assessment.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129090327","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Munir, Chuan Xie, Jianxiao Zou, Xiaodong Wang, S. Kashif, Talha Younas
{"title":"Imapct of VAr compensation on total harmonic distortion measured using smart meter","authors":"H. Munir, Chuan Xie, Jianxiao Zou, Xiaodong Wang, S. Kashif, Talha Younas","doi":"10.1109/ICPRE.2017.8390524","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390524","url":null,"abstract":"The widespread use of non-linear loads means the traditional meters fail to give accurate values of real power, reactive power and apparent power in the presence of high levels of distortion factors. This inevitably creates big difference between the actual and calculated/measured savings resulting from reactive power compensation. It has been investigated the impact of distortion factors on the determination of savings accrued from VAr compensation using both traditional and smart meters. Results in the paper clearly demonstrate the effect of VAR compensation on total harmonic distortion measured with smart meter.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"54 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133487269","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A novel convex combination of LMMN and RLS algorithms for power system parameter estimation","authors":"Gebeyehu Likassa, Haiquan Zhao","doi":"10.1109/ICPRE.2017.8390598","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390598","url":null,"abstract":"The ever growing usage of power electronic devices and non-linear loads in a power system is increasing current and voltage harmonics which are a major source of power quality deterioration. An essential step to mitigate the negative effects of harmonics is to design proper filtering which in turn requires an efficient parameter estimation of a measured power system signal. In this paper a novel convex combination of the least mean mixed norm (LMMN) and recursive least square (RLS) algorithms called RLMMN is proposed for harmonic, sub-harmonic and inter-harmonic amplitude and phase angle estimation of a distorted power system signal corrupted with a random Gaussian noise. The proposed RLMMN algorithm inherits the advantages of both algorithms to achieve fast convergence, better tracking and lower steady state estimation errors. The estimation performance is evaluated for static signal and abrupt amplitude drift condition. Three other algorithms reported in the literature are considered for judging the robustness of the proposed algorithm. From the simulation studies it is observed that the proposed RLMMN algorithm exhibits superior estimation performance in terms of estimation accuracy as compared to estimations obtained by LMS, RLS and LMMN algorithms under various SNR environments.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131754293","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}