Laboratory Robotics and Automation最新文献

筛选
英文 中文
Editorial notes 社论指出
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<185::AID-LRA1>3.0.CO;2-T
W. Jeffrey Hurst
{"title":"Editorial notes","authors":"W. Jeffrey Hurst","doi":"10.1002/(SICI)1098-2728(1999)11:4<185::AID-LRA1>3.0.CO;2-T","DOIUrl":"https://doi.org/10.1002/(SICI)1098-2728(1999)11:4<185::AID-LRA1>3.0.CO;2-T","url":null,"abstract":"","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"185"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<185::AID-LRA1>3.0.CO;2-T","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"137740701","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Further development of a versatile microscale automated workstation for parallel adaptive experimentation 用于并行自适应实验的多用途微型自动化工作站的进一步开发
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<217::AID-LRA6>3.0.CO;2-C
David G. Cork, Tohru Sugawara, Jonathan S. Lindsey, L. Andrew Corkan, Hai Du
{"title":"Further development of a versatile microscale automated workstation for parallel adaptive experimentation","authors":"David G. Cork,&nbsp;Tohru Sugawara,&nbsp;Jonathan S. Lindsey,&nbsp;L. Andrew Corkan,&nbsp;Hai Du","doi":"10.1002/(SICI)1098-2728(1999)11:4<217::AID-LRA6>3.0.CO;2-C","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:4<217::AID-LRA6>3.0.CO;2-C","url":null,"abstract":"<p>We have further developed our microscale automated chemistry workstation for investigating the optimization of reaction conditions. The workstation includes a Cartesian robot for solvent delivery and reagent/sample handling, a 60-vessel reaction block, a UV–Vis absorption spectrometer, and vial racks for compound storage. This article describes the following hardware additions that increase the scope and versatility of the workstation: (a) an analytical high performance liquid chromatography (HPLC) instrument and accompanying hardware interface (slide rail, autosampler); (b) three reactor blocks of 20 vessels each, with independent temperature control of each reactor block between ca. 0 and 80°C; (c) a shaker rack for mixing, dilution, or extraction of samples; (d) a rotary valve on the dispense line for complete isolation of 4 independent solvent lines; (e) sample workup features using disposable cartridges or filters; (f) provisions for dispensing inert gas, for example, for flushing through reactors or for storing solvents and performing transfer/dispense operations under. Using the new features, we are able to obtain useful analytical data from a wider range of reaction mixtures, perform parallel reactions at different temperatures, and handle solvents and sensitive reagents. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 217–223, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"217-223"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<217::AID-LRA6>3.0.CO;2-C","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73336534","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Solid-liquid extraction behavior of trivalent rare earths by tributyl phosphate at high temperatures 磷酸三丁酯高温固液萃取三价稀土的行为
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<229::AID-LRA8>3.0.CO;2-%23
Su Zhao, Wu Yang, Jinzhang Gao
{"title":"Solid-liquid extraction behavior of trivalent rare earths by tributyl phosphate at high temperatures","authors":"Su Zhao,&nbsp;Wu Yang,&nbsp;Jinzhang Gao","doi":"10.1002/(SICI)1098-2728(1999)11:4<229::AID-LRA8>3.0.CO;2-%23","DOIUrl":"https://doi.org/10.1002/(SICI)1098-2728(1999)11:4<229::AID-LRA8>3.0.CO;2-%23","url":null,"abstract":"<p>Solid–liquid extraction behaviors of trivalent rare earths (La–Lu, Y) from ammonium thiocyanate solution by tributyl phosphate using molten paraffin wax as diluent were studied and optimum extraction conditions were determined. In 10 mL of aqueous RE<sup>3+</sup> solution where C<sub>RE(III)</sub> = 4.0 × 10<sup>−3</sup> mol·L<sup>−1</sup>, when additions of tributyl phosphate and ammonium thiocyanate are 5.00 mL and 2.80 g, respectively, extraction distribution ratios are over 10. The procedure can be used for rapid extraction separation of rare earths. An extraction mechanism was also investigated, and the complex species extracted into organic phase is RE(TBP)(SCN)(NO<sub>3</sub>)<sub>2</sub>. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 229–233, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"229-233"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"137739812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Use of FIA systems for on-line dilution in multielement determination by ICP–MS ICP-MS中在线稀释FIA系统的应用
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<240::AID-LRA10>3.0.CO;2-6
José Anchieta Gomes Neto, José Bento Borba Silva, Ivan Gonçalves Souza, Adilson José Curtius
{"title":"Use of FIA systems for on-line dilution in multielement determination by ICP–MS","authors":"José Anchieta Gomes Neto,&nbsp;José Bento Borba Silva,&nbsp;Ivan Gonçalves Souza,&nbsp;Adilson José Curtius","doi":"10.1002/(SICI)1098-2728(1999)11:4<240::AID-LRA10>3.0.CO;2-6","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:4<240::AID-LRA10>3.0.CO;2-6","url":null,"abstract":"<p>A flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma–mass spectrometry (ICP–MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume into a spray chamber through a standard Meinhard nebulizer of an ICP–MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) &lt; 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 240–247, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"240-247"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<240::AID-LRA10>3.0.CO;2-6","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86507634","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
On-line analysis of NH3, CO2, and SO2 diffusion through microporous Teflon NH3, CO2和SO2通过微孔聚四氟乙烯扩散的在线分析
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H
Irina Tarische, Decebal Ciurchea, Patrizio Madau, Liliana Olenic
{"title":"On-line analysis of NH3, CO2, and SO2 diffusion through microporous Teflon","authors":"Irina Tarische,&nbsp;Decebal Ciurchea,&nbsp;Patrizio Madau,&nbsp;Liliana Olenic","doi":"10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","url":null,"abstract":"<p>Dynamic responses of self-made potentiometric NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> sensitive gas sensors are followed in the 10<sup>−5</sup>–5 × 10<sup>−3</sup>M concentration range. By least squares fitting of potential versus time curves, Dk product values at the diffusion of NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> through microporous Teflon are calculated. The obtained results are fairly reflected by the behavior of the sensor. Measurements of potential versus time in mixed solutions of CO<sub>2</sub> and SO<sub>2</sub> with the CO<sub>2</sub> sensitive sensor indicate the presence of the interferent. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 224–228, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"224-228"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88092011","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Study on the implementation of flow titrations in sequential injection analysis 流动滴定法在序贯注射分析中的应用研究
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<207::AID-LRA5>3.0.CO;2-G
J. M. Estela, F. Mas, A. Cladera, V. Cerdà
{"title":"Study on the implementation of flow titrations in sequential injection analysis","authors":"J. M. Estela,&nbsp;F. Mas,&nbsp;A. Cladera,&nbsp;V. Cerdà","doi":"10.1002/(SICI)1098-2728(1999)11:4<207::AID-LRA5>3.0.CO;2-G","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:4<207::AID-LRA5>3.0.CO;2-G","url":null,"abstract":"<p>Several variables that affect flow spectrophotometric titrations in sequential injection analysis (SIA) systems were studied by using titration of a strong acid with a strong base as a model; blue bromothymol was used as an indicator and distilled water was used as a carrier. Both possibilities of performing titrations on SIA systems according to the aspiration sequences (a) titrant B/sample/titrant A and (b) titrant/sample are considered. In case (a) the possibilities regarding the use of different volumes and/or different concentrations of titrant reagents were studied and are discussed. The established methodology allows hydrochloric acid determinations with 0.1 M sodium hydroxide within the range 32–1000 mM by means of logarithmic calibration curves. The analysis rate is of 5 min/sample. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 207–216, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"207-216"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<207::AID-LRA5>3.0.CO;2-G","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77288870","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Binding mode of Co(en) with calf thymus DNA Co(en)与小牛胸腺DNA的结合方式
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<193::AID-LRA3>3.0.CO;2-S
Jingwan Kang, Jing Chen, Zhihua Wang, Xiaoquan Lu, Yumin Song, Jinzhang Gao
{"title":"Binding mode of Co(en) with calf thymus DNA","authors":"Jingwan Kang,&nbsp;Jing Chen,&nbsp;Zhihua Wang,&nbsp;Xiaoquan Lu,&nbsp;Yumin Song,&nbsp;Jinzhang Gao","doi":"10.1002/(SICI)1098-2728(1999)11:4<193::AID-LRA3>3.0.CO;2-S","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:4<193::AID-LRA3>3.0.CO;2-S","url":null,"abstract":"<p>The binding mode of Co(en) (en = ethylenediamine) to calf thymus DNA is investigated using electrochemical and spectroscopic methods. Binding constant value (K = 1.284 × 10<sup>3</sup> L/mol) is found to be the same by the two methods. Both isomers show the same CV behavior associated with binding to B-form DNA. CD spectra results show no enantoselectivety for both isomers binding to DNA. All of this evidence suggests that the Co(en) complex binds to DNA by an electrostatic mode. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 193–196, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"193-196"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<193::AID-LRA3>3.0.CO;2-S","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79102142","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Flow injection potentiometric determination of saccharin in dietary products using a tubular ion-selective electrode 用管状离子选择电极流动注射电位法测定膳食产品中的糖精
Laboratory Robotics and Automation Pub Date : 1999-08-31 DOI: 10.1002/(SICI)1098-2728(1999)11:4<234::AID-LRA9>3.0.CO;2-A
Orlando Fatibello-Filho, Clezio Aniceto
{"title":"Flow injection potentiometric determination of saccharin in dietary products using a tubular ion-selective electrode","authors":"Orlando Fatibello-Filho,&nbsp;Clezio Aniceto","doi":"10.1002/(SICI)1098-2728(1999)11:4<234::AID-LRA9>3.0.CO;2-A","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:4<234::AID-LRA9>3.0.CO;2-A","url":null,"abstract":"<p>The construction and analytical evaluation of a tubular ion-selective electrode coated with an ion pair formed between saccharinate anion and toluidine blue O cation incorporated on a poly(vinylchloride) (PVC) matrix was constructed and adapted in a flow-injection (FI) system. The optimum experimental conditions found were an analytical path of 120 cm, an injection sample volume of 500 μL, a pH of 2.5, a flow rate of 2.3 mL min<sup>−1</sup>, and a tubular electrode length of 2.5 cm. The linear response to saccharin concentration ranged from 1.0 × 10<sup>−4</sup> to 2.0 × 10<sup>−2</sup> mol L<sup>−1</sup>, with a slope of −53.1 ± 0.4 mV/decade and a detection limit of 8.0 × 10<sup>−5</sup> mol L<sup>−1</sup>. The analytical frequency was 40 determinations h<sup>−1</sup>, and this system was used with success for saccharin determination in several dietary products. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 234–239, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"234-239"},"PeriodicalIF":0.0,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<234::AID-LRA9>3.0.CO;2-A","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80237111","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Report on the Ninth International Conference on Flow Injection Analysis (ICFIA 98) held jointly with the Japanese Association for Flow Injection Analysis (JAFIA), August 23–27, 1998, Seattle, Washington, USA 与日本流动注射分析协会(JAFIA)联合举办的第九届流动注射分析国际会议(ICFIA 98)报告,1998年8月23日至27日,美国华盛顿西雅图
Laboratory Robotics and Automation Pub Date : 1999-07-14 DOI: 10.1002/(SICI)1098-2728(1999)11:3<169::AID-LRA8>3.0.CO;2-1
Kate Grudpan, Gary D. Christian
{"title":"Report on the Ninth International Conference on Flow Injection Analysis (ICFIA 98) held jointly with the Japanese Association for Flow Injection Analysis (JAFIA), August 23–27, 1998, Seattle, Washington, USA","authors":"Kate Grudpan,&nbsp;Gary D. Christian","doi":"10.1002/(SICI)1098-2728(1999)11:3<169::AID-LRA8>3.0.CO;2-1","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:3<169::AID-LRA8>3.0.CO;2-1","url":null,"abstract":"","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 3","pages":"169-174"},"PeriodicalIF":0.0,"publicationDate":"1999-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:3<169::AID-LRA8>3.0.CO;2-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74503380","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design of a very versatile software program for automating analytical methods 设计一个非常通用的自动化分析方法的软件程序
Laboratory Robotics and Automation Pub Date : 1999-07-14 DOI: 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO;2-9
E. Becerra, A. Cladera, V. Cerdà
{"title":"Design of a very versatile software program for automating analytical methods","authors":"E. Becerra,&nbsp;A. Cladera,&nbsp;V. Cerdà","doi":"10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO;2-9","DOIUrl":"10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO;2-9","url":null,"abstract":"<p>The present article proposes the design of a hardware-independent system for automating various analytical methods. System design is based on the division of the software into four layers, defining a communications interface among them. The definition of these layers allows the isolation of the highest, corresponding to the analytical application, from the lowest, the hardware, composed of the various parts of the block diagram.</p><p>Although this system was initially designed for automating flow techniques (flow-injection analysis, FIA, and sequential-injection analysis, SIA), its conception allows the development of much more general applications, depending on the user's imagination.</p><p>The system is very open, in the sense that it is not necessary to adapt the program as system possibilities are expanded. Thus, if new instrumentation (modules in the block diagram) is incorporated, one need only develop independently a minimum of software to comply with the previously defined interface.</p><p>This system has been developed under the 32-bit Windows 95 environment, making the exchange of information with other applications very simple and allowing the various possibilities offered by the program to be executed simultaneously (for example, data acquisition and processing). © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 131–140, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 3","pages":"131-140"},"PeriodicalIF":0.0,"publicationDate":"1999-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO;2-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74545384","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 79
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书