排气面通风系统用重定向连续矿用洗涤器排放装置的检验。

J A Organiscak, T W Beck
{"title":"排气面通风系统用重定向连续矿用洗涤器排放装置的检验。","authors":"J A Organiscak,&nbsp;T W Beck","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently studied several redirected scrubber discharge configurations in its full-scale continuous miner gallery for both dust and gas control when using an exhaust face ventilation system. Dust and gas measurements around the continuous mining machine in the laboratory showed that the conventional scrubber discharge directed outby the face with a 12.2-m (40-ft) exhaust curtain setback appeared to be one of the better configurations for controlling dust and gas. Redirecting all the air toward the face equally up both sides of the machine increased the dust and gas concentrations around the machine. When all of the air was redirected toward the face on the off-curtain side of the machine, gas accumulations tended to be reduced at the face, at the expense of increased dust levels in the return and on the curtain side of the mining machine. A 6.1-m (20-ft) exhaust curtain setback without the scrubber operating resulted in the lowest dust levels around the continuous mining machine, but this configuration resulted in some of the highest levels of dust in the return and gas on the off-curtain side of the mining face. Two field studies showed some similarities to the laboratory findings, with elevated dust levels at the rear corners of the continuous miner when all of the scrubber exhaust was redirected toward the face either up the off-tubing side or equally up both sides of the mining machine.</p>","PeriodicalId":75236,"journal":{"name":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","volume":"334 1","pages":"435-443"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4523470/pdf/nihms707361.pdf","citationCount":"0","resultStr":"{\"title\":\"Examination of redirected continuous miner scrubber discharge configurations for exhaust face ventilation systems.\",\"authors\":\"J A Organiscak,&nbsp;T W Beck\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently studied several redirected scrubber discharge configurations in its full-scale continuous miner gallery for both dust and gas control when using an exhaust face ventilation system. Dust and gas measurements around the continuous mining machine in the laboratory showed that the conventional scrubber discharge directed outby the face with a 12.2-m (40-ft) exhaust curtain setback appeared to be one of the better configurations for controlling dust and gas. Redirecting all the air toward the face equally up both sides of the machine increased the dust and gas concentrations around the machine. When all of the air was redirected toward the face on the off-curtain side of the machine, gas accumulations tended to be reduced at the face, at the expense of increased dust levels in the return and on the curtain side of the mining machine. A 6.1-m (20-ft) exhaust curtain setback without the scrubber operating resulted in the lowest dust levels around the continuous mining machine, but this configuration resulted in some of the highest levels of dust in the return and gas on the off-curtain side of the mining face. Two field studies showed some similarities to the laboratory findings, with elevated dust levels at the rear corners of the continuous miner when all of the scrubber exhaust was redirected toward the face either up the off-tubing side or equally up both sides of the mining machine.</p>\",\"PeriodicalId\":75236,\"journal\":{\"name\":\"Transactions of Society for Mining, Metallurgy, and Exploration, Inc\",\"volume\":\"334 1\",\"pages\":\"435-443\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4523470/pdf/nihms707361.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of Society for Mining, Metallurgy, and Exploration, Inc\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of Society for Mining, Metallurgy, and Exploration, Inc","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

美国国家职业安全与健康研究所(NIOSH)矿山安全与健康研究办公室(OMSHR)最近在其全尺寸连续采矿巷道中研究了几种重定向洗涤器排放配置,用于使用排气面通风系统时的粉尘和气体控制。在实验室中对连续采矿机周围的粉尘和气体进行了测量,结果表明,传统的洗涤器从工作面向外排出12.2米(40英尺)的排烟幕似乎是控制粉尘和气体的较好配置之一。将所有的空气重新定向到机器两侧均匀向上的表面,增加了机器周围的灰尘和气体浓度。当所有的空气都被重新引导到机器的非窗帘一侧的工作面时,工作面的气体积累往往会减少,代价是采矿机器的返回和窗帘一侧的粉尘水平增加。在没有洗涤器运行的情况下,6.1米(20英尺)的排气幕后退导致连续采矿机周围的粉尘含量最低,但这种配置导致采矿工作面的非幕侧回风和气体中的粉尘含量最高。两项现场研究显示了与实验室发现的一些相似之处,当所有洗涤器废气被重新定向到采矿机的表面时,连续采矿机后角的粉尘水平升高,要么在离油管一侧,要么在采矿机的两侧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Examination of redirected continuous miner scrubber discharge configurations for exhaust face ventilation systems.

The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently studied several redirected scrubber discharge configurations in its full-scale continuous miner gallery for both dust and gas control when using an exhaust face ventilation system. Dust and gas measurements around the continuous mining machine in the laboratory showed that the conventional scrubber discharge directed outby the face with a 12.2-m (40-ft) exhaust curtain setback appeared to be one of the better configurations for controlling dust and gas. Redirecting all the air toward the face equally up both sides of the machine increased the dust and gas concentrations around the machine. When all of the air was redirected toward the face on the off-curtain side of the machine, gas accumulations tended to be reduced at the face, at the expense of increased dust levels in the return and on the curtain side of the mining machine. A 6.1-m (20-ft) exhaust curtain setback without the scrubber operating resulted in the lowest dust levels around the continuous mining machine, but this configuration resulted in some of the highest levels of dust in the return and gas on the off-curtain side of the mining face. Two field studies showed some similarities to the laboratory findings, with elevated dust levels at the rear corners of the continuous miner when all of the scrubber exhaust was redirected toward the face either up the off-tubing side or equally up both sides of the mining machine.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信