Bioimaging最新文献

筛选
英文 中文
Multiphoton excitation of the DNA stains DAPI and Hoechst DAPI和Hoechst DNA染色的多光子激发
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<138::AID-BIO4>3.3.CO;2-B
I. Gryczynski, H. Malak, J. Lakowicz
{"title":"Multiphoton excitation of the DNA stains DAPI and Hoechst","authors":"I. Gryczynski, H. Malak, J. Lakowicz","doi":"10.1002/1361-6374(199609)4:3<138::AID-BIO4>3.3.CO;2-B","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<138::AID-BIO4>3.3.CO;2-B","url":null,"abstract":",6-diamidino-2-phenylindole hydrochloride (DAPI) andHoechst 33342 were found to display two- or three-photon excitation from 810 to 910nm. We examined the effect of excitation wavelength on the mode of excitation forDAPI and Hoechst 33342 in the solvent isobutanol and when bound to double helicalDNA. For DAPI and Hoechst 33342 in isobutanol the mode of excitation changed fromtwo- to three-photon excitation over this wavelength range, with apparent transitionwavelengths of 855 and 880 nm, respectively. However, when bound to DNA, thetransition wavelength from two- to three-photon excitation increased for both probes.In the case of DAPI–DNA, the apparent transition wavelength increased to 868 nm,and three-photon excitation occurred above 900 nm. For Hoechst 33342–DNA themode of excitation was a mixture of two- and three-photon excitation to the longestexcitation wavelength of 910 nm, and we were unable to observe pure three-photonexcitation for Hoechst 33342–DNA. In the transition region the anisotropy of DAPIwas dependent on laser power, illustrating that the mode of excitation and transitionwavelengths will depend on the precise experimental conditions. Higher spatialresolution was observed for three-photon excitation of DAPI than for two-photonexcitation of Hoechst 33342. These results suggest that these probes can be used foreither two- or three-photon imaging of DNA or chromosomes.Keywords: fluorescence, spectroscopy, imaging, time-resolved fluorescence,two-photon excitation, three-photon excitation, DAPI, Hoechst 33342, two-photonmicroscopy","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"107 1","pages":"138-148"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89690119","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 38
Gigantic optical non-linearities from nanoparticle-enhanced molecular probes with potential for selectively imaging the structure and physiology of nanometric regions in cellular systems 纳米颗粒增强分子探针的巨大光学非线性,具有选择性成像细胞系统中纳米区域结构和生理学的潜力
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G
Gadi Peleg, Aaron Lewis, Oleg Bouevitch, Leslie Loew, Dorit Parnas, Michal Linial
{"title":"Gigantic optical non-linearities from nanoparticle-enhanced molecular probes with potential for selectively imaging the structure and physiology of nanometric regions in cellular systems","authors":"Gadi Peleg,&nbsp;Aaron Lewis,&nbsp;Oleg Bouevitch,&nbsp;Leslie Loew,&nbsp;Dorit Parnas,&nbsp;Michal Linial","doi":"10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G","url":null,"abstract":"<p>The requirement to functionally probe biological structures, with ever increasing selectivity and three-dimensional resolution is a frontier area in microscopy. Non-linear optics has a unique potential in this regard with numerous studies focused on the potential of three-dimensional imaging with super-resolution. In this paper we demonstrate that non-linear optical phenomena, such as second harmonic (SH) generation, which is very sensitive to the membrane potential, can be locally enhanced by complexing or approaching a SH generating molecular probe to a nanoantenna of a silver or gold nanoparticle. This gives complexes with gigantic optical non-linearities. These contrast enhancing non-linear optical complexes have the potential to be directed selectively to specific nanometric regions in cells in order to report on alterations on the structure and the function in such regions while overcoming the inherent inefficiency of non-linear optical interactions.</p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"4 3","pages":"215-224"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72352706","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 26
Avalanche photodiode detection with object scanning and image restoration provides 2–4 fold resolution increase in two-photon fluorescence microscopy 雪崩光电二极管检测与物体扫描和图像恢复在双光子荧光显微镜中提供2-4倍的分辨率提高
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<187::AID-BIO9>3.0.CO;2-3
Hiroshi Kano, Hans T M van der Voort, Martin Schrader, Geert M P van Kempen, Stefan W Hell
{"title":"Avalanche photodiode detection with object scanning and image restoration provides 2–4 fold resolution increase in two-photon fluorescence microscopy","authors":"Hiroshi Kano,&nbsp;Hans T M van der Voort,&nbsp;Martin Schrader,&nbsp;Geert M P van Kempen,&nbsp;Stefan W Hell","doi":"10.1002/1361-6374(199609)4:3<187::AID-BIO9>3.0.CO;2-3","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<187::AID-BIO9>3.0.CO;2-3","url":null,"abstract":"<p>High-quantum-efficiency photodetection, millisecond pixel dwell time stage scanning and image restoration by maximum-likelihood estimation are synergetically combined and shown to improve the resolution of two-photon excitation microscopy 2–4 fold in all directions. Measurements of the two-photon excitation point-spread function (PSF) of a 1.4 aperture oil immersion lens are carried out by imaging fluorescence beads with a diameter of one seventh of the excitation wavelength (830 nm) and subsequent deconvolution with the bead object function. The proposed method of resolution increase is applied to beads as well as to rhodamine labelled actin fibres in mouse fibroblast cells. As the resolution improvement is not based on the non-linear effect of two-photon excitation, the results imply a comparable resolution increase in single-photon excitation confocal microscopy. In the fibroblasts, we established a three-fold improvement in axial resolution, namely from 840 nm before, to 280 nm after restoration (full-width at half-maximum). Actin fibres with axial distances of 850 nm, otherwise difficult to discern, are fully separated. In the lateral direction, images of fluorescence beads of about 110 nm diameter are restored to the real dimensions of the beads with an accuracy of better than one pixel (41 nm).</p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"4 3","pages":"187-197"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199609)4:3<187::AID-BIO9>3.0.CO;2-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72324659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 35
Three‐photon excitation fluorescence imaging of biological specimens using an all‐solid‐state laser 用全固态激光器对生物标本进行三光子激发荧光成像
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.3.CO;2-A
D. Wokosin, V. Centonze, S. Crittenden, J. White
{"title":"Three‐photon excitation fluorescence imaging of biological specimens using an all‐solid‐state laser","authors":"D. Wokosin, V. Centonze, S. Crittenden, J. White","doi":"10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.3.CO;2-A","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.3.CO;2-A","url":null,"abstract":"We demonstrate that three-photon excitation images of both fixed and living biological specimens can be readily obtained using an all-solid-state Nd:YLF laser excitation source. Optically sectioned images of fixed Caenorhabditis elegans embryos stained with DAPI and embryos triple-labeled with DAPI, fluorescein and Texas Red are presented. Time series images of a living LLC-PK cell stained with Hoechst 33342 during the progression from metaphase to telophase are also presented. The mode of excitation was inferred from the power-law of anthracene and Hoechst 33342 fluorescence versus incident laser power and an axial resolution comparison of anthracene fluorescence with two-photon excited Calcium Crimson fluorescence. Multiphoton excitation imaging is an attractive method for optically sectioning live specimens because of the lower levels of phototoxicity produced compared to other optical sectioning techniques. The combination of two- and three-photon excitation extends the capabilities of a multiple- photon imaging system since a single wavelength can provide localized excitation of a wide variety of fluorophores whose collective emission spectra can span the entire visible spectrum.","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"5 1","pages":"208-214"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77078514","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 80
Gigantic optical non‐linearities from nanoparticle‐enhanced molecular probes with potential for selectively imaging the structure and physiology of nanometric regions in cellular systems 纳米粒子增强分子探针的巨大光学非线性,具有选择性成像细胞系统中纳米区域结构和生理的潜力
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G
G. Peleg, A. Lewis, O. Bouevitch, L. Loew, D. Parnas, M. Linial
{"title":"Gigantic optical non‐linearities from nanoparticle‐enhanced molecular probes with potential for selectively imaging the structure and physiology of nanometric regions in cellular systems","authors":"G. Peleg, A. Lewis, O. Bouevitch, L. Loew, D. Parnas, M. Linial","doi":"10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<215::AID-BIO12>3.0.CO;2-G","url":null,"abstract":"The requirement to functionally probe biological structures, with ever increasing selectivity and three-dimensional resolution is a frontier area in microscopy. Non-linear optics has a unique potential in this regard with numerous studies focused on the potential of three-dimensional imaging with super-resolution. In this paper we demonstrate that non-linear optical phenomena, such as second harmonic (SH) generation, which is very sensitive to the membrane potential, can be locally enhanced by complexing or approaching a SH generating molecular probe to a nanoantenna of a silver or gold nanoparticle. This gives complexes with gigantic optical non-linearities. These contrast enhancing non-linear optical complexes have the potential to be directed selectively to specific nanometric regions in cells in order to report on alterations on the structure and the function in such regions while overcoming the inherent inefficiency of non-linear optical interactions.","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"14 1","pages":"215-224"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82674017","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 26
Using offset interfering beams for improved resolution in confocal imaging: The potential of the PSAF-technique 在共焦成像中使用偏移干涉光束提高分辨率:PSAF技术的潜力
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<179::AID-BIO8>3.0.CO;2-1
M Müller, G J Brakenhoff
{"title":"Using offset interfering beams for improved resolution in confocal imaging: The potential of the PSAF-technique","authors":"M Müller,&nbsp;G J Brakenhoff","doi":"10.1002/1361-6374(199609)4:3<179::AID-BIO8>3.0.CO;2-1","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<179::AID-BIO8>3.0.CO;2-1","url":null,"abstract":"<p>The interferometric spatial overlap of two laterally offset focal field distributions of a high numerical aperture lens in combination with confocal detection lead to improved resolution in confocal imaging. Experimental data of the achieved signal, the point spread autocorrelation function (PSAF), are presented for both the lateral and axial directions. Numerical simulations of lateral PSAF imaging of selected fluorescent objects show an increased resolution of up to 30% with moderate ringing, obtainable also in the presence of moderate spherical aberrations.</p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"4 3","pages":"179-186"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199609)4:3<179::AID-BIO8>3.0.CO;2-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72324631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Three-photon excitation fluorescence imaging of biological specimens using an all-solid-state laser 全固态激光对生物样品的三光子激发荧光成像
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.0.CO;2-J
David L Wokosin, Victoria E Centonze, Sarah Crittenden, John White
{"title":"Three-photon excitation fluorescence imaging of biological specimens using an all-solid-state laser","authors":"David L Wokosin,&nbsp;Victoria E Centonze,&nbsp;Sarah Crittenden,&nbsp;John White","doi":"10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.0.CO;2-J","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.0.CO;2-J","url":null,"abstract":"<p>We demonstrate that three-photon excitation images of both fixed and living biological specimens can be readily obtained using an all-solid-state Nd:YLF laser excitation source. Optically sectioned images of fixed <i>Caenorhabditis elegans</i> embryos stained with DAPI and embryos triple-labeled with DAPI, fluorescein and Texas Red are presented. Time series images of a living LLC-PK cell stained with Hoechst 33342 during the progression from metaphase to telophase are also presented. The mode of excitation was inferred from the power-law of anthracene and Hoechst 33342 fluorescence versus incident laser power and an axial resolution comparison of anthracene fluorescence with two-photon excited Calcium Crimson fluorescence. Multiphoton excitation imaging is an attractive method for optically sectioning live specimens because of the lower levels of phototoxicity produced compared to other optical sectioning techniques. The combination of two- and three-photon excitation extends the capabilities of a multiple- photon imaging system since a single wavelength can provide localized excitation of a wide variety of fluorophores whose collective emission spectra can span the entire visible spectrum.</p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"4 3","pages":"208-214"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.0.CO;2-J","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72324655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Image formation in three‐photon fluorescence microscopy 三光子荧光显微镜中的图像形成
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<124::AID-BIO2>3.0.CO;2-2
C. Sheppard
{"title":"Image formation in three‐photon fluorescence microscopy","authors":"C. Sheppard","doi":"10.1002/1361-6374(199609)4:3<124::AID-BIO2>3.0.CO;2-2","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<124::AID-BIO2>3.0.CO;2-2","url":null,"abstract":"Image formation in three-photon fluorescence microscopy is analysed. The point spread function, three-dimensional optical transfer function and axial resolution are considered. The results are generalized to multiphoton fluorescence. Three-photon fluorescence is particularly amenable to resolution improvement by use of pupil filters.","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"102 3 Suppl 1","pages":"124-128"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77275998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Continuous scanning micro-photolysis: A simple laser scanning microscopic method for lateral transport measurements employing single- or two-photon excitation 连续扫描微光解:一种利用单光子或双光子激发进行横向输运测量的简单激光扫描显微方法
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.0.CO;2-C
Ignacy Gryczynski, Ulrich Kubitscheck, Oliver Heinrich, Reiner Peters
{"title":"Continuous scanning micro-photolysis: A simple laser scanning microscopic method for lateral transport measurements employing single- or two-photon excitation","authors":"Ignacy Gryczynski,&nbsp;Ulrich Kubitscheck,&nbsp;Oliver Heinrich,&nbsp;Reiner Peters","doi":"10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.0.CO;2-C","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.0.CO;2-C","url":null,"abstract":"<p>A comparatively simple laser scanning microscopic method for the determination of lateral diffusion coefficients at high temporal and spatial resolution is described. Combining two previously developed methods, continuous fluorescence microphotolysis and scanning microphotolysis, the new method is referred to as continuous scanning microphotolysis (continuous SCAMP). The principle of the method is simply to operate a commercial laser scanning microscope in the line scanning mode while monitoring the fluorescence emitted from the continuously scanned line as an <i>x–t</i> ‘image’. Fluorescence excitation can be effected by either single- or two-photon absorption. In the former case a standard, low power ion laser is sufficient while for two-photon excitation a femtosecond-pulsed titan sapphire laser can be employed. In both cases the laser beam power is adjusted such that a substantial but not excessive degree of photobleaching is induced. <i>x–t</i> images are evaluated so as to determine the dependence of the scanned line intensities on the scanning time. The fluorescence decay curves obtained in this manner are evaluated in terms of diffusion coefficients and photobleaching rate constants by numerical simulation of appropriate diffusion-reaction systems. The validity of the experimental and theoretical procedures was tested by measurements on a simple well-defined model system. The results suggested that the continuous SCAMP, when using single-photon excitation, is a particularly simple and sensitive method for determining lateral diffusion in two-dimensional systems such as cell membranes. Employing two-photon excitation, on the other hand, provides the continuous SCAMP with the capability for studying three-dimensional diffusion within cells, cell organelles and similar systems by still comparatively simple means. Keywords: confocal microscopy, continuous fluorescence microphotolysis, fluorescence photobleaching, lateral diffusion, two-photon excitation </p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"4 3","pages":"158-167"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.0.CO;2-C","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72324661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Continuous scanning micro‐photolysis: A simple laser scanning microscopic method for lateral transport measurements employing single‐ or two‐photon excitation 连续扫描微光解:一种简单的激光扫描显微方法,利用单光子或双光子激发进行横向传输测量
Bioimaging Pub Date : 1996-09-01 DOI: 10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.3.CO;2-3
I. Gryczynski, U. Kubitscheck, O. Heinrich, R. Peters
{"title":"Continuous scanning micro‐photolysis: A simple laser scanning microscopic method for lateral transport measurements employing single‐ or two‐photon excitation","authors":"I. Gryczynski, U. Kubitscheck, O. Heinrich, R. Peters","doi":"10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.3.CO;2-3","DOIUrl":"https://doi.org/10.1002/1361-6374(199609)4:3<158::AID-BIO6>3.3.CO;2-3","url":null,"abstract":"","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"125 1","pages":"158-167"},"PeriodicalIF":0.0,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72563314","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信