{"title":"考虑单相光伏逆变器的谐波电压畸变随机研究","authors":"D. Schwanz, T. Busatto, M. Bollen, A. Larsson","doi":"10.1109/ICHQP.2018.8378889","DOIUrl":null,"url":null,"abstract":"In this paper, the hosting capacity considering harmonic distortion is estimated for single-phase-connected photovoltaic inverters (PVIs) in low-voltage distribution networks. A stochastic approach is used to calculate the harmonic voltage distortion with each customer in the network. The method has been applied to a 6-customer network for the connection of 2.5-kW single-phase PVIs with and without harmonic voltage background. From the results, it was observed that the contribution from 2.5 kW single-phase photovoltaic inverters to the individual harmonic distortion will not cause the established limits to be exceeded. Also, that the harmonic voltage background is often dominating and should be continuously observed.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"117 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A stochastic study of harmonic voltage distortion considering single-phase photovoltaic inverters\",\"authors\":\"D. Schwanz, T. Busatto, M. Bollen, A. Larsson\",\"doi\":\"10.1109/ICHQP.2018.8378889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the hosting capacity considering harmonic distortion is estimated for single-phase-connected photovoltaic inverters (PVIs) in low-voltage distribution networks. A stochastic approach is used to calculate the harmonic voltage distortion with each customer in the network. The method has been applied to a 6-customer network for the connection of 2.5-kW single-phase PVIs with and without harmonic voltage background. From the results, it was observed that the contribution from 2.5 kW single-phase photovoltaic inverters to the individual harmonic distortion will not cause the established limits to be exceeded. Also, that the harmonic voltage background is often dominating and should be continuously observed.\",\"PeriodicalId\":6506,\"journal\":{\"name\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"117 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2018.8378889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A stochastic study of harmonic voltage distortion considering single-phase photovoltaic inverters
In this paper, the hosting capacity considering harmonic distortion is estimated for single-phase-connected photovoltaic inverters (PVIs) in low-voltage distribution networks. A stochastic approach is used to calculate the harmonic voltage distortion with each customer in the network. The method has been applied to a 6-customer network for the connection of 2.5-kW single-phase PVIs with and without harmonic voltage background. From the results, it was observed that the contribution from 2.5 kW single-phase photovoltaic inverters to the individual harmonic distortion will not cause the established limits to be exceeded. Also, that the harmonic voltage background is often dominating and should be continuously observed.