Biomaterials, medical devices, and artificial organs最新文献

筛选
英文 中文
Particulate aluminum oxide as a bone graft material. 颗粒氧化铝作为骨移植材料。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117547
R E Luedemann, K A Thomas, S D Cook
{"title":"Particulate aluminum oxide as a bone graft material.","authors":"R E Luedemann, K A Thomas, S D Cook","doi":"10.3109/10731198609117547","DOIUrl":"https://doi.org/10.3109/10731198609117547","url":null,"abstract":"The performance of particulate aluminum oxide (Al2O3) as a bone graft material was evaluated by comparison to two other graft materials, autogenous bone and particulate hydroxylapatite (HA). Holes were drilled through the medial cortex of both the distal femora and proximal tibiae in three dogs. The Al2O3, HA and autogenous bone were packed into the created defects and the rate and extent of defect healing examined. Particulate Al2O3 and HA were also placed on opposite sides of the median sacral crest in a spinal fusion procedure. One dog was sacrificed at 4, 8 and 12 weeks post-operative. The extent and rate of healing was superior with the autogenous bone, while the performance of the HA was superior to that of the Al2O3 at 4 and 8 weeks. However by 12 weeks, the performance of the two non-autogenous materials was equivalent. At 12 weeks the majority of the cancellous defect was infiltrated with viable bone with all three materials. In the spinal fusions, results were not as encouraging, with less bone present within the graft materials as compared to the cancellous defect implantations.","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"257-73"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117547","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14161237","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Abstracts. Fifth Southern Biomedical Engineering Conference. Shreveport, October 20-21, 1986. 摘要。第五届南方生物医学工程会议。什里夫波特,1986年10月20日至21日。
{"title":"Abstracts. Fifth Southern Biomedical Engineering Conference. Shreveport, October 20-21, 1986.","authors":"","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 1-2","pages":"1-152"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14886556","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Bone remodeling associated with a flexible femoral intramedullary implant. 柔性股骨髓内植入物相关的骨重塑。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117542
R E Luedemann, K A Thomas, S D Cook
{"title":"Bone remodeling associated with a flexible femoral intramedullary implant.","authors":"R E Luedemann,&nbsp;K A Thomas,&nbsp;S D Cook","doi":"10.3109/10731198609117542","DOIUrl":"https://doi.org/10.3109/10731198609117542","url":null,"abstract":"<p><p>The tissue response and bone remodeling associated with a flexible femoral intramedullary implant was evaluated. The implant consisted of wafers of porous Co-Cr-Mo alloy and microporous LTI pyrolytic carbon. Six wafers of each material were assembled in a stack and held together using a central acrylic rod. Radiography and histology demonstrated that these implants were associated with gross bone remodeling changes in the femoral shaft. The bone remodeling consisted of endosteal surface bone resorption and periosteal surface bone deposition, most likely due to a loss of structural support from the reamed medullary canal. The periosteal surface bone deposition resulted in an increase in femoral shaft diameter of 5% - 140%. The bone-implant interface consisted of a fibrous connective tissue with limited areas of bone ingrowth or bone apposition.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"181-94"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117542","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14933265","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
The effect of post-sintering heat treatments on the tensile properties of Ti-6A1-4V alloy. 烧结后热处理对Ti-6A1-4V合金拉伸性能的影响。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117541
S D Cook, R C Anderson, N Thongpreda, R J Haddad
{"title":"The effect of post-sintering heat treatments on the tensile properties of Ti-6A1-4V alloy.","authors":"S D Cook,&nbsp;R C Anderson,&nbsp;N Thongpreda,&nbsp;R J Haddad","doi":"10.3109/10731198609117541","DOIUrl":"https://doi.org/10.3109/10731198609117541","url":null,"abstract":"<p><p>Previous studies have shown that the application of a porous coating to a solid substrate offers several advantages over current methods of implant fixation. However, the heat treatments required to sinter porous metal coatings have also been shown to cause significant decreases in the mechanical properties of the substrate. With Ti-6A1-4V alloy, sintering above the material beta transus results in a transformation from the as-received, equiaxed microstructure, recommended for surgical implants, to a lamellar alpha-beta microstructure. This lamellar structure has been shown to have inferior mechanical properties. In the present study, microstructural analysis and mechanical testing were performed on Ti-6A1-4V alloy subjected to various post-sintering heat treatments in an attempt to improve the mechanical properties. The microstructures examined were a fine and a coarse acicular alpha in a retained beta matrix. Tensile tests were performed on specimens containing these structures and results were compared with the lamellar and equiaxed microstructures. The fine acicular alpha structure was shown to exhibit the best tensile properties for the post-sintering Ti-6A1-4V alloy microstructures examined, displaying a 9.8% elongation value, as compared to the as-received, equiaxed microstructure value of 13.5%. This represents a significant improvement over the 5.1% value obtained with the lamellar microstructure.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"167-80"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117541","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14933264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo. 体外合成血管假体生成C5a:对体内移植物结合的影响。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117546
R Sindhi
{"title":"In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo.","authors":"R Sindhi","doi":"10.3109/10731198609117546","DOIUrl":"https://doi.org/10.3109/10731198609117546","url":null,"abstract":"<p><p>C5a, released during activation of the complement cascade, was measured by radioimmunoassay in human plasma incubated with Dacron, preclotted Dacron, glutaraldehyde treated human umbilical vein (HUV), polytetrafluoroethylene (PTFE), and Dacron-collagen composite vascular grafts. Expressed as percent of C5a in control plasma incubated without graft, C5a generation by preclotted Dacron, and by the HUV was similar to that by Dacron (941 +/- 206% S.E.M.), while that due to PTFE was markedly less (p = 0.005). The Dacron-collagen composite vascular graft also generated significantly less C5a than Dacron and was similar to PTFE in this respect. These results expand on previous work suggesting that lower C5a generation by PTFE explained the negligible polymorphonuclear infiltrate seen on its surface in vivo, allowing it to endothelialise as rapidly as Dacron despite poorer attachment of seeded endothelial cells. The role of complement as a factor limiting endothelialisation of synthetic vascular prostheses needs further investigation.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"249-55"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117546","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14085416","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Osteogenesis induced by bone matrix is inhibited by inflammation. 骨基质诱导的成骨受到炎症的抑制。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117544
J Sela, J Applebaum, G Uretzky
{"title":"Osteogenesis induced by bone matrix is inhibited by inflammation.","authors":"J Sela,&nbsp;J Applebaum,&nbsp;G Uretzky","doi":"10.3109/10731198609117544","DOIUrl":"https://doi.org/10.3109/10731198609117544","url":null,"abstract":"<p><p>This study was designed to examine the effect of inflammatory reaction elicited by percutaneous tube on bone induction. Inflammation was provoked by different types of biomaterials. In order to evaluate incorporation of percutaneous tubes, bone matrix and subcutaneous tissue, demineralizing bone matrix was implanted in the subcutaneous tissue of rats and was exposed to interaction with inflammatory conditions. Inhibition to the induction of cartilage and bone by the inflammatory process could be clearly demonstrated. It is suggested that the low pH levels, typical to enzymes operative in inflammation are a direct cause for inhibition of chondro and osteogenesis. The process of calcification is characterized by the activation of enzymes in high pH levels.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"227-37"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117544","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14933267","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
Custom-made vaginal balloons for strengthening circumvaginal musculature. 为加强阴道周围肌肉组织定制的阴道气球。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117545
R M Abrams, C Batich, M C Dougherty, P L McKey, Y C Lin, J Parker
{"title":"Custom-made vaginal balloons for strengthening circumvaginal musculature.","authors":"R M Abrams,&nbsp;C Batich,&nbsp;M C Dougherty,&nbsp;P L McKey,&nbsp;Y C Lin,&nbsp;J Parker","doi":"10.3109/10731198609117545","DOIUrl":"https://doi.org/10.3109/10731198609117545","url":null,"abstract":"<p><p>A technique for making individualized silicone rubber intravaginal balloons is described. The method entails investing alginate vaginal impressions in silicone rubber and casting a resin model which is then dipped repeatedly in a Silastic Dispersion (Dow Corning, Q7-2213). The range of forces developed by circumvaginal muscles during maximum contractions was determined to be 0.5-4 lbs. Pressure-volume relationships of the balloons showed that the pressure of filling fluid was an accurate replica of the mean pressure in the vagina.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"239-48"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117545","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14930936","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Electrical conduction in bone in frequency range 0.4-1.3 GHz. 骨内的电传导频率范围为0.4-1.3 GHz。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117540
S Ray, J Behari
{"title":"Electrical conduction in bone in frequency range 0.4-1.3 GHz.","authors":"S Ray,&nbsp;J Behari","doi":"10.3109/10731198609117540","DOIUrl":"https://doi.org/10.3109/10731198609117540","url":null,"abstract":"<p><p>Dielectric permittivity and conductivity of bone in different physiological conditions and collagen, a major component of bone are measured in the frequency range 400-1300 MHz using a Network analyzer. The dielectric dispersion observed in each cases are explained in terms of the relaxation of 'bound water' in this frequency range. The relaxation frequency as well as distribution parameter are computed in each case, under certain simplifying conditions, hydration as well as static dielectric permittivity of bound water attached with bone in different physiological conditions and collagen are also calculated. The effect of ultraviolet light irradiation on the dielectric properties of bone in this frequency range is also examined. The change in dielectric properties due to radiation is attributed to the breakage of hydrogen bonds in the ring structure. A consistent physical model in line with other data is presented.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"153-65"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117540","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14933263","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Electronic antihemocoagulation. 电子antihemocoagulation。
Biomaterials, medical devices, and artificial organs Pub Date : 1986-01-01 DOI: 10.3109/10731198609117543
P A DeLangis, T F Yen
{"title":"Electronic antihemocoagulation.","authors":"P A DeLangis,&nbsp;T F Yen","doi":"10.3109/10731198609117543","DOIUrl":"https://doi.org/10.3109/10731198609117543","url":null,"abstract":"<p><p>The purpose of this study is to determine if the volume conduction of electrical current by blood can extend or possibly prevent clotting, and if so to determine where in the clotting sequence the effects occur. The important aspects of these based as follows: All cells and surfaces of the body carry an electrical charge. The magnitude of this surface charge is determined not only by the characteristics of the cells and particles themselves, but also by the liquid or solid in which they are immersed. The majority of the particles within the blood are negatively charged. Although the intima of the vascular system is negatively charged with respect to the adventitia of the vessel, trauma to the vessel will cause the negative charge to become zero or positive with a concomitant thrombosis at that point. An incision into a vessel will result in a positive voltage at the injury site. If the incision is kept negatively charged through application of an electrical current, coagulation at the site will be inhibited and the wound will ooze for many hours. If the current is reversed and made positive, clotting will accelerate. In the laboratory when two oppositely charged electrodes were cemmersed in a beaker of blood, a clot formed at the positive electrode only. If the procedure is carried out correctly, the blood surrounding the negative electrode will have highly effective anticoagulant properties. Furthermore, under similar conditions, leucocytes will migrate toward the negative electrode, thus indicating a change in cell polarity from negative to positive, possibly as a means to combat inflammation. A special bridge circuit and several original test cell designs were developed. Some of the results of this research are as follows: a means to electronically detect coagulation was devised; clotting was extended in excess of 400% by the application of electrical currents; currents below one milliamp per cm2 would not cause any noticeable trauma to the blood as determined by routine clinical laboratory methods. Analysis of the saline compartments resulted in the conclusion that there had not been any migration of the blood components into the saline. However, since the pore size would prohibit the migration of the blood components into the saline.(ABSTRACT TRUNCATED AT 400 WORDS)</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"14 3-4","pages":"195-225"},"PeriodicalIF":0.0,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198609117543","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14933266","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
In-vivo degradation of poly(lactic acid) of different molecular weights. 不同分子量聚乳酸的体内降解。
Biomaterials, medical devices, and artificial organs Pub Date : 1985-01-01 DOI: 10.3109/10731198509118848
A S Chawla, T M Chang
{"title":"In-vivo degradation of poly(lactic acid) of different molecular weights.","authors":"A S Chawla,&nbsp;T M Chang","doi":"10.3109/10731198509118848","DOIUrl":"https://doi.org/10.3109/10731198509118848","url":null,"abstract":"<p><p>Lactic acid was polymerized using tetraphenyl tin as a catalyst. The molecular weight of the resultant poly(lactic acid) varied between 0.89 X 10(6) and 2.94 X 10(6) depending upon the concentration of the catalyst used. In-vivo degradation of the poly(lactic acid) samples having 4 different molecular weights were studies by implanting these in Wistar rats. It was found that at the end of a 48-week implantation period lower molecular weight poly(lactic acid) samples were degraded at a faster rate than the higher molecular weight samples.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"13 3-4","pages":"153-62"},"PeriodicalIF":0.0,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198509118848","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14961550","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 50
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信