Analytical Chemistry Insights最新文献

筛选
英文 中文
A validated reverse phase HPLC method for the determination of disodium EDTA in meropenem drug substance with UV-detection using precolumn derivatization technique. 利用柱前衍生技术,建立了一种有效的反相高效液相色谱法,用紫外检测法测定美罗培南药物中的乙二胺四乙酸二钠。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-02-23 DOI: 10.4137/ACI.S5953
Bhavil Narola, A S Singh, M Mitra, P R Santhakumar, T G Chandrashekhar
{"title":"A validated reverse phase HPLC method for the determination of disodium EDTA in meropenem drug substance with UV-detection using precolumn derivatization technique.","authors":"Bhavil Narola, A S Singh, M Mitra, P R Santhakumar, T G Chandrashekhar","doi":"10.4137/ACI.S5953","DOIUrl":"10.4137/ACI.S5953","url":null,"abstract":"<p><p>This paper deals with development and validation of a high performance liquid chromatographic method for the quantitative determination of disodium EDTA (Ethylenediaminetetraacetic acid) in Meropenem active pharmaceutical ingredient (API). EDTA was derivatized with Ferric chloride solution by heating at 70 °C in water bath for about 20 minutes and the chromatographic separation achieved by injecting 100 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a Phenomenex Luna C18(2) column (250 × 4.6 mm), 5 μ. The mobile phase consisting of 5% methanol and 95% of 0.7 g/L solution of Tetra butyl ammonium bromide and 4.6 g/L solution of sodium acetate trihydrate in water (pH adjusted to 4.0 with the help of acetic acid glacial) and a flow rate of 1 milliliter/minute. EDTA eluted at approximately 6 minutes. The method was suitably validated with respect to specificity, linearity of response, precision, accuracy, ruggedness, stability in analytical solution, limit of quantitation and detection and robustness for its intended use.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"7-14"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3074208/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29863297","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
New spectrophotometric method for determining nitrogen dioxide in air using 2,2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt and passive sampling. 使用 2,2-叠氮-双(3-乙基苯并噻唑啉)-6-磺酸二铵盐和被动采样测定空气中二氧化氮的新型分光光度法。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-05-29 DOI: 10.4137/ACI.S6969
Alaa A Salem, Ahmed A Soliman, Ismail A El-Haty
{"title":"New spectrophotometric method for determining nitrogen dioxide in air using 2,2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt and passive sampling.","authors":"Alaa A Salem, Ahmed A Soliman, Ismail A El-Haty","doi":"10.4137/ACI.S6969","DOIUrl":"10.4137/ACI.S6969","url":null,"abstract":"<p><p>A new simple and highly sensitive spectrophotometric method for determining nitrogen dioxide in air was developed. The method is based on converting atmospheric nitrogen dioxide to nitrite ions within the IVL passive samplers used for samples collection. Acidifying nitrite ions with concentrated HCl produced the peroxynitrous acid oxidizing agent which was measured using 2, 2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt (ABTS) as reducing coloring agent. A parallel series of collected samples were measured for its nitrite content using a validated ion chromatographic method.The results obtained using both methods were compared in terms of their sensitivity and accuracy. Developed spectrophotometric method was shown to be one order of magnitude higher in sensitivity compared to the ion chromatographic method. Quantitation limits of 0.05 ppm and 0.55 μg/m(3) were obtained for nitrite ion and nitrogen dioxid, respectively. Standard deviations in the ranges of 0.05-0.59 and 0.63-7.92 with averages of 0.27 and 3.11 were obtained for determining nitrite and nitrogen dioxide, respectively.Student-t test revealed t-values less than 6.93 and 4.40 for nitrite ions and nitrogen dioxide, respectively. These values indicated insignificant difference between the averages of the newly developed method and the values obtained by ion chromatography at 95% confidence level.Compared to continuous monitoring techniques, the newly developed method has shown simple, accurate, sensitive, inexpensive and reliable for long term monitoring of nitrogen dioxide in ambient air.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"37-44"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3117622/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29863300","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simultaneous determination of amlodipine and valsartan. 氨氯地平和缬沙坦的同时测定。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-08-28 DOI: 10.4137/ACI.S7282
Nashwah Gadallah Mohamed
{"title":"Simultaneous determination of amlodipine and valsartan.","authors":"Nashwah Gadallah Mohamed","doi":"10.4137/ACI.S7282","DOIUrl":"https://doi.org/10.4137/ACI.S7282","url":null,"abstract":"<p><p>A spectrophotometric method was developed for simultaneous determination of amlodipine (Aml) and valsartan (Val) without previous separation. In this method amlodipine in methanolic solution was determined using zero order UV spectrophotometry by measuring its absorbency at 360.5 nm without any interference from valsartan.Valsartan spectrum in zero order is totally overlapped with that of amlodipine. First, second and third derivative could not resolve the overlapped peaks.The first derivative of the ratio spectra technique was applied for the measurement of valsartan. The ratio spectrum was obtained by dividing the absorption spectrum of the mixture by that of amlodipine, so that the concentration of valsartan could be determined from the first derivative of the ratio spectrum at 290 nm. Quantification limits of amlodipine and valsartan were 10-80 μg/ml and 20-180 μg/ml respectively. The method was successfully applied for the quantitative determination of both drugs in bulk powder and pharmaceutical formulation.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"53-9"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/ACI.S7282","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30141689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 30
A simple and sensitive assay for measuring very small volumes of microprinted solutions. 一种简单而灵敏的测定方法,用于测量极小体积的微缩印刷溶液。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-08-31 DOI: 10.4137/ACI.S7827
Charles W Sokolik, Annie S Walker, Gary M Nishioka
{"title":"A simple and sensitive assay for measuring very small volumes of microprinted solutions.","authors":"Charles W Sokolik,&nbsp;Annie S Walker,&nbsp;Gary M Nishioka","doi":"10.4137/ACI.S7827","DOIUrl":"https://doi.org/10.4137/ACI.S7827","url":null,"abstract":"<p><p>This study describes an extremely sensitive and simple assay to measure small volumes of solutions, <1 nL. The assay takes advantage of the Sandell-Kolthoff reaction in which yellow cerium(IV) is reduced to colorless cerium(III) in the presence of arsenic(III) and catalytic quantities of iodide ion. The reaction is linear with respect to the rate of Ce(IV) reduction and the quantity of I(-) present. Typical assays can measure 10-100 picomoles of iodide in a sample. When I(-) is substituted for chloride ion in standard biological buffers, such as Tris-buffered saline, the assay can be used to determine the volume of solution printed in a microarray.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"61-6"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/ACI.S7827","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30141690","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Development and validation of spectrophotometric, atomic absorption and kinetic methods for determination of moxifloxacin hydrochloride. 开发和验证测定盐酸莫西沙星的分光光度法、原子吸收法和动力学法。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-11-07 DOI: 10.4137/ACI.S8090
Lobna M Abdellaziz, Mervat M Hosny
{"title":"Development and validation of spectrophotometric, atomic absorption and kinetic methods for determination of moxifloxacin hydrochloride.","authors":"Lobna M Abdellaziz, Mervat M Hosny","doi":"10.4137/ACI.S8090","DOIUrl":"10.4137/ACI.S8090","url":null,"abstract":"<p><p>Three simple spectrophotometric and atomic absorption spectrometric methods are developed and validated for the determination of moxifloxacin HCl in pure form and in pharmaceutical formulations. Method (A) is a kinetic method based on the oxidation of moxifloxacin HCl by Fe(3+) ion in the presence of 1,10 o-phenanthroline (o-phen). Method (B) describes spectrophotometric procedures for determination of moxifloxacin HCl based on its ability to reduce Fe (III) to Fe (II), which was rapidly converted to the corresponding stable coloured complex after reacting with 2,2' bipyridyl (bipy). The formation of the tris-complex formed in both methods (A) and (B) were carefully studied and their absorbance were measured at 510 and 520 nm respectively. Method (C) is based on the formation of ion- pair associated between the drug and bismuth (III) tetraiodide in acidic medium to form orange-red ion-pair associates. This associate can be quantitatively determined by three different procedures. The formed precipitate is either filtered off, dissolved in acetone and quantified spectrophotometrically at 462 nm (Procedure 1), or decomposed by hydrochloric acid, and the bismuth content is determined by direct atomic absorption spectrometric (Procedure 2). Also the residual unreacted metal complex in the filtrate is determined through its metal content using indirect atomic absorption spectrometric technique (procedure 3). All the proposed methods were validated according to the International Conference on Harmonization (ICH) guidelines, the three proposed methods permit the determination of moxifloxacin HCl in the range of (0.8-6, 0.8-4) for methods A and B, (16-96, 16-96 and 16-72) for procedures 1-3 in method C. The limits of detection and quantitation were calculated, the precision of the methods were satisfactory; the values of relative standard deviations did not exceed 2%. The proposed methods were successfully applied to determine the drug in its pharmaceutical formulations without interference from the common excipients. The results obtained by the proposed methods were comparable with those obtained by the reference method.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"67-78"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3239224/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30365441","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Conductimetric biosensor for the detection of uric Acid by immobilization uricase on nata de coco membrane-pt electrode. 将尿酸酶固定在椰脂膜-铂电极上的电导生物传感器检测尿酸。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-07-03 DOI: 10.4137/ACI.S7346
Ani Mulyasuryani, Arie Srihardiastutie
{"title":"Conductimetric biosensor for the detection of uric Acid by immobilization uricase on nata de coco membrane-pt electrode.","authors":"Ani Mulyasuryani,&nbsp;Arie Srihardiastutie","doi":"10.4137/ACI.S7346","DOIUrl":"https://doi.org/10.4137/ACI.S7346","url":null,"abstract":"<p><p>A conductimetric enzyme biosensor for uric acid detection has been developed. The uricase, as enzyme, is isolated from Candida utilis and immobilized on a nata de coco membrane-Pt electrode. The biosensor demonstrates a linear response to urate over the concentration range 1-6 ppm and has good selectivity properties. The response is affected by the membrane thickness and pH change in the range 7.5-9.5. The response time is three minutes in aqueous solutions and in human serum samples. Application of the biosensor to the determination of uric acid in human serum gave results that compared favourably with those obtained by medical laboratory. The operational stability of the biosensor was not less than three days and the relative error is smaller than 10%.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"47-51"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/ACI.S7346","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30035124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Low level determinations of methyl methanesulfonate and ethyl methanesulfonate impurities in emtricitabine active pharmaceutical ingredient by LC/MS/MS using electrospray ionization. 利用电喷雾离子化技术,通过 LC/MS/MS 低水平测定恩曲他滨活性药物成分中的甲基磺酸甲酯和甲基磺酸乙酯杂质。
Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-03-10 DOI: 10.4137/ACI.S6471
P R Kakadiya, T G Chandrashekhar, S Ganguly, D K Singh, V Singh
{"title":"Low level determinations of methyl methanesulfonate and ethyl methanesulfonate impurities in emtricitabine active pharmaceutical ingredient by LC/MS/MS using electrospray ionization.","authors":"P R Kakadiya, T G Chandrashekhar, S Ganguly, D K Singh, V Singh","doi":"10.4137/ACI.S6471","DOIUrl":"10.4137/ACI.S6471","url":null,"abstract":"<p><p>Alkyl methanesulfonates have been highlighted as potential genotoxic impurities (PGIs). A sensitive LC/MS/MS method was developed and validated for the determination of Alkyl methanesulfonate impurities in Emtricitabine API (active pharmaceutical ingredient). LC/MS/MS method on Zorbax SB C(18) column (150 × 4.6 mm i.d.), 3.5 μm, with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode was used. The proposed method was specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.0025 μg/ml to 0.3 μg/ml the correlation coefficient was >0.999 in each case. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.3 μg/g and 0.4 μg/g respectively for both the analytes. Accuracy was observed within 80%-120% for both the analytes. This method can be further extended a good quality control tool for low level quantitation of Alkyl methanesulfonate impurities in other API.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"6 ","pages":"21-8"},"PeriodicalIF":0.0,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3074210/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29863298","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
New Title 4760 新标题4760
Analytical Chemistry Insights Pub Date : 2010-11-01 DOI: 10.4137/ACI.S4760
Ahmed
{"title":"New Title 4760","authors":"Ahmed","doi":"10.4137/ACI.S4760","DOIUrl":"https://doi.org/10.4137/ACI.S4760","url":null,"abstract":"","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"39 1","pages":"47"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77848630","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique. 建立了一种稳定指示反相高效液相色谱法测定盐酸美金刚原药的紫外柱前衍生技术。
Analytical Chemistry Insights Pub Date : 2010-07-20 DOI: 10.4137/aci.s3936
Bhavil Narola, A S Singh, P Rita Santhakumar, T G Chandrashekhar
{"title":"A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique.","authors":"Bhavil Narola,&nbsp;A S Singh,&nbsp;P Rita Santhakumar,&nbsp;T G Chandrashekhar","doi":"10.4137/aci.s3936","DOIUrl":"https://doi.org/10.4137/aci.s3936","url":null,"abstract":"<p><p>This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC) and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 muL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 x 4.6 mm), 5 mu. The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N) hydrochloric acid), base (1.0 N sodium hydroxide), oxidation (30% hydrogen peroxide), thermal (105 degrees C), photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%), linearity (linearity of range about 70-130 mug/mL), ruggedness (Overall % RSD about 0.35%), stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min.) and robustness.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"5 ","pages":"37-45"},"PeriodicalIF":0.0,"publicationDate":"2010-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/aci.s3936","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29185652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 36
Cell-free expression of protein kinase a for rapid activity assays. 蛋白激酶a快速活性测定的无细胞表达。
Analytical Chemistry Insights Pub Date : 2010-05-19 DOI: 10.4137/aci.s4732
Donna M Leippe, Kate Qin Zhao, Kevin Hsiao, Michael R Slater
{"title":"Cell-free expression of protein kinase a for rapid activity assays.","authors":"Donna M Leippe,&nbsp;Kate Qin Zhao,&nbsp;Kevin Hsiao,&nbsp;Michael R Slater","doi":"10.4137/aci.s4732","DOIUrl":"https://doi.org/10.4137/aci.s4732","url":null,"abstract":"<p><p>Functional protein analysis often calls for lengthy, laborious in vivo protein expression and purification, and can be complicated by the lack of stability of the purified protein. In this study, we demonstrate the feasibility of a simplified procedure for functional protein analysis on magnetic particles using cell-free protein synthesis of the catalytic subunit of human cAMP-dependent protein kinase as a HaloTag((R)) fusion protein. The cell-free protein synthesis systems provide quick access to the protein of interest, while the HaloTag technology provides efficient, covalent protein immobilization of the fusion protein, eliminating the need for further protein purification and minimizing storage-related stability issues. The immobilized cPKA fusion protein is assayed directly on magnetic beads and can be used in inhibitor analyses. The combination of rapid protein synthesis and capture technologies can greatly facilitate the process of protein expression and activity screening, and therefore, can become a valuable tool for functional proteomics studies.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"5 ","pages":"25-36"},"PeriodicalIF":0.0,"publicationDate":"2010-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/aci.s4732","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"29031902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信