Yunche Su, Mi Zhu, Ying Liu, Fang Liu, Q. Tang, You-bo Liu
{"title":"Expansion Planning of Transmission Grid Considering Congestion Surplus","authors":"Yunche Su, Mi Zhu, Ying Liu, Fang Liu, Q. Tang, You-bo Liu","doi":"10.1109/iSPEC48194.2019.8975251","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975251","url":null,"abstract":"Transmission grid planning under an electricity market with separated power generation, transmission, distribution and sale links, is facing more challenges, due to the market uncertainties. In this paper, based on marginal price, an optimal planning model of transmission grid considering power transaction is proposed to maximize congestion surplus. Adopting network voltage and investment budget constraints, dynamic differential evolution algorithm was used to figure out the model, yet, in lower rate of convergence. As a result, we combined the advantages of different iteration strategies, and proposed an improved dynamic differential evolution algorithm. In the simulations based on a west grid in China, algorithm convergence and validity are analyzed.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127870451","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
X. Cai, Yi Wang, Jialun Zhang, Jing Shi, Bingjie Li, C. Kang
{"title":"Data-Driven Load Data Cleaning and Its Impacts on Forecasting Performance","authors":"X. Cai, Yi Wang, Jialun Zhang, Jing Shi, Bingjie Li, C. Kang","doi":"10.1109/iSPEC48194.2019.8975047","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975047","url":null,"abstract":"Massive and various bad data may be introduced to load profiles in the process of data acquisition, transmission, and storage deliberately or accidentally such as cyber attacks and equipment failures. The bad data may result in bias for load forecasting and other data analytic applications. This paper proposes a novel bad data identification and repairing method for load profiles. In the first stage, Singular Value Thresholding (SVT) algorithm is applied to complete the missing data and detect the anomaly spikes roughly. In the second stage, quantile regression with lag value is performed to detect local fluctuation. How the data cleaning influences the forecasting performance is also investigated. Case studies on load of Fujian Province, China are conducted to verify the effectiveness of the proposed method.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"169 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131239745","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Steady-State Security Region Considering Post-Contingency Cascaded DC Commutation Failure","authors":"Bo Zhou, X. Ai, Jiakun Fang, Chengxiang Yang, Ruitong Liu, Yingxuan Yang, Fangwei Duan","doi":"10.1109/iSPEC48194.2019.8975025","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975025","url":null,"abstract":"With the enhanced interaction between the AC and DC power system, the post-contingency cascaded DC commutation failure (CF) has been a potential security risk. This paper proposes the steady-state security region (SSR) formulation with the post-contingency cascaded CF considered. The voltage reduction at the post-contingency quasi-steady-state is selected to identify the cascaded CF. The decoupled linearized power flow (DLPF) is introduced so that the voltage issues can make contributions to the SSR depiction. The proposed SSR provides the scope of the dispatch decisions where the cascaded CF can be inhibited. Case studies between different types of SSR are performed in the IEEE modified 9- and 30-bus test systems to validate the effectiveness of the proposed SSR.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"100 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131738599","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wind Power Prediction Based on the Clustered Combination of ARMA and PSO-SVM Methods","authors":"Yurong Wang, Dongchuan Wang","doi":"10.1109/iSPEC48194.2019.8975127","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975127","url":null,"abstract":"With the increase of installed capacity of wind power, the fluctuation of wind power has more and more obvious impact on the stable operation of power system. Wind power prediction is the key technology to improve the stability level of power system with large-scale integration of wind power. Based on the historical data of wind power, wind speed and temperature, this paper establishes an autoregressive moving average (ARMA) prediction model and a support vector machine (SVM) prediction model, moreover, Particle swarm optimization (PSO) algorithm is used to solve the problem of parameter optimization of SVM model. Considering the wind power prediction results of the two models, a combined prediction model based on ARMA model and PSO-SVM model is established based on covariance minimization method, and with the basis of clustering theory, a C-PSO-SVM-ARMA clustered combination model is proposed. In case study, prediction performance of different models is examined, and the clustered combination model C-PSO-SVM-ARMA model is verified as the best wind power prediction model.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125337954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimal Dispatching of Virtual Power Plant Considering the Uncertainty of PV","authors":"Jianchun Wang, Hui Dai, Meng Yang, Haoming Liu","doi":"10.1109/iSPEC48194.2019.8975226","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975226","url":null,"abstract":"The green and renewable distribution generation (DG) has gradually attracted people's attention with its wide, clean and sustainable characteristics. However, the DG connected to the grid will affect the economic operation of the grid. Virtual power plant (VPP) provides an opportunity to increase the popularity of green and renewable DG. In this paper, the model of VPP is established, then methods of scenario generation and reduction are used to deal with the uncertainty of photovoltaic (PV). With the aim of minimizing the total cost of VPP in a day, the economic dispatching model is built. Case study shows that, comparing to the mode without VPP, the dispatching in the mode of VPP considering the uncertainty of PV can improve the economic benefit at no less than 10.6%.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126605126","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on DC Power Control Strategy for Mitigating the Continuous Commutation Failure","authors":"Chenyi Zheng, Yi Tang, Fusuo Liu","doi":"10.1109/iSPEC48194.2019.8974972","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8974972","url":null,"abstract":"The method for suppressing the continuous commutation failure is a vital issue of AC/DC hybrid power systems. However, most of existing literature focus on DC control system and even the converter topology, which is not able to meet the needs of control strategy for actual systems at this stage. Therefore, a DC power control strategy to cope with the continuous commutation failure is proposed in this paper. Firstly, the reactive interaction characteristic of AC/DC system and the main cause of continuous commutation failure are analyzed, and a method for evaluating risk of continuous commutation failure based on critical voltage is proposed. Then DC power is reduced or restored in real time in order to improve the reactive power recovery characteristic of the DC system. Finally, the proposed strategy is verified by simulation based on the actual system. The result shows that the strategy can effectively mitigate the continuous commutation failure, and has fine engineering adaptability and application prospect.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"160 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123280829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Risk Assessment of Distribution System with wind power forecast based on Markov Model","authors":"Kaiyi Huang, Q. Ai, Jiakan Zhou, Yufan Zhang","doi":"10.1109/iSPEC48194.2019.8974957","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8974957","url":null,"abstract":"Integration of renewable resources based on distributed generation(DG) poses risks on distribution system. A risk assessment scheme of distribution system with uncertainty of wind power is proposed. The approaches are segmented into three parts: wind power forecast, island division and risk assessment. The hourly wind power forecast based on Markov model with simplicity, efficiency and accuracy is the premise of risk assessment. Then two island types(live island and dead island) are distinguished on the basis of island division under the condition of probabilistic line fault. Additionally, loss of load is selected as the risk indicator, and two levels of risk assessment of node risk and distribution system risk are put forward to analyze the reliability of the system. Finally, the results obtained from 33-bus system verify the effectiveness of the proposed method and the accurate analysis of node and system risks.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126202359","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Monitoring of Electric Distribution Grids: Existing, Priority, and Objective","authors":"M. Nayel, Mohamed Morad, W. Mohamed","doi":"10.1109/iSPEC48194.2019.8975343","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975343","url":null,"abstract":"The smart distribution grids monitoring process refers to consistently collect data related to all distributed resources conditions. The dynamic nature of distribution grid systems makes the monitoring tools to be essential in utilizing different types of distributed resources and providing smart services to users. This paper gives a general overview about distribution grid monitoring system and its challenges, technologies, aspects, key components, and important requirements. Also, it sets the rules for optimum locations and the scenarios for loss observation units.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122235538","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Lei, Wei He, Min Liao, Baozhi Zang, Jiabing Hu, Y. Chi
{"title":"Inertia Characteristics Analysis of DFIG-Based Wind Turbines with Virtual Synchronous Control in Different Operation Areas","authors":"Y. Lei, Wei He, Min Liao, Baozhi Zang, Jiabing Hu, Y. Chi","doi":"10.1109/iSPEC48194.2019.8975015","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975015","url":null,"abstract":"Large-scale integration of wind power reduces the inertia of power system, causing the deterioration of frequency dynamics. Equipping doubly fed induction generator (DFIG)-based wind turbines (WTs) with virtual synchronous control (VSynC) is an effective way to provide the desirable inertia support for power system. Although the inertia characteristics of DFIG-based WTs with VSynC were studied in some literature, the impact of different operation areas, where WTs’ working mode is different, on the inertia characteristics were barely focused. Based on the concept of motion equation, this paper presents a motion model of DFIG-based WTs considering the influences brought by different operation areas. Frequency-domain expressions of the inertia of DFIG-based WTs with VSynC in different operation areas are derived and the physical meaning of the inertia expression is explained. Then the inertia characteristics in different operation areas are studied and compared. Time-domain simulations of a typical system are conducted to verify the correctness of the analysis.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"207208 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115954633","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hafiz Muhammad Azib Khan, Qingmin Li, Jian Wang, Jingrui Wang, Qiuxiang Hu
{"title":"Experimental Analysis Effect of Particles Distance on the DC Breakdown Voltage in Coaxial Electrodes and Ball-Bowl Electrodes","authors":"Hafiz Muhammad Azib Khan, Qingmin Li, Jian Wang, Jingrui Wang, Qiuxiang Hu","doi":"10.1109/iSPEC48194.2019.8974918","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8974918","url":null,"abstract":"The electric field of DC breakdown voltage has attracted the researchers to evaluate various factors that affect it. In this research work, the focus is on the effect of the distance of separation between the particles on the breakdown voltage. This paper primarily aims to address the key differences between the conductive properties of two different types of electrodes - coaxial electrodes and ball-bowl electrodes. In its scope as a comparative study, the paper evaluates the aforementioned electrode types under two different experimental conditions. While the two experimental setups are almost identical, they differ in terms of crucial empirical values that govern the conditions of the experiment. The experiments are then conducted and differing outcomes are observed. After the experiments are carried out and evaluated, the breakdown voltages of the two different setups are measured respectively in with different sphere gaps in order to gauge the different outcomes empirically. Finally, the findings are shown to indicate that there is an evident variation between the positive and negative voltages of a coaxial electrode and a ball-bowl electrode.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"193 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116784401","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}