Transactions of Society for Mining, Metallurgy, and Exploration, Inc最新文献

筛选
英文 中文
Tube bundle system studies at Signal Peak Energy Bull Mountains #1 Mine. 信号峰能源牛山1号矿管束系统研究。
R K Zipf, R Ochsner, R Krog, W Marchewka, M Valente, R Jensen
{"title":"Tube bundle system studies at Signal Peak Energy Bull Mountains #1 Mine.","authors":"R K Zipf,&nbsp;R Ochsner,&nbsp;R Krog,&nbsp;W Marchewka,&nbsp;M Valente,&nbsp;R Jensen","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A tube bundle system (TBS) is a mechanical system for continuously drawing gas samples through tubes from multiple monitoring points located in an underground coal mine for analysis and display on the surface. The U.S. National Institute for Occupational Safety and Health (NIOSH), in collaboration with Signal Peak Energy (SPE), LLC, Bull Mountains No. 1 Mine, operated a TBS during mining of two bleederless, longwall panels. This paper describes the gas analysis data and its interpretation. As verified by the TBS, coal at the SPE mine tends to oxidize slowly. It was known that a reservoir of low-oxygen concentration atmosphere developed about 610 m (2,000 ft) behind the longwall face. A bleederless ventilation system facilitates formation of an inert atmosphere in this longwall gob and decreases the likelihood of spontaneous combustion. Connections of the mine atmosphere to the surface through subsidence cracks could allow airflow into the longwall gob, revive coal oxidation and increase spontaneous combustion risk. The atmospheric composition of the sealed areas was homogeneous, except in the immediate vicinity of suspected ingassing points. The TBS verified that gases within the partially sealed, bleederless longwall gob expanded into the longwall tailgate area when barometric pressure decreased. The concentration of carbon dioxide in the back return airflow at the longwall tailgate was observed to increase by a factor of three and possibly up to 10 times the typical background concentration of 0.5 to 1.0%, depending on the size of the longwall gob and the magnitude of barometric pressure decrease. TBS have the inherent disadvantage of slow response time due to travel time of the gas samples and sequential gas analyses. A TBS or similar continuous monitoring system could be beneficial in detecting and providing warning of potentially hazardous gas concentrations, if the slow response time of the system is always understood.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"334 ","pages":"489-497"},"PeriodicalIF":0.0,"publicationDate":"2014-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4545480/pdf/nihms707355.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34017236","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES. 矿井常见可燃物火灾的烟雾和气体传感器响应评价。
Inoka Eranda Perera, Charles D Litton
{"title":"EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES.","authors":"Inoka Eranda Perera,&nbsp;Charles D Litton","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m<sup>-1</sup> optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters' Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"336 1","pages":"381-390"},"PeriodicalIF":0.0,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4517983/pdf/nihms703016.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33951001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Examination of redirected continuous miner scrubber discharge configurations for exhaust face ventilation systems. 排气面通风系统用重定向连续矿用洗涤器排放装置的检验。
J A Organiscak, T W Beck
{"title":"Examination of redirected continuous miner scrubber discharge configurations for exhaust face ventilation systems.","authors":"J A Organiscak,&nbsp;T W Beck","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently studied several redirected scrubber discharge configurations in its full-scale continuous miner gallery for both dust and gas control when using an exhaust face ventilation system. Dust and gas measurements around the continuous mining machine in the laboratory showed that the conventional scrubber discharge directed outby the face with a 12.2-m (40-ft) exhaust curtain setback appeared to be one of the better configurations for controlling dust and gas. Redirecting all the air toward the face equally up both sides of the machine increased the dust and gas concentrations around the machine. When all of the air was redirected toward the face on the off-curtain side of the machine, gas accumulations tended to be reduced at the face, at the expense of increased dust levels in the return and on the curtain side of the mining machine. A 6.1-m (20-ft) exhaust curtain setback without the scrubber operating resulted in the lowest dust levels around the continuous mining machine, but this configuration resulted in some of the highest levels of dust in the return and gas on the off-curtain side of the mining face. Two field studies showed some similarities to the laboratory findings, with elevated dust levels at the rear corners of the continuous miner when all of the scrubber exhaust was redirected toward the face either up the off-tubing side or equally up both sides of the mining machine.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"334 1","pages":"435-443"},"PeriodicalIF":0.0,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4523470/pdf/nihms707361.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33903483","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrical injuries in the US mining industry, 2000-2009. 2000-2009年美国采矿业的电气伤害。
G T Homce, J C Cawley
{"title":"Electrical injuries in the US mining industry, 2000-2009.","authors":"G T Homce,&nbsp;J C Cawley","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) conducted a study of mining industry electrical injuries reported to the U.S. Mine Safety and Health Administration (MSHA) for the years 2000 to 2009. The findings of that study are detailed in this paper, and serve to characterize the circumstances surrounding electrical injuries and identify causal factors. The study included three tasks: 1) a direct review of mining industry occupational injury data compiled by MSHA, 2) interpretation of the narrative descriptions available for the injuries (from MSHA data) and 3) a separate examination of fatal electrical injuries. Eight-hundred sixty-five electrical injuries were reported during the 10-year period studied, with 39 of those being fatalities. This makes electrical injuries disproportionately fatal with respect to most other types of injuries in mining. Electrical injury rates were higher in coal mining than noncoal mining and, within the coal sector, rates were higher in underground operations than in surface operations. Of the 865 total cases, electrical and machine maintenance or repair activities were involved in 580 (69%), and electricians and mechanics were injured in 362 cases (42%). Of the 39 fatal electrical injuries, 27 (69%) involved electrical maintenance or repair work, and in 21 of these 27 cases, the failure to de-energize, lock-out and tag the circuit was the cause or a contributing factor. Also, contractor employees had a much greater chance of an electrical injury being fatal than did mine operator employees. The top three root causes for fatal electrical injuries were 1) no or inadequate lock-out and tagging, 2) failure of power system components and 3) contact of overhead electrical power lines by mobile equipment.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"34 ","pages":"367-375"},"PeriodicalIF":0.0,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4558412/pdf/nihms-707258.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33981863","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of cap lamp and laser illumination for detecting visual escape cues in smoke. 帽灯和激光照明在烟雾中探测视觉逃逸线索的比较。
T J Lutz, J J Sammarco, J R Srednicki, S Gallagher
{"title":"Comparison of cap lamp and laser illumination for detecting visual escape cues in smoke.","authors":"T J Lutz,&nbsp;J J Sammarco,&nbsp;J R Srednicki,&nbsp;S Gallagher","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The Illuminating Engineering Society of North America reports that an underground mine is the most difficult environment to illuminate (Rea, 2000). Researchers at the U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) are conducting ongoing studies designed to explore different lighting technologies for improving mine safety. Underground miners use different visual cues to escape from a smoke-filled environment. Primary and secondary escapeways are marked with reflective ceiling tags of various colors. Miners also look for mine rail tracks. The main objective of this paper is to compare different lighting types and ceiling tag colors to differentiate what works best in a smoke-filled environment. Various cap lamps (LED and incandescent) and lasers (red, blue, green) were compared to see which options resulted in the longest detection distances for red, green and blue reflective markers and a section of mine rail track. All targets advanced toward the human subject inside of a smoke-filled room to simulate the subject walking in a mine environment. Detection distances were recorded and analyzed to find the best cap lamp, laser color and target color in a smoke environment. Results show that cap lamp, laser color and target color do make a difference in detection distances and are perceived differently based on subject age. Cap lamps were superior to lasers in all circumstances of ceiling tag detection, with the exception of the green laser. The incandescent cap lamp worked best in the simulated smoke compared to the LED cap lamps. The green laser was the best color for detecting the tags and track compared to the red and blue lasers. The green tags were the easiest color to detect on the ceiling. On average, the track was easier for the subjects to detect than the ceiling tags.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"334 1","pages":"401-409"},"PeriodicalIF":0.0,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521996/pdf/nihms704498.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33889261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Examination of water spray airborne coal dust capture with three wetting agents. 三种润湿剂对水雾空气中煤尘捕集的试验。
J A Organiscak
{"title":"Examination of water spray airborne coal dust capture with three wetting agents.","authors":"J A Organiscak","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Water spray applications are one of the principal means of controlling airborne respirable dust in coal mines. Since many coals are hydrophobic and not easily wetted by water, wetting agents can be added to the spray water in an effort to improve coal wetting and assist with dust capture. In order to study wetting agent effects on coal dust capture, laboratory experiments were conducted with three wetting agents used by the coal industry on -325 mesh sized Pocahontas No. 3 coal dust. Significant differences in coal dust sink times were observed among the three wetting agents at water mixture concentrations of 0.05%, 0.1% and 0.2%. The best wetting agent as identified by the coal dust sink test was only tested at the lowest 0.05% water mixture concentration and was found to have a negligible effect on spray airborne dust capture. Water spray airborne dust capture results for all three wetting agents tested at a 0.2% water mixture concentration showed that all three wetting agents exhibit similar but small improvements in dust capture efficiency as compared with water. These results indicate that the coal dust sink test may not be a good predictor for the capture of airborne dust. Additional research is needed to examine if the coal dust sink test is a better predictor of wetting agent dust suppression effects during cutting, loading, conveying and dumping of coal products by comparison to airborne dust capture from sprays.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"334 1","pages":"427-434"},"PeriodicalIF":0.0,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4523468/pdf/nihms707324.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33903482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Computational fluid dynamics (CFD) investigation of impacts of an obstruction on airflow in underground mines. 计算流体力学(CFD)研究了地下矿井中障碍物对气流的影响。
L Zhou, G Goodman, A Martikainen
{"title":"Computational fluid dynamics (CFD) investigation of impacts of an obstruction on airflow in underground mines.","authors":"L Zhou,&nbsp;G Goodman,&nbsp;A Martikainen","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Continuous airflow monitoring can improve the safety of the underground work force by ensuring the uninterrupted and controlled distribution of mine ventilation to all working areas. Air velocity measurements vary significantly and can change rapidly depending on the exact measurement location and, in particular, due to the presence of obstructions in the air stream. Air velocity must be measured at locations away from obstructions to avoid the vortices and eddies that can produce inaccurate readings. Further, an uninterrupted measurement path cannot always be guaranteed when using continuous airflow monitors due to the presence of nearby equipment, personnel, roof falls and rib rolls. Effective use of these devices requires selection of a minimum distance from an obstacle, such that an air velocity measurement can be made but not affected by the presence of that obstacle. This paper investigates the impacts of an obstruction on the behavior of downstream airflow using a numerical CFD model calibrated with experimental test results from underground testing. Factors including entry size, obstruction size and the inlet or incident velocity are examined for their effects on the distributions of airflow around an obstruction. A relationship is developed between the minimum measurement distance and the hydraulic diameters of the entry and the obstruction. A final analysis considers the impacts of continuous monitor location on the accuracy of velocity measurements and on the application of minimum measurement distance guidelines.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"332 ","pages":"505-513"},"PeriodicalIF":0.0,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4575277/pdf/nihms-707335.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34189933","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Case study of controlled recirculation at a Wyoming trona mine. 怀俄明煤矿控制再循环的案例研究。
C Pritchard, D Scott, G Frey
{"title":"Case study of controlled recirculation at a Wyoming trona mine.","authors":"C Pritchard,&nbsp;D Scott,&nbsp;G Frey","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Controlled recirculation has been used in the metal/nonmetal mining industry for energy savings when heating and cooling air, in undersea mining and for increasing airflow to mining areas. For safe and effective use of controlled district recirculation, adequate airflow to dilute contaminants must exist prior to implementation, ventilation circuit parameters must be accurately quantified, ventilation network modeling must be up to date, emergency planning scenarios must be performed and effective monitoring and control systems must be installed and used. Safety and health issues that must be considered and may be improved through the use of controlled district recirculation include blasting fumes, dust, diesel emissions, radon and contaminants from mine fires. Controlled recirculation methods are expected to become more widely used as mines reach greater working depths, requiring that these health and safety issues be well understood. The U.S. National Institute for Occupational Safety and Health (NIOSH) conducted two controlled recirculation tests over three days at a Wyoming trona mine, utilizing an inline booster fan to improve airflow to a remote and difficult-to-ventilate development section. Test results were used to determine the effect that recirculation had on air qualities and quantities measured in that section and in other adjacent areas. Pre-test conditions, including ventilation quantities and pressures, were modeled using VnetPC. During each test, ventilation quantities and pressures were measured, as well as levels of total dust. Sulfur hexafluoride (SF <sub><i>6</i></sub> ) tracer gas was used to simulate a mine contaminant to monitor recirculation wave cycles. Results showed good correlation between the model results and measured values for airflows, pressure differentials, tracer gas arrival times, mine gasses and dust levels.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"334 1","pages":"444-448"},"PeriodicalIF":0.0,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4524347/pdf/nihms707342.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33903485","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信