Medical instrumentation最新文献

筛选
英文 中文
Possible red blood cell damage due to iatrogenic transfusion filter-related mistakes during blood transfusion 输血过程中医源性输血过滤器相关错误可能造成的红细胞损伤
Medical instrumentation Pub Date : 2013-06-28 DOI: 10.7243/2052-6962-1-4
H. Fujita, R. Sakuma, S. Nishimura
{"title":"Possible red blood cell damage due to iatrogenic transfusion filter-related mistakes during blood transfusion","authors":"H. Fujita, R. Sakuma, S. Nishimura","doi":"10.7243/2052-6962-1-4","DOIUrl":"https://doi.org/10.7243/2052-6962-1-4","url":null,"abstract":"Abstract \u0000Background: Red cell concentrates are usually transfused through a transfusion filter. Iatrogenic accidents can occur in which the red blood cell concentrate is transfused through the infusion filter by","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"1 1","pages":"4"},"PeriodicalIF":0.0,"publicationDate":"2013-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71382460","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Substantial difference between declared and real magnification in medical loupes 医用放大镜声明放大倍率与实际放大倍率之间的实质性差异
Medical instrumentation Pub Date : 2013-05-24 DOI: 10.7243/2052-6962-1-2
K. Neuhaus, P. Perrin, A. Lussi
{"title":"Substantial difference between declared and real magnification in medical loupes","authors":"K. Neuhaus, P. Perrin, A. Lussi","doi":"10.7243/2052-6962-1-2","DOIUrl":"https://doi.org/10.7243/2052-6962-1-2","url":null,"abstract":"Abstract \u0000Background: The use of magnification devices is widely recommended in surgical disciplines, but a validation of the respective optical aids, i.e., medical loupe systems, is","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"1 1","pages":"2"},"PeriodicalIF":0.0,"publicationDate":"2013-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71382431","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Use of depth dependent attenuation characteristics of thermal energy deposition to increase spatial uniformity of HIFU ablation in large uterine fibroids 利用热能沉积的深度依赖衰减特性增加大子宫肌瘤HIFU消融的空间均匀性
Medical instrumentation Pub Date : 2013-05-07 DOI: 10.7243/2052-6962-1-1
S. Z. Ismail, M. Bilgen
{"title":"Use of depth dependent attenuation characteristics of thermal energy deposition to increase spatial uniformity of HIFU ablation in large uterine fibroids","authors":"S. Z. Ismail, M. Bilgen","doi":"10.7243/2052-6962-1-1","DOIUrl":"https://doi.org/10.7243/2052-6962-1-1","url":null,"abstract":"Abstract \u0000Purpose: In high intensity focused ultrasound (HIFU) treatment of large fibroid, depth dependent attenuation of thermal deposition leads to insufficient temperature rise for necrosis in deeper tissue. The","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 1","pages":"1"},"PeriodicalIF":0.0,"publicationDate":"2013-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71382429","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Human factors and design evaluation of digital blood pressure/pulse meters. 数字血压/脉搏仪的人为因素及设计评价。
Medical instrumentation Pub Date : 1988-10-01
D W Harrison, P M Gorelczenko, P L Kelly
{"title":"Human factors and design evaluation of digital blood pressure/pulse meters.","authors":"D W Harrison,&nbsp;P M Gorelczenko,&nbsp;P L Kelly","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This study provides a comparison of self-measurement blood pressure devices, with respect to the standards published by the American National Standards Institute/Association for the Advancement of Medical Instrumentation and statements from the American Heart Association and the National High Blood Pressure Education Program. The results show a wide disparity among the recommendations of select committees, on issues of education and compliance and on design features of this instrumentation. Procedural problems in determining compliance in this study highlight the need for improved objectivity in statements in national standards and for improved awareness of those statements by manufacturers.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"226-9"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14315117","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Implementation of a home-based program for early detection of clinical deterioration in cystic fibrosis. 实施以家庭为基础的方案,早期发现囊性纤维化的临床恶化。
Medical instrumentation Pub Date : 1988-10-01
L J Brown-Ewing, S M Finkelstein, J R Budd, S J Kujawa, C L Wielinski, W J Warwick, S Nguyen
{"title":"Implementation of a home-based program for early detection of clinical deterioration in cystic fibrosis.","authors":"L J Brown-Ewing,&nbsp;S M Finkelstein,&nbsp;J R Budd,&nbsp;S J Kujawa,&nbsp;C L Wielinski,&nbsp;W J Warwick,&nbsp;S Nguyen","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A statistical decision-making system, based on daily self measurements obtained at home, has been developed that will predict the clinical status of a patient with cystic fibrosis (CF). The data for the study were collected from patients randomly selected from those served by the University of Minnesota CF Center. Participants recorded four daily measurements (weight, vital capacity, breathing rate, and resting pulse) and one weekly measurement (height) and returned completed diaries to the coordinating center each week. The goal of the rule was to determine whether each patient's clinical status was deteriorating, remaining stable, or improving at the time of the most recent set of weekly measurements. This early detection and intervention criterion (EDIC) is being used in the clinical setting to aid in the management of patients with cystic fibrosis. The computer hardware and software, particularly the relational database, have provided an efficient basis for the continued use of EDIC.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"240-6"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14314934","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The use of high technology for health care at home: issues and implications. 在家庭保健中使用高技术:问题和影响。
Medical instrumentation Pub Date : 1988-10-01
P S Liebig
{"title":"The use of high technology for health care at home: issues and implications.","authors":"P S Liebig","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Advances in technology and treatment have resulted in a growing population of very old and very young people whose lives are technology dependent. These people are being cared for in increasing numbers in their homes by care-givers inadequately trained for the task. The unintended negative consequences and the positive effects of such care are examined, and ethical concerns are raised.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"222-5"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14186540","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Blood pressure reactivity and bias vary with age in a comparison of traditional and automated methods of measurement. 在传统和自动化测量方法的比较中,血压的反应性和偏差随年龄的变化而变化。
Medical instrumentation Pub Date : 1988-10-01
D W Harrison, M C Edwards
{"title":"Blood pressure reactivity and bias vary with age in a comparison of traditional and automated methods of measurement.","authors":"D W Harrison,&nbsp;M C Edwards","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This study examined the effects of initial-reading reactivity and measurement methods of blood pressure across different age groups. Subjects were men and women (n = 132), 17 to 96 years of age. Two measurements were obtained from each subject, with a 1-min interval between trials. Each trial consisted of concurrent measurements from each arm, using a standard mercury manometer and an automated blood pressure monitor for use at home. A double-blind control procedure was used. Significant effects were obtained for age (younger, middle, and older age groups), method by trial and age by trial. The blood pressure reactivity and the effect of observer bias varied across age groups. The results support the hypotheses that blood pressure readings decline across trials; that observer bias using traditional methods is sufficient to mask this decline; and that the extent of reactivity and subsequent decline is dependent on age or an age-related increase in blood pressure. Implications of these findings for the use of automated monitoring instruments designed for use at home are discussed.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"230-3"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14315118","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fabrication of key components of a receptor-based biosensor. 基于受体的生物传感器关键元件的制备。
Medical instrumentation Pub Date : 1988-10-01
F S Ligler, T L Fare, K D Seib, J W Smuda, A Singh, P Ahl, M E Ayers, A Dalziel, P Yager
{"title":"Fabrication of key components of a receptor-based biosensor.","authors":"F S Ligler,&nbsp;T L Fare,&nbsp;K D Seib,&nbsp;J W Smuda,&nbsp;A Singh,&nbsp;P Ahl,&nbsp;M E Ayers,&nbsp;A Dalziel,&nbsp;P Yager","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A three-pronged approach was taken to the development of receptor-based bisensors. First, asymmetric bilayer membranes were developed with one monolayer adaptable to the particular receptor of interest and the other monolayer polymerized to enhance membrane stability. Second, alamethicin and calcium channel complexes were introduced into the stabilized membrane and tested for ion-channel function. Third, a porous support for the receptor-containing membrane was fabricated, which is compatible with silicon technology. Preliminary devices incorporating these components were constructed.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"247-56"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13983879","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Nurses' attitudes toward conventional and automated vital signs measurement methods. 护士对常规和自动化生命体征测量方法的态度。
Medical instrumentation Pub Date : 1988-10-01
N Campbell-Heider, T R Knapp
{"title":"Nurses' attitudes toward conventional and automated vital signs measurement methods.","authors":"N Campbell-Heider,&nbsp;T R Knapp","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The acceptance and assimilation of new medical technologies into the health-care arena is a complex process involving financial, humanistic, and clinical considerations. This experimental research compared nurses' attitudes regarding the clinical acceptability of conventional methods of measuring vital signs with their attitudes toward a new, automated method, using the IVAC Model 4000 Vital-Check. Two studies were conducted, at different university-affiliated hospitals, involving different nursing-care-delivery models. The 102 nurses who participated in the studies generally favored the automated method with respect to provider convenience, patient acceptance, and the opportunity to simultaneously perform other nursing assessments. Conventional techniques were preferred for patients on isolation precautions and in some very specific clinical situations such as those requiring detection of abnormalities in the heart rhythm. Interviews of patients were also conducted at both sites and their comments supplemented and supported the quantitative findings for the nurses. Patients seemed to adapt very well to the new technology. They were particularly interested in being better able to monitor their own measurements with the automated process.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"257-62"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14314935","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrically produced artificial ventilation. 用电产生的人工通风。
Medical instrumentation Pub Date : 1988-10-01
L A Geddes, W D Voorhees, R Lagler, C Riscili, K Foster, J D Bourland
{"title":"Electrically produced artificial ventilation.","authors":"L A Geddes,&nbsp;W D Voorhees,&nbsp;R Lagler,&nbsp;C Riscili,&nbsp;K Foster,&nbsp;J D Bourland","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The induction of inspiration by delivering a burst of short-duration stimuli to body-surface electrodes is over a century old. The authors have used the term electroventilation to describe the technique. Inspiration can be produced with stimuli applied to electrodes placed bilaterally at the base of the neck, over the phrenic nerve motor points. Transchest electrodes placed anterior to the axillae can be used to stimulate the long thoracic and phrenic nerves. Paraxiphoid electrodes can be used to stimulate the phrenic nerves as they enter the diaphragm. With any of these electrode placements, inspired volumes in excess of spontaneous tidal volumes can be achieved in man, baboon, and dog. Of major importance is the need to use short-duration (less than 10-microseconds) pulses in the train of stimuli that produces contraction of the inspiratory muscles. The duration of inspiration is determined by the duration of the train, which is typically 0.5-1 s. The use of short-duration pulses minimizes the risk of producing cardiac arrhythmias and results in very little sensation at the skin.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"263-71"},"PeriodicalIF":0.0,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14186541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书