Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy最新文献

筛选
英文 中文
Dynamic coupling effects of injection on spray and mixture formation in an asymmetrically vibrating combustion engine 非对称振动燃烧发动机中喷射对喷雾和混合气形成的动态耦合效应
Shizhuo Peng, Chenheng Yuan, Jiang Lu
{"title":"Dynamic coupling effects of injection on spray and mixture formation in an asymmetrically vibrating combustion engine","authors":"Shizhuo Peng, Chenheng Yuan, Jiang Lu","doi":"10.1177/09576509241254415","DOIUrl":"https://doi.org/10.1177/09576509241254415","url":null,"abstract":"Enhanced methods of energy conversion present a viable solution for addressing energy load challenges. This study introduces a vibrating combustion engine designed to enhance energy conversion efficiency by harnessing flexible dynamics and variable asymmetric motion. However, the consideration of its unique dynamic effects has emerged as a pivotal challenge in fuel-air mixing and combustion research. This study introduces a fuel spray and mixing simulation method that facilitates the reciprocal exchange of coupling parameters between the combustion and dynamics models. It iterates the simulation outcomes of motion and combustion to predict mixture formation. Subsequently, the method is employed to explore the impact of injection position on fuel spray and mixture formation. Results show that there is an optimum injection position for the operation frequency, and retarding or advancing leads to slow compression and weak gas motion for fuel spray and mixing, although retarded injection provides high in-cylinder gas pressure and temperature. The early injection generally causes long penetration, small droplet diameter, slight impingement, and fast evaporation, unless it is too early. The results further indicate that when IAP = 6 mm, a more uniform mixture can be attained at the beginning of combustion, leading to a thermal efficiency of up to 42.9% for the engine.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"45 16","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140980962","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thermal performance of three concentrating collectors with bifacial PV cells. Part II – parametrical study 采用双面光伏电池的三种聚光集热器的热性能。第二部分--参数研究
M. Lança, João Gomes, Diogo Cabral, S. Hosouli
{"title":"Thermal performance of three concentrating collectors with bifacial PV cells. Part II – parametrical study","authors":"M. Lança, João Gomes, Diogo Cabral, S. Hosouli","doi":"10.1177/09576509241231852","DOIUrl":"https://doi.org/10.1177/09576509241231852","url":null,"abstract":"One of the problems in using PV cells to extract energy from sunlight is the temperature effect on PV cells. As the solar panel is heated, the conversion efficiency of light to electrical energy is diminished. Moreover, successive temperature elevations can cause dilatations in the array of cells which may also contribute to the degradation of the receiver. Some of the operating temperature mitigation approaches may include air-flow ventilation. In this study, data obtained by experimental and numerical simulations of a collector with bifacial PV cells is compared to the expressions found in the literature for the estimation of the heat transfer coefficient. Forced ventilation was applied to the studied collector as it accounts for much better heat dissipation. A new correlation for the estimation of the heat transfer coefficient is developed for such a geometry, for inlet velocities ranging between 3 and 8 m/s. Values of heat transfer coefficient estimated in the present work have been compared with studies of other researchers.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"99 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139794766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thermal performance of three concentrating collectors with bifacial PV cells. Part II – parametrical study 采用双面光伏电池的三种聚光集热器的热性能。第二部分--参数研究
M. Lança, João Gomes, Diogo Cabral, S. Hosouli
{"title":"Thermal performance of three concentrating collectors with bifacial PV cells. Part II – parametrical study","authors":"M. Lança, João Gomes, Diogo Cabral, S. Hosouli","doi":"10.1177/09576509241231852","DOIUrl":"https://doi.org/10.1177/09576509241231852","url":null,"abstract":"One of the problems in using PV cells to extract energy from sunlight is the temperature effect on PV cells. As the solar panel is heated, the conversion efficiency of light to electrical energy is diminished. Moreover, successive temperature elevations can cause dilatations in the array of cells which may also contribute to the degradation of the receiver. Some of the operating temperature mitigation approaches may include air-flow ventilation. In this study, data obtained by experimental and numerical simulations of a collector with bifacial PV cells is compared to the expressions found in the literature for the estimation of the heat transfer coefficient. Forced ventilation was applied to the studied collector as it accounts for much better heat dissipation. A new correlation for the estimation of the heat transfer coefficient is developed for such a geometry, for inlet velocities ranging between 3 and 8 m/s. Values of heat transfer coefficient estimated in the present work have been compared with studies of other researchers.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"52 2","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139854595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design improvement for suction shape in rotary compressor 旋转式压缩机吸气形状的设计改进
Joonhyung Kim, Munseong Kwon, Jaewoo Park, Sunghyuk Park, Woong Hwang
{"title":"Design improvement for suction shape in rotary compressor","authors":"Joonhyung Kim, Munseong Kwon, Jaewoo Park, Sunghyuk Park, Woong Hwang","doi":"10.1177/09576509241232037","DOIUrl":"https://doi.org/10.1177/09576509241232037","url":null,"abstract":"Rotary compressors applied to heating and cooling cycles accounts for a large proportion of the total energy consumed in the system. Therefore, improving compressor efficiency is crucial in order to reduce energy consumption. Design review and improvement efforts have primarily focused on compression and discharge parts with high pressure. However, due to the limitations in design improvements for the compression and discharge parts, enhancements for other components are necessary to further increase compressor efficiency. In this study, the design of the suction part of the rotary compressor was modified using FSI (Fluid-Structure Interact) analysis scheme. In order to improve the design of the suction shape, new suction shape types were devised as alternatives to the existing through type. Both the newly devised C-type and E-type suction shapes presented an increase in cooling capacity due to reduced suction resistance, with the E-type demonstrating greater improvement compared to the C-type. Consequently, a verification of the effect based on the detailed design dimensions was further conducted for the E-type suction shape. The final selected improved model increased the suction flow rate by approximately 2.5% compared to the base model. This indicates that significant improvement for the compressor efficiency can be achieved through modifying designs in parts other than the compression and discharge sections. In addition, a design improvement process was established to analyze internal flow using FSI analysis.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"141 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139859666","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design improvement for suction shape in rotary compressor 旋转式压缩机吸气形状的设计改进
Joonhyung Kim, Munseong Kwon, Jaewoo Park, Sunghyuk Park, Woong Hwang
{"title":"Design improvement for suction shape in rotary compressor","authors":"Joonhyung Kim, Munseong Kwon, Jaewoo Park, Sunghyuk Park, Woong Hwang","doi":"10.1177/09576509241232037","DOIUrl":"https://doi.org/10.1177/09576509241232037","url":null,"abstract":"Rotary compressors applied to heating and cooling cycles accounts for a large proportion of the total energy consumed in the system. Therefore, improving compressor efficiency is crucial in order to reduce energy consumption. Design review and improvement efforts have primarily focused on compression and discharge parts with high pressure. However, due to the limitations in design improvements for the compression and discharge parts, enhancements for other components are necessary to further increase compressor efficiency. In this study, the design of the suction part of the rotary compressor was modified using FSI (Fluid-Structure Interact) analysis scheme. In order to improve the design of the suction shape, new suction shape types were devised as alternatives to the existing through type. Both the newly devised C-type and E-type suction shapes presented an increase in cooling capacity due to reduced suction resistance, with the E-type demonstrating greater improvement compared to the C-type. Consequently, a verification of the effect based on the detailed design dimensions was further conducted for the E-type suction shape. The final selected improved model increased the suction flow rate by approximately 2.5% compared to the base model. This indicates that significant improvement for the compressor efficiency can be achieved through modifying designs in parts other than the compression and discharge sections. In addition, a design improvement process was established to analyze internal flow using FSI analysis.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"221 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139799672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A data-driven polynomial chaos method for uncertainty quantification of a subsonic compressor cascade with stagger angle errors 一种数据驱动的多项式混沌方法,用于对具有错开角误差的亚音速压缩机级联进行不确定性量化
Haohao Wang, Limin Gao, Guang Yang, Baohai Wu
{"title":"A data-driven polynomial chaos method for uncertainty quantification of a subsonic compressor cascade with stagger angle errors","authors":"Haohao Wang, Limin Gao, Guang Yang, Baohai Wu","doi":"10.1177/09576509241231023","DOIUrl":"https://doi.org/10.1177/09576509241231023","url":null,"abstract":"The probability-based uncertainty quantification (UQ) methods require a large amount of sampled data to construct the probability distribution of uncertain input parameters. However, it is a common situation that only limited and scarce sampled data are available in engineering applications due to expensive tests. In the present paper, the Data-Driven Polynomial Chaos (DDPC) method is adopted, which can propagate input uncertainty in the case of scarce sampled data. The calculation accuracy and convergence of the self-developed DDPC method are validated by a nonlinear test function. Subsequently, the DDPC method is applied to investigate the uncertain impact of stagger angle errors on the aerodynamic performance of a subsonic compressor cascade. A family of manufacturing error data of stagger angles was obtained from the real compressor blades. Based on the limited measurement data, the DDPC method combined with Computational Fluid Dynamics (CFD) simulation is employed to quantify the performance impact of the compressor cascade. The results show that the performance dispersion under off-design conditions is more prominent than that under design conditions. The actual aerodynamic performance deviating from the nominal performance is not a small probability event, and the probability of deviating from the nominal loss coefficient and exit flow angle by more than 1% can reach up to 47.6% and 36.8% under high incidence i = 7°. Detailed analysis shows that stagger angle errors have a significant effect on the flow state near the leading edge, resulting in variations in separation bubble size and boundary layer thickness.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"21 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139805035","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A data-driven polynomial chaos method for uncertainty quantification of a subsonic compressor cascade with stagger angle errors 一种数据驱动的多项式混沌方法,用于对具有错开角误差的亚音速压缩机级联进行不确定性量化
Haohao Wang, Limin Gao, Guang Yang, Baohai Wu
{"title":"A data-driven polynomial chaos method for uncertainty quantification of a subsonic compressor cascade with stagger angle errors","authors":"Haohao Wang, Limin Gao, Guang Yang, Baohai Wu","doi":"10.1177/09576509241231023","DOIUrl":"https://doi.org/10.1177/09576509241231023","url":null,"abstract":"The probability-based uncertainty quantification (UQ) methods require a large amount of sampled data to construct the probability distribution of uncertain input parameters. However, it is a common situation that only limited and scarce sampled data are available in engineering applications due to expensive tests. In the present paper, the Data-Driven Polynomial Chaos (DDPC) method is adopted, which can propagate input uncertainty in the case of scarce sampled data. The calculation accuracy and convergence of the self-developed DDPC method are validated by a nonlinear test function. Subsequently, the DDPC method is applied to investigate the uncertain impact of stagger angle errors on the aerodynamic performance of a subsonic compressor cascade. A family of manufacturing error data of stagger angles was obtained from the real compressor blades. Based on the limited measurement data, the DDPC method combined with Computational Fluid Dynamics (CFD) simulation is employed to quantify the performance impact of the compressor cascade. The results show that the performance dispersion under off-design conditions is more prominent than that under design conditions. The actual aerodynamic performance deviating from the nominal performance is not a small probability event, and the probability of deviating from the nominal loss coefficient and exit flow angle by more than 1% can reach up to 47.6% and 36.8% under high incidence i = 7°. Detailed analysis shows that stagger angle errors have a significant effect on the flow state near the leading edge, resulting in variations in separation bubble size and boundary layer thickness.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"58 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139864755","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characteristics of the axial compressor with different stator gaps in compressed air energy storage system 压缩空气储能系统中不同定子间隙轴流压缩机的特性
Pengfei Li, Zhitao Zuo, Xin Zhou, Jingxin Li, Wenbin Guo, Haisheng Chen
{"title":"Characteristics of the axial compressor with different stator gaps in compressed air energy storage system","authors":"Pengfei Li, Zhitao Zuo, Xin Zhou, Jingxin Li, Wenbin Guo, Haisheng Chen","doi":"10.1177/09576509241227290","DOIUrl":"https://doi.org/10.1177/09576509241227290","url":null,"abstract":"The axial compressor in compressed air energy storage (CAES) system needs to operate stably and efficiently within a wide working range. The stator gap plays a critical role in suppressing corner separation and enhancing blade throughflow. The primary objective of this study is to determine the optimal combination of stator gaps to further expand the stable working range of the compressor while ensuring high efficiency. In this study, the flow characteristics of different stator gaps of the five-stage axial compressor in a specific CAES system are researched numerically. Firstly, the impact of different stator gaps on the aerodynamic performance is analyzed. The stator gap effectively broadens the stable working range of the compressor, with the hub gap exhibiting greater potential for expansion compared to the shroud gap. Subsequently, a comparative analysis is conducted on the internal flow of the third stage stator under near-stall conditions. Different gap leakage forms different vortex structures, and the gap leakage can effectively eliminate the accumulation of low-energy fluid in the corner area, optimize the limit streamlines on the blade suction surface and the temperature distribution. The low-velocity area caused by different stator gaps is also different. Finally, energy loss and energy dissipation with different stator gaps are explored. The gap leakage flow results in high energy loss, and different stator gaps exhibit notable differences in distribution of the high energy loss regions. Different types of stator gaps exhibit consistent high energy dissipation areas, which include the leading-edge stagnation area, boundary layer area on blade surface, and wake area. It is important to note that the high energy loss area does not necessarily coincide with the high energy dissipation area. The combined application of two loss evaluation methods contributes to a more comprehensive investigation of the loss distribution characteristics of the compressor.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"16 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139612469","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical study on the three-dimensional flow of water film on the outer surface of the hollow stationary blade 空心固定叶片外表面水膜三维流动的数值研究
Yang Chen, Yujuan Zhao, Xiaodan Zhang, Yanhao Cao, Liangmou Li
{"title":"Numerical study on the three-dimensional flow of water film on the outer surface of the hollow stationary blade","authors":"Yang Chen, Yujuan Zhao, Xiaodan Zhang, Yanhao Cao, Liangmou Li","doi":"10.1177/09576509241227479","DOIUrl":"https://doi.org/10.1177/09576509241227479","url":null,"abstract":"In order to figure out the influence of water film on the performance of the turbomachinery, understand the mechanism of the interaction between the high-speed airflow and the water film in turbomachinery, and provide a reference for the design of the subsequent experiments and hollow stationary blade water removal by heating. The commercial software FLUENT with the Eulerian Wall Films model is used to establish a solution method for simulating the flow of water film on the blade. The accuracy of the solution method is verified by comparing it with the results of the water film thickness experiment on the surface of the plate. The distribution of the water film on the outer surface of the vane as well as the influence of the water film on the mainstream field are numerically studied in the condition of the wet steam mainstream. The results show that the gradient of water film thickness on the pressure surface is relatively gentle and is along the radial direction. The gradient of water film thickness on the suction side is along the axial direction, and the value is larger; There is a V-shaped water film agglomeration area on the suction surface near the trailing edge where the water film thickness is greater than 45.7 μm; The top areas on both the suction side and pressure side produce a local water film agglomeration area with the dual effect of the secondary flow and the centrifugal force of the mainstream; The water film flow on the blade surface has little influence of the steam velocity and the speed of the mainstream. The increase of local pressure on the surface leads to an increase in the pressure of the adjacent mainstream areas.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":" 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139620299","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A numerical study on effect of intra and inter spaced winding configuration on performance of oil forced transformer cooling system 绕组内部和间隔配置对油强制变压器冷却系统性能影响的数值研究
Y. Muralikrishna, Seerapu Siva Satyanarayana Reddy, M. Sahu, M. Mohan Jagadeesh Kumar
{"title":"A numerical study on effect of intra and inter spaced winding configuration on performance of oil forced transformer cooling system","authors":"Y. Muralikrishna, Seerapu Siva Satyanarayana Reddy, M. Sahu, M. Mohan Jagadeesh Kumar","doi":"10.1177/09576509241227299","DOIUrl":"https://doi.org/10.1177/09576509241227299","url":null,"abstract":"The present work aims at investigating, numerically, the heat transfer characteristics of transformer cooling system under forced circulation for three different winding configurations. The purpose of a transformer cooling system is to keep the hot spot temperature within the critical value for a long life of transformer, which increases with enhanced cooling of transformer windings. Thus, two different winding configurations are modeled by providing space within the windings (an intra-space model) and in between the windings (an inter-space model) to improve the fluid-solid interaction. A conventional winding, without spacing, is also modeled for comparative study. A 315 kVA, 3-phase core type transformer is taken as the base model from which the winding and core specifications are obtained analytically. Parameters chosen to measure the influence of winding configuration are local temperature distribution in the windings and core and maximum transformer temperature. Results are obtained for all three models with varying space for various cooling mediums like naphthenic oil, silicon oil, and synthetic ester oil at flow velocities ranging from 0.72 m/s to 2.16 m/s. It is observed that the gap between the windings, interspacing, decreases the secondary winding temperatures, while it increases the core and primary winding temperatures. However, the intra spacing configuration finds a drop in local temperatures at all locations of the transformer windings and core. The enhanced heat dissipation to the cooling agent, with intra spacing winding configuration, reduces the maximum transformer temperature. Contrasting to the above, the inter-space model has an adverse effect on maximum temperature at all widths of space considered. Quantitatively, the space within the transformer reduces the maximum temperature by 5% in comparison with the space between the windings. The increased velocity of the cooling medium, Naphthenic oil, from 0.72 m/s to 2.16 m/s reduces the maximum temperature by 4.5 units. The study made to know the role of cooling medium discloses that the synthetic ester oil shows better performance for reducing temperature values due to its highly viscous nature.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"51 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139531863","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信