A. Çakır Çetin, Selhan Gurkan, G. Kırkım, E. A. Guneri
{"title":"Wide-Band Tympanometry Results during an Acute Episode of Ménière’s Disease","authors":"A. Çakır Çetin, Selhan Gurkan, G. Kırkım, E. A. Guneri","doi":"10.1159/000502768","DOIUrl":null,"url":null,"abstract":"Background: Wide-band tympanometry (WBT) was introduced as a beneficial diagnostic test for Ménière’s disease (MD) almost 15 years ago. However, an acute episode of MD has not been evaluated by using WBT yet. Objective: To investigate WBT findings in patients with MD during acute attacks. Method: Thirty definite MD patients with unilateral acute low-tone sensorineural hearing loss and aural fullness, and thirty age- and sex-matched control subjects were enrolled prospectively in a tertiary referral center. Ears were divided into three groups as follows: (1) affected ears of MD patients, (2) contralateral ears of MD patients, (3) control ears. Individuals underwent WBT. The resonance frequency (RF), mean absorbance value, mean low- and high-frequency absorbance values (LF-A and HF-A), and double peak width at 2 kHz of conductance tympanometry (2-kHz PW) were assessed. Results: Seventy percent in group 1, 66.7% in group 2, and 78.3% in group 3 demonstrated double peaks at 2 kHz. The mean 2-kHz PW values were 157.52 ± 79.19, 177.40 ± 79.14, and 139.64 ± 87.501 daPa for groups 1, 2, and 3, respectively. There were no significant differences between groups with respect to 2-kHz PW, RF, absorbance, LF-A, and HF-A. Conclusion: This was the first study that evaluated the effects of acute Ménière attacks on WBT findings. An acute Ménière attack was found to have no significant effect on the 2-kHz PW and other variables measured using WBT.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":"24 1","pages":"231 - 236"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology and Neurotology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000502768","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
Background: Wide-band tympanometry (WBT) was introduced as a beneficial diagnostic test for Ménière’s disease (MD) almost 15 years ago. However, an acute episode of MD has not been evaluated by using WBT yet. Objective: To investigate WBT findings in patients with MD during acute attacks. Method: Thirty definite MD patients with unilateral acute low-tone sensorineural hearing loss and aural fullness, and thirty age- and sex-matched control subjects were enrolled prospectively in a tertiary referral center. Ears were divided into three groups as follows: (1) affected ears of MD patients, (2) contralateral ears of MD patients, (3) control ears. Individuals underwent WBT. The resonance frequency (RF), mean absorbance value, mean low- and high-frequency absorbance values (LF-A and HF-A), and double peak width at 2 kHz of conductance tympanometry (2-kHz PW) were assessed. Results: Seventy percent in group 1, 66.7% in group 2, and 78.3% in group 3 demonstrated double peaks at 2 kHz. The mean 2-kHz PW values were 157.52 ± 79.19, 177.40 ± 79.14, and 139.64 ± 87.501 daPa for groups 1, 2, and 3, respectively. There were no significant differences between groups with respect to 2-kHz PW, RF, absorbance, LF-A, and HF-A. Conclusion: This was the first study that evaluated the effects of acute Ménière attacks on WBT findings. An acute Ménière attack was found to have no significant effect on the 2-kHz PW and other variables measured using WBT.