{"title":"新的全血方法和仪器:用于重症监护的葡萄糖测量和测试菜单。","authors":"G J Kost, D A Wiese, T P Bowen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A glucose oxidase-H 2O 2 substrate-selective electrode (SSE) along with eight other electrodes allows the Stat Profile 5 (SP5) to measure glucose, electrolytes, blood gases, pH, and hematocrit simultaneously in whole blood. For heparinized blood gas syringe samples (n=178), orthogonal (Deming) regression showed y=0.43 + 1.00x (mmol/L), where y is whole blood glucose, and x is plasma glucose measured with the Ektachem 400 glucose oxidase slide method. For heparinized plasma (n=197), y=0.25 + 1.02x. Least squares linear regression showed y=0.25 + 1.00x (s yxx=0.49) for whole blood versus plasma, y = 0.30 + 1.01x (s yxx=0.49) for plasma versus plasma, and r=0.994 for both cases. Whole blood and plasma glucose in the same samples measured by SSE differed by less than 1%. The SP5 combines the largest number of whole blood tests currently available in a rapid response instrument well-suited for care of the critically ill patient.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New whole blood methods and instruments: glucose measurement and test menus for critical care.\",\"authors\":\"G J Kost, D A Wiese, T P Bowen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A glucose oxidase-H 2O 2 substrate-selective electrode (SSE) along with eight other electrodes allows the Stat Profile 5 (SP5) to measure glucose, electrolytes, blood gases, pH, and hematocrit simultaneously in whole blood. For heparinized blood gas syringe samples (n=178), orthogonal (Deming) regression showed y=0.43 + 1.00x (mmol/L), where y is whole blood glucose, and x is plasma glucose measured with the Ektachem 400 glucose oxidase slide method. For heparinized plasma (n=197), y=0.25 + 1.02x. Least squares linear regression showed y=0.25 + 1.00x (s yxx=0.49) for whole blood versus plasma, y = 0.30 + 1.01x (s yxx=0.49) for plasma versus plasma, and r=0.994 for both cases. Whole blood and plasma glucose in the same samples measured by SSE differed by less than 1%. The SP5 combines the largest number of whole blood tests currently available in a rapid response instrument well-suited for care of the critically ill patient.</p>\",\"PeriodicalId\":80043,\"journal\":{\"name\":\"Journal of the International Federation of Clinical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the International Federation of Clinical Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Federation of Clinical Chemistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New whole blood methods and instruments: glucose measurement and test menus for critical care.
A glucose oxidase-H 2O 2 substrate-selective electrode (SSE) along with eight other electrodes allows the Stat Profile 5 (SP5) to measure glucose, electrolytes, blood gases, pH, and hematocrit simultaneously in whole blood. For heparinized blood gas syringe samples (n=178), orthogonal (Deming) regression showed y=0.43 + 1.00x (mmol/L), where y is whole blood glucose, and x is plasma glucose measured with the Ektachem 400 glucose oxidase slide method. For heparinized plasma (n=197), y=0.25 + 1.02x. Least squares linear regression showed y=0.25 + 1.00x (s yxx=0.49) for whole blood versus plasma, y = 0.30 + 1.01x (s yxx=0.49) for plasma versus plasma, and r=0.994 for both cases. Whole blood and plasma glucose in the same samples measured by SSE differed by less than 1%. The SP5 combines the largest number of whole blood tests currently available in a rapid response instrument well-suited for care of the critically ill patient.