2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)最新文献

筛选
英文 中文
Automatic Segmentation of Pulmonary Lobes in Pulmonary CT Images using Atlas-based Unsupervised Learning Network 基于atlas的无监督学习网络的肺CT图像肺叶自动分割
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507753
Ruxue Hu, Hongkai Wang, T. Ristaniemi, Wentao Zhu, Ling Chen, Hui Shen, Fan Rao
{"title":"Automatic Segmentation of Pulmonary Lobes in Pulmonary CT Images using Atlas-based Unsupervised Learning Network","authors":"Ruxue Hu, Hongkai Wang, T. Ristaniemi, Wentao Zhu, Ling Chen, Hui Shen, Fan Rao","doi":"10.1109/NSS/MIC42677.2020.9507753","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507753","url":null,"abstract":"Pulmonary lobes segmentation of pulmonary CT images is important for assistant therapy and diagnosis of pulmonary disease in many clinical tasks. Recently supervised deep learning methods are applied widely in fast automatic medical image segmentation including pulmonary lobes segmentation of pulmonary CT images. However, they require plenty of ground truth due to their supervised learning scheme, which are always difficult to realize in practice. To address this issue, in this study we extend an existed unsupervised learning network with an extra pulmonary mask constraint to develop a deformable pulmonary lobes atlas and apply it for fast automatic segmentation of pulmonary lobes in pulmonary CT images. The experiment on 40 pulmonary CT images shows that our method can segment the pulmonary lobes in seconds, and achieve average Dice of 0.906 ± 0.044 and average surface distance of 0.495 ± 0.380 mm, which outperforms the state-of-the-art methods in segmentation accuracy. Our method successfully combines the advantages of both deformable atlas and unsupervised learning for automatic segmentation and ensures the consistent and topology preserving of pulmonary lobes without any postprocessing.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"32 1","pages":"1-2"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81922233","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The ORION Chipset for the X-Gamma Imaging Spectrometer Onboard of the THESEUS Space Mission 用于忒修斯太空任务上的x -伽马成像光谱仪的ORION芯片组
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9508085
F. Mele, M. Gandola, M. Grassi, C. Labanti, P. Malcovati, G. Bertuccio
{"title":"The ORION Chipset for the X-Gamma Imaging Spectrometer Onboard of the THESEUS Space Mission","authors":"F. Mele, M. Gandola, M. Grassi, C. Labanti, P. Malcovati, G. Bertuccio","doi":"10.1109/NSS/MIC42677.2020.9508085","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9508085","url":null,"abstract":"We present the design of a multichip Application Specific Integrated Circuit (ASIC), named ORION, for the front-end readout of the X-Gamma Imaging Spectrometer (XGIS) on-board the Transient High Energy Sky and Early Universe Surveyor (THESEUS) space mission. The XGIS instrument is composed by two cameras that operate as a wide field deep sky monitors with a broad energy range from 2 keV to 20 MeV, and it is based on a position sensitive double-detection mechanism for image reconstruction, in which a single pixel is constituted by a Thallium activated Cesium Iodide (CsI(Tl)) scintillator crystals and two Silicon Drift Detectors (SDDs) glued at both crystal ends, whose signal is collected, reconstructed and digitized by the presented ORION chipset. In each camera, the ORION chipset is organized in a constellation of 12 800 analog front-end chips (ORION-FE), closely connected to the SDD anodes, and 800 mixed signal multi-channel back-end chips (ORION-BE) for signal processing and digitalization, for a total 25 600 ORION-FE and 1600 ORION-BE in the complete instrument. The back-end chips have two parallelized X and Gamma signal processors, for low-energy and high-energy photons respectively, which allow a tailored optimization on the noise and energy range requirements for each type of event. The chipset has an input dynamic range of 32 fC that allows to process signals with a linearity error below ±1.2% on the Gamma processor, and below ±0.1% on the X processor. The nominal Equivalent Noise Charge (ENC) of the system at -20 °C for an estimated detector leakage current of 0.7 pA is 12.5 el. r.m.s at 1 µs peaking time for the X processor, and 32.9 el. r.m.s. at 3 µs peaking time for the Gamma processor. The simulated power consumption is of 1.55 mW per pixel.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"3 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84249005","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
On-the-Fly Self-Reconfiguring FPGAs for Single Event Upset Monitoring at Belle II Belle II单事件干扰监测的动态自重构fpga
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507982
R. Giordano, A. Aloisio, S. Massarotti, G. Tortone, Y. Lai, S. Korpar, R. Pestotnik, L. Šantelj, A. Lozar, M. Shoji, S. Nishida
{"title":"On-the-Fly Self-Reconfiguring FPGAs for Single Event Upset Monitoring at Belle II","authors":"R. Giordano, A. Aloisio, S. Massarotti, G. Tortone, Y. Lai, S. Korpar, R. Pestotnik, L. Šantelj, A. Lozar, M. Shoji, S. Nishida","doi":"10.1109/NSS/MIC42677.2020.9507982","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507982","url":null,"abstract":"High Energy Physics experiments usually require radiation-tolerant electronics for on-detector operation. When possible, it is preferable to use commercial off-the-shelf components. For purely digital functions, such as data aggregation, processing and transfer, static RAM-based Field Programmable Gate Arrays (SRAM-based FPGAs) are increasingly being used on outer sub-detectors. While these devices offer great advantages in terms of flexibility and performance, they pose important issues related to single-event upsets (SEUs) in their configuration. These upsets need to be corrected, i.e. scrubbed, and their rate is valuable information for choosing the proper mitigation strategy. If possible, dedicated in situ measurements should be performed to this aim. In this work, we present a system for SEU monitoring in FPGAs, which we installed in proximity of the Belle II detector at the SuperKEKB electron-positron collider of the KEK laboratory (Tsukuba, JP). As part of the system, we also describe our design of a robust-yet-flexible configuration scrubber, portable over Xilinx Virtex-5 and 7- Series FPGA families. We discuss the measured FPGA configuration error rate and the device power consumption. We compare our results across the tested FPGA families. We compare our scrubber to the Xilinx Soft Error Mitigation controller in terms of reliability by means of proton beam tests conducted at INFN Laboratori Nazionali del Sud (Catania, Italy). In order to show the flexibility of our scrubber, we briefly describe its usage in the Belle II aerogel ring imaging Cherenkov counter.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"42 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84265056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A New Code Change Prediction Dataset: A Case Study Based on HEP Software 一种新的代码变更预测数据集:基于HEP软件的案例研究
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9508053
E. Ronchieri, M. Canaparo, Yue Yang, A. Costantini, D. C. Duma, D. Salomoni
{"title":"A New Code Change Prediction Dataset: A Case Study Based on HEP Software","authors":"E. Ronchieri, M. Canaparo, Yue Yang, A. Costantini, D. C. Duma, D. Salomoni","doi":"10.1109/NSS/MIC42677.2020.9508053","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9508053","url":null,"abstract":"Predicting changes proneness in software modules is an open area of research. This activity implies dealing with code changes datasets that are typically either incomplete or absent. To obtain a change dataset properly constructed, a new dictionary of software changes terms has been defined by leveraging our experience with the High Energy Physics (HEP) software. Our new dictionary includes various terms that classify a “code change” like warning, fixed bug, minor fix and optimization. Each term has been opportunely used to label each software module analyzed. The derived categories range from code development to performance improvements and refer to single pieces of the considered software. The resulting code-change dataset has been used to build a prediction model able to monitor software evolution and assess its maintainability over time. The present article gives details of the designed procedure that has been followed and presents the obtained results. The designed dictionary can be used with other, non-HEP, software as long as researchers can rely on well documented code changes. In such respect, our prediction model can be tested against these new datasets in order to improve both reliability and performance.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"220 1","pages":"1-2"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76972239","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Characterizing Primary Breast Cancer and Nodal Involvement with High-Resolution PET/MRI: Novel PET Configurations and Preliminary Results 用高分辨率PET/MRI表征原发性乳腺癌和淋巴结累及:新的PET配置和初步结果
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507857
Shouyi Wei, Lemise Saleh, Michael Salerno, Jules A. Cohen, A. Stopeck, L. Baer, Paul Fisher, D. Franceschi, Patricia Thompson, P. Vaska
{"title":"Characterizing Primary Breast Cancer and Nodal Involvement with High-Resolution PET/MRI: Novel PET Configurations and Preliminary Results","authors":"Shouyi Wei, Lemise Saleh, Michael Salerno, Jules A. Cohen, A. Stopeck, L. Baer, Paul Fisher, D. Franceschi, Patricia Thompson, P. Vaska","doi":"10.1109/NSS/MIC42677.2020.9507857","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507857","url":null,"abstract":"High-resolution PET imaging has considerable potential to improve management of breast cancer, especially if it could be acquired simultaneously with the clinical standard of breast MRI. In this multimodal approach, PET contributes critical information on specific molecular subtypes and heterogeneity, while avoiding the challenge of reproducibly positioning the breast which confronts technologists when PET and MRI images are acquired separately. Using a compact, high-resolution and MR-compatible PET system (VersaPET) mounted into a breast MRI table, we have begun to assess the feasibility of this approach by collecting preliminary FDG data on primary tumors in breast cancer patients. In order to augment this approach to examine nodal involvement, we also performed a simulation study that incorporates novel detector geometries to expand the FOV to include axillary lymph nodes which are critical for diagnosing metastasis. We evaluated scanner geometries with limited angle sampling and features including time of flight (TOF) and depth of interaction (DOI) readouts, using GATE simulation and detection-based tasks using channelized Hotelling observer (CHO). Our simulation result indicates superior performance for detection of low-grade (3:1 lesion to tissue contrast), small (3 mm diameter) lesions using the proposed scanners compared to whole-body PET. We show that the incorporation of a DOI resolution of 2 mm substantially improves the detection tasks for the proposed scanner designs, while TOF capability is less impactful.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"9 1","pages":"1-4"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77094667","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluating 3D Gamma-ray Imaging Techniques for Distributed Sources at the Fukushima Daiichi Nuclear Power Station 评估福岛第一核电站分布式源的三维伽马射线成像技术
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507840
K. Knecht, D. Hellfeld, R. Pavlovsky, B. Quiter, T. Joshi, T. Torii, Y. Furuta, K. Vetter
{"title":"Evaluating 3D Gamma-ray Imaging Techniques for Distributed Sources at the Fukushima Daiichi Nuclear Power Station","authors":"K. Knecht, D. Hellfeld, R. Pavlovsky, B. Quiter, T. Joshi, T. Torii, Y. Furuta, K. Vetter","doi":"10.1109/NSS/MIC42677.2020.9507840","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507840","url":null,"abstract":"Portable radiation detection systems can be equipped with contextual sensors to allow free-moving 3D gamma-ray source mapping and imaging through a method called scene data fusion (SDF). The scene information provided by the contextual sensors can be used to enable 3D mapping and constrain gamma-ray image reconstruction to improve accuracy and computational efficiency. SDF can be a useful tool in a wide range of radiological and nuclear safety and security applications such as radiation mapping for contamination remediation. To demonstrate SDF for this application, Polaris-Lamp,a commercially available detector that has been integrated with contextual sensors, was hand-carried in a parking lot containing vehicles used during remediation efforts following the March 2011 Fukushima Daiichi Nuclear Power Station accident. In order to detect and map potential contamination of the vehicles, proximity mapping and Compton imaging techniques have been applied to data collected over a series of short measurements, each covering different areas of the parking lot. Proximity mapping successfully identified which vehicles are contaminated, but Compton imaging further improved localization of intensity to key vehicle features on top of distributed contamination, demonstrating the utility of SDF in radiation mapping of unknown distributed source environments. Methods to stitch multiple reconstructions together were also developed, allowing the creation of large area radiation maps that are globally consistent. The work presented here illustrates the utility of SDF with an contextual-sensor enhanced commercial radiation detection and imaging system deployed in a hand-portable format to effectively map extended areas and localize radiological contamination within minutes which is impossible to achieve with conventional means with hand-portable radiation detectors or statically deployed gamma-ray imagers.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"29 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77916716","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Comparison of Conventional and SDM-Based Read-Out Systems for Gamma-Ray Imaging 传统和基于sdm的伽马射线成像读出系统的比较
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507744
Maria Ruiz-Gonzalez, L. Furenlid
{"title":"Comparison of Conventional and SDM-Based Read-Out Systems for Gamma-Ray Imaging","authors":"Maria Ruiz-Gonzalez, L. Furenlid","doi":"10.1109/NSS/MIC42677.2020.9507744","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507744","url":null,"abstract":"One relatively inexpensive way a gamma-ray imaging system can be upgraded is by updating the read-out electronics system and, as a consequence, modernizing the digitization and data-processing methods. The objective of this project is to replace the front-end electronics of modular gamma-ray cameras utilized in multiple small-animal PET and SPECT systems developed at the University of Arizona within the last 20 years. We have previously presented the new front-end board, which utilizes 1-bit sigma-delta modulation (SDM) for energy estimation and a non-uniform 2-bit SDM architecture for timing estimation and triggering. One advantage of this digitization method is that instead of ADC integrated circuits, only a few analog components per channel are utilized, which reduces the complexity and power consumption of the system. The board also includes, among other resources, a Xilinx FPGA combined with an ARM-based processor, DDR3 SDRAM and QSPI flash memory. This project presents the comparison between the original and the new SDM-based front-end electronics board, implemented in a 9-channel modular gamma-ray camera, by obtaining the spectrum of each individual photomultiplier tube (PMT) with both frontend boards. The results show an improvement of 1.5x to 2x in the PMT spectrum resolution with the new approach.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"14 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72880518","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Results from In Situ Monitoring of Radiation Damage of Scintillation Fibers 闪烁光纤辐射损伤的原位监测结果
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507783
J. Wetzel, E. Tiras, O. Koseyan, N. Bostan, B. Bilki, D. Winn, Y. Onel
{"title":"Results from In Situ Monitoring of Radiation Damage of Scintillation Fibers","authors":"J. Wetzel, E. Tiras, O. Koseyan, N. Bostan, B. Bilki, D. Winn, Y. Onel","doi":"10.1109/NSS/MIC42677.2020.9507783","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507783","url":null,"abstract":"We report preliminary results from in situ monitoring of an optical scintillating fiber while being exposed to a cesium-173 gamma radiatior. We measured the degradation of fiber transmittance across the visible spectrum as a function of time. We observed that the region below 500 nm was degraded quickly and thoroughly while wavelengths above 500 nm lost clarity more slowly.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"185 1","pages":"1-2"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73377503","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Deep Learning-based Automated Delineation of Head and Neck Malignant Lesions from PET Images 基于深度学习的PET图像头颈部恶性病变自动圈定
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9507977
H. Arabi, Isaac Shiri, E. Jenabi, M. Becker, H. Zaidi
{"title":"Deep Learning-based Automated Delineation of Head and Neck Malignant Lesions from PET Images","authors":"H. Arabi, Isaac Shiri, E. Jenabi, M. Becker, H. Zaidi","doi":"10.1109/NSS/MIC42677.2020.9507977","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9507977","url":null,"abstract":"Accurate delineation of the gross tumor volume (GTV) is critical for treatment planning in radiation oncology. This task is very challenging owing to the irregular and diverse shapes of malignant lesions. Manual delineation of the GTVs on PET images is not only time-consuming but also suffers from inter- and intra-observer variability. In this work, we developed deep learning-based approaches for automated GTV delineation on PET images of head and neck cancer patients. To this end, V-Net, a fully convolutional neural network for volumetric medical image segmentation, and HighResNet, a 20-layer residual convolutional neural network, were adopted. 18F-FDG-PET/CT images of 510 patients presenting with head and neck cancer on which manually defined (reference) GTVs were utilized for training, evaluation and testing of these algorithms. The input of these networks (in both training or evaluation phases) were 12×12×12 cm sub-volumes of PET images containing the whole volume of the tumors and the neighboring background radiotracer uptake. These networks were trained to generate a binary mask representing the GTV on the input PET subvolume. Standard segmentation metrics, including Dice similarity and precision were used for performance assessment of these algorithms. HighResNet achieved automated GTV delineation with a Dice index of 0.87±0.04 compared to 0.86±0.06 achieved by V-Net. Despite the close performance of these two approaches, HighResNet exhibited less variability among different subjects as reflected in the smaller standard deviation and significantly higher precision index (0.87±0.07 versus 0.80±0.10). Deep learning techniques, in particular HighResNet algorithm, exhibited promising performance for automated GTV delineation on head and neck PET images. Incorporation of anatomical/structural information, particularly MRI, may result in higher segmentation accuracy or less variability among the different subjects.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"44 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79956025","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
SoC-based Architecture for General Purpose Real-Time Histogram Computation 基于soc的通用实时直方图计算体系结构
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Pub Date : 2020-10-31 DOI: 10.1109/NSS/MIC42677.2020.9508087
E. Ronconi, N. Corna, S. Salgaro, F. Garzetti, N. Lusardi, L. Bucci, A. Geraci
{"title":"SoC-based Architecture for General Purpose Real-Time Histogram Computation","authors":"E. Ronconi, N. Corna, S. Salgaro, F. Garzetti, N. Lusardi, L. Bucci, A. Geraci","doi":"10.1109/NSS/MIC42677.2020.9508087","DOIUrl":"https://doi.org/10.1109/NSS/MIC42677.2020.9508087","url":null,"abstract":"In this contribution we present a novel implementation of a firmware and software bundle for the computation of real-time histograms based on a System-on-Chip (SoC) Linux-based platform. Histograms are basic instruments that turn out to be of fundamental help when it comes not only to single-shot events, but also to collection and elaboration of big amount of data, their shaping and statistical insights coming from the collected measures. Industry and Academia have already proposed many solutions to this need, both in full-custom Application-Specific Integrated Circuits (ASICs) and Field-Programmable Gate Arrays (FPGAs) IP-Cores. However, despite being mostly satisfying in performance, these solutions often lack ease of use, upgrade and interfacing. Moreover, in this particular application, large storage capabilities are needed, in order to guarantee the user the possibility to build large enough histograms. To solve these issues, we present a hybrid hardware and software implementation of a Histogram Maker in an FPGA-based SoC. Its main features are the large available memory accessible through a Direct Memory Access (DMA), the low amount of consumed FPGA resources of the actual hardware Histogram (Histo-Pack), the real-time behavior and the simplified, yet efficient, interface to the ARM core in the Xilinx SoC, hosting a Linux-based Operating System. A set of IP-Cores and libraries relaxes the effort for the interfacing between the two worlds, so that the user-friendly Processing System can be connected to the programmable logic part to exploit its high-performance in an easy and flexible way. The system has been successfully validated on Xilinx Zynq-7000 and Zynq UltraScale+ devices. This opens new opportunities for simple data transfer through advanced interfaces and protocols, data elaboration and analysis, with no need for complex hardware on the Programmable Logic part. The system is able to receive up to 0.3 Gsps with a refresh rate of 1ms.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"93 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76860651","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信