2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)最新文献

筛选
英文 中文
Patterns in Failure Rate of LV Distribution Components 低压配电元件故障率规律
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-08-17 DOI: 10.1109/TDC.2018.8440440
Maikel H. P. Klerx, J. Morren, H. Slootweg
{"title":"Patterns in Failure Rate of LV Distribution Components","authors":"Maikel H. P. Klerx, J. Morren, H. Slootweg","doi":"10.1109/TDC.2018.8440440","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440440","url":null,"abstract":"In general Distribution System Operators are more focused on Medium Voltage (MV) distribution grids as higher voltage levels contribute more to the average interruption duration than Low Voltage (LV) distribution grids. This focus has led to a reduction of the average interruption duration on MV level, which consequently led to a relative increase in costs and interruption duration on LV level. Therefore DSOs want to have more insight into interruptions on LV level. A first step is to analyse patterns in the failure of LV components. By analysing interruptions and assets it can be concluded that failures on LV level are not (completely) related to age. Also differences in failure rate between components and regions can be observed. These patterns ask for performing a more complex statistical analysis in order to investigate other predictors for outages and for assessing the condition of LV grids.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"1 1","pages":"1-9"},"PeriodicalIF":0.0,"publicationDate":"2018-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83971228","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Comparison of University Departments Regarding Their Area and Load Profile of an Existing Campus 大学院系在现有校园的面积和负荷比较
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-20 DOI: 10.1109/TDC.2018.8440415
D. Maihöfner, T. Plößer, J. Hanson, David Sauerwein, Theresia vom Stein, Christoph Kuhn
{"title":"Comparison of University Departments Regarding Their Area and Load Profile of an Existing Campus","authors":"D. Maihöfner, T. Plößer, J. Hanson, David Sauerwein, Theresia vom Stein, Christoph Kuhn","doi":"10.1109/TDC.2018.8440415","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440415","url":null,"abstract":"The realization of the German Energiewende requires the use of innovative methods. The project EnEff: Stadt: Campus Lichtwiese aims to implement the Energiewende for an exemplary district. With a separated campus of Technische Universitat Darmstadt a suitable quarter is used for the investigations. To fulfill the Energiewende the expertise of electrical engineering, mechanical engineering, architecture and computer science are combined to investigate the energy-efficient development of the campus by the use of intelligent coupling of different energy sectors. The goal of the project is a concept of a self-regulating energy campus, an autonomously operating system. Therefore a simulation model with exact load profiles is needed for the campus. To simultaneously raise awareness of the resident departments, the load profile of each department is analyzed separately. Therefore the buildings of the campus need to be clustered with respect to the departments. Furthermore the lot size of all buildings is analyzed and categorized. The load profiles are measured for different seasonal and social dependance to obtain meaningful data. Measurements are taken at every MV-/LV-transformer of the campus for a week to obtain typical curves for workdays and for the weekend. At last the origin of the discovered high base load is analyzed.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"19 1","pages":"1-9"},"PeriodicalIF":0.0,"publicationDate":"2018-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74090600","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design of a Flexible AC/DC-Link 柔性AC/ dc链路的设计
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-18 DOI: 10.1109/TDC.2018.8440459
A. Burstein, V. Ćuk, E. D. de Jong
{"title":"Design of a Flexible AC/DC-Link","authors":"A. Burstein, V. Ćuk, E. D. de Jong","doi":"10.1109/TDC.2018.8440459","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440459","url":null,"abstract":"Designing a MV distribution-level power link for flexible operation between AC and DC comes with many technical challenges. Of the most glaring are how to: switch between three-phase AC and bipolar DC; ensure N-l contingency; determine protection sensitivity and selectivity; and how to handle space charge build-up. This paper gives a detailed analysis on the challenges and technical solutions to these topics, and offers a design for the flexible DC-link thought to be the most realistic for operation in a real MV distribution grid application.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"38 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82573911","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Tertiary Voltage Unbalance Compensation for 500kV Single Phase Autotransformer Banks 500kV单相自耦组三次电压不平衡补偿
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440349
Lianxiang Tang, P. Zhao
{"title":"Tertiary Voltage Unbalance Compensation for 500kV Single Phase Autotransformer Banks","authors":"Lianxiang Tang, P. Zhao","doi":"10.1109/TDC.2018.8440349","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440349","url":null,"abstract":"In an ungrounded transformer tertiary system, most often the phase-to-ground voltages are slightly unbalanced. Therefore all equipment supplied by the tertiary must have extra insulation to withstand the expected phase-to-ground overvoltages that arise from such unbalance. However, in a recent 3 ⨯ 250MV A single phase transformer bank replacement project, it was found that the tertiary phase-to-ground overvoltages were abnormally high therefore the transformer bank could not be put back into service. After extensive investigation, it was found that the transformer interwinding capacitances and tertiary phase-to-ground capacitances were unbalanced, resulting in excessive unbalance in the tertiary phase-to-ground voltages, which was directly responsible for the overvoltage. A mitigation plan was developed. The plan was to modify the tertiary phase-to-ground capacitances in such a way that the voltage unbalance due to the asymmetry in the inter-winding capacitances cancels the voltage unbalance due to the asymmetry in the phase-to-ground capacitances. Based on theoretical derivation and EMTP simulation, two CVTs (Capacitive Voltage Transformer) were selected from the warehouse and installed on the transformer tertiary. The voltage unbalance was successfully mitigated and the transformer bank was put back into service. The mitigation methodology developed in the project achieved significant cost saving and will have great value in future project development.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"40 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74743753","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Resilience Assessment of Distribution Systems Considering the Effect of Hurricanes 考虑飓风影响的配电系统弹性评估
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440320
Rajatha Bhat, Y. Darestani, A. Shafieezadeh, A. Meliopoulos, R. DesRoches
{"title":"Resilience Assessment of Distribution Systems Considering the Effect of Hurricanes","authors":"Rajatha Bhat, Y. Darestani, A. Shafieezadeh, A. Meliopoulos, R. DesRoches","doi":"10.1109/TDC.2018.8440320","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440320","url":null,"abstract":"High wind speeds during hurricanes cause damage to power distribution lines resulting in power outages that last from days to months, depending on the severity of the storm. This highlights the need for accurate risk assessment procedures for decision making purposes. This paper presents a framework for assessing the hurricane resilience of power distribution systems considering the impact of protective devices on reconfiguration and restoration of the distribution network. The framework is applied to an actual distribution network composed of 7051 wood poles located in southeast of the US. Results indicate that for the distribution network reconfiguration is not effective as there is not enough redundancy in the system. However, by considering the repair prioritization and assigning enough number of repair crews, the system can recover quickly.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"56 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80965564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
An Adaptive Digital Notch Filter Based on Grid Impedance Estimation for Improving LCL Filter Peformance 基于网格阻抗估计的自适应数字陷波滤波器,提高LCL滤波器的性能
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440296
Yuan Jing, A. A. Durra, E. El-Saadany
{"title":"An Adaptive Digital Notch Filter Based on Grid Impedance Estimation for Improving LCL Filter Peformance","authors":"Yuan Jing, A. A. Durra, E. El-Saadany","doi":"10.1109/TDC.2018.8440296","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440296","url":null,"abstract":"In the grid-connected system, LCL filters are playing an important role in eliminating the switching frequency compared with the traditional LC filter. Digital notch filter can be used for solving the resonant frequency problem by cancelling the resonant peak. This paper presents an adaptive digital notch filter based on an estimation controller for the grid impedance and the parameters of the notch filter can be adjusted by the estimated grid impedance value. Moreover, the notch filter design and the system stability is also presented in theoretical analysis. Finally, the simulation results shows effectiveness of the estimation algorithm and digital notch filter's function for active damping.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"17 5 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82826036","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A Review on Control Strategies for Integration of Electric Vehicles with Power Systems 电动汽车与电力系统集成控制策略研究进展
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440139
Prashant Akhade, M. Moghaddami, A. Moghadasi, A. Sarwat
{"title":"A Review on Control Strategies for Integration of Electric Vehicles with Power Systems","authors":"Prashant Akhade, M. Moghaddami, A. Moghadasi, A. Sarwat","doi":"10.1109/TDC.2018.8440139","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440139","url":null,"abstract":"Electric vehicles (EVs) are considered as portable sources of power which can be integrated with any infrastructure, including power grid at different geographical locations, forming a dynamically varying system. Grid-to-vehicle (G2V) and vehicle-to-grid (V2G) connections are considered as essential parts of the future smart grids which can considerably enhance the performance of the system in different aspects. The control strategy for integration of EVs plays a key role in enhancing the performance of power system. The aim of this paper is to study different types of control strategies for integration of electric vehicles with power grid. The control strategies that are used for G2V and V2G connections include multi-agent control, frequency control, aggregated control, virtual synchronous machine-based control, etc. which are reviewed in detail. Detailed comparisons between these control methods are presented in this paper. This paper further highlights the transient stability of power system on both distribution and wide-area levels.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"27 2","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91491669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Recent Advances of FACTS Devices for Power Quality Compensation in Railway Traction Power Supply 铁路牵引电源质量补偿FACTS装置研究进展
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440270
Keng-Weng Lao, M. Wong, S. Santoso
{"title":"Recent Advances of FACTS Devices for Power Quality Compensation in Railway Traction Power Supply","authors":"Keng-Weng Lao, M. Wong, S. Santoso","doi":"10.1109/TDC.2018.8440270","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440270","url":null,"abstract":"In recent years, there is worldwide development in railway transportation and it has gained significant importance. Different flexible alternating current transmission system (FACTS) devices, including static var compensator, static synchronous compensator, and railway power quality conditioner, have been proposed to improve system stability and power quality in railway traction power. With rapid railway growth, further research has been made to enhance the performance of FACTS devices in railway. This paper provides an overview of advances in FACTS devices for applications in railway traction power supply systems. It identifies different FACTS device study for railway traction power supply and make comparisons among them.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"21 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81657151","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Hardware Implementation of R-Goose for Wide-Area Protection and Coordination R-Goose广域保护与协调的硬件实现
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440445
J. Yellajosula, Nishchal Sharma, M. Sundararaman, S. Paudyal, B. Mork
{"title":"Hardware Implementation of R-Goose for Wide-Area Protection and Coordination","authors":"J. Yellajosula, Nishchal Sharma, M. Sundararaman, S. Paudyal, B. Mork","doi":"10.1109/TDC.2018.8440445","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440445","url":null,"abstract":"With the evolution of substation automation standards (IEC61850), it is possible to share protection and control information over wide-area network (WAN). The modern microprocessor based intelligent electronic devices (IEDs) equipped with IEC61850 communication capability allows implementation of wide-area protection and coordination between different substations with the help of virtual local area network (VLAN). IEC 61850-90-1/90-5 offers detailed guidelines on implementing VLAN based communication between substations that would enable to transmit GOOSE messages over WAN. In this paper, the implementation of inter substation coordination via routable GOOSE (R-GOOSE) is demonstrated and distance protection with permissive under reaching transfer trip (PUTT) and interlocking applications between two substations are studied. The main goal of the study is to demonstrate basic R-GOOSE message implementation at a laboratory level for wide-area protection and coordination applications.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"11 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77759306","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Studying the Impact of Distributed Solar PV on Power Systems Using Integrated Transmission and Distribution Models 用输配一体化模型研究分布式太阳能光伏发电对电力系统的影响
2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D) Pub Date : 2018-04-16 DOI: 10.1109/TDC.2018.8440457
Himanshu Jain, B. Palmintier, I. Krad, D. Krishnamurthy
{"title":"Studying the Impact of Distributed Solar PV on Power Systems Using Integrated Transmission and Distribution Models","authors":"Himanshu Jain, B. Palmintier, I. Krad, D. Krishnamurthy","doi":"10.1109/TDC.2018.8440457","DOIUrl":"https://doi.org/10.1109/TDC.2018.8440457","url":null,"abstract":"Rapid growth of distributed energy resources has prompted increasing interest in integrated Transmission (T) and Distribution (D) modeling. This paper presents the results of a distributed generation from solar photovoltaics (DGPV) impact assessment study that was performed using a synthetic T &D model. The primary objective of the study was to present a new approach for DGPV impact assessment, where along with detailed models of transmission and distribution networks, consumer loads were modeled using the physics of end-use equipment, and DGPV was geographically dispersed and connected to the secondary distribution networks. The study highlights (i) how a lack of DGPV forecasting can increase the Area Control Error (ACE) at the transmission level for high penetration levels; and (ii) how capturing transmission voltage changes using integrated T &D can change simulated distribution voltage profiles and voltage regulator operations between integrated T &D and distribution-only simulations.","PeriodicalId":6568,"journal":{"name":"2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"14 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89884436","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信