On-line analysis of NH3, CO2, and SO2 diffusion through microporous Teflon

Irina Tarische, Decebal Ciurchea, Patrizio Madau, Liliana Olenic
{"title":"On-line analysis of NH3, CO2, and SO2 diffusion through microporous Teflon","authors":"Irina Tarische,&nbsp;Decebal Ciurchea,&nbsp;Patrizio Madau,&nbsp;Liliana Olenic","doi":"10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","DOIUrl":null,"url":null,"abstract":"<p>Dynamic responses of self-made potentiometric NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> sensitive gas sensors are followed in the 10<sup>−5</sup>–5 × 10<sup>−3</sup>M concentration range. By least squares fitting of potential versus time curves, Dk product values at the diffusion of NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> through microporous Teflon are calculated. The obtained results are fairly reflected by the behavior of the sensor. Measurements of potential versus time in mixed solutions of CO<sub>2</sub> and SO<sub>2</sub> with the CO<sub>2</sub> sensitive sensor indicate the presence of the interferent. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 224–228, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"224-228"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A4%3C224%3A%3AAID-LRA7%3E3.0.CO%3B2-H","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Dynamic responses of self-made potentiometric NH3, CO2, and SO2 sensitive gas sensors are followed in the 10−5–5 × 10−3M concentration range. By least squares fitting of potential versus time curves, Dk product values at the diffusion of NH3, CO2, and SO2 through microporous Teflon are calculated. The obtained results are fairly reflected by the behavior of the sensor. Measurements of potential versus time in mixed solutions of CO2 and SO2 with the CO2 sensitive sensor indicate the presence of the interferent. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 224–228, 1999

NH3, CO2和SO2通过微孔聚四氟乙烯扩散的在线分析
在10−5 ~ 5 × 10−3M浓度范围内,对自制的电位式NH3、CO2和SO2敏感气体传感器进行了动态响应。通过电位-时间曲线的最小二乘拟合,计算了NH3、CO2和SO2在微孔聚四氟乙烯中扩散时的Dk积值。得到的结果很好地反映了传感器的性能。用CO2敏感传感器测量CO2和SO2混合溶液中电位随时间的变化表明存在干扰。©1999 John Wiley &儿子,Inc。实验室机器人与自动化11:224-228,1999
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信