{"title":"Shifting behaviour of the threshold for nonlinear current response to high voltage in dielectric oil","authors":"A. Watson","doi":"10.1109/CEIDP.1987.7736561","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736561","url":null,"abstract":"High voltage ramping of hemispherically tipped electrodes in silicone oil results in V-I characteristics in the form of a closed loop. After separation of the displacement current from this the remaining current component is related to the voltage by a nonlinear power law beginning at a threshold value (V<inf>th</inf>/I<inf>th</inf>). This coordinate pair can be shifted by application of a transverse magnetic field and the data indicate that V<inf>th</inf> and I<inf>th</inf> are related according to V<inf>th</inf> — V<inf>b</inf> = K(I<inf>th</inf> — I<inf>b</inf>)<sup>3/2</sup> where K is a constant. The remaining parameters V<inf>a</inf> and I<inf>a</inf> are respectively a negatiave potential and current which appear to indicate that the carriers mediating the current response may be aggregates of charge incorporating a binding energy and an associated current backflow.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131544408","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Time domain spectroscopic measurements of the dielectric properties of heterogeneous materials","authors":"C. D. Ross, K. Campbell, R. E. Barker","doi":"10.1109/CEIDP.1987.7736581","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736581","url":null,"abstract":"In recent years the powerful new techniques of time domain dielectric spectroscopy (TDDS) have revolutionized the field of high frequency dielectric measurements. However, due to the relative newness of the method many questions remain unresolved concerning the applicability of TDDS and the interpretations and limitations of the measurements. In previous and continuing work we have attempted to use TDDS to detect and follow phase changes when a homogeneous single phase liquid transforms into a two phase system consisting of a dispersion of small particles of the new second phase in the remaining original phase.[1] Although the TDDS system provides a good way to detect the phase changes as a function of transition temperature and composition, questions remain about the meaning of the calculated dielectric permittivity (ε' and ε″) of the two phase system. The present investigation was undertaken to obtain experimental results for two phase systems with separately known dielectric properties for the somewhat more interesting case of solid polymer particles in a dielectric fluid.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115545731","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Wintenberg, M. Pace, T. V. Blalock, J. Foust, I. Alexeff
{"title":"Nonuniform field prebreakdown current pulses in negatively stressed n-Hexane","authors":"A. Wintenberg, M. Pace, T. V. Blalock, J. Foust, I. Alexeff","doi":"10.1109/CEIDP.1987.7736540","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736540","url":null,"abstract":"To better understand how breakdown starts in an electrically-stressed liquid, the lowest measureable levels of prebreakdown currents were studied. Knowledge of the factors that influence and enhance prebreakdown activity and an understanding of the mechanisms leading up to breakdown would allow development of liquid dielectrics with higher strength and improved aging properties.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"135 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116718184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transient charge injection from blocking electrodes in transformer oil on the reversal of voltage polarity","authors":"A. Jaksts, U. Gäfvert","doi":"10.1109/CEIDP.1987.7736567","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736567","url":null,"abstract":"In high resistivity oil, the electric field distribution is well described by a model based on charge carrier generation through the dissociation of a species of ion pairs in the liquid bulk. As liquid conductivity increases, the close agreement between model and experimental results weakens. The aim of this work was to determine whether or not there exists a violation of the model assumption that the generated charge carriers are neutralized on arriving at metallic electrodes and to consider the consequences of such a violation. This work has demonstrated that stainless steel electrodes are indeed blocking as charges previously collected on an electrode surface are injected into the liquid on polarity reversal of the applied voltage. Although the model assumption is invalid, the violation cannot totally account for the additional space charge distortion. It is increased liquid resistivity, reflecting the electrostatic cleaning of the oil, that results in a closer fit between model and experiment.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129551592","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High field conduction and space charge in polyvinylidene fluoride","authors":"M. Ieda, T. Mizutani, Y. Suzuoki, T. Yamada","doi":"10.1109/CEIDP.1987.7736566","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736566","url":null,"abstract":"Polyvinylidene fluoride (PVDF) has received considerable attention because of its high dielectric constant and because of its piezo- and pyro-electrie properties [1]. PVDF is also an interesting polymer from the morphological point of view and it has at least two stable crystalline forms, i.e. the α-form (non-polar TGTG molecular conformation) and the β-form (polar planar zig-zag conformation) [2].","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130333852","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of DC electric field distribution in dielectric liquids using a modified Kerr electro-optic technique","authors":"T. Maeno, T. Takada","doi":"10.1109/CEIDP.1987.7736569","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736569","url":null,"abstract":"Potential and electric field distributions in dielectric liquids have been measured during studies on electric conduction and discharge phenomena. The Kerr electro-optic technique is one method of obtaining such measurements. However, it is very difficult to measure electric field distribution in insulating oils, such as transformer oil, because the Kerr constant is small. Recently though, E. F. Kellys2) A. Torne3) and C. Carlsson4) developed a highly sensitive measurement system and were able to obtain electric field distributions in insulating oils.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"337 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133080373","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of temperature on the growth of vented water trees in laboratory molded polyethylene specimens","authors":"A. Bulinski, S. Bamji, R. Densley, C. Au","doi":"10.1109/CEIDP.1987.7736595","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736595","url":null,"abstract":"The deleterious effect of vented water trees on the insulation of polymeric high voltage cables has been known for over fifteen years. Extensive studies of this phenomenon in different laboratories around the world have produced a very large volume of data some of which are contradictory. A prime example is the reported effects of temperature on water tree initiation and growth. Although many researchers have found treeing and related processes to speed up with temperature there are a number of studies which show the opposite [1]. Understanding the effect of temperature is essential as temperature is one of the major stresses on the insulation during service.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130202990","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"AC versus DC mechanisms for conduction current decay","authors":"W. Stanaland","doi":"10.1109/CEIDP.1987.7736568","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736568","url":null,"abstract":"Decaying conduction current amplitude with time when dc voltages are applied to liquids or solid have been reported for over a hundred years. One of the first reports was by Maxwell{1} for dc voltages applied to glass. Since then many researchers such as Krasucki{2}, House, Felici and others have examined electrode effects when dc voltages are applied to electrodes immersed in liquids. Yet very little has been reported about conduction current amplitude decay whenever ac voltages are applied to parallel plate electrods immersed in a dielectric liquid which contains impurity particles. This paper uses measured current and electric field data, drift theory, Maxwell's rule for particle charge modified for semiconductors, coagulation of conduction particles and conservation of particle volume to show that conduction current amplitude may decrease with time when an ac voltage is applied provided the net particle charge per unit volume decreases with particle size.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"97 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126983646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"DC cable insulation conductivity as a function of temperature, polarity changes and time","authors":"M. Henriksen, E. Larsen, H. Johannesson","doi":"10.1109/CEIDP.1987.7736586","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736586","url":null,"abstract":"A detailed description of our revised method of preparing PE and XLPE samples to be used for the investigation of the fundamental parameters of these two materials will be presented. The latest findings regarding the long term conductivity of the specimens under high and constant electrical field, when temperature was varied in a cycling (24h) manner from room temperature (40° C) to about the maximum operating temperature of XLPE (85 °C) and kept constant for fixed periods at the two temperature levels, will also be reported. The temperature variations, positive and negative temperature gradients, and the polarity changes have marked influences on the conductivity of both types of cable insulation, but little absolute differences between PE and XLPE have been found.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"263 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126053160","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Elucidation of the chemical reaction in the crosslinked poltethtlene insulation exposed to high temperature","authors":"H. Kato, I. Miyashita","doi":"10.1109/CEIDP.1987.7736588","DOIUrl":"https://doi.org/10.1109/CEIDP.1987.7736588","url":null,"abstract":"Insulation of crosslinked polyethylene (ILPE) insulated power cables may be occasionally exposed to nigh temperature above 150°C for relatively short period in the course of cable jointing procedure. The authors have reported that the cumyl alcohol produced as a decomposition product from crosslinking agent (dicumyl peroxide, DCP) might be dehydrated to leave water in the XLPE insulation during the procedure (1). The water thus formed may decrease cable performance with the formation of voids in XLPE insulation.","PeriodicalId":433367,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129677438","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}