{"title":"Front & Back Matter","authors":"","doi":"10.1159/000505038","DOIUrl":"https://doi.org/10.1159/000505038","url":null,"abstract":"","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76860731","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Wolter, K. Gordon, Jennifer L. Campos, Luis D. Vilchez Madrigal, D. Pothier, Cían O. Hughes, B. Papsin, S. Cushing
{"title":"BalanCI: Head-Referenced Cochlear Implant Stimulation Improves Balance in Children with Bilateral Cochleovestibular Loss","authors":"N. Wolter, K. Gordon, Jennifer L. Campos, Luis D. Vilchez Madrigal, D. Pothier, Cían O. Hughes, B. Papsin, S. Cushing","doi":"10.1159/000503135","DOIUrl":"https://doi.org/10.1159/000503135","url":null,"abstract":"Introduction: To determine the impact of a head-referenced cochlear implant (CI) stimulation system, BalanCI, on balance and postural control in children with bilateral cochleovestibular loss (BCVL) who use bilateral CI. Methods: Prospective, blinded case-control study. Balance and postural control testing occurred in two settings: (1) quiet clinical setting and (2) immersive realistic virtual environment (Challenging Environment Assessment Laboratory [CEAL], Toronto Rehabilitation Institute). Postural control was assessed in 16 and balance in 10 children with BCVL who use bilateral CI, along with 10 typically developing children. Children with neuromotor, cognitive, or visual deficits that would prevent them from performing the tests were excluded. Children wore the BalanCI, which is a head-mounted device that couples with their CIs through the audio port and provides head-referenced spatial information delivered via the intracochlear electrode array. Postural control was measured by center of pressure (COP) and time to fall using the WiiTM (Nintendo, WA, USA) Balance Board for feet and the BalanCI for head, during the administration of the Modified Clinical Test of Sensory Interaction in Balance (CTSIB-M). The COP of the head and feet were assessed for change by deviation, measured as root mean square around the COP (COP-RMS), rate of deviation (COP-RMS/duration), and rate of path length change from center (COP-velocity). Balance was assessed by the Bruininks-Oseretsky Test of Motor Proficiency 2, balance subtest (BOT-2), specifically, BOT-2 score as well as time to fall/fault. Results: In the virtual environment, children demonstrated more stable balance when using BalanCI as measured by an improvement in BOT-2 scores. In a quiet clinical setting, the use of BalanCI led to improved postural control as demonstrated by significant reductions in COP-RMS and COP-velocity. With the use of BalanCI, the number of falls/faults was significantly reduced and time to fall increased. Conclusions: BalanCI is a simple and effective means of improving postural control and balance in children with BCVL who use bilateral CI. BalanCI could potentially improve the safety of these children, reduce the effort they expend maintaining balance and allow them to take part in more complex balance tasks where sensory information may be limited and/or noisy.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"32 1","pages":"60 - 71"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77336535","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Cochlear Dead Regions in Sporadic Unilateral Vestibular Schwannomas Using the Threshold-Equalizing Noise Test","authors":"Hayoung Byun, Yang-Sun Cho, S. Hong, I. Moon","doi":"10.1159/000503164","DOIUrl":"https://doi.org/10.1159/000503164","url":null,"abstract":"Background: Vestibular schwannoma (VS) is a benign intracranial neoplasm originating in the Schwann cells of the vestibular nerve. Despite its origin, the most common symptom is sensorineural hearing loss which is presented in more than 90% of patients. The underlying pathophysiology of this hearing loss has not been fully understood. Objective: To assess the in vivo function of cochlear inner hair cells and spiral ganglion neurons in VS, cochlear dead regions (DRs) were evaluated via the threshold-equalizing noise (TEN) test in untreated VS patients. Method: Untreated patients diagnosed with sporadic unilateral VS and normal contralesional hearing were enrolled from July 2011 to June 2016. Audiometric evaluation including TEN tests were performed. Based on the magnetic resonance findings, characteristics of individual tumors were assessed. Results: The average pure-tone threshold (word recognition score [WRS]) of 23 enrolled patients was 42.7 dB (76.1%). Nineteen DRs (11.8% of 161 tested frequencies) were found in 8 patients (34.8% of enrolled cases). Among the intracanalicular (IAC) tumors, 6 out of 10 ears (60%) carried DRs, while 2 of 13 (15.4%) showed DRs among the cerebellopontine angle (CPA) lesions (p = 0.039). Pure-tone thresholds and WRS were not different between the two groups. Logistic regression analysis showed that the tumor location, IAC versus CPA, was significantly associated with DRs (p = 0.041, Nagelkerke R2 = 0.471), whereas age, sex, tumor size, distance from the tumor to the cochlea, T2-weighted hypointensity on the MRI and pure-tone thresholds showed no significance. Conclusions: Cochlear DRs are detected in hearing losses associated with unilateral sporadic VS using the TEN test. Individual DRs were detected variously in high, mid, or low frequencies. In our preliminary data, IAC tumors showed a higher number of DRs than CPA tumors despite similar average hearing thresholds. Further studies including longitudinal follow-up of hearing as well as change in DRs may provide useful information about VS patients.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"5 1","pages":"271 - 278"},"PeriodicalIF":0.0,"publicationDate":"2019-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81296387","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Merve Ozbal Batuk, M. Yaralı, B. Cinar, Aysun Parlak Kocabay, M. Bajin, G. Sennaroğlu, L. Sennaroğlu
{"title":"Is Early Cochlear Implant Device Activation Safe for All on-the-Ear and off-the-Ear Sound Processors?","authors":"Merve Ozbal Batuk, M. Yaralı, B. Cinar, Aysun Parlak Kocabay, M. Bajin, G. Sennaroğlu, L. Sennaroğlu","doi":"10.1159/000503378","DOIUrl":"https://doi.org/10.1159/000503378","url":null,"abstract":"Background: Cochlear implantation (CI) is an effective treatment option for patients with severe-to-profound hearing loss. When CI first started, it was recommended to wait until at least 4 weeks after the CI surgery for the initial activation because of possible complications. Advances in the surgical techniques and experiences in fitting have made initial activation possible within 24 h. Objectives: To compare the complaints and complications after early activation between behind-the-ear (BTE) and off-the-ear (OTE) sound processors and to show the impact of early activation on the electrode impedance values. Method: CI surgeries performed between March 2013 and July 2018 were retrospectively analyzed from the database. In total, 294 CI users were included in the present study. The impedance measurements were analyzed postoperatively at the initial activation prior to the stimulation, and 4 weeks after the initial activation in the first-month follow-up visit. A customized questionnaire was administered in the first-month follow-up fitting session to caregivers and/or patients who were using CI at least for 6 months. Medical records were also reviewed to identify any postoperative complications. Results: In the early activation group, impedance values were significantly lower than in the control group (p < 0.05) at first fitting. At the first-month follow-up, no significant difference was found between the groups (p > 0.05). The most common side effects were reported to be edema (6.1%) and pain (5.7%) in the early activation group. In patients with OTE sound processors, the rate of side effects such as skin infection, wound swelling, skin hyperemia, and pain was higher than in patients with BTE sound processors; however, a statistical significance was only observed in wound swelling (p = 0.005). Selecting the appropriate magnet was defined as a problem for the OTE sound processors during the initial activation. Conclusion: This study revealed that early activation of CI was clinically safe and feasible in patients with BTE sound processors. When using OTE sound processors, the audiologists should be careful during the activation period and inform patients of possible side effects. The first fitting should be delayed for 4 weeks after CI for OTE sound processors. This current study is the first to report this finding with 5 years of experience in a large cohort.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"39 1","pages":"279 - 284"},"PeriodicalIF":0.0,"publicationDate":"2019-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73966776","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Schultz, Patrícia Helena Pecora Liberman, Maria Valéria Schmidt Goffi-Gomez
{"title":"Are There Cochlear Dead Regions Involved in Hearing Loss after Cisplatin Ototoxicity?","authors":"C. Schultz, Patrícia Helena Pecora Liberman, Maria Valéria Schmidt Goffi-Gomez","doi":"10.1159/000502250","DOIUrl":"https://doi.org/10.1159/000502250","url":null,"abstract":"Background: The most common complaint of patients affected by chemotherapy-induced hearing loss is difficulty understanding speech in noisy environments despite the use of hearing aids. Cochlear dead regions, those areas with damaged or absent inner hair cells and dendrites, may account for this type of hearing loss. However, it is unknown whether this condition is associated with cisplatin agents. Objective: The aim of this study was to determine whether cisplatin is associated with hearing loss and cochlear dead regions. Methods: This prospective cross-sectional study was conducted in patients participating in routine audiological monitoring during and after chemotherapy treatment. Adults undergoing audiological evaluation who had completed chemotherapy treatment were invited to participate. Patients were divided into 3 groups according to pure tone thresholds. Group 1 patients had thresholds over 70 dB (HL) at 2,000 Hz and higher frequencies. Group 2 patients had thresholds below 70 dB (HL) up to 2,000 Hz. Patients in the control group had normal thresholds at all frequencies. The threshold equalizing noise test (TEN[HL]) was used to identify cochlear dead regions by repeating thresholds in the presence of TEN noise played from a compact disc. The presence of cochlear dead regions was established when the masked threshold was 10 dB or greater above the TEN level and 10 dB or greater above the absolute threshold at any frequency. Results: Twelve patients were included in study group 1, 10 patients in study group 2, and 7 patients in the control group. Cochlear dead regions were present in all patients with hearing loss and in none of the control group. For groups 1 and 2, mean differences between absolute and masked thresholds were 21 and 16 dB at 500 Hz; 22 and 15 dB at 1,000 Hz; 31 and 17 dB at 2,000 Hz; 32 and 20 dB at 3,000 Hz; and 31 and 21 dB at 4,000 Hz, respectively. Nevertheless, analysis of variance testing with Bonferroni analysis showed a difference between groups 1 and 2 only at 2,000, 3,000, and 4,000 Hz. Conclusion: We found unresponsive or dead cochlear regions in patients who had undergone cisplatin chemotherapy even among patients with mild to moderate hearing loss.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"64 1","pages":"253 - 257"},"PeriodicalIF":0.0,"publicationDate":"2019-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73143350","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Starkov, N. Guinand, F. Lucieer, Maurizio Ranieri, Samuel Cavuscens, M. Pleshkov, J. Guyot, H. Kingma, S. Ramat, A. Pérez-Fornos, R. van de Berg
{"title":"Restoring the High-Frequency Dynamic Visual Acuity with a Vestibular Implant Prototype in Humans","authors":"D. Starkov, N. Guinand, F. Lucieer, Maurizio Ranieri, Samuel Cavuscens, M. Pleshkov, J. Guyot, H. Kingma, S. Ramat, A. Pérez-Fornos, R. van de Berg","doi":"10.1159/000503677","DOIUrl":"https://doi.org/10.1159/000503677","url":null,"abstract":"Introduction: The vestibular implant could become a clinically useful device in the near future. This study investigated the feasibility of restoring the high-frequency dynamic visual acuity (DVA) with a vestibular implant, using the functional Head Impulse Test (fHIT). Methods: A 72-year-old female, with bilateral vestibulopathy and fitted with a modified cochlear implant incorporating three vestibular electrodes (MED-EL, Innsbruck, Austria), was available for this study. Electrical stimulation was delivered with the electrode close to the lateral ampullary nerve in the left ear. The high-frequency DVA in the horizontal plane was tested with the fHIT. After training, the patient underwent six trials of fHIT, each with a different setting of the vestibular implant: (1) System OFF before stimulation; (2) System ON, baseline stimulation; (3) System ON, reversed stimulation; (4) System ON, positive stimulation; (5) System OFF, without delay after stimulation offset; and (6) System OFF, 25 min delay after stimulation offset. The percentage of correct fHIT scores for right and left head impulses were compared between trials. Results: Vestibular implant stimulation improved the high-frequency DVA compared to no stimulation. This improvement was significant for “System ON, baseline stimulation” (p = 0.02) and “System ON, positive stimulation” (p < 0.001). fHIT scores changed from 19 to 44% (no stimulation) to maximum 75–94% (System ON, positive stimulation). Conclusion: The vestibular implant seems capable of improving the high-frequency DVA. This functional benefit of the vestibular implant illustrates again the feasibility of this device for clinical use in the near future.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"63 1","pages":"91 - 95"},"PeriodicalIF":0.0,"publicationDate":"2019-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83354816","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Honeder, Chengjing Zhu, J. Gausterer, H. Schöpper, N. Ahmadi, Nodir Saidov, Michael Nieratschker, F. Gabor, C. Arnoldner
{"title":"Sustained-Release Triamcinolone Acetonide Hydrogels Reduce Hearing Threshold Shifts in a Model for Cochlear Implantation with Hearing Preservation","authors":"C. Honeder, Chengjing Zhu, J. Gausterer, H. Schöpper, N. Ahmadi, Nodir Saidov, Michael Nieratschker, F. Gabor, C. Arnoldner","doi":"10.1159/000501331","DOIUrl":"https://doi.org/10.1159/000501331","url":null,"abstract":"Introduction: In recent years, the preservation of residual hearing has become a major factor in patients undergoing cochlear implantation (CI). In studies attempting to pharmaceutically improve hearing preservation rates, glucocorticoids (GCs) applied perioperatively in many institutions have emerged as a promising treatment regimen. Although dexamethasone is most commonly used and has been applied successfully by various research groups, recently pharmacological properties have been reported to be relatively unsuitable for topical delivery to the inner ear. Consequently other glucocorticoids merit further evaluation. The aim of this study was therefore to evaluate the otoprotective effects of the topical application of a sustained-release triamcinolone acetonide (TAAC) hydrogel in CI with hearing preservation. Methods: Normal-hearing pigmented guinea pigs were randomized into a group receiving a single dose of a 6% TAAC poloxamer 407 hydrogel, a group receiving a 30% TAAC hydrogel and a control group. All hydrogel applications were performed 1 day prior to CI. After a cochleostomy was drilled, a specifically designed silicone electrode was inserted into the scala tympani for 5 mm. Frequency-specific compound action potentials of the auditory nerve (0.5–32 kHz) were measured pre- and directly postoperatively as well as on days 3, 7, 14, 21, and 28. Finally, temporal bones were harvested for histological evaluation. Results: Application of the TAAC hydrogels resulted in significantly reduced hearing threshold shifts in low, middle and high frequencies and improved spiral ganglion cell survival in the second turn of the cochlea. Outer hair cell numbers in the basal and second turn of the cochlea were slightly reduced after TAAC application. Conclusion: In summary, we were able to demonstrate functional benefits of a single preoperative application of a TAAC hydrogel in a guinea pig model for CI, which persisted until the end of the observational period, that is, 28 days after surgery.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"41 1","pages":"237 - 244"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84283470","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Front & Back Matter","authors":"","doi":"10.1159/000503980","DOIUrl":"https://doi.org/10.1159/000503980","url":null,"abstract":"","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"19 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82699938","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Concepts and Physiological Aspects of the Otolith Organ in Relation to Electrical Stimulation","authors":"I. Curthoys","doi":"10.1159/000502712","DOIUrl":"https://doi.org/10.1159/000502712","url":null,"abstract":"Background: This paper discusses some of the concepts and major physiological issues in developing a means of electrically stimulating the otolithic system, with the final goal being the electrical stimulation of the otoliths in human patients. It contrasts the challenges of electrical stimulation of the otolith organs as compared to stimulation of the semicircular canals. Electrical stimulation may consist of trains of short-duration pulses (e.g., 0.1 ms duration at 400 Hz) by selective electrodes on otolith maculae or otolithic afferents, or unselective maintained DC stimulation by large surface electrodes on the mastoids – surface galvanic stimulation. Summary: Recent anatomical and physiological results are summarized in order to introduce some of the unique issues in electrical stimulation of the otoliths. The first challenge is that each otolithic macula contains receptors with opposite polarization (opposing preferred directions of stimulation), unlike the uniform polarization of receptors in each semicircular canal crista. The puzzle is that in response to the one linear acceleration in the one macula, some otolithic afferents have an increased activation whereas others have decreased activation. Key Messages: At the vestibular nucleus this opposite receptor hair cell polarization and consequent opposite afferent input allow enhanced response to the one linear acceleration, via a “push-pull” neural mechanism in a manner analogous to the enhancement of semicircular canal responses to angular acceleration. Within each otolithic macula there is not just one uniform otolithic neural input to the brain – there are very distinctly different channels of otolithic neural inputs transferring the neural data to the brainstem. As a simplification these channels are characterized as the sustained and transient systems. Afferents in each system have different responses to stimulus onset and maintained stimulation and likely different projections, and most importantly different thresholds for activation by electrical stimulation and different adaptation rates to maintained stimulation. The implications of these differences are considered.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"5 1","pages":"25 - 34"},"PeriodicalIF":0.0,"publicationDate":"2019-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91370786","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Çakır Çetin, Selhan Gurkan, G. Kırkım, E. A. Guneri
{"title":"Wide-Band Tympanometry Results during an Acute Episode of Ménière’s Disease","authors":"A. Çakır Çetin, Selhan Gurkan, G. Kırkım, E. A. Guneri","doi":"10.1159/000502768","DOIUrl":"https://doi.org/10.1159/000502768","url":null,"abstract":"Background: Wide-band tympanometry (WBT) was introduced as a beneficial diagnostic test for Ménière’s disease (MD) almost 15 years ago. However, an acute episode of MD has not been evaluated by using WBT yet. Objective: To investigate WBT findings in patients with MD during acute attacks. Method: Thirty definite MD patients with unilateral acute low-tone sensorineural hearing loss and aural fullness, and thirty age- and sex-matched control subjects were enrolled prospectively in a tertiary referral center. Ears were divided into three groups as follows: (1) affected ears of MD patients, (2) contralateral ears of MD patients, (3) control ears. Individuals underwent WBT. The resonance frequency (RF), mean absorbance value, mean low- and high-frequency absorbance values (LF-A and HF-A), and double peak width at 2 kHz of conductance tympanometry (2-kHz PW) were assessed. Results: Seventy percent in group 1, 66.7% in group 2, and 78.3% in group 3 demonstrated double peaks at 2 kHz. The mean 2-kHz PW values were 157.52 ± 79.19, 177.40 ± 79.14, and 139.64 ± 87.501 daPa for groups 1, 2, and 3, respectively. There were no significant differences between groups with respect to 2-kHz PW, RF, absorbance, LF-A, and HF-A. Conclusion: This was the first study that evaluated the effects of acute Ménière attacks on WBT findings. An acute Ménière attack was found to have no significant effect on the 2-kHz PW and other variables measured using WBT.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"24 1","pages":"231 - 236"},"PeriodicalIF":0.0,"publicationDate":"2019-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88576687","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}