Waldemir F Vieira-Junior, Alexandre M Lucon, Núbia I P Pini, Mari M Sugii, Flávio H B Aguiar, Débora A N L Lima
{"title":"Effect of fluoride or chitosan toothpaste and at-home bleaching in enamel roughness, tooth color, and staining susceptibility.","authors":"Waldemir F Vieira-Junior, Alexandre M Lucon, Núbia I P Pini, Mari M Sugii, Flávio H B Aguiar, Débora A N L Lima","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate how fluoride- or chitosan-based toothpaste used during at-home bleaching affects enamel roughness, tooth color, and staining susceptibility.</p><p><strong>Methods: </strong>Bovine enamel blocks were submitted to a 14-day cycling regime considering a factorial design (bleaching agent x toothpaste, 2 x 3), with n=10: (1) bleaching with 16% carbamide peroxide (CP) or 6% hydrogen peroxide (HP), and (2) daily exposure of a fluoride (1,450 ppm F-NaF) toothpaste (FT), chitosan-based toothpaste (CBT), or distilled water (control). Then, 24 hours after the last day of bleaching procedure the samples were exposed to a coffee solution. Color (ΔEab, ΔE₀₀, L*, a*, b*) and roughness (Ra, µm) analyses were performed to compare the samples initially (baseline), after bleaching, and after coffee staining. The results were evaluated by linear models for repeated measures (L*, a*, b*, and Ra), 2-way ANOVA (ΔEab, ΔE₀₀) and Tukey's test (α= 0.05).</p><p><strong>Results: </strong>After the at-home bleaching procedure (toothpaste vs. time, P< 0.0001), the toothpaste groups presented a statistically lower Ra than the control (CBT<FT<control). Neither toothpaste affected the bleaching efficacy with color variables like the control (bleaching agent vs. toothpaste vs. time, P> 0.05). After coffee exposure, CBT presented lower ΔEab and ΔE₀₀ values in the HP groups (toothpaste, P< 0.0001), and lower b* and a* values in the CP groups (toothpaste vs. time, P= 0.004).</p><p><strong>Clinical significance: </strong>Fluoride or chitosan delivered by toothpaste can reduce surface alterations of the enamel during at-home bleaching, without affecting bleaching efficacy.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"78-84"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140849703","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Edoardo Ferrari-Cagidiaco, Giulia Verniani, Andrew Keeling, Ferdinando Zarone, Roberto Sorrentino, Daniele Manfredini, Marco Ferrari
{"title":"A randomized controlled clinical trial on press and block lithium disilicate partial crowns: A 4-year recall.","authors":"Edoardo Ferrari-Cagidiaco, Giulia Verniani, Andrew Keeling, Ferdinando Zarone, Roberto Sorrentino, Daniele Manfredini, Marco Ferrari","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate clinical performances of two lithium disilicate systems (Initial LiSi press vs Initial LiSi Block, GC Co.) using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 4 years of clinical service.</p><p><strong>Methods: </strong>Partial adhesive crowns on natural abutment posterior teeth were made on 60 subjects who were randomly divided into two groups: Group 1: Initial LiSi press and Group 2: Initial LiSi Block. Fabrication of partial crowns was made with full analog and digital procedure in Groups 1 and 2 respectively. The restorations were followed-up for 1 and 4 years, and the modified USPHS evaluation was performed at baseline and each recall together with periodontal evaluation. Contingency tables to assess for significant differences of success over time in each group and time-dependent Cox regression to test for differences between the two groups were used and the level of significance was set at P< 0.05.</p><p><strong>Results: </strong>Regarding modified USPHS scores, all evaluated parameters showed Alpha or Bravo and no Charlie was recorded. No statistically significant difference emerged between the two groups in any of the assessed variables (P> 0.05). No statistically significant difference between scores recorded at the baseline and each recall. All modified USPHS scores were compatible with the outcome of clinical success and no one restoration was replaced or repaired, and the survival rate was 100% after 4 years of clinical service. No difference was found between traditional and digital procedure to fabricate the crowns. The two lithium disilicate materials showed similar results after 4 years of clinical service.</p><p><strong>Clinical significance: </strong>The crowns made with the two tested lithium disilicate materials with analog and digital procedures showed 100% survival after 4 years of clinical service with no statistically significant difference using the modified USPHS scores.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"85-90"},"PeriodicalIF":0.9,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140848327","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Surface deterioration of resin composites and enamel after toothbrush simulation with new and used toothbrushes.","authors":"Mediha Büyükgöze-Dindar, Meltem Tekbaş-Atay","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effect of toothbrushing with new and used toothbrushes on the surface of resin composites and dental enamel.</p><p><strong>Methods: </strong>The extracted human incisors were selected after vestibular enamel surfaces (ES) were examined. Disc-shaped specimens of direct composite (DC) and indirect composite (IC) were fabricated. Computer-aided design-computer-aided manufacturing (CAD-CAM) composite blocks (CC) were sliced in 2 mm thickness (n= 8). The surface roughness, gloss, and color were measured. The measurements were performed before and after 3 months of toothbrushing simulation (TBS) for 2,500 circular cycles. The wear index was calculated by using the ImageJ program. The specimens were subjected to an additional 2,500 cycles and the same measurements were repeated.</p><p><strong>Results: </strong>No significant increase in surface roughness values was observed in DC, IC, and CC groups after 3 and 6 months of TBS except in the ES group. The highest change in surface gloss was observed in the DC group. Although the wear index of toothbrushes increased over time, only the increase in the IC group was statistically significant (P= 0.033).</p><p><strong>Clinical significance: </strong>Changes in surface roughness, gloss, and discoloration of the dental enamel and restorations and wear of toothbrush bristles were increased over time.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"59-65"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140846784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Lais M Berri, Evelin V M Keese, Fabiana M G França, Roberta T Basting, Waldemir F Vieira Junior, Cecilia P Turssi
{"title":"Salivary, acidic and enzymatic degradation of resin composite subjected to different finishing and polishing systems.","authors":"Lais M Berri, Evelin V M Keese, Fabiana M G França, Roberta T Basting, Waldemir F Vieira Junior, Cecilia P Turssi","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of different finishing and polishing systems on the surface roughness of a resin composite subjected to simulated saliva-, acid-, and enzyme-induced degradation.</p><p><strong>Methods: </strong>160 specimens (n= 40) were fabricated with Filtek Z350 XT nanofilled composite and analyzed for average surface roughness (Ra). The specimens were finished and polished using: AD - Al₂O₃-impreginated rubberized discs (medium, fine, and superfine grit, Sof-Lex); SD - silicon carbide and Al₂O₃-impregnated rubberized discs (coarse, medium and fine grit, Jiffy,); MB - 12- and 30-multiblade burs. The control group (CT) (n= 40) comprised specimens with a Mylar-strip-created surface. Specimens from each group were immersed in 1 mL of one of the degradation methods (n= 10): artificial saliva (ArS: pH 6.75), cariogenic challenge (CaC: pH 4.3), erosive challenge (ErC: 0.05M citric acid, pH 2.3) or enzymatic challenge (EzC: artificial saliva with 700 µg/mL of albumin, pH 6.75). The immersion period simulated a time frame of 180 days. Ra measurements were also performed at the post-polishing and post-degradation time points. The data were evaluated by three-way ANOVA for repeated measures and the Tukey tests.</p><p><strong>Results: </strong>There was significant interaction between the finishing/polishing system and the degradation method (P= 0.001). AD presented the greatest smoothness, followed by SD. After degradation, CT, AD and SD groups became significantly rougher, but not the MB group, which presented no difference in roughness before or after degradation. CT and AD groups showed greater roughness in CaC, ErC and EzC than in ArS. The SD group showed no difference in roughness when the specimens were polished with CaC, EzC or ArS, but those treated with ErC had greater roughness. In the MB group, the lower roughness values were found after using CaC and EzC, while the higher values were found using ErC or ArS.</p><p><strong>Clinical significance: </strong>As far as degradation resistance of nanofilled composite to hydrolysis, bacterial and dietary acids and enzymatic reactions is concerned, restorations that had been finished and polished with Al₂O₃-impregnated discs had the smoothest surfaces.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"66-70"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140847340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of light-, chemical-, and dual-cured universal adhesives on the internal adaptation of resin composites to pulpal and gingival internal walls.","authors":"Hoda S Ismail, Mohamed E Elawsya, Ashraf I Ali","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the internal adaptation of restorative systems bonded to mid-coronal and gingival dentin using light-cured, chemical-cured, and dual-cured adhesives, both immediately and after aging.</p><p><strong>Methods: </strong>60 molars were selected and received occluso-mesial preparations with dentin gingival margins. Restorations were performed using different restorative systems with light-cured, chemical-cured, and dual-cured adhesives. Internal adaptation was assessed by examining the percentage of continuous margin (%CM) at the pulpal and gingival dentin under a scanning electron microscope at x200 magnification. Half of the teeth were stored in sterile water for 24 hours, while the other half underwent 10,000 thermal cycles. Micro-morphological analysis was conducted on representative samples at x1,000 magnification.</p><p><strong>Results: </strong>The restorative system with light-cured adhesive exhibited significantly lower %CM values at the gingival dentin, particularly after aging. Aging had a negative impact on the %CM values of the pulpal and gingival dentin in restorative systems with light-cured and dual-cured adhesives. Regional dentin variations influenced the %CM values, especially after aging, regardless of the restorative system used. The tested restorative system with chemical-cured adhesive is preferable for achieving improved internal adaptation when bonding to both mid-coronal and gingival dentin, compared to the other tested systems.</p><p><strong>Clinical significance: </strong>The study highlights the variations in adhesive performance between different regional dentin areas using the tested restorative systems.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"91-100"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140848914","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of low power Er:YAG laser irradiation of CAD-CAM resin-based composites on resin bonding.","authors":"Yukari Odagiri, Taku Horie, Kazuho Inoue, Keiko Sakuma, Akimasa Tsujimoto, Franklin Garcia-Godoy, Morioki Fujitani","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effect of painless low-power Er:YAG laser irradiation of conventional and polymer-infiltrated ceramic network (PICN) type CAD-CAM resin-based composites (RBCs) on resin bonding.</p><p><strong>Methods: </strong>An Er:YAG laser system, phosphoric acid etchant, universal adhesive, RBC, and two types of CAD-CAM RBC block were used. Microtensile bond strength, fracture mode, scanning electron microscopy (SEM) observations of bonding interfaces and CAD-CAM surfaces, and surface roughness of ground and pretreated surfaces were investigated. As pretreatment methods, low-power Er:YAG laser irradiation and air-abrasion with alumina particles were used.</p><p><strong>Results: </strong>The effect of low-power Er:YAG laser irradiation of CAD-CAM RBCs on bonding to repair resin varied depending on the type of CAD-CAM RBCs.</p><p><strong>Clinical significance: </strong>The low-power Er:YAG laser irradiation of the conventional CAD-CAM RBCs was shown to be effective as a surface pretreatment for resin bonding, while the laser irradiation of PICN-type CAD-CAM RBCs was not effective.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"71-77"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140846788","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Laboratory study of fracture resistance and failure mode of porcelain laminate veneers with different preparation depths in endodontically treated teeth.","authors":"Amirhossein Samiee Dehpagaee, Omid Tavakol","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the fracture resistance and failure mode of porcelain laminate veneers with different preparation depths in endodontically treated teeth.</p><p><strong>Methods: </strong>Root canal treatment was performed for 40 maxillary central incisors, and then the teeth were divided into four groups (n= 10). The preparation depths were as follows: Group A: 0.9 mm, Group B: 0.6 mm, Group C: 0.3 mm, and in all three groups, 2 mm butt joint incisal reductions were performed; Group D was a control group with no preparation. Then 30 lithium disilicate porcelain veneers were milled by CAD- CAM method and cemented. After that, all specimens were subjected to cyclic loading and thermal cycling and finally were tested by a universal testing machine until failure occurred.</p><p><strong>Results: </strong>The mean failure loads (N) after exposure to continuous load were as follows: Group A: 625.70 (401.45-1037.77), Group B: 780.32 (222.93-1391.82), Group C: 748.81 (239.68-1241.87) and Group D (control) : 509.88 (84.42-1025.85) and P= 0.216. Analysis of failure mode in four groups showed that P= 0.469. There was no significant difference between the control and the other groups. In this study, 0.3, 0.6 and 0.9 mm depths of preparation for porcelain laminate veneers for endodontically treated teeth had no significant difference in fracture resistance and failure mode with non-prepared teeth.</p><p><strong>Clinical significance: </strong>Reasonable consideration might be given to porcelain laminate veneer treatment for teeth that have become discolored and resistant to bleaching (such as instances where discoloration is severe following root canal treatment). This approach is considered to be on the conservative side, and has demonstrated that a labial preparation depth reduction of up to 0.9 mm does not have any impact on the failure mode or fracture resistance of endodontically-treated teeth.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"106-112"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140848367","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Stephanie F Poole, Lívia Fiorin, Alia O A Houch, Adriana Cláudia L Faria, Ricardo F Ribeiro, Renata Cristina S Rodrigues
{"title":"Effect of toothbrushing with conventional and whitening dentifrices on monolithic zirconia after finishing procedures.","authors":"Stephanie F Poole, Lívia Fiorin, Alia O A Houch, Adriana Cláudia L Faria, Ricardo F Ribeiro, Renata Cristina S Rodrigues","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of toothbrushing with conventional and whitening dentifrices on the color difference (ΔE₀₀), gloss (Δgloss), and surface roughness (SR) of stained stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) after polishing or glazing.</p><p><strong>Methods: </strong>Specimens were divided into four groups (n=20): C (control), S (staining), SG (staining and glazing) and SP (staining and polishing). 50,000 toothbrushing cycles were performed with conventional (n=10) and whitening (n= 10) dentifrice slurries. The ΔE₀₀ and Δgloss were measured using a spectrophotometer and CIEDE2000 system while SR was measured by laser confocal microscope. The ΔE₀₀ and Δgloss data were analyzed using 2-way ANOVA, and SR data were analyzed using the linear repeated measures model, with Bonferroni's complementary test (α= 0.05).</p><p><strong>Results: </strong>The ΔE₀₀ values were beyond the acceptability threshold and no differences were found among the groups. There was no difference among groups to Δgloss after toothbrushing with conventional dentifrice while SP presented the highest values of Δgloss after toothbrushing with whitening dentifrice. Conventional dentifrice decreased the SR of stained groups and whitening dentifrice decreased SR of S and SG. The toothbrushing with conventional and whitening dentifrices promoted color difference, but did not impair gloss and surface roughness of stained 5Y-TZP.</p><p><strong>Clinical significance: </strong>Monolithic zirconia has been routinely used for esthetic restorations, however the type of finishing procedures that is carried out on it must be taken into consideration, in addition to the fact that brushing can influence the color difference of the material as well as interfere with surface roughness and gloss.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 2","pages":"101-105"},"PeriodicalIF":1.4,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140849937","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Clara I Anton Y Otero, Laurine Marger, Enrico Di Bella, Marwa Abdelaziz, Albert Feilzer, Ivo Krejci
{"title":"Activation of endodontic irrigants using a 9.3 µm CO₂ and diode lasers: A laboratory proof of concept model.","authors":"Clara I Anton Y Otero, Laurine Marger, Enrico Di Bella, Marwa Abdelaziz, Albert Feilzer, Ivo Krejci","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the differences between irrigant propagation and temperature changes using laser-activated irrigation (LAI) at different settings in an artificial root canal model.</p><p><strong>Methods: </strong>Using an artificial resin root canal model, irrigant activation was achieved in 19 experimental groups with eight samples each. A 9,300 nm CO₂ laser, two diode lasers with different settings (wavelengths 455, 808, 970, and 980 nm) were compared to 2,940 nm Er:YAG laser and traditional needle irrigation. Er:YAG and CO₂ laser were activated in the pulpal chamber only, while diode lasers and needles were inserted into the main root canal. Lasers were activated for 5x 20 seconds resulting in 100 seconds of activation or rinsing for each sample. After each activation of 20 seconds, a photo was taken of the side canals and the propagation of the dye was measured with a digital measuring tool after calibration. Further, the temperature of the irrigant was reported after activation of 20 seconds and repeated 5 times. Data were checked for normality and statistically compared.</p><p><strong>Results: </strong>All lasers increased the irrigant propagation compared to conventional irrigation. Significant differences were found between groups regarding propagation and temperature (P< 0.0027). Er:YAG and CO₂ laser had similar effects on irrigant propagation in middle and apical located side-canals with specific power parameters and were superior to diode lasers and syringe irrigation. The irrigant's temperature increased significantly with the diode and CO₂ lasers.</p><p><strong>Clinical significance: </strong>Diode lasers and CO₂ lasers have not been established for irrigant activation. 9,300 nm CO₂ lasers absorb well in water and were shown to introduce vapor bubble formation and streaming in water. Diode lasers are highly accepted in periodontics. The laser light is not absorbed in water but interacts with bacteria as well as soft tissues and contributes therefore to infection control. With a modified laser tip it was however possible to introduce cavitation and streaming in irrigants.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 1","pages":"39-46"},"PeriodicalIF":1.4,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140064674","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Putri Noerpuspita, Ivo Krejci, Tissiana Bortolotto
{"title":"Marginal adaptation of two-step self-etch versus universal adhesives for Class V restorations: Effect of Er:YAG laser vs. bur prepared cavities.","authors":"Putri Noerpuspita, Ivo Krejci, Tissiana Bortolotto","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the in vitro effect of laser and bur preparation on marginal adaptation of Class V cavities restored with a 2-step self-etch and distinct universal one-component universal adhesives used in self-etching mode.</p><p><strong>Methods: </strong>96 Class V cavities were prepared with conventional burs or with an Er:YAG laser. Four universal self-etch (Unibond Extra Low Shrinkage, All Bond Universal, SKB-100 and Prime&Bond active) and a 2-step self-etch adhesive (Clearfil SE Bond) that served as control were used to restore the cavities with direct composite. The percentages of continuous margins were evaluated by quantitative SEM analysis before and after a fatigue test consisting of 240,000 occlusal loads and 600 warm/cold thermal cycles.</p><p><strong>Results: </strong>The marginal adaptation of bur prepared restorations was statistically superior to laser-prepared ones. Class V cavities restored with Clearfil SE Bond and the one-component self-etching universal adhesives All Bond Universal and Prime&Bond active presented the highest and statistically similar percentages of continuous margins before and after loading under both bur and laser cavity preparation. The lowest percentages of continuous margins were observed in the groups restored with the low shrinking adhesive (Unibond ELS), with medians of 49 and 21 for bur and laser prepared cavities after loading.</p><p><strong>Clinical significance: </strong>Class V cavities presented smoother and higher percentages of continuous margins when prepared by bur rather than by laser. The 2-step self-etch adhesive Clearfil SE Bond and 1-step self-etch universal adhesives All Bond Universal and Prime&Bond active showed a comparable marginal performance.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 1","pages":"29-34"},"PeriodicalIF":1.4,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140064680","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}