American journal of dentistry最新文献

筛选
英文 中文
Effects of salivary contamination on the shear bond strengths of universal adhesives to dentin. 唾液污染对通用粘合剂与牙本质剪切粘接强度的影响。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-10-01
Mark A Latta, Toshiki Takamizawa, Scott M Radniecki, Wayne W Barkmeier, Frank Pfefferkorn, Luisa M Antunes, Melissa R Siebert, Alvin R Samuels
{"title":"Effects of salivary contamination on the shear bond strengths of universal adhesives to dentin.","authors":"Mark A Latta, Toshiki Takamizawa, Scott M Radniecki, Wayne W Barkmeier, Frank Pfefferkorn, Luisa M Antunes, Melissa R Siebert, Alvin R Samuels","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the shear bond strength (SBS) of resin composite to dentin contaminated with artificial saliva (AS) containing mucin and amylase using an experimental method controlling the volume of saliva and adhesive in a defined surface area.</p><p><strong>Methods: </strong>Flat bonding surfaces were prepared on extracted human molars (320 grit surface). Using adhesive tape, a 4.5 mm bonding window was prepared on the dentin surfaces. Groups (n= 12) were prepared using the etch & rinse (ER) or self-etch (SE) modes for Adhese Universal (ADH), Scotchbond Universal Plus (SBU), and Prime & Bond active (PBA) dental adhesives (DA). For the control (C) groups, the adhesives were applied per the manufacturers' instructions with 2.0 µl or 3.0 µl of the adhesive. For the saliva-contaminated groups, 1.0 µl of artificial saliva with mucin was applied in the bonding window either dried or allowed to remain wet before the application of either 2.0 µl or 3.0 µl of the adhesive. After the adhesive film was air dried and light cured using an Ultradent bonding fixture, Spectrum TPH3 was bonded to the prepared surfaces. After water storage for 24 hours at 37°C, the specimens were debonded and shear bond strength (SBS) was calculated (MPa). A Kruskal-Wallis test with Bonferroni correction was used to determine group differences (P< 0.05). Scanning electron microscopy (SEM) was performed to visualize the interfacial surfaces prepared using an ion-etching technique.</p><p><strong>Results: </strong>Mean SBS for the three adhesives were similar in both ER and SE modes to uncontaminated dentin surfaces for all the control groups. For dentin contaminated with dried or wet saliva, both the surface condition and the adhesive system were significant factors at a confidence level of 95%. For the dried saliva test groups, ADH and PBA with 3.0 µl of adhesive generated similar SBS values to controls while SBU generated lower values. Lower values were generated when using 2.0 µl of adhesive for the three adhesives in SE and ER modes except for PBA in the ER mode. Using wet saliva and 3.0 µl of adhesive ADH and SBU generated lower SBS values while PBA generated similar values to controls. Under SEM, morphology at the adhesive dentin interfaces was similar among the adhesives to uncontaminated dentin but notable differences were observed for SBU and ADH for both wet and dried saliva-contaminated surfaces.</p><p><strong>Clinical significance: </strong>Salivary contamination differentially affects shear bond strength and the morphology of the bonded interface of universal adhesives to dentin. These differences are specific to the adhesive tested and are influenced by using the etch and rinse or self-etch strategies and the volume of adhesive used. When concerned about salivary contamination clinically, maximizing the volume of adhesive on the substrate may help mitigate the deleterious effects of saliva contamination.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 5","pages":"268-276"},"PeriodicalIF":0.9,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142339251","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Microhardness, diametral tensile strength and color stability of heated resin composites used for luting ceramic veneers. 用于粘接陶瓷贴面的加热树脂复合材料的显微硬度、直径拉伸强度和颜色稳定性。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Leandro C Lima, Juliana Aldarvis, Flávia LBdo Amaral, Waldemir F Vieira-Junior, Cecilia P Turssi, Roberta T Basting, Adriano Lima, Leonardo S Barros, Fabiana Mg França
{"title":"Microhardness, diametral tensile strength and color stability of heated resin composites used for luting ceramic veneers.","authors":"Leandro C Lima, Juliana Aldarvis, Flávia LBdo Amaral, Waldemir F Vieira-Junior, Cecilia P Turssi, Roberta T Basting, Adriano Lima, Leonardo S Barros, Fabiana Mg França","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate color change in ceramic veneers luted to enamel with light-cured, dual-cured resin luting agents, or heated resin composites, as well as to evaluate microhardness and diametral tensile strength of these luting agents.</p><p><strong>Methods: </strong>For color analysis, 0.5 mm-thick leucite-reinforced glass ceramic veneers (IPS Empress CAD) were cemented onto 40 bovine dental blocks (n= 10) using RelyX Ultimate (RU) or RelyX Veneer (RV) resin-based luting agents, or Gradia Direct (GD) and Palfique Lx5 (P) heated resin composites. After luting, the specimens were subjected to thermocycling (10,000 cycles). Color analysis was performed before and after thermocycling (L*, a*, b*, ΔEab, ΔE₀₀). For the microhardness (Knoop) and diametral tensile strength tests, specimens (Ø 6 x 2 mm) were made (RU, RV, GD, and P). The specimens were subdivided into eight groups (n=10) and light-cured through different ceramic sheets (thicknesses of 0.5 mm or 1.5 mm). Knoop microhardness was performed on the top surface in a microhardness tester, and diametral tensile strength on a universal testing machine. Data were submitted to statistical analysis, using two-way ANOVA, Tukey, and Kruskal-Wallis tests (α= 0.05).</p><p><strong>Results: </strong>For the general color alteration, there was no statistically significant difference between the luting materials (ΔEab, P= 0.57; ΔE₀₀, P= 0.50). There was no interaction between luting agent and thermocycling, for L* (P= 0.87), a* (P= 0.97) and b* (P= 0.95) values. Thermocycling significantly affected only the L* values (P= 0.047), which increased after the cycles. For microhardness, there was a statistically significant difference considering luting agents and ceramic thickness (P< 0.001). GD heated resin composite presented significantly lower microhardness values than all other materials, at both ceramic thicknesses. At a thickness of 1.5 mm, RU cement had higher microhardness values than RV and P materials. Diametral tensile strength was significantly influenced by luting agent (P= 0.01), but not by ceramic thickness (P= 0.55). Diametral tensile strength of GD resin composite was higher than that of the RU, but neither of these two materials differed from RV and P.</p><p><strong>Clinical significance: </strong>Heated resin composite, used as luting agents, showed similar color stability to light-cured and dual-cure resin cements, however its microhardness was affected by ceramic thickness.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"191-196"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071772","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of provisional cementation on the stability of adhesively bonded resin-based composite crowns. 临时粘接对粘接树脂基复合牙冠稳定性的影响。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Michael B Schmidt, Angelika Rauch, Laura Haas, Martin Rosentritt
{"title":"Influence of provisional cementation on the stability of adhesively bonded resin-based composite crowns.","authors":"Michael B Schmidt, Angelika Rauch, Laura Haas, Martin Rosentritt","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the influence of temporary cementation and subsequent bonding on the durability during in-vitro aging-simulation and fracture force of resin-based composite crowns.</p><p><strong>Methods: </strong>Identical molar crowns (n=48, n=8 per group) were milled from resin-based composites and temporarily cemented and finally bonded to human molars. To simulate temporary application, crowns were cemented either with zinc-oxide-eugenol-cement (Tempbond) or with eugenol free zinc-oxide-cement (Tempbond NE). For a first simulation of a long-term provisional clinical application, thermal cycling, and mechanical loading (TCML 2 x 600 x 5°C-55°C, 2 minutes each cycle, distilled water, 240,000 cycles at 50N) was performed. After TCML all crowns were removed, cleaned, and luted either by using etch-and-rinse technique (Vococid, Futurabond U, Bifix QM) or a self-adhesive (Bifix SE) cementation system. A second thermal cycling and mechanical loading (TCML 2 x3,000 x 5°C/55°C, 2 minutes each cycle, distilled water, 1.2 x 10⁶ at 50N) was accomplished to simulate 5 years of clinical application. To assess the survival of the crowns, the failure rates during TCML were documented. As controls, crowns were included without prior provisional cementation. After TCML all crowns were loaded to failure. Failure was categorized as fracture of the crown and partial loosening of the crown.</p><p><strong>Results: </strong>All crowns survived both TCML procedures without any failures. The fracture values after TCML varied between 3,538.0 ± 1,041.2 N and 4,612.0 ± 801.5 N without significant (P= 0.146) differences between the individual groups. No correlation was found between fracture force and type of provisional cementation (zinc-oxide-eugenol vs. zinc-oxide: Pearson: -0.063/P= 0.672) or type of bonding (adhesive vs. self-adhesive: Pearson: -0.151/ P= 0.307). No different failure pattern was observed between the tested systems.</p><p><strong>Clinical significance: </strong>Regardless of the type of temporary cementation, there was no effect on the in-vitro performance or strength of the final permanently bonded crowns. Resin-based crowns might be bonded with adhesive or self-adhesive systems even after previous temporary cementation.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"183-186"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071771","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A randomized crossover trial assessing denture adhesive for prevention of food infiltration among partial denture wearers. 一项随机交叉试验,评估义齿粘合剂对局部义齿佩戴者防止食物渗入的作用。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Julie Grender, Malgorzata Klukowska, Kimberly Milleman, Jeffery Milleman
{"title":"A randomized crossover trial assessing denture adhesive for prevention of food infiltration among partial denture wearers.","authors":"Julie Grender, Malgorzata Klukowska, Kimberly Milleman, Jeffery Milleman","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>This two-treatment, four-period, double-blind, randomized controlled crossover trial assessed the ability of two denture adhesives, both applied with a thin nozzle in a continuous application pattern, to prevent food infiltration beneath partial dentures.</p><p><strong>Methods: </strong>Participants with mandibular partial dentures and a history of food particle infiltration were enrolled. All participants used both an optimized calcium/zinc partial salt of polyvinyl methyl ether/maleic acid (PVM/MA) denture adhesive and a calcium/sodium partial salt of PVM/MA test denture adhesive, twice each, throughout four study periods, according to a randomly assigned sequence. At each visit, participants underwent two assessments: once with no denture adhesive (baseline) and once with denture adhesive, 1 hour after adhesive application. For each assessment, participants ate one-half of the top of a poppy seed muffin, and a dental professional counted the seeds retained on the denture and mucosa, which was the primary variable. The change-from-baseline comparison was made for each treatment separately using a paired t-test or Wilcoxon Signed Rank test depending on the normality of the data. A between-treatment comparison for the change from baseline was performed using a crossover ANCOVA with treatment and period as fixed effects and participant as a random effect. The baseline poppy seed count was used as a covariate.</p><p><strong>Results: </strong>30 participants were enrolled; 29 completed the trial. Both denture adhesives achieved statistically significantly fewer retained seeds versus baseline (P< 0.001). The calcium/zinc adhesive reduced the seed count from baseline by 85.9% (6.18 vs 0.86), and the calcium/ sodium adhesive reduced seed count by 76.6% (6.04 vs 1.43). Comparing the two denture adhesives, the reduction in seed count from baseline was statistically significantly greater for the calcium/zinc adhesive versus the calcium/sodium formulation (P= 0.008).</p><p><strong>Clinical significance: </strong>These results support the recommendation of denture adhesive use for the prevention of food infiltration beneath partial dentures, with optimized calcium/zinc denture adhesive showing the greatest prevention benefit.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"216-220"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Staining- and aging-dependent changes in color, translucency, and gloss of cloud-shade and one-shade resin composites. 云影和单影树脂复合材料的颜色、半透明度和光泽度随染色和老化而发生的变化。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Hamid Nurrohman, Yonca Korkmaz-Ceyhan, Pinar Cevik, Rade D Paravina
{"title":"Staining- and aging-dependent changes in color, translucency, and gloss of cloud-shade and one-shade resin composites.","authors":"Hamid Nurrohman, Yonca Korkmaz-Ceyhan, Pinar Cevik, Rade D Paravina","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To compare staining and artificial accelerating aging-dependent changes in color, translucency, and gloss of cloud-shade and one-shade resin composite.</p><p><strong>Methods: </strong>The \"cloud-shade\" composites were Filtek Easy Match Universal Restorative (FU) and SimpliShade (SS): three shades each (light, medium and dark), while the \"one shade\" composites were Admira Fusion x-tra (AD) and Venus Diamond One (VE). Polymerized composite specimens (10 mm in diameter, 2 mm-thick) were polished using PoGo disks for 40 seconds. Color, translucency, and gloss measurements were performed before and after exposure to 3.8-day staining in coffee or wine (equivalent to a year of service with a 15-minute exposure per day), or exposure to 150 kJ/m² of accelerated aging (n= 5 per condition x three conditions, for a total of 15 specimens per shade). Color and translucency were measured using a benchtop spectrophotometer, and CIEDE2000 color differences (ΔE₀₀) and translucency parameter (TP₀₀) were calculated. Gloss (gloss units, GU) was measured using a small-area gloss meter. Gloss retention percentages after staining and aging were calculated. A two-way ANOVA was used to compare the effect of material and procedure, while a Tukey's post hoc multiple comparison test was used to assess differences among levels within each variable (α= 0.05).</p><p><strong>Results: </strong>The AD exhibited the best color stability upon staining, while VE was the most stable when exposed to artificial aging. Statistically significant differences were recorded among materials and procedures (P< 0.001), and their interactions (P< 0.01). AD also exhibited the highest TP stability upon staining, while the TP of FU was the most stable when exposed to artificial aging. Statistically significant differences were recorded among materials and procedures (P< 0.001), and their interactions (P< 0.01). Gloss retention upon staining and aging was greater than 90% for all tested materials. Statistically significant differences were recorded among materials (P< 0.001), procedures (P< 0.05), and their interactions (P< 0.01).</p><p><strong>Clinical significance: </strong>Staining and artificial accelerated aging changes in color, translucency parameter, and gloss retention of cloud-shade and one-shade resin composites were material- and procedure-dependent.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"201-205"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071774","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of tissue conditioner-assisted complete denture restoration: A randomized controlled clinical trial. 组织调节器辅助全口义齿修复的评估:随机对照临床试验
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Hui Gu, Xin-Chen Zhu, Na-Na Fan, Ai-Ling Cao, Qiang Xue, Li-Qin Gong
{"title":"Evaluation of tissue conditioner-assisted complete denture restoration: A randomized controlled clinical trial.","authors":"Hui Gu, Xin-Chen Zhu, Na-Na Fan, Ai-Ling Cao, Qiang Xue, Li-Qin Gong","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the clinical effect of three impression methods, conventional, closed-mouth, and tissue conditioner, on complete denture fabrication.</p><p><strong>Methods: </strong>60 subjects (edentulous with severely resorbed alveolar ridges - Atwood classification III or IV) who visited the Prosthodontic Department of Wuxi Stomatology Hospital, China, between January 2022 and June 2023, were selected for this study. The subjects were randomly divided into three groups of 20: a conventional impression group (CI group), a closed-mouth impression group (CM group), and a tissue conditioner group (TC group). Three months after denture restoration was completed, denture quality was assessed by clinicians in terms of marginal extension, retention, and stability. In addition, patients completed the oral health impact profile-edentulous (OHIP-EDENT) questionnaire to provide subjective satisfaction evaluations of the final denture restoration outcomes.</p><p><strong>Results: </strong>The comprehensive denture quality evaluation results showed that the TC group had the lowest score, which was significantly lower than that of the CM (P= 0.014) and CI (P< 0.001) groups. The average score of the CM group was also significantly lower than that of the CI group (P= 0.004), indicating that tissue conditioner restoration was the most effective method. The OHIP-EDENT scores gradually decreased across the groups from CI to CM to TC (P= 0.001), indicating patients' oral health was significantly improved using tissue conditioner.</p><p><strong>Clinical significance: </strong>Tissue conditioner is a suitable dynamic functional impression method. It can significantly improve the effects for edentulous patients and increase their satisfaction.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"177-182"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reduced staining from a chlorhexidine mouthwash: A randomized clinical trial. 洗必泰漱口水可减少染色:随机临床试验
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Saide Tang, Rabab Ahmed, Carlo A Daep, Michael A Stranick, Sarita V Mello, Betty Won, Paloma Pimenta, Yun-Po Zhang, Prem K Sreenivasan, Deborah Tischio-Bereski, Dipty Godboley, Daniel Fine
{"title":"Reduced staining from a chlorhexidine mouthwash: A randomized clinical trial.","authors":"Saide Tang, Rabab Ahmed, Carlo A Daep, Michael A Stranick, Sarita V Mello, Betty Won, Paloma Pimenta, Yun-Po Zhang, Prem K Sreenivasan, Deborah Tischio-Bereski, Dipty Godboley, Daniel Fine","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the stain preventing ability of a new chlorhexidine mouthwash while maintaining efficacy using a randomized clinical trial design.</p><p><strong>Methods: </strong>98 subjects were enrolled and completed a 4-week clinical study that evaluated the effectiveness of the new mouthwash on plaque, gingivitis, and staining as compared to a commercially available chlorhexidine mouthwash. A subset of 62 subjects was evaluated for the effectiveness of the mouthwashes against plaque bacteria.</p><p><strong>Results: </strong>After 4 weeks of use, the new chlorhexidine mouthwash reduced staining by 42.6% (P< 0.05) as compared to the commercially available mouthwash. The two mouthwashes were equivalent with regards to their effect on gingivitis, plaque, and plaque bacteria.</p><p><strong>Clinical significance: </strong>A new mouthwash, containing 0.12% chlorhexidine gluconate, has been developed that delivers stain reduction while maintaining equivalent efficacy to a commercially available chlorhexidine mouthwash with regards to gingivitis, plaque, and plaque bacteria. These findings should be considered by dental practitioners when making recommendations to patients whose teeth stain easily and need an anti-gingivitis and anti-plaque mouthwash.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"210-215"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071773","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Acute periapical abscesses and obese patients. 急性根尖周脓肿和肥胖患者。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Joseph Katz, Ilan Rotstein
{"title":"Acute periapical abscesses and obese patients.","authors":"Joseph Katz, Ilan Rotstein","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the prevalence of acute periapical abscesses (PAs) in obese patients.</p><p><strong>Methods: </strong>Integrated data of hospital patients was used. Data from the corresponding diagnosis codes for obesity and PAs was retrieved by identifying the appropriate ICD 10 codes in the database.</p><p><strong>Results: </strong>Out of 1,874,214 hospital patients studied, 147,195 patients were classified as obese, of which 3,349 had acute PAs. The difference in prevalence of PAs between obese and average-weight patients was statistically significant (OR 4.22, 95%CI: 4.05-4.39, P< 0.0001). Adjustment for diabetes comorbidity reduced the OR to 2.55; however, the difference remained statistically significant (95%CI: 2.43-2.68, P< 0.0001). Adjustment for smoking reduced the OR to 2.63; however, the difference remained statistically significant (95%CI: 2.51- 2.87, P< 0.0001). Adjustment for periodontal disease comorbidity reduced the OR to 3.85; however, the difference remained statistically significant (95%CI: 3.70-4.01, P< 0.0001). Females were more affected than males; adults were more affected than children; and African Americans were more affected than Whites.</p><p><strong>Clinical significance: </strong>Oral healthcare providers should be aware of the possible higher prevalence of periapical abscesses in obese patients as compared to average-weight individuals.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"197-200"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Antibacterial effect of Softsoap used to disinfect dentures. 用于消毒假牙的软皂的抗菌效果。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Katherine A DelPriore, Jegdish Babu, Brian R Morrow, David Umsted, Franklin Garcia-Godoy
{"title":"Antibacterial effect of Softsoap used to disinfect dentures.","authors":"Katherine A DelPriore, Jegdish Babu, Brian R Morrow, David Umsted, Franklin Garcia-Godoy","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the in vitro antibacterial effect of Softsoap and Efferdent used as solutions to disinfect Lucitone 199 poly(methyl methacrylate) (PMMA) resin used for dentures.</p><p><strong>Methods: </strong>S. mutans and plaque bacteria were grown for 24 hours, and suspended to a concentration of 1x10⁶ cells/ml. Bacterial suspensions (0.2 mL) were added to the decontaminated PMMA discs placed in a 48-well culture plate and incubated for 3 days at 37°C. The discs were rinsed to remove the unbound bacterial cells and then incubated for 60 minutes with 5% and 1% dilutions (triplicates) of each of the detergent solutions (0.3 ml). Discs were rinsed and then MTT reagent (0.2 ml) was added and incubated for 2 hours, then overnight with a solubilizing agent. An aliquot from each well (0.1 ml) was transferred to a 96-well flat bottom plate and absorbance was measured to OD @ 595 nm (MTT) of four samples for each data point. Normalized data was compared and statistically analyzed using a three-way ANOVA with Student-Newman-Keuls on Rank data with P< 0.05 for significance. Additionally, data were double-checked with the Holm-Sidak test.</p><p><strong>Results: </strong>There was no statistically significant difference between testing media for C. albicans and mixed plaque (P= 0.078) or testing duration in time at 24 hours and 21 days (P= 0.07). Statistically significant differences were found between all treatment solutions group combinations (P< 0.001) except for 30% Softsoap versus Efferdent (P= 0.056).</p><p><strong>Clinical significance: </strong>There was no statistically significant difference between testing media for C. albicans and mixed plaque (P= 0.078) or testing duration at 24 hours and 21 days (P= 0.07). Statistically significant differences were noted between all treatment solutions group combinations (P< 0.001), However, there was no difference between 30% Softsoap and Efferdent (P= 0.056).</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"206-209"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071768","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A comparison of the radiopacities of CAD-CAM restoratives: Effect of thickness. CAD-CAM 修复体的放射容积比较:厚度的影响。
IF 0.9 4区 医学
American journal of dentistry Pub Date : 2024-08-01
Dilan Kopuz, Zeynep B Arslan, Özlem Ercin, Nevin K Akar, Neslihan Tekçe
{"title":"A comparison of the radiopacities of CAD-CAM restoratives: Effect of thickness.","authors":"Dilan Kopuz, Zeynep B Arslan, Özlem Ercin, Nevin K Akar, Neslihan Tekçe","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the radiopacities of CAD-CAM materials using digital techniques.</p><p><strong>Methods: </strong>Five different CAD-CAM materials were used (Cerasmart, LAVA Ultimate, Cerec Blocs C, Tetric CAD, and IPS e.max CAD) in this study (n= 5). For each group, samples with thicknesses of 1 and 2 mm were prepared. As a control, tooth slices with 1 and 2 mm thicknesses and a 99.5% pure aluminum step wedge were used. The samples, tooth slices, and step wedges were placed on a photostimulable phosphor plate. Radiographs were taken at 30 cm distance with 7 mA, 70 kVp, and 0.32 ms exposure time. The images were analyzed using the ImageJ software to measure the mean gray values. Data were analyzed with Kruskal-Wallis H test and the Mann-Whitney U test (P< 0.05).</p><p><strong>Results: </strong>In the comparison of CAD-CAM materials with 1 and 2-mm thicknesses, the highest radiopacity value was seen in LAVA Ultimate samples (2.67 ± 0.05 for 1 mm samples: 5.74 ± 0.13 for 2 mm samples). The lowest value in 1 mm samples was seen in IPS e.max (0.59 ± 0.07), and in 2 mm samples, in Cerec Blocs C samples (1.49 ± 0.11). The results showed that the radiopacity values of the samples were associated with increased thicknesses. The 2 mm samples' radiopacity values were statistically significantly higher compared with the 1 mm samples. All samples except IPS e.max CAD and Cerec Blocs C had higher radiopacity than dentin (P< 0.05).</p><p><strong>Clinical significance: </strong>The radiopacity values were affected by thickness and type of materials. Comprehensive knowledge about the radiopacity of materials enables the selection of appropriate materials to achieve clinical success, which serves as a useful diagnostic aid in determining the long-term durability of restorations.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"37 4","pages":"187-190"},"PeriodicalIF":0.9,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142071765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信