{"title":"Implanted sensors to measure pH and other analytes with x-ray readout (Conference Presentation)","authors":"J. Anker","doi":"10.1117/12.2530034","DOIUrl":"https://doi.org/10.1117/12.2530034","url":null,"abstract":"X-ray imaging is well-suited for deep tissue analysis, and is routinely used in medical diagnosis, but is normally blind to local biochemical signals. Here we describe simple passive implantable sensors that can report local chemical concentrations (e.g. pH), which are important for detecting and studying infection and other diseases or conditions. The sensors contain hydrogels with chemically-responsive swelling; the chemical concentration is determined using an X-ray to measure the position of radio-opaque markers in embedded in the hydrogel. For example, to measure local pH near the surface of an orthopedic plate, a sensor containing a polyacrylic acid hydrogel was attached to the plate. The hydrogel displayed a pH-dependent swelling, expanding approximately and moving an embedded radio-opaque tungsten marker. The sensor was calibrated in standard pH buffers and tested during bacterial growth in culture. Its response was negligibly affected by changes in temperature and sodium chloride concentration within the normal physiological range. Radiographic measurements were also performed in cadaveric tissue with the sensor attached to an implanted orthopedic plate fixed to a tibia. Pin position readings varied by 100 µm between observers surveying the same radiographs, corresponding to 0.065 pH unit precision in the range pH 4-8 (1.5 mm/pH unit). We are expanding the approach to other analytes (infection markers and mechanical strain sensors to track bone heaing), miniaturized injectable sensors, and imaging at multiple locations. \u0000Acknowledgement: This research was supported by the following grants: NSF CHE1255535, NIH NIGMS 5P20GM103444-07, NIH 1R21EB019709-01A1, and NIH NIAMS R01 AR070305-01.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123845711","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High-sensitivity quantitative x-ray phase-contrast computed tomography for biomedical applications (Conference Presentation)","authors":"J. Herzen","doi":"10.1117/12.2531941","DOIUrl":"https://doi.org/10.1117/12.2531941","url":null,"abstract":"Over the last two decades, phase-contrast X-ray imaging has been demonstrated to provide superior soft-tissue contrast in comparison to conventional attenuation-based X-ray imaging. However, visualizing biomedical soft tissue at high spatial resolution and high image quality still has been limited to brilliant synchrotron radiation sources with its very limited access. Thus, the possibility to perform high-sensitivity X-ray phase-contrast computed tomography with laboratory setups is of great interest for a broad range of high-resolution biomedical applications. We designed and built a grating-based setup using a standard rotating-anode X-ray source and reaching comparable angular sensitivity as synchrotron-based setups. Here, we will demonstrate the performance of our instrument by highlighting the recent results on quantitative biomedical soft-tissue analysis of different human diseases.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127734958","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"In situ position-resolved x-ray diffraction of an intact Roman-era Egyptian mummy guided by computed tomography","authors":"S. Stock, M. Stock, J. Almer","doi":"10.1117/12.2530925","DOIUrl":"https://doi.org/10.1117/12.2530925","url":null,"abstract":"Contrast in Computed Tomography (CT) most often relies on absorption differences, and reconstructions give absorptivity of each volume element (voxel) but not the material’s identity. This paper describes the first use of in situ position-resolved x-ray diffraction to identify different contents (see below) within an intact mummy. Hawara Portrait Mummy No. 4 (HPM4) was first imaged with a clinical CT scanner, and this 3D “roadmap” guided diffraction mapping at beamline 1-ID of the Advanced Photon Source. Only 24 hrs were available, and the CT data allowed mapping of only the volumes of interest. The long beam path through the mummy was a major complication solved by collecting each diffraction pattern at two detector-mummy separations. Accuracy in diffracting volume positions was 1-2 mm, and precision sufficed for diffraction identification of the materials. Diffraction patterns were collected from the mineralized tissues within the five year old child’s mummy (HPM4), specifically the skull, cervical vertebrae, femora and teeth. Patterns from the femorum lateral and medial sides (and the skull’s left and right sides) could be analyzed separately. Lattice parameters and crystallite sizes of the bones’ mineral phase were comparable with those from modern bone. Within the wrappings, wires were located by diffraction and identified as a modern dual phase steel, probably introduced during earlier conservation. Highly absorbing, millimeter-sized inclusions were identified as calcite. The position of these and other features were found at the positions indicated by the CT scans, and the limitations of the diffraction approach compared to absorption CT are discussed.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"165 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116136335","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Momose, K. Vegso, H. Takano, Yanlin Wu, Koh Hashimoto, M. Hoshino
{"title":"Four-dimensional pink-beam x-ray phase tomography for studying laser processing","authors":"A. Momose, K. Vegso, H. Takano, Yanlin Wu, Koh Hashimoto, M. Hoshino","doi":"10.1117/12.2528669","DOIUrl":"https://doi.org/10.1117/12.2528669","url":null,"abstract":"X-ray phase tomography by Talbot interferometry functions with X-rays of a broad energy band, and a pink- beam extracted by a multilayer mirror from white synchrotron radiation is used for four-dimensional X-ray phase tomography, which was developed at BL28B2, SPring-8, Japan. Polymer samples under infrared laser irradiation were observed as model experiments of laser processing. In this paper, laser ablation for a carbon-fiber reinforced polymer (CFRP) sample is reported. Thanks to the fact that the fibrous structure generates visibility (or dark-field) contrast, four-dimensional tomogram from the visibility reduction is presented. A technical effort to improve the temporal resolution from 1 s to 160 ms is also described.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114245342","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Use of liquid MetalJet sources in applications of biomedical imaging and computed tomography (Conference Presentation)","authors":"A. Adibhatla, P. Takman, D. Larsson, U. Lundström","doi":"10.1117/12.2528876","DOIUrl":"https://doi.org/10.1117/12.2528876","url":null,"abstract":"","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"103 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124749391","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Regression-based sinogram replacement for CT metal artifact reduction","authors":"Seemeen Karimi, H. Martz","doi":"10.1117/12.2531682","DOIUrl":"https://doi.org/10.1117/12.2531682","url":null,"abstract":"","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133326323","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
I. Zenyuk, A. Shum, E. Leonard, V. Andrade, D. Parkinson, Xianghui Xiao
{"title":"Operando multimodal x-ray tomography of transport in electrochemical energy-conversion and storage devices (Conference Presentation)","authors":"I. Zenyuk, A. Shum, E. Leonard, V. Andrade, D. Parkinson, Xianghui Xiao","doi":"10.1117/12.2530007","DOIUrl":"https://doi.org/10.1117/12.2530007","url":null,"abstract":"X-ray computed tomography (CT) is a promising technique for three-dimensional imaging of batteries, electrolyzers and fuel cells. Operando techniques rely significantly on reactor design, where the operando cell should approximate the actual device. Furthermore, nano- and micro-scale hierarchical materials are used to convert or store electrochemical energy. Imaging with the single scale or synchrotron beamline provides only sliver of information needed. Carbon and ionomer materials that are used as bulk materials in the electrochemical devices are soft and phase-contrast imaging is required. \u0000We present our micro- and nano-X-ray CT reactors designs for polymer electrolyte fuel cells (PEFCs), electrolyzers, and micro X-ray CT operando pouch cell for battery. With the PEFC hardware we control temperature, relative humidity, pressure of gasses, as well as current density. By imaging the PEFCs at various current densities we are able to observe physical phenomena of membrane swelling with relative humidity increase and formation and removal of liquid water from the cell. With nano X-ray CT we are able to combine morphology with x-ray absorption near edge structure (XANES) to elucidate the oxidation state of the catalyst within the active porous layer. Using phase-contrast we are able to distinguish between liquid water and carbon phases. For electrolyzers, understanding formation and removal of oxygen bubbles, which is sub-second transport phenomena is critical. We combine X-ray CT with sub-second X-ray radiography to understand this transient process. For the batteries, we have developed a high throughput pouch cell design for x-ray CT imaging featuring 1 cm diameter active area.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"103 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133415222","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis algorithms for simultaneous neutron and x-ray tomography datasets from the NIST NeXT system (Conference Presentation)","authors":"J. LaManna, D. Hussey, E. Baltic, D. Jacobson","doi":"10.1117/12.2529596","DOIUrl":"https://doi.org/10.1117/12.2529596","url":null,"abstract":"The NIST Neutron and X-ray Tomography (NeXT) system provides simultaneous, complementary, multimodal information for the characterization of materials. Neutrons and X-rays yield complementary, non-destructive views of a complex system due to the contrast differences that arise from the differences in interaction with matter for the two modes. The NeXT system orients a 90 keV microfocus X-ray tube orthogonally to the thermal neutron beam. This enables truly simultaneous capture of the two modalities, thus it is possible to perform multimodal tomography of dynamic or stochastic samples while penetrating through sample environment equipment such as pressure and flow vessels. NIST has developed and continues to update distributable software for reconstructing and analyzing the multimodal datasets. Tomographic reconstruction offers multiple CPU and GPU based algorithms for parallel and cone beam geometries. Additional analysis routines perform volume registration and region of interest segmentation of the bivariate histogram that leverages the contrast differences between the two modalities. This talk will give an overview of the NeXT system, the algorithm developments underway and provide multiple research applications using the system.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131552037","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An example of in situ ductile damage analysis by tracking algorithm","authors":"C. L. Bourlot, Amin Azman, J. Adrien, E. Maire","doi":"10.1117/12.2531357","DOIUrl":"https://doi.org/10.1117/12.2531357","url":null,"abstract":"Damage evolution in ductile metals is characterized by the nucleation, growth and coalescence of small internal voids. Many laws and studies have been developed to understand and predict damage. Numerical modeling, based on full field microstructure acquisition have proven also to be quite efficient. Real microstructure input are of utmost importance as some studies have shown that the deviation from the average behavior for voids growth can be huge and therefore allows a single cavity to drive the damage behavior and lead to failure. We develop the dedicated tool to analyze individually voids during in situ test and use results as input for numerical simulations.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132347958","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Quadratic neural networks for CT metal artifact reduction","authors":"Fenglei Fan, Hongming Shan, L. Gjesteby, Ge Wang","doi":"10.1117/12.2530363","DOIUrl":"https://doi.org/10.1117/12.2530363","url":null,"abstract":"Recently, deep learning has become the mainstream method in multiple fields of artificial intelligence / machine learning (AI/ML) applications, including medical imaging. Encouraged by the neural diversity in the human body, our group proposed to replace the inner product in the current artificial neuron with a quadratic operation on inputs (called quadratic neuron) for deep learning. Since the representation capability at the cellular level is enhanced by the quadratic neuron, we are motivated to build network architectures and evaluate the potential of quadratic neurons towards “quadratic deep learning”. Along this direction, our previous theoretical studies have shown advantages of quadratic neurons and quadratic networks in terms of efficiency and representation. In this paper, we prototype a quadratic residual neural network (Q-ResNet) by incorporating quadratic neurons into a convolutional residual structure, and then deploy it for CT metal artifact reduction. Also, we report our experiments on a simulated dataset to show that Q-ResNet performs better than the classic NMAR algorithm.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116249543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}