Developments in X-Ray Tomography XII最新文献

筛选
英文 中文
MARS pre-clinical imaging: the benefits of small pixels and good energy data MARS临床前成像:小像素和良好能量数据的好处
Developments in X-Ray Tomography XII Pub Date : 2019-09-27 DOI: 10.1117/12.2532367
P. Butler, Jennifer A. Clark, P. Carbonez, Shishir Dahal, S. Bell, M. Walsh, Chiara Lowe, M. Wijesooriya, R. Doesburg, Sam Gurney, S. Gieseg, N. Ghodsian, A. Butler, L. V. Broeke, P. Kanithi, Fatemeh Asghariomabad, A. Chernoglazov, Y. Sayous, J. Damet, Rayhan Uddin, N. Ruiter, H. Prebble, J. Crighton, N. Schleich, C. Chambers, V. Vivek, M. Moghiseh, Marzieh Amjomrouz, David Palmer, J. Atlas, R. Panta, P. Renaud, B. P. Goulter, W. R. Younger, A. Raja, Emily Searle, J. Healy, E. Walker, E. Marfo, S. Bheesette, Jereena S. Sheeja, Steven D Alexander, Sikiru A Adebileje, Maya R. Amma, T. Kirkbride, S. Lansley, Neryda Duncan, A. Atharifard, V. Mandalika, Aysouda Matanaghi, Benjamin Bamford
{"title":"MARS pre-clinical imaging: the benefits of small pixels and good energy data","authors":"P. Butler, Jennifer A. Clark, P. Carbonez, Shishir Dahal, S. Bell, M. Walsh, Chiara Lowe, M. Wijesooriya, R. Doesburg, Sam Gurney, S. Gieseg, N. Ghodsian, A. Butler, L. V. Broeke, P. Kanithi, Fatemeh Asghariomabad, A. Chernoglazov, Y. Sayous, J. Damet, Rayhan Uddin, N. Ruiter, H. Prebble, J. Crighton, N. Schleich, C. Chambers, V. Vivek, M. Moghiseh, Marzieh Amjomrouz, David Palmer, J. Atlas, R. Panta, P. Renaud, B. P. Goulter, W. R. Younger, A. Raja, Emily Searle, J. Healy, E. Walker, E. Marfo, S. Bheesette, Jereena S. Sheeja, Steven D Alexander, Sikiru A Adebileje, Maya R. Amma, T. Kirkbride, S. Lansley, Neryda Duncan, A. Atharifard, V. Mandalika, Aysouda Matanaghi, Benjamin Bamford","doi":"10.1117/12.2532367","DOIUrl":"https://doi.org/10.1117/12.2532367","url":null,"abstract":"Images from MARS spectral CT scanners show that there is much diagnostic value from using small pixels and good energy data. MARS scanners use energy-resolving photon-counting CZT Medipix3RX detectors that measure the energy of photons on a five-point scale and with a spatial resolution of 110 microns. The energy information gives good material discrimination and quantification. The 3D reconstruction gives a voxel size of 70 microns. We present images of pre-clinical specimens, including excised atheroma, bone and joint samples, and nanoparticle contrast agents along with images from living humans. Images of excised human plaque tissue show the location and extent of lipid and calcium deposition within the artery wall. The presence of intraplaque haemorrhage, where the blood leaks into the artery wall following a rupture, has also been visualised through the detection of iron. Several clinically important bone and joint problems have been investigated including: site-specific bone mineral density, bone-metal interfaces (spectral CT reduces metal artefacts), cartilage health using ionic contrast media, gout and pseudogout crystals, and microfracture assessment using nanoparticles. Metallic nanoparticles have been investigated as a cellular marker visible in MARS images. Cell lines of different cancer types (Raji and SK-BR3) were incubated with monoclonal antibody-functionalised AuNPs (Herceptin and Rituximab). We identified and quantified the labelled AuNPs demonstrating that Herceptin-functionalised AuNPs bound to SK-BR3 breast cancer cells but not to the Raji lymphoma cells. In vivo human images show the bone microstructure. Fat, water, and calcium concentrations are quantifiable.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"139 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114705000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Evaluation of different heavy-metal stains and embedding media for phase contrast tomography of neuronal tissue 不同重金属染色剂和包埋介质对神经元组织相衬断层扫描的评价
Developments in X-Ray Tomography XII Pub Date : 2019-09-27 DOI: 10.1117/12.2528432
M. Eckermann, M. Töpperwien, T. Ruhwedel, W. Möbius, T. Salditt
{"title":"Evaluation of different heavy-metal stains and embedding media for phase contrast tomography of neuronal tissue","authors":"M. Eckermann, M. Töpperwien, T. Ruhwedel, W. Möbius, T. Salditt","doi":"10.1117/12.2528432","DOIUrl":"https://doi.org/10.1117/12.2528432","url":null,"abstract":"","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125946520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Observations on the scaling relationship between bony labyrinth, skull size and body mass in ruminants 反刍动物骨迷路、颅骨大小和体重的比例关系观察
Developments in X-Ray Tomography XII Pub Date : 2019-09-24 DOI: 10.1117/12.2530702
L. Costeur, B. Mennecart, B. Müller, G. Schulz
{"title":"Observations on the scaling relationship between bony labyrinth, skull size and body mass in ruminants","authors":"L. Costeur, B. Mennecart, B. Müller, G. Schulz","doi":"10.1117/12.2530702","DOIUrl":"https://doi.org/10.1117/12.2530702","url":null,"abstract":"The bony labyrinth is the bony capsule of the inner ear, which is the center of hearing and balance in the skull of vertebrates. In mammals this osseous structure ossifies early in the development being fully formed largely before birth. This means that it does not grow after full ossification while the animal continues to grow until full adult size well after birth. At the level of an individual, the bony labyrinth thus shows a negative ontogenetic allometric relationship with the surrounding skull and with the animal’s body mass. At the evolutionary level, between species, such a negative allometry has already been evidenced for the middle ear, a component of the ear region made of three tiny bones, the ossicles, in contact with the inner ear. Herein, we test the allometric relationship between the bony labyrinth and skull length as well as body mass on a large sample in the ruminant clade (Mammalia, Ruminantia) using micro computed tomography as the imaging method of choice. We find a strong negative allometry paralleling the ontogentic allometry described earlier. This evolutionary relationship related to the timing of ossification of the bony labyrinth is probably critical in explaining the large hearing frequency range of mammals as well as their particular ecological adaptations.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"180 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132283878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Evaluation of metal nanoparticle- and plastic resin-based x-ray contrast agents for kidney capillary imaging 金属纳米颗粒和塑料树脂基肾毛细血管造影x线造影剂的评价
Developments in X-Ray Tomography XII Pub Date : 2019-09-19 DOI: 10.1117/12.2529414
W. Kuo, G. Schulz, B. Müller, V. Kurtcuoglu
{"title":"Evaluation of metal nanoparticle- and plastic resin-based x-ray contrast agents for kidney capillary imaging","authors":"W. Kuo, G. Schulz, B. Müller, V. Kurtcuoglu","doi":"10.1117/12.2529414","DOIUrl":"https://doi.org/10.1117/12.2529414","url":null,"abstract":"Injection of radiopaque substances into the vasculature followed by post mortem high resolution X-ray μCT imaging currently remains the primary means for capillary imaging in soft tissue. Commercial contrast agents for in vivo applications are, however, typically small molecular compounds that can easily diffuse across the blood vessel walls, which makes them unsuitable for ex vivo high resolution X-ray μCT imaging. We evaluated the suitability for kidney capillary imaging of the nanoparticle-based blood pool contrast agents Aurovist 15 nm and ExiTron nano 12000, along with the vascular casting resin μAngiofil, by post mortem imaging of whole mouse kidneys with 4-5 μm voxel size using the laboratory source μCT system Nanotom m. Based on the results, we identified specific obstacles to reliable capillary filling in the kidney, which will aid in the development of next-generation X-ray contrast agents and protocols.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116574648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A compact light source for x-ray tomography applications across length scales (Conference Presentation) 用于跨长度尺度x射线断层成像应用的紧凑型光源(会议报告)
Developments in X-Ray Tomography XII Pub Date : 2019-09-17 DOI: 10.1117/12.2527374
B. Hornberger, J. Kasahara, M. Gifford
{"title":"A compact light source for x-ray tomography applications across length scales (Conference Presentation)","authors":"B. Hornberger, J. Kasahara, M. Gifford","doi":"10.1117/12.2527374","DOIUrl":"https://doi.org/10.1117/12.2527374","url":null,"abstract":"","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128377090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
X-ray tomography of internal components of the NBS-1 photo-neutron source (Conference Presentation) NBS-1光中子源内部元件的x射线层析成像(会议报告)
Developments in X-Ray Tomography XII Pub Date : 2019-09-17 DOI: 10.1117/12.2529502
J. LaManna, H. Mumm, M. Dewey
{"title":"X-ray tomography of internal components of the NBS-1 photo-neutron source (Conference Presentation)","authors":"J. LaManna, H. Mumm, M. Dewey","doi":"10.1117/12.2529502","DOIUrl":"https://doi.org/10.1117/12.2529502","url":null,"abstract":"The NBS-1 photo-neutron source is the primary standard for neutron calibrations in the United States of America. The source is constructed from 1 g of radium in a RaBr2 salt contained in a Pt-Ir capsule located in the geometric center of a 4 cm beryllium sphere. Since the source was fabricated in 1949, it is desirable to determine the integrity of the capsule and current geometry of the radium salt. Several challenges are presented in inspecting the source such as the high-Z materials used for the capsule which make X-ray tomography challenging with lower keV generators and the radioactive material which creates an intense neutron and gamma radiation fields. The radiation emitted from the source makes it impractical to move the source to a capable imaging facility and makes it difficult to work with as it is not possible to handle directly. To overcome these issues and allow for a feasibility study, a dummy source has been constructed using PbBr2 powder. This talk will provide background on the dummy source and the results of the feasibility study to determine if it possible to relocate a current X-ray system to the neutron calibration facility to inspect the NBS-1 source.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128557195","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Combined fluorescence and diffraction tomography of bone at <140-nm resolution (Conference Presentation) <140纳米分辨率的骨联合荧光和衍射断层扫描(会议报告)
Developments in X-Ray Tomography XII Pub Date : 2019-09-17 DOI: 10.1117/12.2531798
Jonas Palle, N. K. Wittig, T. Grünewald, A. Kubec, M. Rosenthal, H. Birkedal
{"title":"Combined fluorescence and diffraction tomography of bone at <140-nm resolution (Conference Presentation)","authors":"Jonas Palle, N. K. Wittig, T. Grünewald, A. Kubec, M. Rosenthal, H. Birkedal","doi":"10.1117/12.2531798","DOIUrl":"https://doi.org/10.1117/12.2531798","url":null,"abstract":"Composite materials, both biominerals such as bone or shells but also increasingly synthetic materials, often have a complex hierarchical 3D structure ranging over several length scales. To fully understand the structure of such materials, a method for probing the nanoscale structure in 3D is needed. Materials such as bone are particularly challenging due to their complex composition and hierarchical structure. Recent developments in synchrotron x-ray focusing optics have paved the way for smaller x-ray beams with high brilliance. Herein, we present how we probe the 3D elemental distribution and crystallographic properties of human bone using combined fluorescence and diffraction tomography (F-CT and XRD-CT) with a 50 nm pencil X-ray beam. The 2.6×3.1 µm2 cross section sample was a FIB-cut rod of human iliac crest bone. We recorded 2D diffraction patterns and fluorescence spectra for each point in a 50 nm raster scan grid pattern from 92 projection angles covering 0-182°. This allowed us to reconstruct tomographically both x-ray diffraction patterns and the elemental composition in a ∼5×5×3 µm3 volume encompassing the sample. We show that tomographic reconstruction of x-ray diffraction and fluorescence information is possible at <140 nm spatial resolution estimated from features in reconstructed images. Thereby it is possible to probe crystalline structure and elemental composition in 3D at length scales an order of magnitude smaller than hitherto available. This allows studying a very broad range of materials from biominerals to energy materials in more detail than ever before.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114169173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The new x-ray laboratory: enabling access to structure, composition, and morphology through laboratory x-ray instrumentation (Conference Presentation) 新的x射线实验室:通过实验室x射线仪器获得结构、成分和形态(会议报告)
Developments in X-Ray Tomography XII Pub Date : 2019-09-17 DOI: 10.1117/12.2528840
J. Gelb, D. Vine, R. Qiao, Xiaolin Yang, S. Seshadri, Benjamin Stripe, S. Lewis, S. H. Lau, W. Yun
{"title":"The new x-ray laboratory: enabling access to structure, composition, and morphology through laboratory x-ray instrumentation (Conference Presentation)","authors":"J. Gelb, D. Vine, R. Qiao, Xiaolin Yang, S. Seshadri, Benjamin Stripe, S. Lewis, S. H. Lau, W. Yun","doi":"10.1117/12.2528840","DOIUrl":"https://doi.org/10.1117/12.2528840","url":null,"abstract":"","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131107733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
High-throughput x-ray imaging, microscopy, and tomography for biological applications on EMBL beamline P14 at PETRA III (Conference Presentation) 高通量x射线成像、显微镜和断层扫描在EMBL波束线P14上的生物应用
Developments in X-Ray Tomography XII Pub Date : 2019-09-17 DOI: 10.1117/12.2534688
M. Polikarpov, G. Bourenkov, A. Snigirev, T. Schneider
{"title":"High-throughput x-ray imaging, microscopy, and tomography for biological applications on EMBL beamline P14 at PETRA III (Conference Presentation)","authors":"M. Polikarpov, G. Bourenkov, A. Snigirev, T. Schneider","doi":"10.1117/12.2534688","DOIUrl":"https://doi.org/10.1117/12.2534688","url":null,"abstract":"EMBL Hamburg operates the P14 beamline at the high-brilliance PETRA III storage ring at DESY. Delivering hard X-rays (6 – 30 keV), P14 is very versatile: shape, size and intensity of the X-ray beam are easily tunable by using both reflective and refractive optical elements. Sample stage and detecting systems are state-of-the-art including a high-precision vertical goniometer, a robotized sample changer and a DECTRIS EIGER 16M detector. These features enable crystallography of large macromolecular complexes, serial crystallography, time-resolved and in-situ diffraction data collection. \u0000Exploiting the flexibility of the beamline optics, we are investigating new methods and techniques to look into samples of interest via full-field phase-contrast X-ray imaging [1] and microscopy. Unlike conventional absorption X-ray imaging, phase contrast makes interfaces and density gradients clearly visible in a biological sample. To achieve higher resolution and to see fine structure, we also implement X-ray refractive lenses [2] as an objective in the microscopy mode. This approach allows us to magnify details of the sample up to 15 times prior to the optical detection of X-rays that carry the phase-contrast information from the interaction with sample. With the current setup, a sub-100nm resolution can be achieved. High-precision rotation of the sample stage at P14 also allows to perform X-ray tomography. Due to the use of high-energy X-rays for the imaging process, materials and tissues with thicknesses in the mm-range can be penetrated. \u0000The described setup apply phase-contrast imaging techniques for full-field visualization and fast X-ray tomography of crystals in optically opaque mesophase with sub-micron resolution at low dose (Polikarpov et al., 2019, in press). With the help of the method, it is possible to visualize crystal boundaries and their local deformations in situ, thus supporting the most challenging MX applications. In addition to crystallographic applications, the imaging assembly at P14 is used for investigation of multi-cellular organisms. The short time-scale for completing measurements and the existing automation of P14 allow us to apply high-throughput X-ray tomography, providing a way for large-field-of-view screening of biological samples prior to further high-resolution electron microscopy studies.\u0000\u0000[1] A. Snigirev, et al., Rev. Sci. Instrum., 66 (1995), 5486.\u0000[2] A. Snigirev, et al., Nature, 384 (1996) 49.\u0000[3] Fischer et al., Frontiers in Zoology 7:31 (2010).","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122955533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Application of synchrotron x-ray imaging and micro-CT to 4D visualization of multiphase flow inside a steel fuel nozzle (Conference Presentation) 同步x射线成像和微ct在钢燃料喷嘴内多相流4D可视化中的应用(会议报告)
Developments in X-Ray Tomography XII Pub Date : 2019-09-17 DOI: 10.1117/12.2527585
A. Tekawade, Brandon A. Sforzo, K. Matusik, A. Kastengren, C. Powell
{"title":"Application of synchrotron x-ray imaging and micro-CT to 4D visualization of multiphase flow inside a steel fuel nozzle (Conference Presentation)","authors":"A. Tekawade, Brandon A. Sforzo, K. Matusik, A. Kastengren, C. Powell","doi":"10.1117/12.2527585","DOIUrl":"https://doi.org/10.1117/12.2527585","url":null,"abstract":"The multi-phase flow within a steel diesel injector is imaged using synchrotron-produced X-rays from the Advanced Photon Source at Argonne National Laboratory. Projections gathered from several repeated injection events at up to 10,000 frames per second and with 2.1 micrometer resolution at various viewing angles resulted in a 4D data set. Photon statistics were improved by averaging the data over 200 injection events. Owing to significant attenuation caused by the injector body material, and the short exposure time, the images are obscured by various types of noise making tomographic reconstruction challenging. Attempts at denoising this data are discussed.\u0000\u0000At each time step, translational and rotational image registration was performed to align projections obtained from different lines-of-sight. This is followed by a Fourier Transform method for computed tomography to reconstruct the 3D flow-field, from the start to end of fuel injection, which is a 2 millisecond long event. The X-ray phase contrast in the data was exploited by applying a low-pass filter. Segmentation is performed to track the location of the liquid-gas interface, thus distinctly revealing a highly asymmetric flow-separation layer affected by micron-scale features in the nozzle geometry. This complete data processing pipeline converted the images acquired at a signal-to-noise ratio of 1 into a unique tomographic dataset of internal fluid flow through approximately 2 millimeters of steel. The data shows excellent validation with computational fluid dynamics simulations of the flow profile previously obtained for this nozzle.","PeriodicalId":417260,"journal":{"name":"Developments in X-Ray Tomography XII","volume":"295 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117050001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书