Jean-Claude Imber, Azita Khandanpour, Andrea Roccuzzo, Delia R. Irani, Dieter D. Bosshardt, Anton Sculean, Benjamin E. Pippenger
{"title":"Comparative osseointegration of hydrophobic tissue-level tapered implants—A preclinical in vivo study","authors":"Jean-Claude Imber, Azita Khandanpour, Andrea Roccuzzo, Delia R. Irani, Dieter D. Bosshardt, Anton Sculean, Benjamin E. Pippenger","doi":"10.1111/clr.14318","DOIUrl":"10.1111/clr.14318","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Purpose</h3>\u0000 \u0000 <p>To histometrically compare the osseointegration and crestal bone healing of a novel tapered, self-cutting tissue-level test implant with a standard tissue-level control implant in a submerged healing regimen.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Materials and Methods</h3>\u0000 \u0000 <p>In a mandibular minipig model, implants were inserted and evaluated histometrically after a healing period of 3, 6, and 12 weeks. The primary outcome was the evaluation of bone-to-implant contact (BIC) and secondary outcomes were primary stability as per insertion torque and first BIC (fBIC). Outcomes for the test and control implants were compared using Wilcoxon signed-rank tests and mixed linear regression models.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>Insertion torque values were significantly higher for the test (50.0 ± 26.4 Ncm) compared to the control implants (35.2 ± 19.7 Ncm, <i>p</i> = .0071). BIC values of test implants were non-inferior to those of control implants over the investigated study period. After 12 weeks, the corresponding values measured were 81.62 ± 11.12% and 90.41 ± 4.81% (<i>p</i> = .1763) for test and control implants, respectively. Similarly, no statistical difference was found for fBIC values, except for the 12 weeks outcome that showed statistically lower values for the test (−675.58 ± 590.88 μm) compared to control implants (−182.75 ± 197.40 μm, <i>p =</i> .0068).</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusions</h3>\u0000 \u0000 <p>Novel self-cutting tissue-level implants demonstrated noninferior osseointegration and crestal bone height maintenance to the tissue-level implants. Histometric outcomes between both implants demonstrated test implants were statistically noninferior to control implants, despite substantial differences in the bone engagement mechanism and resulting differences in insertion torque and qualitative bone healing patterns.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 10","pages":"1299-1309"},"PeriodicalIF":4.8,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14318","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141730518","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Leonardo Trombelli, Roberto Farina, Cristiano Tomasi, Fabio Vignoletti, Guerino Paolantoni, Francesco Giordano, Luca Ortensi, Anna Simonelli
{"title":"Factors affecting radiographic marginal bone resorption at dental implants in function for at least 5 years: A multicenter retrospective study","authors":"Leonardo Trombelli, Roberto Farina, Cristiano Tomasi, Fabio Vignoletti, Guerino Paolantoni, Francesco Giordano, Luca Ortensi, Anna Simonelli","doi":"10.1111/clr.14327","DOIUrl":"10.1111/clr.14327","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Objective</h3>\u0000 \u0000 <p>To evaluate the influence of patient and implant-related factors on the changes of marginal bone levels (MBL) at implants with a follow-up ≥5 years.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Materials and Methods</h3>\u0000 \u0000 <p>At baseline (within 6 months from prosthetic insertion) and long-term (≥5 years after implant placement) visits, interproximal (mesial and distal) MBL were radiographically evaluated. To analyze factors predicting MBL change, the site (either mesial or distal) showing the highest MBL change (hChMBL site) was identified for each implant. Multilevel regression models were built to explain MBL change as well as the probability for a bone loss ≥2 mm at long-term.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>942 implants in 312 patients with a mean follow-up of 8.02 ± 2.5 years were analyzed. MBL change was significantly predicted by baseline MBL, oral bisphosphonate (BP) intake, history of periodontitis, diabetes, and super-hydrophilic implant surface. Higher risk for a bone loss ≥2 mm was observed in patients with history of periodontitis (OR = 9.52, 95% CI 0.72–3.79) and taking BP (OR = 6.84, 95% CI 0.21–3.63). Mandibular implants had higher odds for bone loss ≥2 mm compared to maxillary implants (OR = 3, 95% CI 0.39–1.87).</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusions</h3>\u0000 \u0000 <p>The findings of the present study contribute to the identification of specific clinical scenarios at higher risk for implant-supporting bone loss that need to be strictly monitored during maintenance.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 11","pages":"1406-1417"},"PeriodicalIF":4.8,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14327","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141616024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Laurits Kaaber, Louise Hauge Matzen, Rubens Spin-Neto, Lars Schropp
{"title":"Low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens","authors":"Laurits Kaaber, Louise Hauge Matzen, Rubens Spin-Neto, Lars Schropp","doi":"10.1111/clr.14326","DOIUrl":"10.1111/clr.14326","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Aim</h3>\u0000 \u0000 <p>To evaluate the performance of low-dose cone beam computed tomography (CBCT) protocols with regard to linear bone measurements in the posterior mandible for implant planning compared with higher dose protocols.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Materials and Methods</h3>\u0000 \u0000 <p>Forty-two edentulous posterior sites in human cadaveric mandibles were imaged in three CBCT scanners using three or four protocols with varying exposure parameters to achieve lower dose. Co-registration was performed to generate sagittal and cross-sectional image sections representative of the implant site. Three observers measured bone height, from the alveolar crest to the mandibular canal, and width, three mm from the top of the alveolar crest. Intra- and interobserver reproducibility were assessed for the cases rated as <i>nonmeasurable</i> as well as for completed measurements. The measurements were analyzed using paired <i>t</i>-tests for differences among the CBCT protocols and the frequency distribution of nonmeasurable cases with a Pearson Chi-square test.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>Reproducibility for registering nonmeasurable cases varied among observers; however, no consistent significant differences were found in the frequency distribution of these cases among observers, units, and protocols. Intraclass correlation coefficients (ICC) were >0.9 for all measurements of bone height and width. Mean differences of <0.5 mm were found regardless of protocol; however, one observer did in some cases produce larger differences.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusion</h3>\u0000 \u0000 <p>Linear bone measurements did not differ significantly and could be performed with excellent reliability, using low-dose CBCT protocols compared with standard and high-resolution ones. Varying approaches for rating nonmeasurable cases were found, indicating differences in diagnostic strategies related to implant planning among observers.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 11","pages":"1394-1405"},"PeriodicalIF":4.8,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14326","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141544617","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of depression and the antidepressant fluoxetine on osseointegration—A pre-clinical in vivo experimental study","authors":"Yundeng Xiaowen, Jingxuan Zhu, Mingming Gong, Ge Meng, Renran Tan, Yanbing Zhang, Zhiyu Chen","doi":"10.1111/clr.14323","DOIUrl":"10.1111/clr.14323","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Objective</h3>\u0000 \u0000 <p>The aim of this study was to explore the effect of depression and selective serotonin reuptake inhibitors on implant osseointegration and bone healing.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Methods</h3>\u0000 \u0000 <p>Forty-eight 6- to 8-week-old SPF Sprague–Dawley male rats were randomly divided into four groups: the Control group, the Fluoxetine group, the Depression group and the De&Flu group. The rats in the Depression group and the De&Flu group were subjected to a depression modelling process, and the rats in the Control group and the Fluoxetine group were raised normally. Then, a titanium implant was placed in the right tibia of each rat. In the Fluoxetine group and De&Flu group, fluoxetine was injected subcutaneously daily, while subcutaneously injecting physiological saline in the Control group and Depression group. Collecting serum from the rats used for ELISA. The surgical area was cut for microcomputed tomography and histology observation.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>After 12 weeks, bone mineral density was lower in the De&Flu group than in the Control group, Depression group and Fluoxetine group. Bone mineral density was also lower in the Depression group and the Fluoxetine group than in the Control group. The percentage of bone–implant contact (BIC%) in De&Flu rats was lower than in the Control, Depression and Fluoxetine groups. The BIC% in the Depression group and the Fluoxetine group was lower than in the Control group.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusions</h3>\u0000 \u0000 <p>Depression and fluoxetine negatively affect bone density and implant osseointegration independently, and this damaging effect is exacerbated when both factors are present. The mechanism may be related to the dysregulation of the hypothalamic–pituitary–adrenal axis and inflammation in the body.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 10","pages":"1355-1366"},"PeriodicalIF":4.8,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141497333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Daniel Thoma, Alfonso Gil, Thomas de Bruyckere, Ronald E. Jung, Shunsuke Fukuba, Axelle Ickroth, Franz J. Strauss, Jan Cosyn
{"title":"Early implant placement versus ridge preservation and delayed implant placement: Analysis of profilometric, clinician- and patient-reported outcomes from a two-centre RCT","authors":"Daniel Thoma, Alfonso Gil, Thomas de Bruyckere, Ronald E. Jung, Shunsuke Fukuba, Axelle Ickroth, Franz J. Strauss, Jan Cosyn","doi":"10.1111/clr.14325","DOIUrl":"10.1111/clr.14325","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Objectives</h3>\u0000 \u0000 <p>To compare early implant placement (EP) to alveolar ridge preservation and delayed implant placement (ARP/DP) in terms of contour changes, along with clinician- and patient-reported outcome measures (PROMs) until the delivery of the implant-supported restoration.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Materials and Methods</h3>\u0000 \u0000 <p>Patients with a failing single tooth in the maxilla or mandible were recruited in two centres. After tooth extraction, patients were randomly assigned (1:1) to either EP or ARP/DP. At abutment connection and crown delivery, the buccal contour changes at 3 mm below the mucosal margin (primary outcome) along with clinician- (ease of treatment) and patient-reported outcomes were assessed using numeric rating scales and OHIP-14.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>A total of 46 patients were analysed. The mean buccal contour at abutment connection decreased by −1.2 ± 0.6 mm in group EP and −1.6 ± 0.8 mm in group ARP/DP (estimated mean difference; 0.45 [95%CI, −0.02; 0.94]; <i>p</i> = .061) with no significant differences between the groups. ARP/DP was consistently easier than EP across all stages of the surgery (estimated mean difference; 2.0 [95%CI, 1.3; 2.7] <i>p</i> < .001): during flap elevation (EP: 4.8 vs. ARP/DP: 1.6), implant placement (EP: 5.7 vs. ARP/DP: 2.2) and wound closure (EP: 3.4 vs. ARP/DP: 1.6). Both interventions improved quality of life but patients who underwent ARP/DP were significantly more satisfied at the time of crown delivery (ARP/DP: 9.6 vs. EP: 9.1, <i>p</i> = .02).</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusions</h3>\u0000 \u0000 <p>EP and ARP/DP show no significant differences in buccal contour changes, aesthetics and patient-reported outcomes. However, ARP/DP is an easier procedure at all stages of the surgery compared to EP and could therefore be the preferred therapy for less experienced clinicians.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 11","pages":"1382-1393"},"PeriodicalIF":4.8,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14325","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141497332","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"RETRACTION: Ultrastructural study by backscattered electron imaging and elemental microanalysis of biomaterial-to-bone interface and mineral degradation of bovine xenografts in maxillary sinus floor elevation","authors":"","doi":"10.1111/clr.14305","DOIUrl":"10.1111/clr.14305","url":null,"abstract":"<p>M. P. Ramírez-Fernández, J. L. Calvo-Guirado, R. A. Delgado-Ruiz, J. E. Maté-Sánchez del Val, B. Negri, M. Peñarrocha Diago, “Ultrastructural study by backscattered electron imaging and elemental microanalysis of biomaterial-to-bone interface and mineral degradation of bovine xenografts in maxillary sinus floor elevation,” <i>Clinical Oral Implants Research</i> 24, no. 6 (2013): 645–651, https://doi.org/10.1111/j.1600-0501.2012.02439.x.</p><p>The above article, published online on 16 March 2012 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the journal Editor-in-Chief, Lisa J. A. Heitz-Mayfield; and John Wiley & Sons Ltd. The retraction has been agreed due to concerns raised by third parties on the data presented in the article. Several flaws and inconsistencies between results presented and experimental methods described were found. Specifically, instances of overlapping data within the article and with another publication authored by the same group have been found, despite the articles have different study designs. Accordingly, the editors consider the findings of this article unreliable and the conclusions to be invalid. The authors have been informed of the decision to retract the article. The corresponding author M. P. Ramírez-Fernández and co-author R. A. Delgado-Ruiz disagree with the decision of retraction. The remaining co-authors were not available for a final confirmation of the retraction.</p>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 9","pages":"1201"},"PeriodicalIF":4.8,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14305","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141476109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Long-term retention and survival of cemented implant-supported zirconia and metal-ceramic single crowns: A retrospective study","authors":"P. Rammelsberg, A. L. Klotz","doi":"10.1111/clr.14321","DOIUrl":"10.1111/clr.14321","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Objectives</h3>\u0000 \u0000 <p>To evaluate the effect of different cement types on the incidence of failure and loss of retention of zirconia and metal-ceramic single crowns (SCs) cemented on implant abutments.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Methods</h3>\u0000 \u0000 <p>We placed 567 implant-supported SCs in 358 patients and retrospectively evaluated long-term retention for up to 12.8 years. The frameworks were made from metal alloy (<i>n</i> = 307) or zirconia (<i>n</i> = 260). SCs were cemented with permanent (glass-ionomer cement; <i>n</i> = 376) or semipermanent cement (zinc oxide non-eugenol cement; <i>n</i> = 191) on standardized (<i>n</i> = 446) or customized (<i>n</i> = 121) abutments. Kaplan–Meier curves were used to calculate the incidence of decementation. Differences between survival curves were assessed with log-rank tests. Cox-regression analysis was performed to evaluate multiple risk factors.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>Of the 567 SCs, 22 failed because of technical complications and four because of implant loss. Loss of retention was observed in 50 SCs. Analysis revealed a 7% probability of loss of retention for zirconia and 16% for metal-ceramic SCs after 10 years (<i>p</i> = .011). After 5 years, loss of retention was higher for standardized abutments than for customized abutments (<i>p</i> = .014). The probability of loss of retention was higher with semipermanent than with permanent cement (<i>p</i> = .001). Cox-regression analysis revealed semipermanent cement as the only significant risk factor for SC failure (<i>p</i> = .026).</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusions</h3>\u0000 \u0000 <p>In contrast to semipermanent cement, permanent cement provides acceptable long-term retention of cemented implant-supported SCs. These possible positive effects of customized abutments have to be controlled with larger sample sizes.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 10","pages":"1335-1342"},"PeriodicalIF":4.8,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14321","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141491149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Vinay V. Kumar, Supriya Ebenezer, Sreelakshmi Viswanath, Andreas Thor
{"title":"One-stage prosthodontically driven jaw reconstruction in patients with benign and malignant pathologies: A 7- to 11-year cohort study","authors":"Vinay V. Kumar, Supriya Ebenezer, Sreelakshmi Viswanath, Andreas Thor","doi":"10.1111/clr.14322","DOIUrl":"10.1111/clr.14322","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Objectives</h3>\u0000 \u0000 <p>One stage functional jaw reconstruction is defined as the resection and reconstruction of segmental defects in conjunction with the placement of dental implants in an ideal prosthetic position and loaded with a provisional restoration, during one surgical procedure. The aim of the study is to describe clinical outcomes of patients who underwent one stage functional jaw reconstruction.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Methods</h3>\u0000 \u0000 <p>Patients who underwent one-stage functional jaw reconstruction, from January 2013 to March 2016 were recalled in 2022 and 2023. Planning and execution for the reconstruction utilized either analogue or digital techniques. Outcome parameters recorded were treatment-related outcomes at patient level, implant-related outcomes and patient-reported outcome measures.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>Eighteen patients underwent one-stage jaw reconstruction with a total of 57 implants. Four patients had maxillary and 14 had mandibular reconstructions. Ten patients underwent postoperative radiotherapy. Ten patients were planned using analogue and eight by digital planning. Three patients had partial flap necrosis, three patients had plate fractures, implant loss was seen in one patient and four patients died during the period. A functional prosthesis was provided in 16 out of the 18 patients.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusion</h3>\u0000 \u0000 <p>One-stage functional jaw reconstruction is a predictable method for providing rehabilitation with successful outcomes at 7–11 years. However, caution should be exercised when the treatment modality is carried out in patients with malignant pathologies who have undergone radiotherapy.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 10","pages":"1343-1354"},"PeriodicalIF":4.8,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14322","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141491150","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"RETRACTION: Ultrastructural study by backscattered electron imaging and elemental microanalysis of bone-to-biomaterial interface and mineral degradation of porcine xenografts used in maxillary sinus floor elevation","authors":"","doi":"10.1111/clr.14304","DOIUrl":"10.1111/clr.14304","url":null,"abstract":"<p>M. P. Ramírez-Fernández, J. L. Calvo-Guirado, J. E. Maté-Sánchez del Val, R. A. Delgado-Ruiz, B. Negri, C. Barona-Dorado, “Ultrastructural study by backscattered electron imaging and elemental microanalysis of bone-to-biomaterial interface and mineral degradation of porcine xenografts used in maxillary sinus floor elevation,” <i>Clinical Oral Implants Research</i> 24, no. 5 (2013): 523–530, https://doi.org/10.1111/j.1600-0501.2011.02414.x.</p><p>The above article, published online on 26 January 2012 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the journal Editor-in-Chief, Lisa J. A. Heitz-Mayfield; and John Wiley & Sons Ltd. The retraction has been agreed due to concerns raised by third parties on the data presented in the article. Several flaws and inconsistencies between results presented and experimental methods described were found. Specifically, instances of overlapping data within the article and with another publication authored by the same group have been found, despite the articles have different study designs. Accordingly, the editors consider the findings of this article unreliable and the conclusions to be invalid. The authors have been informed of the decision to retract the article. The corresponding author M. P. Ramírez-Fernández and co-author R. A. Delgado-Ruiz disagree with the decision of retraction. The remaining co-authors were not available for a final confirmation of the retraction.</p>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 9","pages":"1200"},"PeriodicalIF":4.8,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14304","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141476110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Young Woo Song, Jin-Young Park, Ji-Yeong Na, Yoon-Hee Kwon, Jae-Kook Cha, Ui-Won Jung, Daniel S. Thoma, Ronald E. Jung
{"title":"Does an untreated peri-implant dehiscence defect affect the progression of peri-implantitis?: A preclinical in vivo experimental study","authors":"Young Woo Song, Jin-Young Park, Ji-Yeong Na, Yoon-Hee Kwon, Jae-Kook Cha, Ui-Won Jung, Daniel S. Thoma, Ronald E. Jung","doi":"10.1111/clr.14324","DOIUrl":"10.1111/clr.14324","url":null,"abstract":"<div>\u0000 \u0000 \u0000 <section>\u0000 \u0000 <h3> Objective</h3>\u0000 \u0000 <p>To investigate the early impact of plaque accumulation in a buccal dehiscence defect on peri-implant marginal bone resorption.</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Materials and Methods</h3>\u0000 \u0000 <p>In six male Mongrel dogs, four dental implants were placed in the posterior maxilla on both sides (two implants per side). Based on the group allocation, each implant was randomly assigned to one of the following four groups to decide whether buccal dehiscence defect was prepared and whether silk ligation was applied at 8 weeks post-implant placement for peri-implantitis induction: UC (no defect without ligation); UD (defect without ligation); LC (no defect with ligation); and LD (defect with ligation) groups. Eight weeks after disease induction, the outcomes from radiographic and histologic analyses were statistically analyzed (<i>p</i> < .05).</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Results</h3>\u0000 \u0000 <p>Based on radiographs, the exposed area of implant threads was smallest in group UC (<i>p</i> < .0083). Based on histology, both the distances from the implant platform to the first bone-to-implant contact point and to the bone crest were significantly longer in the LD group (<i>p</i> < .0083). In the UD group, some spontaneous bone fill occurred from the base of the defect at 8 weeks after implant placement. The apical extension of inflammatory cell infiltrate was significantly more prominent in the LD and LC groups compared to the UC group (<i>p</i> < .0083).</p>\u0000 </section>\u0000 \u0000 <section>\u0000 \u0000 <h3> Conclusion</h3>\u0000 \u0000 <p>Plaque accumulated on the exposed implant surface had a negative impact on maintaining the peri-implant marginal bone level, especially when there was a dehiscence defect around the implant.</p>\u0000 </section>\u0000 </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 11","pages":"1373-1381"},"PeriodicalIF":4.8,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14324","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141466637","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}