The ORION Chipset for the X-Gamma Imaging Spectrometer Onboard of the THESEUS Space Mission

F. Mele, M. Gandola, M. Grassi, C. Labanti, P. Malcovati, G. Bertuccio
{"title":"The ORION Chipset for the X-Gamma Imaging Spectrometer Onboard of the THESEUS Space Mission","authors":"F. Mele, M. Gandola, M. Grassi, C. Labanti, P. Malcovati, G. Bertuccio","doi":"10.1109/NSS/MIC42677.2020.9508085","DOIUrl":null,"url":null,"abstract":"We present the design of a multichip Application Specific Integrated Circuit (ASIC), named ORION, for the front-end readout of the X-Gamma Imaging Spectrometer (XGIS) on-board the Transient High Energy Sky and Early Universe Surveyor (THESEUS) space mission. The XGIS instrument is composed by two cameras that operate as a wide field deep sky monitors with a broad energy range from 2 keV to 20 MeV, and it is based on a position sensitive double-detection mechanism for image reconstruction, in which a single pixel is constituted by a Thallium activated Cesium Iodide (CsI(Tl)) scintillator crystals and two Silicon Drift Detectors (SDDs) glued at both crystal ends, whose signal is collected, reconstructed and digitized by the presented ORION chipset. In each camera, the ORION chipset is organized in a constellation of 12 800 analog front-end chips (ORION-FE), closely connected to the SDD anodes, and 800 mixed signal multi-channel back-end chips (ORION-BE) for signal processing and digitalization, for a total 25 600 ORION-FE and 1600 ORION-BE in the complete instrument. The back-end chips have two parallelized X and Gamma signal processors, for low-energy and high-energy photons respectively, which allow a tailored optimization on the noise and energy range requirements for each type of event. The chipset has an input dynamic range of 32 fC that allows to process signals with a linearity error below ±1.2% on the Gamma processor, and below ±0.1% on the X processor. The nominal Equivalent Noise Charge (ENC) of the system at -20 °C for an estimated detector leakage current of 0.7 pA is 12.5 el. r.m.s at 1 µs peaking time for the X processor, and 32.9 el. r.m.s. at 3 µs peaking time for the Gamma processor. The simulated power consumption is of 1.55 mW per pixel.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"3 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9508085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We present the design of a multichip Application Specific Integrated Circuit (ASIC), named ORION, for the front-end readout of the X-Gamma Imaging Spectrometer (XGIS) on-board the Transient High Energy Sky and Early Universe Surveyor (THESEUS) space mission. The XGIS instrument is composed by two cameras that operate as a wide field deep sky monitors with a broad energy range from 2 keV to 20 MeV, and it is based on a position sensitive double-detection mechanism for image reconstruction, in which a single pixel is constituted by a Thallium activated Cesium Iodide (CsI(Tl)) scintillator crystals and two Silicon Drift Detectors (SDDs) glued at both crystal ends, whose signal is collected, reconstructed and digitized by the presented ORION chipset. In each camera, the ORION chipset is organized in a constellation of 12 800 analog front-end chips (ORION-FE), closely connected to the SDD anodes, and 800 mixed signal multi-channel back-end chips (ORION-BE) for signal processing and digitalization, for a total 25 600 ORION-FE and 1600 ORION-BE in the complete instrument. The back-end chips have two parallelized X and Gamma signal processors, for low-energy and high-energy photons respectively, which allow a tailored optimization on the noise and energy range requirements for each type of event. The chipset has an input dynamic range of 32 fC that allows to process signals with a linearity error below ±1.2% on the Gamma processor, and below ±0.1% on the X processor. The nominal Equivalent Noise Charge (ENC) of the system at -20 °C for an estimated detector leakage current of 0.7 pA is 12.5 el. r.m.s at 1 µs peaking time for the X processor, and 32.9 el. r.m.s. at 3 µs peaking time for the Gamma processor. The simulated power consumption is of 1.55 mW per pixel.
用于忒修斯太空任务上的x -伽马成像光谱仪的ORION芯片组
我们设计了一种多芯片专用集成电路ORION,用于瞬态高能天空和早期宇宙勘测者(THESEUS)太空任务上的x -伽马成像光谱仪(XGIS)的前端读出。图诚科技仪器由两个摄像头操作作为一个广角深空中监视器与广泛的能源范围从2 keV 20兆电子伏,它是基于位置敏感double-detection图像重建的机制,在一个单一的像素是由碘化铊激活铯(CsI (Tl))闪烁体晶体和两个硅漂移探测器(sdd)粘在晶体两端的信号采集、重构和数字化的猎户座芯片组。在每个相机中,ORION芯片组被组织成一个星座,由12 800个模拟前端芯片(ORION- fe)和800个混合信号多通道后端芯片(ORION- be)组成,用于信号处理和数字化,在整个仪器中总共有25 600个ORION- fe和1600个ORION- be。后端芯片有两个并行的X和Gamma信号处理器,分别用于低能量和高能光子,这允许针对每种类型的事件量身定制优化噪声和能量范围要求。该芯片组的输入动态范围为32 fC,允许处理Gamma处理器线性误差低于±1.2%,X处理器线性误差低于±0.1%的信号。在-20°C下,估计检测器泄漏电流为0.7 pA时,系统的标称等效噪声电荷(ENC)为12.5 el。X处理器的峰值时间为1µs,峰值时间为32.9 μ s。Gamma处理器的峰值时间为3µs。模拟功耗为每像素1.55 mW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信