ChemosensorsPub Date : 2024-07-03DOI: 10.3390/chemosensors12070124
Jael R Neyra Recky, Marjorie Montero-Jimenez, J. Scotto, O. Azzaroni, W. Marmisollé
{"title":"Urea Biosensing through Integration of Urease to the PEDOT-Polyamine Conducting Channels of Organic Electrochemical Transistors: pH-Change-Based Mechanism and Urine Sensing","authors":"Jael R Neyra Recky, Marjorie Montero-Jimenez, J. Scotto, O. Azzaroni, W. Marmisollé","doi":"10.3390/chemosensors12070124","DOIUrl":"https://doi.org/10.3390/chemosensors12070124","url":null,"abstract":"We present the construction of an organic electrochemical transistor (OECT) based on poly(3,4-ethylendioxythiophene, PEDOT) and polyallylamine (PAH) and its evaluation as a bioelectronic platform for urease integration and urea sensing. The OECT channel was fabricated in a one-step procedure using chemical polymerization. Then, urease was immobilized on the surface by electrostatic interaction of the negatively charged enzyme at neutral pH with the positively charged surface of PEDOH-PAH channels. The real-time monitoring of the urease adsorption process was achieved by registering the changes on the drain–source current of the OECT upon continuous scan of the gate potential during enzyme deposition with high sensitivity. On the other hand, integrating urease enabled urea sensing through the transistor response changes resulting from local pH variation as a consequence of enzymatic catalysis. The response of direct enzyme adsorption is compared with layer-by-layer integration using polyethylenimine. Integrating a polyelectrolyte over the adsorbed enzyme resulted in a more stable response, allowing for the sensing of urine even from diluted urine samples. These results demonstrate the potential of integrating enzymes into the active channels of OECTs for the development of biosensors based on local pH changes.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"4 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141683453","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ChemosensorsPub Date : 2024-07-03DOI: 10.3390/chemosensors12070125
Aliya, Shi Liu, Danni Zhang, Yufa Cao, Jinyuan Sun, Shui Jiang, Yuan Liu
{"title":"Research on the Evaluation of Baijiu Flavor Quality Based on Intelligent Sensory Technology Combined with Machine Learning","authors":"Aliya, Shi Liu, Danni Zhang, Yufa Cao, Jinyuan Sun, Shui Jiang, Yuan Liu","doi":"10.3390/chemosensors12070125","DOIUrl":"https://doi.org/10.3390/chemosensors12070125","url":null,"abstract":"Baijiu, one of the world’s six major distilled spirits, has an extremely rich flavor profile, which increases the complexity of its flavor quality evaluation. This study employed an electronic nose (E-nose) and electronic tongue (E-tongue) to detect 42 types of strong-aroma Baijiu. Linear discriminant analysis (LDA) was performed based on the different production origins, alcohol content, and grades. Twelve trained Baijiu evaluators participated in the quantitative descriptive analysis (QDA) of the Baijiu samples. By integrating characteristic values from the intelligent sensory detection data and combining them with the human sensory evaluation results, machine learning was used to establish a multi-submodel-based flavor quality prediction model and classification model for Baijiu. The results showed that different Baijiu samples could be well distinguished, with a prediction model R2 of 0.9994 and classification model accuracy of 100%. This study provides support for the establishment of a flavor quality evaluation system for Baijiu.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"36 S150","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141683354","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ChemosensorsPub Date : 2024-07-03DOI: 10.3390/chemosensors12070126
Rimsha Khan, S. Anjum, Nishat Fatima, Nosheen Farooq, Aqeela Shaheen, Javier Fernandez Garcia, Muhammad Imran Khan, Abdallah Shanableh
{"title":"Development of Electrochemical and Colorimetric Biosensors for Detection of Dopamine","authors":"Rimsha Khan, S. Anjum, Nishat Fatima, Nosheen Farooq, Aqeela Shaheen, Javier Fernandez Garcia, Muhammad Imran Khan, Abdallah Shanableh","doi":"10.3390/chemosensors12070126","DOIUrl":"https://doi.org/10.3390/chemosensors12070126","url":null,"abstract":"Neurotransmitters are essential chemical messengers required for proper brain function, and any changes in their concentrations can lead to neuronal diseases. Therefore, sensitive and selective detection is crucial. This study presents a fast and simple colorimetric method for dopamine detection using three reagent solutions: AgNP and MPA, Ag/Au nanocomposite, and mercaptophenylacetic acid. TEM images showed a narrow distribution of Ag and Au nanoparticles with average sizes of 20 nm and 13 nm, respectively, with gold nanoparticles bound to the edges of silver nanoparticles. A paper-based biosensor was created using manual wax printing for the colorimetric detection of dopamine. Visual detection onsite showed color changes with both the silver nanoparticles and mercaptophenylacetic acid mixture and the silver–gold nanoparticle composite. Electrochemical detection using a glassy carbon electrode modified with 8 mM mercaptophenylacetic acid demonstrated high selectivity and sensitivity towards dopamine, with a peak in the range of 0.7–0.9 V. Interferences were minimized, ensuring high sensitivity and selective detection of dopamine.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":" 21","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141680817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Response Time Dynamics of a Membrane-Based Microfluidic Gas Sensor","authors":"Sreerag Kaaliveetil, Najamuddin Naveed Khaja, Niranjan Haridas Menon, Sagnik Basuray","doi":"10.3390/chemosensors12070127","DOIUrl":"https://doi.org/10.3390/chemosensors12070127","url":null,"abstract":"Practical gas–liquid interfacing is paramount in microfluidic technology, particularly in developing microfluidic gas sensors. We have created an easily replicable membrane-based closed microfluidic platform (MB-MP) to achieve in situ gas–liquid contact for low-resource settings. We have fabricated the MB-MP using readily available materials like double-sided tape or parafilm without conventional soft lithographic techniques. The response characteristics of the MB-MP are studied using CO2 as the model gas and bromothymol blue dye as the sensing material. The dye’s color change, indicative of pH shifts due to CO2 absorption, is captured with a digital microscope and analyzed via the ImageJ software package v1.54g. The response shows saturation and regeneration parts when cycled between CO2 and N2, respectively. Experiments are conducted to investigate the response characteristics and saturation rate under different conditions, including changes in volumetric flow rate, gas stream velocity, and dye solution volume. We observe experimentally that an increase in volumetric flow rate decreases the delay and increases the saturation rate of the response, surpassing the impact of the gas stream’s increased velocity. Furthermore, increasing the dye volume results in an exponential decrease in the saturation rate and an increase in the delay. These insights are essential for optimizing the platform’s response for point-of-use applications.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":" 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141680514","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ChemosensorsPub Date : 2024-07-02DOI: 10.3390/chemosensors12070123
A. Alabbas, R. Slimani, I. El Ouahabi, Abdelkader Zarrouk, Said Lazar, R. Azzallou, Noha F. Shalaby, Sherif A. Abdel-Gawad
{"title":"Environmental Pollution Monitoring via Capillary Zone Electrophoresis and UHPLC Simultaneous Quantification of Some Antipsychotic Drug Residues in Industrial Wastewater Effluents","authors":"A. Alabbas, R. Slimani, I. El Ouahabi, Abdelkader Zarrouk, Said Lazar, R. Azzallou, Noha F. Shalaby, Sherif A. Abdel-Gawad","doi":"10.3390/chemosensors12070123","DOIUrl":"https://doi.org/10.3390/chemosensors12070123","url":null,"abstract":"Monitoring and measuring pharmaceutical pollutants in environmental samples is a vital and complex task due to their potential detrimental effects on human health, even at low levels. Using capillary zone electrophoresis (CZE) and ultra-high-performance liquid chromatography (UHPLC), it was possible to separate and measure three commonly used antipsychotic drugs, chlorpromazine (CPZ), haloperidol (HAL), and risperidone (RIS), in wastewater of the pharmaceutical industry. The technique of solid-phase extraction (SPE) was developed and implemented as a very effective method for preparing samples prior to analysis. The settings of the capillary electrophoretic and chromatographic techniques were adjusted to obtain the most efficient separation profile for the medications being studied. The concentration of all the medicines being investigated ranged from 0.5 to 50 µg/mL. SPE was used to treat real wastewater samples after a thorough validation process that followed the rules set by ICH-Q2B. The developed assays were then effectively employed to identify the tested antipsychotic substances in the real wastewater samples. The provided methodologies may be efficiently utilized to monitor the extent of environmental contamination caused by the investigated pharmaceuticals.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"136 7‐8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141686931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ChemosensorsPub Date : 2024-07-02DOI: 10.3390/chemosensors12070122
L. Andjelković, Slađana Đurđić, D. Stanković, Aleksandar Kremenović, Vladimir B. Pavlović, Dejan A. Jeremić, M. Šuljagić
{"title":"Electrochemical Detection of Acetaminophen in Pharmaceuticals Using Rod-Shaped α-Bi2O3 Prepared via Reverse Co-Precipitation","authors":"L. Andjelković, Slađana Đurđić, D. Stanković, Aleksandar Kremenović, Vladimir B. Pavlović, Dejan A. Jeremić, M. Šuljagić","doi":"10.3390/chemosensors12070122","DOIUrl":"https://doi.org/10.3390/chemosensors12070122","url":null,"abstract":"This study employed a novel synthetic approach involving a modified reverse co-precipitation method utilizing glacial acetic acid to synthesize α-Bi2O3. X-ray powder diffraction and scanning and transmission electron microscopy analyses revealed the formation of a rod-like α-Bi2O3 microstructure. The prepared material was utilized to modify a glassy carbon paste (GCP) electrode for the development of an electrochemical sensor for acetaminophen (APAP) detection using differential pulse voltammetry (DPV). Cyclic voltammetry studies revealed that the GCP@Bi2O3 electrode exhibited enhanced electrochemical properties compared to the bare GCP. The designed GCP@Bi2O3 sensor detected APAP in the linear concentration range from 0.05 to 12.00 µM, with LOQ and LOD of 36 nM and 10 nM, respectively. Additionally, the developed sensor demonstrated sufficient precision, repeatability, and selectivity toward APAP detection. The recovery values between the declared and found APAP content in a pharmaceutical formulation (Caffetin®) displayed the advantageous accuracy, precision, and applicability of the GCP@Bi2O3 sensor and the developed DPV method for real-time APAP detection in pharmaceuticals, with minimal interference from the matrix effect.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"10 36","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141684245","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ChemosensorsPub Date : 2024-07-01DOI: 10.3390/chemosensors12070121
Xuejun Zhou, Pengcheng Ye, Zhiding Huang, Chun Yang, Jiefang Ren, Jin Wang, Shali Tang
{"title":"Selective Determination of 4,4′-Oxydianiline (4,4′-ODA) in Plastic Packaging Using Molecularly Imprinted Polymer Sensor Integrated with Pyrolyzed Copper/Carbon Composite","authors":"Xuejun Zhou, Pengcheng Ye, Zhiding Huang, Chun Yang, Jiefang Ren, Jin Wang, Shali Tang","doi":"10.3390/chemosensors12070121","DOIUrl":"https://doi.org/10.3390/chemosensors12070121","url":null,"abstract":"This study focuses on the synthesis, fabrication, and characterization of a molecularly imprinted polymer (MIP) sensor tailored for the selective determination of 4,4′-oxydianiline (4,4′-ODA) in plastic products. Notably, by integrating the sensor matrix with pyrolyzed copper/carbon material derived from Cu-BTC MOF, a remarkable enhancement in electrochemical performance is achieved. The Cu-BTC material is grown successfully on the surface of carbon nanotubes (CNTs) and subjected to calcination at 800 °C, yielding a CNT/Cu/C composite. This composite exhibits an increased surface area and enhanced electron transfer capability, resulting in an improved current response. To augment the selective detection capability of the modified electrodes for 4,4′-ODA, molecularly imprinted polymers (MIPs) were incorporated onto the composite surface. The modified electrode (CNT-2/Cu/C/MIP/GCE) was synthesized using acrylamide (AM) and methacrylic acid (MAA) as dual-functional monomers with 4,4′-ODA as a template molecule via precipitation polymerization. The differential pulse voltammetric (DPV) current response to 4,4′-ODA showed a favorable linear relationship within the concentration range of (0.15–10 μM,10–100 μM), with a detection limit of 0.05 μM. Moreover, the CNT-2/Cu/C/MIP/GCE sensor demonstrates exceptional sensitivity, specificity, consistency, and durability. Furthermore, this approach has proven effective in detecting 4,4′-ODA in spiked nylon spatula samples, with recovery rates ranging from 86.3% to 103.5%.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"2 11","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141700349","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on the Characterization and Degradation Pattern of Circular RNA Vaccines Using an HPLC Method","authors":"Feiran Cheng, Ji Li, Chaoying Hu, Yu Bai, Jianyang Liu, Dongming Liu, Qian He, Qiuheng Jin, Qunying Mao, Zhenglun Liang, Miao Xu","doi":"10.3390/chemosensors12070120","DOIUrl":"https://doi.org/10.3390/chemosensors12070120","url":null,"abstract":"Circular RNA (circRNA) vaccines have attracted increasing attention due to their stable closed-loop structures and persistent protein expression ability. During the synthesis process, nicked circRNAs with similar molecular weights to those of circRNAs are generated. Analytical techniques based on differences in molecular weight, such as capillary electrophoresis, struggle to distinguish between circRNAs and nicked circRNAs. The characteristic degradation products of circRNAs and their biological activities remain unclear. Therefore, developing methods to identify target circRNAs and non-target components and investigating degradation patterns will be beneficial to gaining an in-depth understanding of the properties and quality control of circRNAs vaccines. The reversed-phase HPLC (RP-HPLC) method was established for identification of target circRNAs, product-related substances, and impurities. Subsequently, we investigated the degradation patterns of circRNAs under thermal acceleration conditions and performed biological analysis of degradation products and linear precursors. Here, RP-HPLC method effectively identified circRNAs and nicked circRNAs. With thermal acceleration, circRNAs exhibited a “circular→nicked circRNAs→degradation products” degradation pattern. Biological analysis revealed that the immunogenicity of degradation products significantly decreased, whereas linear precursors did not possess immunogenicity. Thus, our established RP-HPLC method can be used for purity analysis of circRNA vaccines, which contributes to the quality control of circRNA vaccines and promoting the development of circRNA technology.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"11 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141698143","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ChemosensorsPub Date : 2024-06-14DOI: 10.3390/chemosensors12060111
Arianna Rossi, E. Spagnoli, Alan Visonà, Danial Ahmed, Marco Marzocchi, Vincenzo Guidi, B. Fabbri
{"title":"SO2 Detection over a Wide Range of Concentrations: An Exploration on MOX-Based Gas Sensors","authors":"Arianna Rossi, E. Spagnoli, Alan Visonà, Danial Ahmed, Marco Marzocchi, Vincenzo Guidi, B. Fabbri","doi":"10.3390/chemosensors12060111","DOIUrl":"https://doi.org/10.3390/chemosensors12060111","url":null,"abstract":"Noxious gases such as sulfur-containing compounds can inflict several different adverse effects on human health even when present at extremely low concentrations. The accurate detection of these gases at sub-parts per million levels is imperative, particularly in fields where maintaining optimal air quality is crucial. In this study, we harnessed the capabilities of nanostructured metal-oxide semiconducting materials to detect sulfur dioxide, since they have been extensively explored starting from the last decades for their effectiveness in monitoring toxic gases. We systematically characterized the sensing performance of seven chemoresistive devices. As a result, the SnO2:Au sensor demonstrated to be the most promising candidate for sulfur dioxide detection, owing to its highly sensitivity (0.5–10 ppm), humidity-independent behavior (30 RH% onwards), and selectivity vs. different gases at an operating temperature of 400 °C. This comprehensive investigation facilitates a detailed performance comparison to other devices explored for the SO2 sensing, supporting advancements in gas detection technology for enhanced workplace and environmental safety.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"1 9","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141344572","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"CoNiTe2 Nanomaterials as an Efficient Non-Enzymatic Electrochemical Sensing Platform for Detecting Dopamine","authors":"Zhi-Yuan Wang, Chi-Hung Shen, Shih-Hao Yang, Han-Wei Chang, Yu-Chen Tsai","doi":"10.3390/chemosensors12060110","DOIUrl":"https://doi.org/10.3390/chemosensors12060110","url":null,"abstract":"Dopamine (DA) is an important catecholamine neurotransmitter in the mammalian central nervous system that affects many physiological functions. Hence, a highly sensitive and selective sensing platform is necessary for quantification of DA in the human body. In this study, ternary transition metal tellurides of CoNiTe2 were successfully synthesized using the hydrothermal method. The proposed CoNiTe2 nanomaterials were dispersed well in Nafion to form a well-dispersed suspension and, when dropped on a glassy carbon electrode (GCE) as the working electrode (CoNiTe2/Nafion/GCE) for electrochemical non-enzymatic DA sensing, displayed excellent electrocatalytic activity for dopamine electrooxidation. The morphology and physical/chemical properties of CoNiTe2 nanomaterials were characterized using field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). In order to obtain the best electrochemical response to DA from the fabricated CoNiTe2/Nafion/GCE, the experimental conditions of electrochemical sensing, including the CoNiTe2 loading amounts and pH values of the phosphate buffer solution (PBS), were explored to achieve the best electrochemical sensing performance. Under optimal conditions (2 mg of CoNiTe2 and pH 6.0 of PBS), the fabricated CoNiTe2/Nafion/GCE showed excellent electrocatalytic activity of DA electrooxidation. The CoNiTe2/Nafion/GCE sensing platform demonstrated excellent electrochemical performance owing to the optimal structural and electronic characteristics originating from the synergistic interactions of bimetallic Co and Ni, the low electronegativity of Te atoms, and the unique morphology of the CoNiTe2 nanorod. It exhibited a wide linear range from 0.05 to 100 μM, a high sensitivity of 1.2880 µA µM−1 cm−2, and a low limit of detection of 0.0380 µM, as well as acceptable selectivity for DA sensing. Therefore, the proposed CoNiTe2/Nafion/GCE could be considered a promising electrode material for electrochemical non-enzymatic DA sensing.","PeriodicalId":502217,"journal":{"name":"Chemosensors","volume":"48 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141347315","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}