2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)最新文献

筛选
英文 中文
Circumventing drug delivery problems in advanced pancreatic cancer treatment 规避晚期胰腺癌治疗中的药物输送问题
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117049
Lauren J Jablonowski, M. Wheatley
{"title":"Circumventing drug delivery problems in advanced pancreatic cancer treatment","authors":"Lauren J Jablonowski, M. Wheatley","doi":"10.1109/NEBEC.2015.7117049","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117049","url":null,"abstract":"This research aims to develop an injectable polymer-based platform to enable minimally-invasive targeted delivery of drug-loaded nano particles. Studies have shown that polymer-stabilized gas microbubbles are effective in enhancing an ultrasound image, especially those involving cancerous tumors. These contrast agents can serve a dual purpose when designed to encapsulate a drug within the shell, providing both diagnostic and therapeutic applications. The current gold standard treatment of non-resectable pancreatic ductal adenocarcinoma (PDA) is gemcitabine (GEM), which is administered systemically. However, response rates are low because the tumor environment inhibits the drug, especially the stroma surrounding the tumor. We hypothesize that GEM-loaded microbubbles injected intravenously will pass through the stroma and, when exposed to ultrasound (US), will burst to form nanoshards (n-Sh) which will lodge within the pancreatic tumor tissue, undergo sustained release of encapsulated GEM, and lead to cancer cell death through targeted therapy.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"126 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132869357","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of scaffold for use in osteochondral tissue engineering 骨软骨组织工程用支架的研制
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117085
G. Clay, S. Modha, P. Schomacker, J. A. Cooper
{"title":"Development of scaffold for use in osteochondral tissue engineering","authors":"G. Clay, S. Modha, P. Schomacker, J. A. Cooper","doi":"10.1109/NEBEC.2015.7117085","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117085","url":null,"abstract":"In this study, the bone component of a bi-phasic scaffold was developed and mechanically tested to compare it to that of subchondral bone properties. The bone component was composed of poly (ε-caprolactone):poly (ethylene oxide):sucrose (PCL:PEO:sucrose) that exhibited both pore size and porosity similar to that of cancellous bone, thereby providing a similar mechanical structure for the osteoblasts to differentiate and grow. The compressive Young's Modulus values ranged from 22.15 - 16.64 MPa, similar to that of literature values for subchondral bone [1]. Additionally, pore size was measured to be approximately 143 μm, based on SEM imaging. An initial cell study was done to confirm the cell viability of each of the components of the bi-phasic scaffold, independently. Future experiments will focus on developing and testing the complete bi-phasic scaffold through compression testing, as well as undergoing a cell study utilizing rat mesenchymal stem cells to observe the proliferation and differentiation within the bi-phasic scaffold for osteochondral tissue engineering.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124533907","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Segmentation of spinal cord in the pediatric spinal Diffusion Tensor MR Imaging 小儿脊髓弥散张量磁共振成像中的脊髓分割
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117146
M. Alizadeh, F. Mohamed, S. Faro, P. Shah, D. Middleton, C. Conklin, M. Mulcahey
{"title":"Segmentation of spinal cord in the pediatric spinal Diffusion Tensor MR Imaging","authors":"M. Alizadeh, F. Mohamed, S. Faro, P. Shah, D. Middleton, C. Conklin, M. Mulcahey","doi":"10.1109/NEBEC.2015.7117146","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117146","url":null,"abstract":"Classification and segmentation of small structures such as spinal cord is extremely challenging. In this paper, a multi stage segmentation algorithm is proposed and tested to accurately and reliably segment the spinal canal and spinal cord from the background in the pediatric spinal Diffusion Tensor MR images. First, median filter and image compression methods were applied to mitigate the amplitude of the noise and improve the homogeneity of the image. Next, mathematical morphological processing was applied to segment and label the regions attributed to the spinal canal. These segmented regions were classified into the spinal canal and background using a Euclidean metric obtained by centroid coordinates of segmented regions in the volumetric DTI data. Finally, Otsu thresholding technique was applied to extract cord region from spinal canal. Segmentation accuracy, sensitivity, specificity and spatial overlap index were examined as performance measurements. The quantitative measurements represent the effectiveness of the proposed method.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128746807","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Bubble raft-an optical phantom for analyzing artifacts in OCT imaging of lung 气泡筏——用于分析肺部OCT成像伪影的光学幻影
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117200
Hanlin Tang, A. Gouldstone, C. DiMarzio
{"title":"Bubble raft-an optical phantom for analyzing artifacts in OCT imaging of lung","authors":"Hanlin Tang, A. Gouldstone, C. DiMarzio","doi":"10.1109/NEBEC.2015.7117200","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117200","url":null,"abstract":"Accurate measurement of alveolar volume by lung imaging is crucial to study and understand respiratory mechanics. Optical Coherence Tomography (OCT), which generates cross-sectional microscopic image of tissue structure in real time based on near-infrared interferometry, can image several layers of distal alveoli in intact, ex vivo lung tissue. However, optical effects associated with heterogeneity of lung tissue results in incorrect alveoli shape imaging and inaccurate assessment of lung volume. Due to the irregular cellular shape of lung tissue and the lack of ground truth, these errors are difficult to analyze, as well as remove. To address this, the Bragg-Nye bubble raft, a two-dimensional crystalline arrangement of elements similar in geometry to alveoli has been adapted as an inflated lung phantom to study and analyze these errors.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128689197","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Methods for analysis of hemodynamic and metabolic risks factors in hypertension 高血压血流动力学及代谢危险因素分析方法
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117181
Priya Mohan, Timothy S. Phan, J. Li
{"title":"Methods for analysis of hemodynamic and metabolic risks factors in hypertension","authors":"Priya Mohan, Timothy S. Phan, J. Li","doi":"10.1109/NEBEC.2015.7117181","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117181","url":null,"abstract":"Hypertension has its contribution from atherosclerosis or metabolic factors. It is commonly diagnosed with a sphygmomanometer (blood pressure cuff) which only outputs systolic (Ps) and diastolic (Pd) pressures. Hypertensive patients are then administered oral medication whose effect on arterial compliance (C), an index of vascular stiffness, cannot be accurately determined merely from Ps and Pd values. The underlying blood pressure waveforms are normally obtained clinically through catheterization. Vascular stiffness index (VSI) can then be computed from pulse waveform analysis (PWA). However, there are controversies as to whether a constant single-valued C alone is sufficient for assessing VSI. We investigated the time-varying, pressure-dependent characteristics of arterial compliance (C(P)) with a nonlinear model of the arterial system during normal, induced hypertension and vasodilator-treated conditions. Results show that C(P) differs from constant compliance C and that C(P) can rapidly reflect underlying beat-to-beat variations in arterial compliance and can effectively serve as a reliable index of VSI. It can be used for accurate evaluation of the efficacy of blood pressure altering drugs.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127230561","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Quantitative study on effects of baclofen on muscle spasticity in Multiple Sclerosis 巴氯芬对多发性硬化症肌肉痉挛影响的定量研究
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117076
T. Alter, W. Craelius, M. Wininger, M. Wallin, M. Moradi
{"title":"Quantitative study on effects of baclofen on muscle spasticity in Multiple Sclerosis","authors":"T. Alter, W. Craelius, M. Wininger, M. Wallin, M. Moradi","doi":"10.1109/NEBEC.2015.7117076","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117076","url":null,"abstract":"Spasticity is clinically defined as velocity-dependent resistance to passive movement, characterized by excessive, jerky contraction of muscles. However, spasticity is not yet well understood, and current clinical measures of it are subjective and unreliable. We applied standard physics principles and phase space analyses to better visualize the motor impairments associated with spasticity in Multiple Sclerosis patients, at the VA Hospital in Washington, DC. Testing was conducted at baseline and then again after one month of de novo baclofen administration in order to determine whether this improved the patients' condition. Two analytical methods were used: (1) Phase Area Ratio (PAR) and (2) Spontaneous Accelerative Transients (SAT). The SAT analyses showed a small decrease in spasticity after baclofen use, while the PAR analyses and clinical measures showed no significant change. Although they provided differing results, this study shows that spasticity during active joint motions can be more reliably quantified through analytical methods. The PAR and SAT metrics may be applicable to a variety of physiological signals.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130207222","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Lachman's ACL test: A multibody simulation 拉赫曼前交叉韧带测试:多体模拟
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117159
J. Felice, M. Sebald, D. Piovesan, S. Bitticker
{"title":"Lachman's ACL test: A multibody simulation","authors":"J. Felice, M. Sebald, D. Piovesan, S. Bitticker","doi":"10.1109/NEBEC.2015.7117159","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117159","url":null,"abstract":"Diagnosing a torn Anterior Cruciate Ligament (ACL) of the knee is a difficult task which is usually performed by physical therapist using physical manipulation of the knee. To help training physical therapy students recognizing the difference between an intact and torn ACL this work proposes a simplified physical model to be fabricated. The model is proposed to replicate the Lachman's test which measures the anteroposterior displacement between the femur and the tibia in a specific knee configuration. In preparation for fabrication a set of in-silico experiments were performed using SimWise software. Including the ACL constraint in the simulation provided a forward displacement of 7.29mm between femur and tibia. Simulations without the ACL produced a displacement of 12.65mm. These results are in agreement with the literature and provide a solid theoretical basis for the fabrication of the physical prototype.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125501559","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Synthetic micro-scale habitats emulating microbial system function 模拟微生物系统功能的合成微尺度生境
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117046
L. Shor
{"title":"Synthetic micro-scale habitats emulating microbial system function","authors":"L. Shor","doi":"10.1109/NEBEC.2015.7117046","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117046","url":null,"abstract":"Summary form only given. Micro-scale habitat conditions control the composition and function of microbial communities. For example, the paunch of the eastern subterranean termite has a physical volume of just one microliter, yet is home to a complex community of bacteria, protists, archaea and fungi. Within the termite gut, steep gradients provide spatially-distinct microniches, while close proximity allows a metabolically diverse community to collaboratively convert a lignocellulosic feedstock into acetate and other useful products. Likewise, the function of the soil system emerges from the interactions of diverse microbes with various micro-structured habitats. Conventional bioengineering approaches cannot systematically replicate micro-scale features of real microbial habitats, and as a result, may fail to capture the complex or emergent properties of microbe-habitat systems. The Shor lab is developing synthetic micro-scale habitats with micro-scale physical structures, chemical gradients, and patchy microbial distributions characteristic of real microbe-habitat systems. Our synthetic micro-scale habitats are designed to implement advanced sensing, electro-chemical actuators, and molecular tools. We have shown microbially-secreted extracellular polymeric substances can regulate retention of soil moisture, but only in micro-structured settings. We have used microdevices with synthetic pore structures to accelerate the development of sustainable food production technology. Moving forward, there is a tremendous potential for engineered bio-physical systems to broaden the scope and accelerate the pace of bioengineering discovery. Applications include sustainable food and fuel production and better approaches to safeguard the environment and human health.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121327087","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Data-driven modeling of arterial wave propagation using non-invasive arterial pulse waveforms 利用非侵入性动脉脉冲波形进行动脉波传播的数据驱动建模
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117065
Z. Ghasemi, Jongchan Lee, Chang-Sei Kim, Hao-min Cheng, R. Mukkamala, J. Hahn
{"title":"Data-driven modeling of arterial wave propagation using non-invasive arterial pulse waveforms","authors":"Z. Ghasemi, Jongchan Lee, Chang-Sei Kim, Hao-min Cheng, R. Mukkamala, J. Hahn","doi":"10.1109/NEBEC.2015.7117065","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117065","url":null,"abstract":"This study investigates the validity of two non-invasive arterial pulse waveforms as viable indirect surrogates of arterial blood pressure waveforms, by conducting a data-driven modeling analysis of arterial wave propagation. Using the so-called “tube-load” model, we examined how well the relation between carotid versus femoral tonometry waveforms as well as carotid tonometry versus ankle pulse volume recording waveforms can be fitted to the model. Since the tube-load model describes the relationship between proximal versus distal blood pressures, we hypothesized that viable surrogates of blood pressure waveforms must be fitted well by the tube-load model. Preliminary results derived from 4 subjects with cardiovascular diseases indicated that carotid and femoral tonometry waveforms may serve as viable surrogate of arterial BP waveforms while PVR may need additional treatment, which was attributed to the nature of PVR waveforms: they are volume waveforms but not pressure waveforms.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124931805","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A wireless sensing system for continuous monitoring of intracompartmental pressures 一种连续监测室内压力的无线传感系统
2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC) Pub Date : 2015-04-17 DOI: 10.1109/NEBEC.2015.7117098
James Z. Jackson, Matthew K. Dion, John F. Drazan, David A. Forsh, N. Cady, E. Ledet
{"title":"A wireless sensing system for continuous monitoring of intracompartmental pressures","authors":"James Z. Jackson, Matthew K. Dion, John F. Drazan, David A. Forsh, N. Cady, E. Ledet","doi":"10.1109/NEBEC.2015.7117098","DOIUrl":"https://doi.org/10.1109/NEBEC.2015.7117098","url":null,"abstract":"Acute compartment syndrome (ACS) is a true orthopaedic emergency. The potential sequelae of an undiagnosed ACS include muscle necrosis, contracture, and in some cases amputation. We have developed a simple, wireless, passively-powered sensor that has the potential to provide continuous monitoring of intracompartmental pressure in vivo. This will allow clinicians to make an early diagnosis of ACS which is essential to preventing sequelae and unnecessary fasciotomies.","PeriodicalId":111398,"journal":{"name":"2015 41st Annual Northeast Biomedical Engineering Conference (NEBEC)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121370295","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书