压缩空气储能系统中不同定子间隙轴流压缩机的特性

Pengfei Li, Zhitao Zuo, Xin Zhou, Jingxin Li, Wenbin Guo, Haisheng Chen
{"title":"压缩空气储能系统中不同定子间隙轴流压缩机的特性","authors":"Pengfei Li, Zhitao Zuo, Xin Zhou, Jingxin Li, Wenbin Guo, Haisheng Chen","doi":"10.1177/09576509241227290","DOIUrl":null,"url":null,"abstract":"The axial compressor in compressed air energy storage (CAES) system needs to operate stably and efficiently within a wide working range. The stator gap plays a critical role in suppressing corner separation and enhancing blade throughflow. The primary objective of this study is to determine the optimal combination of stator gaps to further expand the stable working range of the compressor while ensuring high efficiency. In this study, the flow characteristics of different stator gaps of the five-stage axial compressor in a specific CAES system are researched numerically. Firstly, the impact of different stator gaps on the aerodynamic performance is analyzed. The stator gap effectively broadens the stable working range of the compressor, with the hub gap exhibiting greater potential for expansion compared to the shroud gap. Subsequently, a comparative analysis is conducted on the internal flow of the third stage stator under near-stall conditions. Different gap leakage forms different vortex structures, and the gap leakage can effectively eliminate the accumulation of low-energy fluid in the corner area, optimize the limit streamlines on the blade suction surface and the temperature distribution. The low-velocity area caused by different stator gaps is also different. Finally, energy loss and energy dissipation with different stator gaps are explored. The gap leakage flow results in high energy loss, and different stator gaps exhibit notable differences in distribution of the high energy loss regions. Different types of stator gaps exhibit consistent high energy dissipation areas, which include the leading-edge stagnation area, boundary layer area on blade surface, and wake area. It is important to note that the high energy loss area does not necessarily coincide with the high energy dissipation area. The combined application of two loss evaluation methods contributes to a more comprehensive investigation of the loss distribution characteristics of the compressor.","PeriodicalId":509769,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"16 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characteristics of the axial compressor with different stator gaps in compressed air energy storage system\",\"authors\":\"Pengfei Li, Zhitao Zuo, Xin Zhou, Jingxin Li, Wenbin Guo, Haisheng Chen\",\"doi\":\"10.1177/09576509241227290\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The axial compressor in compressed air energy storage (CAES) system needs to operate stably and efficiently within a wide working range. The stator gap plays a critical role in suppressing corner separation and enhancing blade throughflow. The primary objective of this study is to determine the optimal combination of stator gaps to further expand the stable working range of the compressor while ensuring high efficiency. In this study, the flow characteristics of different stator gaps of the five-stage axial compressor in a specific CAES system are researched numerically. Firstly, the impact of different stator gaps on the aerodynamic performance is analyzed. The stator gap effectively broadens the stable working range of the compressor, with the hub gap exhibiting greater potential for expansion compared to the shroud gap. Subsequently, a comparative analysis is conducted on the internal flow of the third stage stator under near-stall conditions. Different gap leakage forms different vortex structures, and the gap leakage can effectively eliminate the accumulation of low-energy fluid in the corner area, optimize the limit streamlines on the blade suction surface and the temperature distribution. The low-velocity area caused by different stator gaps is also different. Finally, energy loss and energy dissipation with different stator gaps are explored. The gap leakage flow results in high energy loss, and different stator gaps exhibit notable differences in distribution of the high energy loss regions. Different types of stator gaps exhibit consistent high energy dissipation areas, which include the leading-edge stagnation area, boundary layer area on blade surface, and wake area. It is important to note that the high energy loss area does not necessarily coincide with the high energy dissipation area. The combined application of two loss evaluation methods contributes to a more comprehensive investigation of the loss distribution characteristics of the compressor.\",\"PeriodicalId\":509769,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"volume\":\"16 5\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/09576509241227290\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/09576509241227290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

压缩空气储能(CAES)系统中的轴向压缩机需要在较宽的工作范围内稳定高效地运行。定子间隙在抑制转角分离和增强叶片通流方面起着至关重要的作用。本研究的主要目的是确定定子间隙的最佳组合,以进一步扩大压缩机的稳定工作范围,同时确保高效率。本研究对特定 CAES 系统中五级轴流压缩机不同定子间隙的流动特性进行了数值研究。首先,分析了不同定子间隙对气动性能的影响。定子间隙有效拓宽了压缩机的稳定工作范围,与护罩间隙相比,轮毂间隙表现出更大的扩展潜力。随后,对近失速条件下第三级定子的内部流动进行了对比分析。不同的间隙泄漏形成了不同的涡流结构,间隙泄漏能有效消除角区低能流体的积聚,优化叶片吸入面的极限流线和温度分布。不同定子间隙造成的低速区也不同。最后,探讨了不同定子间隙的能量损失和能量耗散。间隙泄漏流导致高能量损耗,不同的定子间隙在高能量损耗区域的分布上存在明显差异。不同类型的定子间隙表现出一致的高能耗区域,包括前缘停滞区、叶片表面边界层区和尾流区。值得注意的是,高能量损耗区域并不一定与高能量耗散区域一致。两种损耗评估方法的综合应用有助于更全面地研究压缩机的损耗分布特征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics of the axial compressor with different stator gaps in compressed air energy storage system
The axial compressor in compressed air energy storage (CAES) system needs to operate stably and efficiently within a wide working range. The stator gap plays a critical role in suppressing corner separation and enhancing blade throughflow. The primary objective of this study is to determine the optimal combination of stator gaps to further expand the stable working range of the compressor while ensuring high efficiency. In this study, the flow characteristics of different stator gaps of the five-stage axial compressor in a specific CAES system are researched numerically. Firstly, the impact of different stator gaps on the aerodynamic performance is analyzed. The stator gap effectively broadens the stable working range of the compressor, with the hub gap exhibiting greater potential for expansion compared to the shroud gap. Subsequently, a comparative analysis is conducted on the internal flow of the third stage stator under near-stall conditions. Different gap leakage forms different vortex structures, and the gap leakage can effectively eliminate the accumulation of low-energy fluid in the corner area, optimize the limit streamlines on the blade suction surface and the temperature distribution. The low-velocity area caused by different stator gaps is also different. Finally, energy loss and energy dissipation with different stator gaps are explored. The gap leakage flow results in high energy loss, and different stator gaps exhibit notable differences in distribution of the high energy loss regions. Different types of stator gaps exhibit consistent high energy dissipation areas, which include the leading-edge stagnation area, boundary layer area on blade surface, and wake area. It is important to note that the high energy loss area does not necessarily coincide with the high energy dissipation area. The combined application of two loss evaluation methods contributes to a more comprehensive investigation of the loss distribution characteristics of the compressor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信