Journal of the International Federation of Clinical Chemistry最新文献

筛选
英文 中文
The expanding role of robotics in the clinical laboratory. 机器人技术在临床实验室中的作用日益扩大。
K Ozawa, P Schnipelsky, H L Pardue, J Place, A Truchaud
{"title":"The expanding role of robotics in the clinical laboratory.","authors":"K Ozawa, P Schnipelsky, H L Pardue, J Place, A Truchaud","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1992-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A review of methodology for estrogen and progesterone receptor protein analysis. 雌激素和孕激素受体蛋白分析方法综述。
C J Menendez-Botet, M K Schwartz
{"title":"A review of methodology for estrogen and progesterone receptor protein analysis.","authors":"C J Menendez-Botet, M K Schwartz","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1992-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21019865","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A calibrator for the determination of the erythrocyte concentration in electronic blood cell counting. 电子血细胞计数中测定红细胞浓度的校准器。
P W Helleman
{"title":"A calibrator for the determination of the erythrocyte concentration in electronic blood cell counting.","authors":"P W Helleman","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A stable calibrator, suitable for the quality control of electronic counting of erythrocytes, has been developed. The assigned concentration is determined by the cooperation of six laboratories using various types of blood cell counting instruments. The performance of the instruments was checked prior to operation. If required, corrections were applied, and deviations were taken into account. The suitability of the calibrator was tested in practice during a period of several years. The applicability of the preparation as a calibrator for use in routine practice was tested in 14 laboratories.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1992-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020639","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of time and storage conditions of Chemstrip bG on estimating blood glucose aboard ambulances. 时间和储存条件对救护车上血糖测定的影响。
R D Herr
{"title":"Effect of time and storage conditions of Chemstrip bG on estimating blood glucose aboard ambulances.","authors":"R D Herr","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This study tested the hypothesis that the age of Chemstrip bG aboard ambulances is not associated with decline of accuracy. This was accomplished by removing and testing Chemstrips bG from ambulances in Salt Lake City, Utah, U.S.A. Chemstrips were developed with three concentrations of glucose (2.0, 3.8, 12.4 mmol/L; 35, 68, 223 mg/dL, respectively) in a blinded manner by three different researchers and compared with fresh controls and with the Dimension Analyzer-derived glucose. Results showed that older Chemstrips read significantly higher than fresh strips at each value of glucose tested (p less than 0.05). Increased age was associated with higher readings. Therefore, it is possible that cases of hypoglycemia may be missed by reliance on older Chemstrips. While fresh strips tended to underestimate glucose at 12.4 mmol/L, age and storage aboard ambulances tended to reverse this underestimation; older Chemstrips were associated with a more accurate reading at 12.4 mmol/L. Older age was also associated with increased standard deviation of Chemstrips. Unless this bias is considered in clinical practice, it might result in a failure to detect and treat a patient with hypoglycemia. Chemstrips aboard ambulances should be interpreted with caution when evaluating a patient on the threshold of hypoglycemia. Meanwhile, institution of a quality control program is indicated. This would include periodic testing, but might also include storage of Chemstrips, when not in use, in a climate-controlled area either on or off the ambulance.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1992-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020643","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The why and how of theophylline assay. 茶碱测定的原因和方法。
I D Watson
{"title":"The why and how of theophylline assay.","authors":"I D Watson","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1992-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020642","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Dry reagent measuring systems. 干试剂测量系统。
R S Campbell, C P Price
{"title":"Dry reagent measuring systems.","authors":"R S Campbell,&nbsp;C P Price","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1991-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020959","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Standardization of IgE antibody assays. IgE抗体检测标准化。
L Yman
{"title":"Standardization of IgE antibody assays.","authors":"L Yman","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1991-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020958","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The significance of the International Normalized Ratio (INR) for oral anticoagulant therapy. 国际标准化比值(INR)在口服抗凝治疗中的意义。
A M van den Besselaar
{"title":"The significance of the International Normalized Ratio (INR) for oral anticoagulant therapy.","authors":"A M van den Besselaar","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>For the laboratory control of oral anticoagulant treatment, the prothrombin time (PT) is used universally as the primary measurement. Important variability of the PT ratio (patient PT: mean health persons' PT) caused by different brands and batches of thromboplastin and instruments exists not only in North America, but throughout the world. To achieve uniformity of reporting, it is recommended that the PT ratio be transformed to the International Normalized Ratio (INR). This is possible if the thromboplastin manufacturer provides calibration data for each batch of thromboplastin. The INR scale facilitates the achievement of consensus on optimal therapeutic ranges for various clinical conditions. The INR will further improve the stability of anticoagulant treatment of travelling patients.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29289962","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The quality of cholesterol tests from finger prick blood with physicians' office equipment. The need for rigid quality control and proper interaction. 用医师办公室仪器检测手指刺血胆固醇的质量。需要严格的质量控制和适当的相互作用。
G J Boerma
{"title":"The quality of cholesterol tests from finger prick blood with physicians' office equipment. The need for rigid quality control and proper interaction.","authors":"G J Boerma","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21021925","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
New whole blood methods and instruments: glucose measurement and test menus for critical care. 新的全血方法和仪器:用于重症监护的葡萄糖测量和测试菜单。
G J Kost, D A Wiese, T P Bowen
{"title":"New whole blood methods and instruments: glucose measurement and test menus for critical care.","authors":"G J Kost,&nbsp;D A Wiese,&nbsp;T P Bowen","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A glucose oxidase-H 2O 2 substrate-selective electrode (SSE) along with eight other electrodes allows the Stat Profile 5 (SP5) to measure glucose, electrolytes, blood gases, pH, and hematocrit simultaneously in whole blood. For heparinized blood gas syringe samples (n=178), orthogonal (Deming) regression showed y=0.43 + 1.00x (mmol/L), where y is whole blood glucose, and x is plasma glucose measured with the Ektachem 400 glucose oxidase slide method. For heparinized plasma (n=197), y=0.25 + 1.02x. Least squares linear regression showed y=0.25 + 1.00x (s yxx=0.49) for whole blood versus plasma, y = 0.30 + 1.01x (s yxx=0.49) for plasma versus plasma, and r=0.994 for both cases. Whole blood and plasma glucose in the same samples measured by SSE differed by less than 1%. The SP5 combines the largest number of whole blood tests currently available in a rapid response instrument well-suited for care of the critically ill patient.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21021927","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信