{"title":"Clinical and Ultrasonographic Features of Papillary Thyroid Carcinoma Located in the Isthmus.","authors":"Jinfang Fan, Wei Zhou, Weiwei Zhan, Lingling Tao, Weiwei Li, Lijun Kuang","doi":"10.1097/RUQ.0000000000000587","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000587","url":null,"abstract":"<p><strong>Abstract: </strong>The aim of this research was to investigate the clinical and ultrasonographic features of papillary thyroid carcinoma (PTC) in the isthmus. A total of 823 patients with 823 PTCs including 133 in the isthmus and 690 in the lateral lobe were included in our study. All patients were confirmed by postoperative pathology. The clinical and ultrasonographic characteristics were retrospectively analyzed and compared. Univariate analysis and multivariate logistic regression analysis were performed. Multifactor analyses showed that PTC in the isthmus was significantly different from PTC originating from the lateral lobe in aspect ratio, microcalcification, extrathyroid extension, lymph node metastases, and lymph node density ( P < 0.05, for all). There were no significant differences in age, sex, tumor size, margin, halo, echogenicity, and homogeneity ( P > 0.05, for all). The results indicated that the sonographic appearances of PTC in the isthmus were relatively atypical; however, it had a higher incidence of extrathyroidal extension, central lymph node metastasis, and a tendency of higher lymph node density. Therefore, more careful ultrasound evaluation should be performed for these nodules.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10061255","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comments from the Editor.","authors":"Theodore J Dubinsky","doi":"10.1097/RUQ.0000000000000641","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000641","url":null,"abstract":"","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9664093","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Emrah Duman, Ahmet Aslan, Ayşenur Buz, Seda Sancak, Mine Aslan, Adnan Kabaalioglu, Ayse Tuba Fersahoglu, Nalan Okuroglu, Ender Onur
{"title":"Interobserver and Intraobserver Reliability in Sonoelastographic Assessment of Thyroid Nodules.","authors":"Emrah Duman, Ahmet Aslan, Ayşenur Buz, Seda Sancak, Mine Aslan, Adnan Kabaalioglu, Ayse Tuba Fersahoglu, Nalan Okuroglu, Ender Onur","doi":"10.1097/RUQ.0000000000000616","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000616","url":null,"abstract":"<p><strong>Background: </strong>Thyroid ultrasonography is the first and perhaps most fundamental step for the radiological distinction of benign and malignant nodules. In this study, 2 radiologists reviewed the sonoelastographic and Doppler images of thyroid nodules and evaluated for the intraobserver and interobserver reliability.</p><p><strong>Purpose: </strong>We aimed to determine confusing nodule identifiers and sonographic features differently defined by observers.</p><p><strong>Methods: </strong>A total of 157 nodules in 91 patients (male/female, 72:19) with ages ranging from 18 to 72 years old were included in the study. Ultrasonographic images and video clips of the nodules were obtained and presented to 2 reviewers unaware of the cytopathology results. Two observers defined the characteristics of the nodules based on previously determined criteria. Then, intraobserver and interobserver correlation coefficients were calculated for each subcategory.</p><p><strong>Results: </strong>In the grayscale ultrasonographic examination, varying degrees from low to high interobserver correlation coefficients were obtained for different subcategories (between κ = 0.359 and κ = 0.821). In color Doppler examination, we obtained medium correlation coefficients ( κ = 0.493 and κ = 0.553). On the other hand, there was a high correlation coefficient in tissue compression elastography ( κ = 0.617 and κ = 0.638).According to our study results, elastographic pattern, shape of the nodule, presence of echogenic foci, and pathological lymph nodes are better predictors to determine the malignant potential of thyroid nodule with higher interobserver correlation. Therefore, these criteria may be used primarily for the evaluation of thyroid nodules. The intraobserver correlation coefficient was higher in the practitioner with longer experience, suggesting the importance of professional practice period on the decision-making process.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10052568","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Intraobserver and Interobserver Consistency Evaluation of Carotid Plaque Volume Measured by Different 3-Dimensional Ultrasound Methods.","authors":"Ling Ren, Lin Yan, Xiang Fei, Yukun Luo","doi":"10.1097/RUQ.0000000000000635","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000635","url":null,"abstract":"<p><strong>Abstract: </strong>This study aims to evaluate the accuracy of the semiautomatic planimetric measurement (SAPM) method and the necessity of manually adjusted boundary measurement in 3-dimensional ultrasound measurement of plaque volume. A total of 50 patients with 82 plaques in the common carotid arteries between December 2020 and March 2021 were included in this study. Two observers measured the 3-dimensional volume of plaque for each patient in 3 different methods (contour tracing method [CTM], SAPM method without manually adjusted boundary [SAPM1], and SAPM method with manually adjusted boundary [SAPM2]). The difference in measurement time between the 3 methods was evaluated by Kruskal-Wallis H test. Intraclass correlation coefficient and 95% confidence interval were used to evaluate the intraobserver and interobserver reliability of the 3 measurement modes. The Bland-Altman analysis was used to assess the agreement, which was expressed as the mean difference with the 95% limits of agreement (LOA). The difference in measurement time between the 3 methods was statistically significant ( P < 0.001). Both observers' intraobserver and interobserver reliability showed well in the 3 methods (all of the intraclass correlation coefficients were >0.75). The mean differences of the plaque volume measurement were 38.17, 26.42, and 11.75 mm 3 , respectively. The agreement between CTM and SAPM2 was the best, and LOA was -57.00 to 80.51. The agreement between SAPM1 and SAPM2 and the agreement between SAPM1 and CTM were similar, and the LOAs were -126.10 to 202.40 and -158.00 to 210.80, respectively. The SAPM method may be recommended to measure plaque volume in clinical practice.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10065564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Clinical Effect of Intrauterine 3-Dimensional Ultrasound on the Function of the Intrauterine Cavity of Puerpera With Intrauterine Adhesions and Safety of Pregnancy.","authors":"Qin Li","doi":"10.1097/RUQ.0000000000000607","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000607","url":null,"abstract":"<p><strong>Abstract: </strong>This study aimed to analyze the diagnostic value of intrauterine 3-dimensional ultrasound and the functional characteristics of the intrauterine cavity for puerpera with intrauterine adhesions, and to explore the safety of pregnancy after treatment. A total of 102 puerperas with intrauterine adhesions were randomly selected, and intrauterine 3-dimensional ultrasound and 2-dimensional ultrasound were performed, respectively. Patients were followed up for 3 years to observe the pregnancy outcome and safety. The overall accuracy of diagnosing intrauterine adhesions through intrauterine 3-dimensional ultrasound was significantly higher than that through 2-dimensional ultrasound, and the accuracy of detecting mild intrauterine adhesions was significantly higher than that through 2-dimensional ultrasound, with statistically significant difference ( P < 0.05). There was no significant difference in the accuracy between intrauterine 3-dimensional and 2-dimensional ultrasound in detecting moderate and severe intrauterine adhesions ( P > 0.05). The difference in missed diagnosis and misdiagnosis rates between the 2 methods was statistically significant ( P < 0.05). All patients received hysteroscopic surgery, and 78 cases (76.47%) were naturally fertilized during postoperative follow-up, including 24 cases of mature delivery, 45 cases of cesarean delivery, and 9 cases of spontaneous abortion. The intrauterine 3-dimensional ultrasound examination of the intrauterine cavity will provide intuitive and comprehensive diagnostic information for a parturient with intrauterine adhesion. Its detection accuracy is higher, and the clinical application is noninvasive and safe, which has certain guiding significance for treatment.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10064500","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ismet Mirac Cakir, Tumay Bekci, Serdar Aslan, Uluhan Eryuruk
{"title":"Comparison of Doppler Ultrasound and Clinical Features of Patients With and Without Femoral Hernia in Lower Extremity Venous Insufficiency Patients.","authors":"Ismet Mirac Cakir, Tumay Bekci, Serdar Aslan, Uluhan Eryuruk","doi":"10.1097/RUQ.0000000000000630","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000630","url":null,"abstract":"<p><strong>Abstract: </strong>In this study, we aim to evaluate Doppler ultrasound (US) and clinical features of patients with and without femoral hernia (FH) in lower extremity chronic venous insufficiency (CVI) patients.We retrospectively analyzed prospectively collected data of 1364 limbs with the CVI suspected. Femoral hernia was detected in 32 of the limbs, and the control group was formed with 32 limbs without FH. All limbs were evaluated with Valsalva maneuver and augmentation method to detect venous reflux in FH group. Venous reflux rates in the Doppler US, venous clinical severity scores (VCSSs), and clinical classes of Clinical-Etiology-Anatomy-Pathophysiology classification were compared statistically in both groups.The mean VCSS was 3.87 ± 0.74 in the FH group and 2.68 ± 0.65 in the control group, which was statistically significant ( P = 0.04). In the more severe clinical classes of Clinical-Etiology-Anatomy-Pathophysiology (C4-6), the number of limbs in the FH group was higher than in the control group (8 and 4, respectively). Doppler US examinations showed venous reflux in 22 of 32 limbs in the FH group and 19 of 32 patients in the control group, and there was a statistically significant difference ( P = 0.029). In the FH group, reflux could be shown only by augmentation method in the vast majority of limbs (16 of 22, 73%).In conclusion, VCSS and reflux rates are higher in limbs with CVI accompanied by FH. In addition, FH may cause false negative results in the evaluation of CVI. The use of augmentation method in limbs with FH can help avoid false negatives.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10062346","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Subchorionic Hematoma Volume Measured by Virtual Organ Computer-Aided Analysis in the Prediction of First-Trimester Pregnancy Outcome.","authors":"Chaoli Xu, Wenrong Wang, Bin Yang, Minmin Zhu","doi":"10.1097/RUQ.0000000000000627","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000627","url":null,"abstract":"<p><strong>Abstract: </strong>This study aimed to assess the association of subchorionic hematoma (SCH) size measured by virtual organ computer-aided analysis (VOCAL) with the first-trimester pregnancy outcome. A total of 139 first-trimester pregnancies from 6 to 12 weeks of gestational age with SCH were included. The circumference, area, and volume of the SCH (Cs, As, and 3DVs) and gestational sac (Cg, Ag, and 3DVg) were automatically calculated by VOCAL. Interobserver agreement was assessed with the intraclass correlation coefficient and Bland-Altman plot. Odds ratios for the clinical and ultrasound characteristics of adverse pregnancy outcomes were estimated by univariate or multivariable logistic regression. There was high interobserver agreement in VOCAL measurements of the SCH and gestational sac (intraclass correlation coefficients, >0.900). By univariate regression analysis, women with adverse pregnancy outcomes were more likely to have vaginal bleeding, a larger As and 3DVs, and higher Cs/Cg, As/Ag, and 3DVs/3DVg ratios (all P < 0.05). In the multivariable regression analysis, a higher 3DVs/3DVg ratio of SCH (odds ratio, 1.034; 95% confidence interval [CI], 1.015-1.053; P = 0.000) and vaginal heavy bleeding had a significant positive relationship with the risk of adverse pregnancy outcomes (odds ratio, 7.846; 95% CI, 1.104-55.737; P = 0.039) remained associated with an increased risk of adverse pregnancy outcomes. With 11.87% as the cutoff, the receiver operating characteristic curve yielded a good predictive performance (area under the curve, 0.713) and high sensitivity (91.18%). The measurements of SCH by VOCAL provide high reliability for estimating the total hematoma burden in first-trimester pregnant patients. A greater volume proportion (3DVs/3DVg) of SCH worsens the pregnancy outcome, and a greater risk of adverse pregnancy outcome also associated with the severity of vaginal bleeding.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10053093","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Maria Zulfiqar, Brendan Calhoun, Anup Shetty, Arora Jyoti, William Middleton
{"title":"Optimization of Patient Positioning for the Sonographic Evaluation of Gallstone Impaction: Analysis of Gallbladder Orientation Based on Computed Tomography.","authors":"Maria Zulfiqar, Brendan Calhoun, Anup Shetty, Arora Jyoti, William Middleton","doi":"10.1097/RUQ.0000000000000620","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000620","url":null,"abstract":"<p><strong>Abstract: </strong>An important sonographic sign of cholecystitis is stone impaction in the gallbladder neck. Demonstration of stone mobility excludes impaction. The purpose of this study is to analyze the orientation of the gallbladder on computed tomography and determine the patient position most likely to facilitate stone mobility. ImageJ processing software was used to determine the x (transverse), y (anterior-posterior), and z (craniocaudal) coordinates for the gallbladder neck and fundus in 544 consecutive computed tomography examinations. The differences in the fundal and neck coordinates were used to determine the likelihood of moving a stone from the neck to the fundus for the left and right lateral decubitus positions ( x coordinates), the prone position ( y coordinates), and the upright position ( z coordinates). The coordinate with the largest difference was considered to predict the position most likely to facilitate stone motion. The difference in position of the fundus and neck was greatest in the y -, z -, and x -axis in 232 (42.6%), 194 (35.7%), and 118 (21.7%) of patients, respectively. For body mass index (BMI) less than 25 kg/m 2 , the difference was greatest in the z -axis (59.8%). For BMI greater than 25 kg/m 2 , the difference was greatest in the y -axis (47.1%). Based on their relative location, the optimal position to facilitate gallstone mobility from the gallbladder neck to fundus was most often prone (especially in high BMI patients), followed by upright (especially in low BMI patients), followed by right lateral decubitus. The left lateral decubitus position was never optimal.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10059749","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Lin Yang, Huie Chen, Feifei Li, Jianmei Liao, Xiangbo Lin
{"title":"The Sonographic Features of Malformation in Fetal Echogenic Bowel and Its Relationship With Chromosome Abnormalities.","authors":"Lin Yang, Huie Chen, Feifei Li, Jianmei Liao, Xiangbo Lin","doi":"10.1097/RUQ.0000000000000609","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000609","url":null,"abstract":"<p><strong>Abstract: </strong>The aims of this study were to analyze the sonographic features and clinical prognosis of fetal echogenic bowel (FEB) and to evaluate the value of FEB in the prediction of fetal chromosomal abnormalities. Eight hundred eighty-two fetuses with FEB were selected. The ultrasonographic features and the chromosomal examination were retrospectively analyzed. Among the 882 FEB, 272 (30.8%) cases had malformation. The most common malformation was cardiovascular malformation (21.6%), followed by urinary malformation (9.0%), craniocerebral malformation (6.8%), and gastrointestinal malformations (5.6%). According to other combined ultrasound abnormalities, the FEBs were divided into 4 groups: isolated FEB group (490 cases), ultrasound soft indicators group (130 cases), single malformation group (117 cases), and multiple malformation group (145 cases). A total of 45 cases (5.1%) were detected with chromosomal abnormalities. Compared with isolated FEB group, the rate of chromosomal abnormality in other 3 groups was significantly higher. Among 490 cases of isolated FEB, 114 cases of isolated FEB group with adverse pregnancy outcomes were selected as the experimental group, and 376 cases of FEB group with good prognosis were selected as the control group. There were significant differences of the location, shape, intensity, and progression between the 2 groups. Multivariate logistic regression analysis showed that central location and progression of FEB were independent risk predictors of poor prognosis. The combined malformation rate is high for FEB fetuses. The fetal systems should be carefully examined when FEB is found in prenatal ultrasound.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10417635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Tuan Vu, Benjamin Shin, Anisha Mittal, Nabeel Sarwani, Kathryn L McGillen
{"title":"Ultrasound Versus Computed Tomography-Guided Native Parenchymal Kidney Biopsies for Hospitalized Patients: Comparison of Clinical Outcomes and Complications.","authors":"Tuan Vu, Benjamin Shin, Anisha Mittal, Nabeel Sarwani, Kathryn L McGillen","doi":"10.1097/RUQ.0000000000000614","DOIUrl":"https://doi.org/10.1097/RUQ.0000000000000614","url":null,"abstract":"<p><strong>Abstract: </strong>Percutaneous native kidney biopsies performed with ultrasound (US) or computed tomography (CT) guidance are important in the workup of medical renal disease, with modality choice often dependent on the performing institution, with various complication rates reported. We compared the complication rates and types of complication of US- versus CT-guided native parenchymal renal biopsy among hospitalized patients. One hundred five consecutive inpatient US- and CT-guided native parenchymal renal biopsies performed by radiologists at a tertiary care academic center between 2006 and 2020 were reviewed retrospectively. Complication rates of biopsy were calculated and compared between the 2 modalities. Comparisons with regard to types of complications were made using the Society of Interventional Radiology grading scale, American Society of Anesthesiologists score, and other clinical data. One hundred five hospitalized adult patients (58 women and 47 men; average age, 53 years) underwent native parenchymal kidney biopsy during the study period. Sixty-three (60%) were CT-guided and 42 (40%) were US-guided. Complication rates between CT- versus US-guided biopsies were 40% versus 19% ( P = 0.03), respectively. There were 7 major and 18 minor complications for CT-guided biopsies and 3 major and 5 minor complications for US-guided biopsies. No statistically significant difference was found in preprocedural American Society of Anesthesiologists Classification score, international normalized ratio, platelet count, or body mass index. Computed tomography-guided native parenchymal kidney biopsy was associated with a higher overall complication rate compared with US-guided biopsy for hospitalized patients. Most complications were minor, which required no treatment or additional follow-up.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":1.3,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10061769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}