A balance compensation method based on negative sequence weighted equivalent model of unbalanced load 基于负序加权等效模型的不平衡负荷平衡补偿方法
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378945
Liao Kunyu, Tao Shun, Zhao Lei, Yao Liting, Xiao Xiangning
{"title":"A balance compensation method based on negative sequence weighted equivalent model of unbalanced load","authors":"Liao Kunyu, Tao Shun, Zhao Lei, Yao Liting, Xiao Xiangning","doi":"10.1109/ICHQP.2018.8378945","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378945","url":null,"abstract":"when designing a passive network to compensate unbalanced load, an ideal and balanced voltage source is usually taken to generate the voltage at the point of common coupling (PCC), but the compensation results is not so good due to the unbalance of PCC voltage in real systems. With regard to three- phase three-wire circuit, the system side is equivalent to Thevenin model, and the negative sequence current of the load is decomposed into three parts, after being weighted and allotted into three phases, each part then rotates to the positive sequence. Based on the above procedure, the negative sequence weighted equivalent model of three-phase unbalanced load is established in this paper. With equivalent load parameters, the negative- sequence-weighted formula of passive compensation network parameters is presented utilizing the Steinmetz theory. Since the network parameters are functions of negative-sequence-weights, the proposed compensation method can provide a theoretical basis for optimal balance compensation. Simulation results verify the validity of the equivalent model and compensation method proposed.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"89 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80336106","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Responsibility division optimization for multiple harmonic sources based on the improved hampel weight function 基于改进hampel权函数的多谐源责任划分优化
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378845
Jingzong Zhang, Hongkun Chen, Linghua Zeng, T. Ding
{"title":"Responsibility division optimization for multiple harmonic sources based on the improved hampel weight function","authors":"Jingzong Zhang, Hongkun Chen, Linghua Zeng, T. Ding","doi":"10.1109/ICHQP.2018.8378845","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378845","url":null,"abstract":"A method of harmonic responsibility division is proposed by the combination of background harmonic voltage segmentation and multiple linear regression based on the improved Hampel function in the complex field. The background harmonic voltage is clustered and divided into different data segments, and the multiple linear regression model based on the improved Hampel weight function in the complex field is introduced to further improve the accuracy of harmonic responsibility division. The method proposed is tested on IEEE 13-bus system and a simple experimental circuit respectively. The results show that the proposed method is able to improve the accuracy of harmonic responsibility division, especially under high harmonic voltage fluctuation at the PCC node.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"103 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85854007","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Transient detection in phasor measurement units with kalman filtering 卡尔曼滤波相量测量单元的瞬态检测
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378920
M. de Ápraiz, R. Diego, J. Barros
{"title":"Transient detection in phasor measurement units with kalman filtering","authors":"M. de Ápraiz, R. Diego, J. Barros","doi":"10.1109/ICHQP.2018.8378920","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378920","url":null,"abstract":"This paper presents a method based on the use of the residual of an Extended Kalman filter for step transient detection in phasor measurement units. The residual in a Kalman filter, defined as the difference between the measurement and the estimation, is close to zero when the signal is in stationary state but presents a significant increase at the beginning of a sudden change, when a large mismatch appears between the measurement and the estimation. Comparing the instantaneous magnitude of the residual with an adequate detection threshold, a step transient can be detected in the input signal. The paper studies the performance of the method in the detection of step transients in magnitude and phase angle, power swings, high-frequency transients and transient harmonic distortion in power system networks.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"120 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86174154","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Investigation of high frequency emissions (supraharmonics) from small, grid-tied, photovoltaic inverters of different topologies 不同拓扑结构的小型并网光伏逆变器高频发射(超谐波)的研究
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378926
Dilini Darmawardana, S. Perera, D. Robinson, P. Ciufo, Jan Meyer, M. Klatt, U. Jayatunga
{"title":"Investigation of high frequency emissions (supraharmonics) from small, grid-tied, photovoltaic inverters of different topologies","authors":"Dilini Darmawardana, S. Perera, D. Robinson, P. Ciufo, Jan Meyer, M. Klatt, U. Jayatunga","doi":"10.1109/ICHQP.2018.8378926","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378926","url":null,"abstract":"Due to the increasing number and capacity of grid connected power electronic interfaces associated with distributed generating systems, there is increasing concern on the associated power quality problems. Amongst these, high frequency (HF) emissions (referred to as Supraharmonics) in the range 2–150 kHz has become a topic of growing interest within power quality research communities. An increasingly prominent grid connected devices which can contribute to these HF emissions are the photovoltaic (PV) systems. In this paper, HF emissions from seven small (output power ≤ 10kW), grid-tied, photovoltaic inverters (both single phase inverters and three phase inverter composed of three single phase inverters) are analysed using measurements carried out under controlled conditions in laboratory environments. It is shown that under fixed network conditions, these HF emissions are affected by the MPPT (Maximum Power Point Tracking) voltage and the output power level of the PV inverter. Moreover, a strong correlation between the behaviour of HF emissions and the topologies of inverters was observed; an important factor in developing high frequency models of PV inverters.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"87 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73916524","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
A stochastic study of harmonic voltage distortion considering single-phase photovoltaic inverters 考虑单相光伏逆变器的谐波电压畸变随机研究
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378889
D. Schwanz, T. Busatto, M. Bollen, A. Larsson
{"title":"A stochastic study of harmonic voltage distortion considering single-phase photovoltaic inverters","authors":"D. Schwanz, T. Busatto, M. Bollen, A. Larsson","doi":"10.1109/ICHQP.2018.8378889","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378889","url":null,"abstract":"In this paper, the hosting capacity considering harmonic distortion is estimated for single-phase-connected photovoltaic inverters (PVIs) in low-voltage distribution networks. A stochastic approach is used to calculate the harmonic voltage distortion with each customer in the network. The method has been applied to a 6-customer network for the connection of 2.5-kW single-phase PVIs with and without harmonic voltage background. From the results, it was observed that the contribution from 2.5 kW single-phase photovoltaic inverters to the individual harmonic distortion will not cause the established limits to be exceeded. Also, that the harmonic voltage background is often dominating and should be continuously observed.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"117 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73941410","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Introductory results of tests of algorithms for recreation of voltage variation with voltage fluctuation indices 基于电压波动指数的电压变化再现算法的试验结果介绍
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378910
M. Michalski
{"title":"Introductory results of tests of algorithms for recreation of voltage variation with voltage fluctuation indices","authors":"M. Michalski","doi":"10.1109/ICHQP.2018.8378910","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378910","url":null,"abstract":"The paper presents results of preliminary research on possibility to recreate a variation of voltage in power grid on the basis of recorded values of measures of the variation. This is a complex issue because the voltage changes that occur in real networks are random. Five algorithms have been proposed and their quality has been verified using the obtained values of Pst short-term flicker indicator. Description of the algorithms and results analysis have been preceded by the introduction that aims at short description of selected voltage variation indices.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"87 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75705713","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Comparison of methods using only voltage measurements for detecting the origin of voltage sags in the modern distribution networks 现代配电网中仅用电压测量方法检测电压跌落来源的比较
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378844
C. Noce, M. De Santis, P. Varilone, P. Verde
{"title":"Comparison of methods using only voltage measurements for detecting the origin of voltage sags in the modern distribution networks","authors":"C. Noce, M. De Santis, P. Varilone, P. Verde","doi":"10.1109/ICHQP.2018.8378844","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378844","url":null,"abstract":"In this paper, we analysed two methods, M1 and M2, for determining in which network the voltage sags originated. The problem referred to the High Voltage (HV) and Medium Voltage (MV) systems interconnected by HV/MV stations. The methods were compared using time domain simulations, short circuits were forced on the HV or the MV network, the voltage sags were observed, and M1 and M2 were applied. Comparisons of M1 and M2 behaviours were done for the same network architecture with and without Distributed Generation (DG).","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"35 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72844982","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Impact of voltage sag on electrical system for water pumping of Mae Moh mine 电压暂降对梅磨矿抽水电气系统的影响
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378839
W. Boonkird, S. Premrudeepreechacharn, Y. Baghzouz
{"title":"Impact of voltage sag on electrical system for water pumping of Mae Moh mine","authors":"W. Boonkird, S. Premrudeepreechacharn, Y. Baghzouz","doi":"10.1109/ICHQP.2018.8378839","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378839","url":null,"abstract":"This paper studies the voltage sag on a distribution system that delivers power to an array of water pumps in Mae Moh mine. Mae Moh mine is an open pit mine, therefore, electric pump is a crucial equipment for pumping water out of mine. DIgSILENT's PowerFactory software is used for modeling the electrical system and assessing the severity of voltage sag that is caused by sequential starting of large motors as this might affect some sensitive loads at various buses. Possible solutions are described for the worse cases where the voltage dip is considered unacceptable.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"30 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73135340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimal planning of PV inverter in the presence of capacitor bank in medium-voltage distribution networks 中压配电网中存在电容器组时光伏逆变器的优化规划
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378862
Abdelfatah Ali, D. Raisz, K. Mahmoud
{"title":"Optimal planning of PV inverter in the presence of capacitor bank in medium-voltage distribution networks","authors":"Abdelfatah Ali, D. Raisz, K. Mahmoud","doi":"10.1109/ICHQP.2018.8378862","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378862","url":null,"abstract":"As the penetration level of the photovoltaic (PV) system increases over the coming decades, reverse power flows on the distribution feeder will happen and the associated voltage rise might lead to violations of voltage limits. The severity of the voltage regulation problem depends on the relative size and location of PV system, loads, and the distribution feeder topology. This paper proposes an approach to solve the voltage rise problem associated with PV system and to improve the total voltage deviation by optimally increasing the capacity of the PV inverter over the capacity of the PV modules in the presence of capacitor banks. An optimization model is constructed to calculate the optimal inverter capacity with minimizing the cost of PV inverter as well as the total voltage deviation on the distribution network. The overall system constraints are considered in the optimization model. The proposed approach is tested using the IEEE 119-node distribution network. The effectiveness of the proposed approach is demonstrated by calculating the optimal capacity of the PV inverter for mitigating the voltage rise problem and reducing the total voltage deviation.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"785 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76919236","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Immunity test of LED lamps based on IEC 61000-4 19 and unexpected consequence 基于IEC 61000- 419的LED灯具抗扰度测试及意外后果
2018 18th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2018-05-01 DOI: 10.1109/ICHQP.2018.8378853
S. Sakar, S. Rönnberg, M. Bollen
{"title":"Immunity test of LED lamps based on IEC 61000-4 19 and unexpected consequence","authors":"S. Sakar, S. Rönnberg, M. Bollen","doi":"10.1109/ICHQP.2018.8378853","DOIUrl":"https://doi.org/10.1109/ICHQP.2018.8378853","url":null,"abstract":"LED lighting technology is the most efficient way of lighting service and its usage has increased rapidly. Although, LED lamps are potential victim and source of electromagnetic interference in the frequency range between 2 kHz and 150 kHz (“supraharmonics”). Therefore, immunity test for this frequency range is necessary to analyze its performance variations. In this study, Test profiles described in IEC 61000-4-19 have been applied to LED lamps and the results have been analyzed according to implemented algorithm that uses the relative light intensity variation index. The results show that both supraharmonics and modulation of the test profiles can reveal light flicker. In addition, some potential drawbacks of the standard have been found that deviation of the mains' frequency is also another factor causes intermodulation/non- synchronization on the applied test signal, so this can be seen as light flicker. This issue better be clarified with more details in the IEC 61000-4-19, particalulary for lighting equipment","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"265 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75917056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信