Journal of Advanced Prosthodontics最新文献

筛选
英文 中文
Effect of barium silicate filler content on mechanical properties of resin nanoceramics for additive manufacturing. 硅酸钡填料含量对增材制造用树脂纳米陶瓷力学性能的影响。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-10-01 Epub Date: 2022-10-28 DOI: 10.4047/jap.2022.14.5.315
Sun Won, Kyung-Ho Ko, Chan-Jin Park, Lee-Ra Cho, Yoon-Hyuk Huh
{"title":"Effect of barium silicate filler content on mechanical properties of resin nanoceramics for additive manufacturing.","authors":"Sun Won,&nbsp;Kyung-Ho Ko,&nbsp;Chan-Jin Park,&nbsp;Lee-Ra Cho,&nbsp;Yoon-Hyuk Huh","doi":"10.4047/jap.2022.14.5.315","DOIUrl":"https://doi.org/10.4047/jap.2022.14.5.315","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to investigate the effect of barium silicate filler contents on mechanical properties of resin nanoceramics (RNCs) for additive manufacturing (AM).</p><p><strong>Materials and methods: </strong>Additively manufactured RNC specimens were divided into 4 groups depending on the content of ceramic fillers and polymers: 0% barium silicate and 100% polymer (B0/P10, control group); 50% barium silicate and 50% polymer (B5/P5); 60% barium silicate and 40% polymer (B6/P4); 67% barium silicate and 33% polymer (B6.7/P3.3). The compressive strength (n = 15) and fracture toughness (n = 12) of the specimens were measured, and scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS) analyses were performed. Independent sample Kruskal-Wallis tests were performed on the compressive strength and fracture toughness test results, and the significance of each group was analyzed at the 95% confidence interval through post-tests using the Bonferroni's method.</p><p><strong>Results: </strong>B6/P4 and B6.7/P3.3 exhibited much higher yield strength than B0/P10 and B5/P5 (<i>P</i> < .05). Compared to the control group (B0/P10), the other three groups exhibited higher ultimate strength (<i>P</i> < .05). The fracture toughness of B6/P4 and B6.7/P3.3 were similar (<i>P</i> > .05). The content of barium silicate and fracture toughness showed a positive correlation coefficient (R = 0.582). SEM and EDS analyses revealed the presence of an oval-shaped ceramic aggregate in B6/P4 specimens, whereas the ceramic filler and polymer substrate were homogeneously mixed in B6.7/P3.3.</p><p><strong>Conclusion: </strong>Increasing the ceramic filler content improves the mechanical properties, but it can be accompanied by a decrease in the flowability and the homogeneity of the slurry.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 5","pages":"315-323"},"PeriodicalIF":2.6,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/29/12/jap-14-315.PMC9672694.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40491185","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Erratum - Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium. 校正- 3d打印义齿树脂的颜色稳定性:老化,机械刷刷和浸泡在染色介质中的影响。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-10-01 Epub Date: 2022-10-28 DOI: 10.4047/jap.2022.14.5.334
{"title":"Erratum - Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium.","authors":"","doi":"10.4047/jap.2022.14.5.334","DOIUrl":"https://doi.org/10.4047/jap.2022.14.5.334","url":null,"abstract":"<p><p>[This corrects the article on p. 160 in vol. 13, PMID: 34234926.].</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 5","pages":"334"},"PeriodicalIF":2.6,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/30/jap-14-334.PMC9672695.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40491188","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Translucency and masking ability of translucent zirconia; comparison with conventional zirconia and lithium disilicate. 半透明氧化锆的半透明性和掩蔽能力与常规氧化锆和二硅酸锂的比较。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-10-01 Epub Date: 2022-10-28 DOI: 10.4047/jap.2022.14.5.324
Joon Hee Park, Hyun Ji Bang, Nak-Hyun Choi, Eun-Jin Park
{"title":"Translucency and masking ability of translucent zirconia; comparison with conventional zirconia and lithium disilicate.","authors":"Joon Hee Park,&nbsp;Hyun Ji Bang,&nbsp;Nak-Hyun Choi,&nbsp;Eun-Jin Park","doi":"10.4047/jap.2022.14.5.324","DOIUrl":"https://doi.org/10.4047/jap.2022.14.5.324","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study is to evaluate translucency and masking ability of translucent zirconia compared to conventional zirconia and lithium disilicate materials.</p><p><strong>Materials and methods: </strong>Three types of zirconia blocks with different yttria contents (3Y, 4Y, 5.5Y) and LS blocks (Rosetta SM) were used. Ten specimens for each group were fabricated with 10 mm diameter, with both 0.8 mm and 1.5 mm thicknesses (± 0.02 mm). All groups of zirconia specimens were sintered and polished according to the manufacturer's instructions. To calculate the translucency parameter (TP), CIELAB value was measured with a spectrophotometer on black and white backgrounds. To investigate the color masking abilities, background shades of A2, normal dentin, discolored dentin, and titanium were used. The color difference (ΔE) was calculated with the CIELAB values of A2 shade background as a reference compared with the values in the various backgrounds. One-way ANOVA and Bonferroni tests were conducted (<i>P</i> < .05).</p><p><strong>Results: </strong>The TP values of zirconia specimens increased as the yttria content increased. All materials used in the study were able to adequately mask normal dentin shade (ΔE < 5.5), but were incapable of masking severely discolored dentin (ΔE > 5.5). On the titanium background, all materials of 1.5 mm thickness were able to mask the background shade, but with a thickness of 0.8 mm, only 3Y-TZP and 4Y-PSZ were able to mask titanium background.</p><p><strong>Conclusion: </strong>All zirconia materials and lithium disilicate specimens used in this study were unable to adequately mask the shade of severely discolored dentin. It is recommended to use 3Y-TZP or 4Y-PSZ with a sufficient thickness of 0.8 mm or more to mask titanium.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 5","pages":"324-333"},"PeriodicalIF":2.6,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bd/5b/jap-14-324.PMC9672692.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40491184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study. 腭穹窿形态对全无牙弓的口腔内扫描时间和准确性有影响吗?一项体外研究。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-10-01 Epub Date: 2022-10-28 DOI: 10.4047/jap.2022.14.5.294
Reham Osman, Nawal Alharbi
{"title":"Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An <i>in-vitro</i> study.","authors":"Reham Osman,&nbsp;Nawal Alharbi","doi":"10.4047/jap.2022.14.5.294","DOIUrl":"https://doi.org/10.4047/jap.2022.14.5.294","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches.</p><p><strong>Materials and methods: </strong>Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights-Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3Shape™, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05.</p><p><strong>Results: </strong>The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (<i>P</i> =.959 and <i>P</i> =.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III.</p><p><strong>Conclusion: </strong>The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 5","pages":"294-304"},"PeriodicalIF":2.6,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f7/3b/jap-14-294.PMC9672697.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40491187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments. CAD-CAM种植基台三级超声处理方案的微生物清洁和消毒效果。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-10-01 Epub Date: 2022-10-28 DOI: 10.4047/jap.2022.14.5.273
Peter Gehrke, Oliver Riebe, Carsten Fischer, Octavio Weinhold, Günter Dhom, Robert Sader, Paul Weigl
{"title":"Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments.","authors":"Peter Gehrke,&nbsp;Oliver Riebe,&nbsp;Carsten Fischer,&nbsp;Octavio Weinhold,&nbsp;Günter Dhom,&nbsp;Robert Sader,&nbsp;Paul Weigl","doi":"10.4047/jap.2022.14.5.273","DOIUrl":"https://doi.org/10.4047/jap.2022.14.5.273","url":null,"abstract":"<p><strong>Purpose: </strong>Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments.</p><p><strong>Materials and methods: </strong>Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and <i>E. faecium</i> were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU).</p><p><strong>Results: </strong>Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 µg and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection.</p><p><strong>Conclusion: </strong>A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 5","pages":"273-284"},"PeriodicalIF":2.6,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/50/jap-14-273.PMC9672693.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40491189","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns. 后牙无牙区种植体修复的临床效果回顾性比较:2个种植体支撑的3单元桥与3个种植体支撑的夹板冠。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-08-01 Epub Date: 2022-08-29 DOI: 10.4047/jap.2022.14.4.223
Yuseung Yi, Seong-Joo Heo, Jai-Young Koak, Seong-Kyun Kim
{"title":"A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns.","authors":"Yuseung Yi,&nbsp;Seong-Joo Heo,&nbsp;Jai-Young Koak,&nbsp;Seong-Kyun Kim","doi":"10.4047/jap.2022.14.4.223","DOIUrl":"https://doi.org/10.4047/jap.2022.14.4.223","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the clinical outcomes of two types of implant restoration for posterior edentulous area, 3-unit bridge supported by 2 implants and 3 implant-supported splinted crowns.</p><p><strong>Materials and methods: </strong>The data included 127 implant-supported fixed restorations in 85 patients: 37 restorations of 3-unit bridge supported by 2 implants (2-IB), 37 restorations of 3 implant-supported splinted crowns (3-IC), and 53 single restorations (S) as controls. Peri-implantitis and mechanical complications that occurred for 14 years were analyzed by multivariable Cox regression model. Kaplan-Meier curves and the multivariable Cox regression model were used to analyze the success and survival of implants.</p><p><strong>Results: </strong>Peri-implantitis occurred in 28.4% of 2-IB group, 37.8% of 3-IC group, and 28.3% of S control group with no significant difference. According to the implant position, middle implants (P2) of the 3-IC group had the highest risk of peri-implantitis. The 3-IC group showed a lower mechanical complication rate (7.2%) than the 2-IB (16.2%) and S control group (20.8%). The cumulative success rate was 52.8% in S (control) group, 62.2% in 2-IB group, and 60.4% in 3-IC group. The cumulative survival rate was 98.1% in S (control) group, 98.6% in 2-IB group, and 95.5% in 3-IC group. There was no significant difference in the success and survival rate according to the restoration type.</p><p><strong>Conclusion: </strong>The restoration type was not associated with the success and survival of implants. The risk of mechanical complications was reduced in 3 implant-supported splinted crowns. However, the middle implants of the 3 implant-supported splinted crowns had a higher risk of peri-implantitis.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 4","pages":"223-235"},"PeriodicalIF":2.6,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d3/5c/jap-14-223.PMC9444481.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40358825","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction. 全弓种植体支撑固定假体的常规和数字印模:时间、数量、效果和患者满意度。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-08-01 Epub Date: 2022-08-29 DOI: 10.4047/jap.2022.14.4.212
Ana Larisse Carneiro Pereira, Vitória Ramos Medeiros, Maria de Fátima Trindade Pinto Campos, Annie Karoline Bezerra de Medeiros, Burak Yilmaz, Adriana da Fonte Porto Carreiro
{"title":"Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction.","authors":"Ana Larisse Carneiro Pereira,&nbsp;Vitória Ramos Medeiros,&nbsp;Maria de Fátima Trindade Pinto Campos,&nbsp;Annie Karoline Bezerra de Medeiros,&nbsp;Burak Yilmaz,&nbsp;Adriana da Fonte Porto Carreiro","doi":"10.4047/jap.2022.14.4.212","DOIUrl":"https://doi.org/10.4047/jap.2022.14.4.212","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed complete-arch frameworks, as well as on patient satisfaction.</p><p><strong>Materials and methods: </strong>17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (<i>P</i> < .05).</p><p><strong>Results: </strong>The time with DI was shorter than with CI (DI, x̃=02:58; CI, x̃=31:48) (<i>P</i> < .0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: x̃=05:36; 4: x̃=09:16) (<i>P</i> < .0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (<i>P</i> < .005).</p><p><strong>Conclusion: </strong>Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 4","pages":"212-222"},"PeriodicalIF":2.6,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/fa/d3/jap-14-212.PMC9444484.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40358824","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses. 不同构建方向和层厚的3d打印三单元树脂假体边缘配合研究。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-08-01 Epub Date: 2022-08-29 DOI: 10.4047/jap.2022.14.4.250
Min-Seong Yang, Seong-Kyun Kim, Seong-Joo Heo, Jai-Young Koak, Ji-Man Park
{"title":"Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses.","authors":"Min-Seong Yang,&nbsp;Seong-Kyun Kim,&nbsp;Seong-Joo Heo,&nbsp;Jai-Young Koak,&nbsp;Ji-Man Park","doi":"10.4047/jap.2022.14.4.250","DOIUrl":"https://doi.org/10.4047/jap.2022.14.4.250","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to analyze the marginal fit of three-unit resin prostheses printed with the stereolithography (SLA) method in two build orientations (45°, 60°) and two layer thicknesses (50 µm, 100 µm).</p><p><strong>Materials and methods: </strong>A master model for a three-unit resin prosthesis was designed with two implant abutments. Forty specimens were printed using an SLA 3D printer. The specimens were printed with two build orientations (45°, 60°), and each orientation was printed with two layer thicknesses (50 µm, 100 µm). The marginal fit was measured as the marginal gap (MG) and absolute marginal discrepancy (AMD), and MG and AMD measurements were performed at 8 points per abutment, for 16 points per specimen. All statistical analyses were performed using SPSS software. Two-way analysis of variance (ANOVA) was separately performed on the MG and AMD values of the build orientations and layer thicknesses. Moreover, one-way ANOVA was performed for each point within each group.</p><p><strong>Results: </strong>The margins of the area adjacent to the pontic showed significantly high values, and the values were smaller when the build orientation was 45° than when it was 60°. However, the margin did not differ significantly according to the layer thicknesses.</p><p><strong>Conclusion: </strong>The marginal fit of the three-unit resin prosthesis fabricated by the SLA 3D method was affected by the pontic. Moreover, the marginal fit was affected by the build orientation. The 45° build orientation is recommended.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 4","pages":"250-261"},"PeriodicalIF":2.6,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ea/ed/jap-14-250.PMC9444483.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40358826","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base. 表面处理对内衬材料与3d打印义齿基托剪切结合强度的影响。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-08-01 Epub Date: 2022-08-29 DOI: 10.4047/jap.2022.14.4.262
Se-Jick Park, Joon-Seok Lee
{"title":"Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base.","authors":"Se-Jick Park,&nbsp;Joon-Seok Lee","doi":"10.4047/jap.2022.14.4.262","DOIUrl":"https://doi.org/10.4047/jap.2022.14.4.262","url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment.</p><p><strong>Materials and methods: </strong>Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (<i>P</i> < .05).</p><p><strong>Results: </strong>Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS.</p><p><strong>Conclusion: </strong>The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 4","pages":"262-272"},"PeriodicalIF":2.6,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d5/49/jap-14-262.PMC9444486.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40358827","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations. 数字和传统植入物印模之间的准确性比较:二维和三维评估。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2022-08-01 Epub Date: 2022-08-29 DOI: 10.4047/jap.2022.14.4.236
Chuang Bi, Xingyu Wang, Fangfang Tian, Zhe Qu, Jiaming Zhao
{"title":"Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations.","authors":"Chuang Bi,&nbsp;Xingyu Wang,&nbsp;Fangfang Tian,&nbsp;Zhe Qu,&nbsp;Jiaming Zhao","doi":"10.4047/jap.2022.14.4.236","DOIUrl":"https://doi.org/10.4047/jap.2022.14.4.236","url":null,"abstract":"<p><strong>Purpose: </strong>The present study compared the accuracy between digital and conventional implant impressions.</p><p><strong>Materials and methods: </strong>The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data.</p><p><strong>Results: </strong>Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (<i>P</i><.001).</p><p><strong>Conclusion: </strong>For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"14 4","pages":"236-249"},"PeriodicalIF":2.6,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/17/jap-14-236.PMC9444482.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40358829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信