Sepideh Hatamikia , Laszlo Jaksa , Gernot Kronreif , Wolfgang Birkfellner , Joachim Kettenbach , Martin Buschmann , Andrea Lorenz
{"title":"Silicone phantoms fabricated with multi-material extrusion 3D printing technology mimicking imaging properties of soft tissues in CT","authors":"Sepideh Hatamikia , Laszlo Jaksa , Gernot Kronreif , Wolfgang Birkfellner , Joachim Kettenbach , Martin Buschmann , Andrea Lorenz","doi":"10.1016/j.zemedi.2023.05.007","DOIUrl":"10.1016/j.zemedi.2023.05.007","url":null,"abstract":"<div><div>Recently, 3D printing has been widely used to fabricate medical imaging phantoms. So far, various rigid 3D printable materials have been investigated for their radiological properties and efficiency in imaging phantom fabrication. However, flexible, soft tissue materials are also needed for imaging phantoms for simulating several clinical scenarios where anatomical deformations is important. Recently, various additive manufacturing technologies have been used to produce anatomical models based on extrusion techniques that allow the fabrication of soft tissue materials. To date, there is no systematic study in the literature investigating the radiological properties of silicone rubber materials/fluids for imaging phantoms fabricated directly by extrusion using 3D printing techniques. The aim of this study was to investigate the radiological properties of 3D printed phantoms made of silicone in CT imaging. To achieve this goal, the radiodensity as described as Hounsfield Units (HUs) of several samples composed of three different silicone printing materials were evaluated by changing the infill density to adjust their radiological properties. A comparison of HU values with a Gammex Tissue Characterization Phantom was performed. In addition, a reproducibility analysis was performed by creating several replicas for specific infill densities. A scaled down anatomical model derived from an abdominal CT was also fabricated and the resulting HU values were evaluated. For the three different silicone materials, a spectrum ranging from −639 to +780 HU was obtained on CT at a scan setting of 120 kVp. In addition, using different infill densities, the printed materials were able to achieve a similar radiodensity range as obtained in different tissue-equivalent inserts in the Gammex phantom (238 HU to −673 HU). The reproducibility results showed good agreement between the HU values of the replicas compared to the original samples, confirming the reproducibility of the printed materials. A good agreement was observed between the HU target values in abdominal CT and the HU values of the 3D-printed anatomical phantom in all tissues.</div></div>","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 2","pages":"Pages 138-151"},"PeriodicalIF":2.4,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9695484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Characterization of a new radiochromic film (LD-V1) using mammographic beam qualities","authors":"Erika Nakajima, Hitoshi Sato","doi":"10.1016/j.zemedi.2023.05.004","DOIUrl":"10.1016/j.zemedi.2023.05.004","url":null,"abstract":"<div><h3>Purpose</h3><div>Radiochromic film (RCF) is a detector that can obtain a two-dimensional dose distribution with high resolution; it is widely used in medical and industrial fields. Several types of RCFs exist based on their application. The type of RCF mainly used for mammography dose assessment has been discontinued; however, a new type of RCF (LD-V1) has been distributed as a successor. Since the medical use of LD-V1 has rarely been studied, we investigated the response characteristics of LD-V1 in mammography.</div></div><div><h3>Methods</h3><div>Measurements were performed using Mo/Mo and Rh/Ag on a Senographe Pristina mammography device (GE, Fairfield, CT, USA). The reference air kerma was measured using a parallel-plate ionization chamber (PPIC) (C-MA, Applied Engineering Inc, Tokyo, Japan). Pieces of LD-V1 film model were irradiated at the same position where the reference air kerma in air was measured by the PPIC. Irradiation was performed using the time scale method based on the load on the equipment. Two methods of irradiation were considered: placing the detector in air and on the phantom. The LD-V1 was scanned five times at 72 dpi in RGB (48 bit) mode using a flatbed scanner (ES-G11000, Seiko Epson Corp, Nagano, Japan) 24 h following irradiation. The response ratio of the reference air kerma and the air kerma obtained from the LD-V1 were compared and examined for each beam quality and air kerma range.</div></div><div><h3>Results and discussion</h3><div>When the beam quality was altered, the response ratio varied from 0.8 to 1.2 with respect to the measurement value of the PPIC; however, some outliers were observed. Response ratios were highly variable in the low-dose range; however, as the air kerma increased, the ratios approached 1. Thus, LD-V1 does not need calibration for each beam quality used in mammography. LD-V1 enables air kerma evaluation by creating air kerma response curves under certain X-ray conditions used in mammography.</div></div><div><h3>Conclusion</h3><div>We suggest that the dose range be limited to 12 mGy or more to keep the response variation with beam qualities below ±20%. If further measurement is required for reducing the response variation, the dose range should be shifted to a higher dose range.</div></div>","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 2","pages":"Pages 169-176"},"PeriodicalIF":2.4,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9680258","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yinxiangzi Sheng , Lennart Volz , Weiwei Wang , Marco Durante , Christian Graeff
{"title":"Evaluation of proton and carbon ion beam models in TReatment Planning for Particles 4D (TRiP4D) referring to a commercial treatment planning system","authors":"Yinxiangzi Sheng , Lennart Volz , Weiwei Wang , Marco Durante , Christian Graeff","doi":"10.1016/j.zemedi.2023.06.002","DOIUrl":"10.1016/j.zemedi.2023.06.002","url":null,"abstract":"<div><h3>Purpose</h3><div>To investigate the accuracy of the treatment planning system (TPS) TRiP4D in reproducing doses computed by the clinically used TPS SyngoRT.</div></div><div><h3>Methods</h3><div>Proton and carbon ion beam models in TRiP4D were converted from SyngoRT. Cubic plans with different depths in a water-tank phantom (WP) and previously treated and experimentally verified patient plans from SyngoRT were recalculated in TRiP4D. The target mean dose deviation (ΔD<sub>mean,T</sub>) and global gamma index (2%–2 mm for the absorbed dose and 3%–3mm for the RBE-weighted dose with 10% threshold) were evaluated.</div></div><div><h3>Results</h3><div>The carbon and proton absorbed dose gamma passing rates (γ-PRs) were ≥99.93% and ΔD<sub>mean,T</sub> smaller than −0.22%. On average, the RBE-weighted dose D<sub>mean,T</sub> was −1.26% lower for TRiP4D than SyngoRT for cubic plans. In TRiP4D, the faster analytical ‘low dose approximation’ (Krämer, 2006) was used, while SyngoRT used a stochastic implementation (Krämer, 2000). The average ΔD<sub>mean, T</sub> could be reduced to −0.59% when applying the same biological effect calculation algorithm. However, the dose recalculation time increased by a factor of 79–477. ΔD<sub>mean,T</sub> variation up to −2.27% and −2.79% was observed for carbon absorbed and RBE-weighted doses in patient plans. The γ-PRs were ≥93.92% and ≥91.83% for patient plans, except for one proton beam with a range shifter (γ-PR of 64.19%).</div></div><div><h3>Conclusion</h3><div>The absorbed dose between TRiP4D and SyngoRT were identical for both proton and carbon ion plans in the WP. Compared to SyngoRT, TRiP4D underestimated the target RBE-weighted dose; however more efficient in RBE-weighted dose calculation. Large variation for proton beam with range shifter was observed. TRiP4D will be used to evaluate doses delivered to moving targets. Uncertainties inherent to the 4D-dose reconstruction calculation are expected to be significantly larger than the dose errors reported here. For this reason, the residual differences between TRiP4D and SyngoRT observed in this study are considered acceptable.</div><div>The study was approved by the Institutional Research Board of Shanghai Proton and Heavy Ion Center (approval number SPHIC-MP-2020-04, RS).</div></div>","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 2","pages":"Pages 218-226"},"PeriodicalIF":2.4,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9781743","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Lena Nohava, Michael Obermann, Roberta Frass-Kriegl, Onisim Soanca, Elmar Laistler
{"title":"A modular system of flexible receive-only coil arrays for 3 T Magnetic Resonance Imaging","authors":"Lena Nohava, Michael Obermann, Roberta Frass-Kriegl, Onisim Soanca, Elmar Laistler","doi":"10.1016/j.zemedi.2023.05.002","DOIUrl":"10.1016/j.zemedi.2023.05.002","url":null,"abstract":"<div><div>Flexible form-fitting radiofrequency coils provide high signal-to-noise ratio (SNR) for magnetic resonance imaging (MRI), and in array configuration large anatomical areas of interest can be covered. We propose a modular system - “ModFlex”- of flexible lightweight 4-channel coaxial coil arrays for 3 T MRI. We investigated the performance difference between commercial reference coils and 8- and 16-channel ModFlex receive-only array systems. In vivo, six anatomical targets in four regions of interest – the neck, the ankle, the spine and the hip – were imaged with the novel coil array system. The versatility of ModFlex and the robustness of the coil characteristics for different use cases is demonstrated. We measured an SNR gain for 4 out of 6 and similar SNR for 2 out of 6 anatomical target regions as compared to commercial reference coils. Parallel imaging capabilities are comparable to standard coils in hip and neck imaging, but ModFlex outperforms standard coils in ankle and spine imaging. High SNR combined with high acceleration possibilities enables faster imaging workflows and/or high-resolution MR acquisitions. The coil’s versatility is beneficial for use cases with varying subject sizes and could improve patient comfort.</div></div>","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 2","pages":"Pages 193-203"},"PeriodicalIF":2.4,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9545731","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Roya Afshari , Francesco Santini , Rahel Heule , Craig H. Meyer , Josef Pfeuffer , Oliver Bieri
{"title":"Rapid whole-brain quantitative MT imaging","authors":"Roya Afshari , Francesco Santini , Rahel Heule , Craig H. Meyer , Josef Pfeuffer , Oliver Bieri","doi":"10.1016/j.zemedi.2023.02.005","DOIUrl":"10.1016/j.zemedi.2023.02.005","url":null,"abstract":"<div><h3>Purpose</h3><div>To provide a robust whole-brain quantitative magnetization transfer (MT) imaging method that is not limited by long acquisition times.</div></div><div><h3>Methods</h3><div>Two variants of a spiral 2D interleaved multi-slice spoiled gradient echo (SPGR) sequence are used for rapid quantitative MT imaging of the brain at 3 T. A dual flip angle, steady-state prepared, double-contrast method is used for combined B<sub>1</sub> and-T<sub>1</sub> mapping in combination with a single-contrast MT-prepared acquisition over a range of different saturation flip angles (50 deg to 850 deg) and offset frequencies (1 kHz and 10 kHz). Five sets (containing minimum 6 to maximum 18 scans) with different MT-weightings were acquired. In addition, main magnetic field inhomogeneities (ΔB<sub>0</sub>) were measured from two Cartesian low-resolution 2D SPGR scans with different echo times. Quantitative MT model parameters were derived from all sets using a two-pool continuous-wave model analysis, yielding the pool-size ratio, F, their exchange rate, k<sub>f</sub>, and their transverse relaxation time, T<sub>2r</sub>.</div></div><div><h3>Results</h3><div>Whole-brain quantitative MT imaging was feasible for all sets with total acquisition times ranging from 7:15 min down to 3:15 min. For accurate modeling, B<sub>1</sub>-correction was essential for all investigated sets, whereas ΔB<sub>0</sub>-correction showed limited bias for the observed maximum off-resonances at 3 T.</div></div><div><h3>Conclusion</h3><div>The combination of rapid B<sub>1</sub>-T<sub>1</sub> mapping and MT-weighted imaging using a 2D multi-slice spiral SPGR research sequence offers excellent prospects for rapid whole-brain quantitative MT imaging in the clinical setting.</div></div>","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 1","pages":"Pages 69-77"},"PeriodicalIF":2.4,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9252608","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
George Dedes , Jannis Dickmann , Valentina Giacometti , Simon Rit , Nils Krah , Sebastian Meyer , Vladimir Bashkirov , Reinhard Schulte , Robert P. Johnson , Katia Parodi , Guillaume Landry
{"title":"Erratum to “The role of Monte Carlo simulation in understanding the performance of proton computed tomography” [Z Med Phys 32 (2022) 23–38]","authors":"George Dedes , Jannis Dickmann , Valentina Giacometti , Simon Rit , Nils Krah , Sebastian Meyer , Vladimir Bashkirov , Reinhard Schulte , Robert P. Johnson , Katia Parodi , Guillaume Landry","doi":"10.1016/j.zemedi.2024.07.012","DOIUrl":"10.1016/j.zemedi.2024.07.012","url":null,"abstract":"","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 1","pages":"Page 109"},"PeriodicalIF":2.4,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142127879","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Michaela A.U. Hoesl , Lothar R. Schad , Stanislas Rapacchi
{"title":"Erratum to “Volumetric 23Na single and triple-quantum imaging at 7T: 3D-CRISTINA” [Z Med Phys 32 (2022) 199–208]","authors":"Michaela A.U. Hoesl , Lothar R. Schad , Stanislas Rapacchi","doi":"10.1016/j.zemedi.2024.07.008","DOIUrl":"10.1016/j.zemedi.2024.07.008","url":null,"abstract":"","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 1","pages":"Page 113"},"PeriodicalIF":2.4,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142127880","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ke Zhang , Simon M.F. Triphan , Mark O. Wielpütz , Christian H. Ziener , Mark E. Ladd , Heinz-Peter Schlemmer , Hans-Ulrich Kauczor , Oliver Sedlaczek , Felix T. Kurz
{"title":"Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation","authors":"Ke Zhang , Simon M.F. Triphan , Mark O. Wielpütz , Christian H. Ziener , Mark E. Ladd , Heinz-Peter Schlemmer , Hans-Ulrich Kauczor , Oliver Sedlaczek , Felix T. Kurz","doi":"10.1016/j.zemedi.2024.06.001","DOIUrl":"10.1016/j.zemedi.2024.06.001","url":null,"abstract":"<div><h3>Purpose</h3><div>To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free–breathing liver perfusion measurement without contrast agent.</div></div><div><h3>Methods</h3><div>Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were applied as labeling and control pulses. In order to account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI based readouts, navigator and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. The sinc-VSI without velocity-selective gradients during the control condition but with velocity-selective gradients along all three directions during labeling was chosen for the VSASL. The VSASL was compared with pseudo-continuous ASL (pCASL) methods, which selectively tagged the moving spins using a tagging plane placed at the portal vein and hepatic artery.</div></div><div><h3>Results</h3><div>The motion caused by respiratory activity was effectively computed using the navigator signal. The coefficients of variation (CoV) of average liver voxel in NAV were significantly decreased when compared to breath-hold (BH), with an average reduction of 29.4 ± 18.44% for control images, and 29.89 ± 20.83% for label images (p < 0.001). The resulting maps of normalized ASL signal (normalized to M<sub>0</sub>) showed significantly higher perfusion weightings in the NAV-compensated VSASL, when compared to the NAV-compensated pCASL techniques.</div></div><div><h3>Conclusions</h3><div>This study demonstrates the feasibility of using a navigator-based prospective motion compensation technique in conjunction with VSASL for the measurement of liver perfusion without the use of contrast agents while allowing for free-breathing.</div></div>","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 1","pages":"Pages 87-97"},"PeriodicalIF":2.4,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141500136","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Gerd Heilemann , Mark Matthewman , Peter Kuess , Gregor Goldner , Joachim Widder , Dietmar Georg , Lukas Zimmermann
{"title":"Erratum to “Can Generative Adversarial Networks help to overcome the limited data problem in segmentation?” [Z Med Phys 32 (2022) 361–368]","authors":"Gerd Heilemann , Mark Matthewman , Peter Kuess , Gregor Goldner , Joachim Widder , Dietmar Georg , Lukas Zimmermann","doi":"10.1016/j.zemedi.2024.07.006","DOIUrl":"10.1016/j.zemedi.2024.07.006","url":null,"abstract":"","PeriodicalId":54397,"journal":{"name":"Zeitschrift fur Medizinische Physik","volume":"35 1","pages":"Page 115"},"PeriodicalIF":2.4,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142127873","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}