用电产生的人工通风。

Medical instrumentation Pub Date : 1988-10-01
L A Geddes, W D Voorhees, R Lagler, C Riscili, K Foster, J D Bourland
{"title":"用电产生的人工通风。","authors":"L A Geddes,&nbsp;W D Voorhees,&nbsp;R Lagler,&nbsp;C Riscili,&nbsp;K Foster,&nbsp;J D Bourland","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The induction of inspiration by delivering a burst of short-duration stimuli to body-surface electrodes is over a century old. The authors have used the term electroventilation to describe the technique. Inspiration can be produced with stimuli applied to electrodes placed bilaterally at the base of the neck, over the phrenic nerve motor points. Transchest electrodes placed anterior to the axillae can be used to stimulate the long thoracic and phrenic nerves. Paraxiphoid electrodes can be used to stimulate the phrenic nerves as they enter the diaphragm. With any of these electrode placements, inspired volumes in excess of spontaneous tidal volumes can be achieved in man, baboon, and dog. Of major importance is the need to use short-duration (less than 10-microseconds) pulses in the train of stimuli that produces contraction of the inspiratory muscles. The duration of inspiration is determined by the duration of the train, which is typically 0.5-1 s. The use of short-duration pulses minimizes the risk of producing cardiac arrhythmias and results in very little sensation at the skin.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 5","pages":"263-71"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrically produced artificial ventilation.\",\"authors\":\"L A Geddes,&nbsp;W D Voorhees,&nbsp;R Lagler,&nbsp;C Riscili,&nbsp;K Foster,&nbsp;J D Bourland\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The induction of inspiration by delivering a burst of short-duration stimuli to body-surface electrodes is over a century old. The authors have used the term electroventilation to describe the technique. Inspiration can be produced with stimuli applied to electrodes placed bilaterally at the base of the neck, over the phrenic nerve motor points. Transchest electrodes placed anterior to the axillae can be used to stimulate the long thoracic and phrenic nerves. Paraxiphoid electrodes can be used to stimulate the phrenic nerves as they enter the diaphragm. With any of these electrode placements, inspired volumes in excess of spontaneous tidal volumes can be achieved in man, baboon, and dog. Of major importance is the need to use short-duration (less than 10-microseconds) pulses in the train of stimuli that produces contraction of the inspiratory muscles. The duration of inspiration is determined by the duration of the train, which is typically 0.5-1 s. The use of short-duration pulses minimizes the risk of producing cardiac arrhythmias and results in very little sensation at the skin.</p>\",\"PeriodicalId\":76133,\"journal\":{\"name\":\"Medical instrumentation\",\"volume\":\"22 5\",\"pages\":\"263-71\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical instrumentation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过向体表电极传递短时间的刺激来诱导灵感的方法已经有一个多世纪的历史了。作者使用术语“电通气”来描述这项技术。在双侧放置于颈部底部的膈神经运动点上方的电极上施加刺激可以产生灵感。放置在腋窝前的横切电极可以用来刺激胸长神经和膈神经。当膈神经进入横膈膜时,副轴状电极可以用来刺激膈神经。与任何这些电极放置,激发体积超过自发潮汐体积可以实现在人,狒狒和狗。最重要的是需要使用短时间(小于10微秒)的脉冲来刺激产生吸气肌的收缩。灵感的持续时间由列车的持续时间决定,通常为0.5-1秒。使用短时间脉冲可以最大限度地降低产生心律失常的风险,并且对皮肤的感觉很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrically produced artificial ventilation.

The induction of inspiration by delivering a burst of short-duration stimuli to body-surface electrodes is over a century old. The authors have used the term electroventilation to describe the technique. Inspiration can be produced with stimuli applied to electrodes placed bilaterally at the base of the neck, over the phrenic nerve motor points. Transchest electrodes placed anterior to the axillae can be used to stimulate the long thoracic and phrenic nerves. Paraxiphoid electrodes can be used to stimulate the phrenic nerves as they enter the diaphragm. With any of these electrode placements, inspired volumes in excess of spontaneous tidal volumes can be achieved in man, baboon, and dog. Of major importance is the need to use short-duration (less than 10-microseconds) pulses in the train of stimuli that produces contraction of the inspiratory muscles. The duration of inspiration is determined by the duration of the train, which is typically 0.5-1 s. The use of short-duration pulses minimizes the risk of producing cardiac arrhythmias and results in very little sensation at the skin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信