2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)最新文献

筛选
英文 中文
A new CCEM-K4 comparison of capacitance at 10 pF 一种新的CCEM-K4在10pf时的电容比较
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540687
P. Gournay, N. Fletcher, M. Stock
{"title":"A new CCEM-K4 comparison of capacitance at 10 pF","authors":"P. Gournay, N. Fletcher, M. Stock","doi":"10.1109/CPEM.2016.7540687","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540687","url":null,"abstract":"The CCEM-K4 key comparison of capacitance at 10 pF was last carried out between 1996 and 1999. The Consultative Committee for Electricity and Magnetism of the International Committee for Weights and Measures decided that it should be repeated in 2016. We present here the main technical choices adopted for the next comparison.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121986765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Stable arbitrary waveform generator as a transfer standard for ADC calibration 稳定的任意波形发生器作为ADC校准的传输标准
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540454
J. Nissila, M. Sira, J. Lee, T. Ozturk, M. Arifoviç, J. Díaz de Aguilar, R. Lapuh, R. Behr
{"title":"Stable arbitrary waveform generator as a transfer standard for ADC calibration","authors":"J. Nissila, M. Sira, J. Lee, T. Ozturk, M. Arifoviç, J. Díaz de Aguilar, R. Lapuh, R. Behr","doi":"10.1109/CPEM.2016.7540454","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540454","url":null,"abstract":"This paper describes a feasibility study of using a stable semiconductor digital-to-analog converter (DAC) based arbitrary waveform generator in audio frequency range up to 20 kHz for calibrating analog-to-digital converters (ADC). The source acting as a transfer standard is circulated in four national metrology institutes (NMI). The behavior of the source during the circulation is monitored using thermal converters, AC Quantum Voltmeters and sampling methods. The sampling techniques used by the partners in decomposing the waveforms are compared.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122817817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
10 Volt automated direct comparison of two cryocooled programmable Josephson voltage standards 10伏自动直接比较两个冷冻可编程约瑟夫森电压标准
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540474
A. Rufenacht, Yi-hua Tang, A. Fox, P. Dresselhaus, C. Burroughs, R. Schwall, S. Benz
{"title":"10 Volt automated direct comparison of two cryocooled programmable Josephson voltage standards","authors":"A. Rufenacht, Yi-hua Tang, A. Fox, P. Dresselhaus, C. Burroughs, R. Schwall, S. Benz","doi":"10.1109/CPEM.2016.7540474","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540474","url":null,"abstract":"We have performed direct dc comparisons between two cryocooled 10 V programmable Josephson voltage standards utilizing an automated synchronization scheme for the voltage reversals, which enables the use of a high sensitivity null detector on its 3 μV range by preventing any overload condition. No switches or manual operations are necessary to protect the null detector. Comparing the two systems under various test conditions provides robust verification of ideal system performance, and enables verification of the key components of the uncertainty budget for both the measurement methods and system operations.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125106038","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Tests on waveform synthesis in a new cryocooler setup 在新型制冷机装置中波形合成试验
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540563
A. Sosso, B. Trinchera, P. Durandetto, E. Monticone, O. Kieler, R. Behr, J. Kohlmann
{"title":"Tests on waveform synthesis in a new cryocooler setup","authors":"A. Sosso, B. Trinchera, P. Durandetto, E. Monticone, O. Kieler, R. Behr, J. Kohlmann","doi":"10.1109/CPEM.2016.7540563","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540563","url":null,"abstract":"A new experimental setup based on a two-stage cryocooler has been developed at INRIM for operation with Josephson arrays. Recently some parts of the setup have been upgraded in order to allow the synthesis of waveforms; in particular, a well suited rigid rf coaxial cable with bandwidth exceeding 30 GHz has been mounted. We describe preliminary results obtained in tests of waveform synthesis with pulse-driven Josephson arrays fabricated at PTB. Unipolar sinewaves at 1.25 kHz and amplitudes ranging up to tens of millivolts were generated. Results are then discussed in relation with the specific thermal issues posed by He-free cooling.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126415635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Algorithm for measuring amplitude and frequency deviations intended for PMU 用于测量PMU的幅度和频率偏差的算法
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540659
R. Carranza, Marco A. Rodríguez
{"title":"Algorithm for measuring amplitude and frequency deviations intended for PMU","authors":"R. Carranza, Marco A. Rodríguez","doi":"10.1109/CPEM.2016.7540659","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540659","url":null,"abstract":"Traceability of synchrophasors are constrained to the measurement of reduced variations of frequency and amplitude, if the combined effects of amplitude or phase modulation on the measurement results are not correctly ascertained. A technique is proposed for real-time measurement of simultaneous deviations of frequency and amplitude of a voltage signal that it is feasible for measuring in a given node in a power system. Knowledge of the instantaneous value of the amplitude and frequency in a power system provides an enhanced capability for monitoring of dynamic failures of the system allowing taking corrective actions from their inception.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129872715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
S parameters measurement of antennas under thermal stress 热应力下天线S参数测量
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540668
M. Charles, Yannick Le Sage, J. Lerat
{"title":"S parameters measurement of antennas under thermal stress","authors":"M. Charles, Yannick Le Sage, J. Lerat","doi":"10.1109/CPEM.2016.7540668","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540668","url":null,"abstract":"This paper highlights a process allowing both to establish and to quantify the temperature impact on the electromagnetic measurements in field emission between 2 antennas. We show the fabrication conditions of a radome in order to package one of the antennas, in order to vary the temperature inside the thermal chamber from 0°C to 50°C [1]. The results show the temperature influence on the electromagnetic properties of antenna and highlight the difficulty to get a thermal isotropy inside of radome.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128479795","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Robustness of single-electron pumps at sub-ppm level 亚ppm水平下单电子泵的稳健性
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540622
F. Stein, Ralf Behr, Martin Gotz, E. Pesel, Thomas Weimann, Klaus Pierz, H. Schumacher, F. Hohls
{"title":"Robustness of single-electron pumps at sub-ppm level","authors":"F. Stein, Ralf Behr, Martin Gotz, E. Pesel, Thomas Weimann, Klaus Pierz, H. Schumacher, F. Hohls","doi":"10.1109/CPEM.2016.7540622","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540622","url":null,"abstract":"Single-electron pumps (SEP's) based on tunable barrier quantum dots show the most promise as high-precision nanoampere quantum sources. They are treated as a good candidate in the context of a quantum representation of the SI base unit ampere. A key point for such a realization is the robustness of operation. Here we show the invariance of current at a sub-ppm level against variation of magnetic flux density, bias voltage on source and drain and the entrance gate voltage.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124516364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Fabrication of graphene quantum hall resistance standard in a cryogen-table-top system 低温台式系统中石墨烯量子霍尔电阻标准的制备
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540516
H. He, T. Janssen, S. Rozhko, A. Tzalenchuk, S. Lara‐Avila, R. Yakimova, S. Kubatkin
{"title":"Fabrication of graphene quantum hall resistance standard in a cryogen-table-top system","authors":"H. He, T. Janssen, S. Rozhko, A. Tzalenchuk, S. Lara‐Avila, R. Yakimova, S. Kubatkin","doi":"10.1109/CPEM.2016.7540516","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540516","url":null,"abstract":"We have demonstrated quantum Hall resistance measurements with metrological accuracy in a relatively easy to use and compact cryogen-free system operating at a temperature of around 3.8 K and magnetic field below 5 T. This advance in technology is due to the unique properties of epitaxial graphene on silicon carbide (SiC) which lifts the stringent requirements for quantum hall effect seen in conventional semiconductors. This paper presents the processes involved in fabrication and characterization of metrologically viable epitaxial graphene samples.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125085692","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A nonlinear verification device for nonlinear vector network analyzers 一种用于非线性矢量网络分析仪的非线性验证装置
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540467
D. Humphreys, Mohammad Rajabi, D. Schreurs, T. Nielsen
{"title":"A nonlinear verification device for nonlinear vector network analyzers","authors":"D. Humphreys, Mohammad Rajabi, D. Schreurs, T. Nielsen","doi":"10.1109/CPEM.2016.7540467","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540467","url":null,"abstract":"Verifying the calibration of a Nonlinear Vector Network Analyzer in a way that is not instrument specific requires a stable nonlinear device that is insensitive to port mismatch. We propose and explore the design of a nonlinear verification device to complement existing linear verification devices. We have evaluated a design operating at a fundamental frequency of 2 GHz and derived an improved figure of merit parameter that identifies sensitivity to load-pull.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130857924","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Development of calculable resistors at CENAM 可计算电阻器的研制
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) Pub Date : 2016-07-10 DOI: 10.1109/CPEM.2016.7540513
A. H. Pacheco Estrada, J. Moreno, F. Hernandez-Marquez
{"title":"Development of calculable resistors at CENAM","authors":"A. H. Pacheco Estrada, J. Moreno, F. Hernandez-Marquez","doi":"10.1109/CPEM.2016.7540513","DOIUrl":"https://doi.org/10.1109/CPEM.2016.7540513","url":null,"abstract":"This paper describes the new 1 kΩ and 10 kΩ Calculable Resistors that have been developed at CENAM in order to have a resistance reference standard at 1.592 kHz with traceability to the Quantum Hall Resistance. Important factors in the development of a Calculable Resistor like heat treatment and a welding technique are explained. Preliminary results shows a short term stability better than a few parts in 10<sup>8</sup> per day and temperature coefficients better than 0.5 (μΩ/Ω)/°C.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122575745","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信