New spectrophotometric method for determining nitrogen dioxide in air using 2,2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt and passive sampling.

Analytical Chemistry Insights Pub Date : 2011-01-01 Epub Date: 2011-05-29 DOI:10.4137/ACI.S6969
Alaa A Salem, Ahmed A Soliman, Ismail A El-Haty
{"title":"New spectrophotometric method for determining nitrogen dioxide in air using 2,2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt and passive sampling.","authors":"Alaa A Salem, Ahmed A Soliman, Ismail A El-Haty","doi":"10.4137/ACI.S6969","DOIUrl":null,"url":null,"abstract":"<p><p>A new simple and highly sensitive spectrophotometric method for determining nitrogen dioxide in air was developed. The method is based on converting atmospheric nitrogen dioxide to nitrite ions within the IVL passive samplers used for samples collection. Acidifying nitrite ions with concentrated HCl produced the peroxynitrous acid oxidizing agent which was measured using 2, 2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt (ABTS) as reducing coloring agent. A parallel series of collected samples were measured for its nitrite content using a validated ion chromatographic method.The results obtained using both methods were compared in terms of their sensitivity and accuracy. Developed spectrophotometric method was shown to be one order of magnitude higher in sensitivity compared to the ion chromatographic method. Quantitation limits of 0.05 ppm and 0.55 μg/m(3) were obtained for nitrite ion and nitrogen dioxid, respectively. Standard deviations in the ranges of 0.05-0.59 and 0.63-7.92 with averages of 0.27 and 3.11 were obtained for determining nitrite and nitrogen dioxide, respectively.Student-t test revealed t-values less than 6.93 and 4.40 for nitrite ions and nitrogen dioxide, respectively. These values indicated insignificant difference between the averages of the newly developed method and the values obtained by ion chromatography at 95% confidence level.Compared to continuous monitoring techniques, the newly developed method has shown simple, accurate, sensitive, inexpensive and reliable for long term monitoring of nitrogen dioxide in ambient air.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3117622/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/ACI.S6969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/5/29 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A new simple and highly sensitive spectrophotometric method for determining nitrogen dioxide in air was developed. The method is based on converting atmospheric nitrogen dioxide to nitrite ions within the IVL passive samplers used for samples collection. Acidifying nitrite ions with concentrated HCl produced the peroxynitrous acid oxidizing agent which was measured using 2, 2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt (ABTS) as reducing coloring agent. A parallel series of collected samples were measured for its nitrite content using a validated ion chromatographic method.The results obtained using both methods were compared in terms of their sensitivity and accuracy. Developed spectrophotometric method was shown to be one order of magnitude higher in sensitivity compared to the ion chromatographic method. Quantitation limits of 0.05 ppm and 0.55 μg/m(3) were obtained for nitrite ion and nitrogen dioxid, respectively. Standard deviations in the ranges of 0.05-0.59 and 0.63-7.92 with averages of 0.27 and 3.11 were obtained for determining nitrite and nitrogen dioxide, respectively.Student-t test revealed t-values less than 6.93 and 4.40 for nitrite ions and nitrogen dioxide, respectively. These values indicated insignificant difference between the averages of the newly developed method and the values obtained by ion chromatography at 95% confidence level.Compared to continuous monitoring techniques, the newly developed method has shown simple, accurate, sensitive, inexpensive and reliable for long term monitoring of nitrogen dioxide in ambient air.

Abstract Image

Abstract Image

Abstract Image

使用 2,2-叠氮-双(3-乙基苯并噻唑啉)-6-磺酸二铵盐和被动采样测定空气中二氧化氮的新型分光光度法。
开发了一种新的简单、高灵敏度的分光光度法来测定空气中的二氧化氮。该方法的基础是在用于采集样品的 IVL 被动采样器内将大气中的二氧化氮转化为亚硝酸根离子。用浓盐酸酸化亚硝酸离子,产生过硝酸氧化剂,用 2,2-氮基-双(3-乙基苯并噻唑啉)-6-磺酸二铵盐(ABTS)作为还原着色剂进行测定。同时,对收集到的一系列样品使用有效的离子色谱法测量亚硝酸盐含量。结果表明,所开发的分光光度法的灵敏度比离子色谱法高一个数量级。亚硝酸离子和二氧 化氮的定量限分别为 0.05 ppm 和 0.55 μg/m(3)。亚硝酸盐和二氧化氮的标准偏差分别为 0.05-0.59 和 0.63-7.92,平均值分别为 0.27 和 3.11。学生 t 检验显示,亚硝酸盐离子和二氧化氮的 t 值分别小于 6.93 和 4.40。与连续监测技术相比,新开发的方法简便、准确、灵敏、价廉且可靠,可用于长期监测环境空气中的二氧化氮。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信