2019 IEEE Sustainable Power and Energy Conference (iSPEC)最新文献

筛选
英文 中文
Load Identification Method Based on Load Feature Extraction and Fuzzy C Mean Clustering Method 基于负荷特征提取和模糊C均值聚类的负荷识别方法
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975292
Chunlei Xu, Wenying Liu, Y. Nie
{"title":"Load Identification Method Based on Load Feature Extraction and Fuzzy C Mean Clustering Method","authors":"Chunlei Xu, Wenying Liu, Y. Nie","doi":"10.1109/iSPEC48194.2019.8975292","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975292","url":null,"abstract":"Load identification method can identify different types of loads in power systems. Adjustable loads have great potential in providing services to help consume the curtailed wind power. However, the consumption potential of the adjustable loads is difficult to be quantified. This paper makes an in-depth analysis of the necessity of extracting load characteristic parameters, then the characteristic parameters such as maximum adjustable speed, depth of adjustment, load fluctuation coefficient, maximum adjustable time, load time-shift coefficient are proposed. In order to improve the identification precision of adjustable load, the Daubechies fast wavelet transform is used to extract energy value as a new characteristic parameter. On this basis, fuzzy C mean clustering(FCM) is used to identify the load. Finally, through two examples of simulation and method comparisons in a certain area of Hexi, Gansu Province, the proposed identification method is verified that it can effectively improve the identification accuracy and precision of adjustable load.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128738341","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Detection of High-Impedance Line-Line Fault in Photovoltaic Arrays Based on Voltage Divider 基于分压器的光伏阵列高阻抗线路故障检测
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975269
Zhihua Li, Yang Yu, Chunhua Wu, Zhanfei Yang, Jiabin Meng
{"title":"Detection of High-Impedance Line-Line Fault in Photovoltaic Arrays Based on Voltage Divider","authors":"Zhihua Li, Yang Yu, Chunhua Wu, Zhanfei Yang, Jiabin Meng","doi":"10.1109/iSPEC48194.2019.8975269","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975269","url":null,"abstract":"High-impedance line-line fault in solar PV array with an active MPPT control is difficult to detect because of low fault current and similar output characteristics variations caused by external circumstances changes. PV system with undetected line-line fault may result in loss of energy and possess potential fire hazard. A detection method based on voltage divider is proposed in this paper. With two external resistors, the high-impedance line-line fault between two PV module strings can be found and located according to data measurement and processing. Experiment studies verify the accuracy and effectiveness of the proposed method.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127120421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Price Based Indirect Control Scheme of Load Aggregator for Residential Demand Response 基于价格的居民需求响应负荷聚合器间接控制方案
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975211
Huiji Wang, M. Zhou, Jian Zhang, Yanan Zheng, Kaining Luan
{"title":"Price Based Indirect Control Scheme of Load Aggregator for Residential Demand Response","authors":"Huiji Wang, M. Zhou, Jian Zhang, Yanan Zheng, Kaining Luan","doi":"10.1109/iSPEC48194.2019.8975211","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975211","url":null,"abstract":"The popularization of smart meters and smart appliances in households, as one of the achievements of smart grid development, provides a great opportunity for residential electricity consumer to participate in demand response (DR) programs. It is necessary to take full advantage of DR as a dispatchable resource for reducing the peak regulation pressure and the operation cost of the power system. Focused on price mechanism, this paper proposes an indirect control scheme of the load aggregator (LA) based on a two-layer model. The upper-layer is the optimization model of LA aiming to maximize the electricity sales profit from residential consumers (RCs) and the DR rewards from the independent system operator (ISO). The lower layer is the DR models of RCs. The LA realizes the indirect control over RCs by changing price signals under the constraint of not increasing the electricity cost of RCs who do not participant in DR. Each RC can independently respond to the price signals with the home energy management system (HEMS) to minimize the electricity consumption cost while ensuring the comfort by optimizing the electricity consumption behaviors. Simulation results show that the proposed indirect control scheme can obtain a mutually beneficial and win-win price signal, taking into account the interests of both the LA and RCs. This effective DR mechanism could realize friendly interaction between the ISO and RCs through the LA, which meets the requirements of system operation.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129945194","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Load Current Feedforward Control Method for Modular Multilevel DC Converter 模块化多电平直流变换器负载电流前馈控制方法
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975349
Guanqun Sun, Xianggen Yin, Zhenyu Qi, J. Lai, Zhen Wang
{"title":"Load Current Feedforward Control Method for Modular Multilevel DC Converter","authors":"Guanqun Sun, Xianggen Yin, Zhenyu Qi, J. Lai, Zhen Wang","doi":"10.1109/iSPEC48194.2019.8975349","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975349","url":null,"abstract":"To improve the response speed of the converter when the load changes, so that the converter is better used in precision equipment production and other occasions requiring high output voltage performance, the control method of dynamic performance optimization is studied for the operation control of MMC-H bridge DC converter in this paper. Firstly, the transmission power model of MMC-H bridge converter based on staircase modulation is established when there are N submodules in a half bridge. Secondly, based on the transmission power model, a novel power-based current feedforward control method is proposed. Finally, the simulation is carried out by taking four submodules of half bridge as an example. The response of the proposed control method, voltage closed-loop control and traditional current feedforward control are compared to verify the superiority of power-based current feedforward control.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128948303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Research and Application of Project Settlement Overdue Prediction Based on XGBOOST Intelligent Algorithm 基于XGBOOST智能算法的工程结算逾期预测研究与应用
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975056
R. Fan, Ya Li, Tao Ma
{"title":"Research and Application of Project Settlement Overdue Prediction Based on XGBOOST Intelligent Algorithm","authors":"R. Fan, Ya Li, Tao Ma","doi":"10.1109/iSPEC48194.2019.8975056","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975056","url":null,"abstract":"In order to strengthen the management of the company's project settlement, as well as ensures the completion of project settlement on time and quality according to the completion of the project, to improve the project management level, and strengthen the responsibilities, this paper analyzes the reasons for the project settlement overdue and proposes a project settlement based on XGBOOST algorithm. Overdue prediction model. Based on the historical engineering registration form and ERP data, the model sample data set is obtained through data predicting technology, and the XGBOOST prediction model is established. According to the relevant information of the project, the number of days in the settlement of the new completion project is predicted, and the standard days specified in the project management can be compared to the number of days exceeded, so that the relevant person in charge of the project overdue can be issued an early warning for 17 to 50 days in advance. The actual test results show that: The predicted days of the completion of the delivery of materials, non-material settlement, material settlement and asset creation are basically in line with the actual value, and the average absolute error rates of the predicted values are 14.55%, 8%, 11.38% and 8.25%, respectively.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129029563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Design of Power Supply for Air Core Reactor Monitoring System 空心电抗器监测系统电源设计
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975190
Yujia Zhao, Xiaohui Zhang, L. Zhen, R. Zhao, Gang Sun, Zhikuan Wang
{"title":"Design of Power Supply for Air Core Reactor Monitoring System","authors":"Yujia Zhao, Xiaohui Zhang, L. Zhen, R. Zhao, Gang Sun, Zhikuan Wang","doi":"10.1109/iSPEC48194.2019.8975190","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975190","url":null,"abstract":"In the operation of the power grid, the power supply devices of electrical equipment are often unable to monitor the electrical components in real time, and the existing technical means cannot be monitored in real time because of the failure of the power supply technology. Therefore, based on the structural characteristics of the air-core reactor, a new type of self-extracting device is proposed. The characteristics of the air-core reactor are used to provide continuous DC power to the temperature sensing element in the air reactor temperature measurement system, so that it can be monitored in real time. A kind of pre-vision protection before the failure occurs, which provides a guarantee for the safe operation of the air-core reactor.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130984399","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of Distributed Grounding Line Selection Application Based on GOOSE 基于GOOSE的分布式接地选线应用研究
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975061
J. Miao, Shi Yong, Dong Kaida, Hou Wei, Li Yuqi
{"title":"Study of Distributed Grounding Line Selection Application Based on GOOSE","authors":"J. Miao, Shi Yong, Dong Kaida, Hou Wei, Li Yuqi","doi":"10.1109/iSPEC48194.2019.8975061","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975061","url":null,"abstract":"This paper introduces a distributed grounding line selection method based on GOOSE, which is also implemented in the protection device. In the small current grounding system, when single phase grounding fault happens, fault current is quite small due to the switching of arc-extinguish coil decreasing the capacitive current, which makes it difficult to recognize the fault line using steady-state determination method. By employing wavelets decomposition methodology, discriminating the high frequency component of transient current and recognizing the grounding line rapidly and accurately can be achieved. With exploiting GOOSE of station control layer to share information among several devices, wavelets method is utilized to judge grounding line locally. The algorithm is verified through MATLAB simulation and the microprocessor-based protection embedded in the algorithm is validated in RTDS test. The scheme presents great application prospects and is worth popularizing.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132393510","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Capacity Planning Strategy of Distributed Wind Farm in Distribution Systems 配电系统中分布式风电场容量规划策略
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975085
Sixuan Xu, Yurong Wang
{"title":"Capacity Planning Strategy of Distributed Wind Farm in Distribution Systems","authors":"Sixuan Xu, Yurong Wang","doi":"10.1109/iSPEC48194.2019.8975085","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975085","url":null,"abstract":"The integration and local consumption of distributed wind power generation is an effective solution to avoid wind power curtailment, it can increase the utilization efficiency of wind source greatly. So far, there is no specified standard issued in China to determine the newly installation capacity of distributed wind farms. The unique criterion to determine that whether the power generated by the wind farms could be consumed locally is the value of valley load, since this can ensure the uniqueness of the power flow direction through the transformer that connects the wind farm. This criterion can relax the pressure of power dispatch and static operation. However, it also seriously weakens the utilization efficiency of wind source and leads to great discount of the economy of the wind power investment, because this criterion only concerns the valley point of local load without consideration of the cross correlation between wind power and local load in other conditions. In this paper, an optimization method for the capacity planning of distributed wind farm connected to power networks of 110kV or below is proposed, first, based on positive correlation characteristics of geographically near wind farms, the output power curves of the newly installed wind farm is forecasted based on a nearby installed in-operation centralized wind farm, and then instead of the rude and simply analysis on the valley load only, the actual output level of the distributed wind farm and the load curve are investigated, with the combination of a reasonable wind power curtailment strategy, the consumption level of wind power and the planning capacity of wind farm is derived. Study result of several practical cases in Jiangsu province shows that the planning capacity of the distributed wind farm can be increased effectively compared to that based on the aforementioned criterion, such that can benefit both demand side and supply side.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132473591","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Three-phase Power Flow Model of Low-voltage Distribution Network Considering Phase Asymmetry and Photovoltaic Access 考虑相位不对称和光伏接入的低压配电网三相潮流模型
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8974875
Zhou Xiaoyan, Huang Dezhi, L. Junyong, Tang Wei, He Xingqi, Yan-Hung Wei, Lu Zhengmei
{"title":"Three-phase Power Flow Model of Low-voltage Distribution Network Considering Phase Asymmetry and Photovoltaic Access","authors":"Zhou Xiaoyan, Huang Dezhi, L. Junyong, Tang Wei, He Xingqi, Yan-Hung Wei, Lu Zhengmei","doi":"10.1109/iSPEC48194.2019.8974875","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8974875","url":null,"abstract":"Due to the lack of phase angle information in the low-voltage (LV) distribution network, the existing three-phase power flow calculation methods in LV distribution network assume that the voltage phase angle of the slack bus is symmetric. In practice, the LV side of the actual distribution transformer is often asymmetric. Based on the actual smart meter measurements, taking phase A of the slack bus as zero phase reference point, the PV and PQ model of phase B and phase C for the slack bus are constructed. Considering the actual access mode and control mode of the photovoltaic inverter power supply (PIPS) in the LV distribution network, a more realistic power and voltage independent control model of three phase relative to the neutral point is established. Based on the above two constructed models, three-phase power flow model of low-voltage distribution network considering phase asymmetry and photovoltaic access is further proposed. The effectiveness of the model built in this paper is verified on the modified IEEE-13 bus distribution system. The simulation results show that the model constructed in this paper can effectively and accurately calculate the three-phase power flow in the LV distribution network.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132098635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimal Operation of Combined Heat and Power Micro-grid Based on Integrated Demand Response 基于综合需求响应的热电联产微网优化运行
2019 IEEE Sustainable Power and Energy Conference (iSPEC) Pub Date : 2019-11-01 DOI: 10.1109/iSPEC48194.2019.8975179
Lei He, Yuan Jiang, Chuanjun Pang, Tie Bao
{"title":"Optimal Operation of Combined Heat and Power Micro-grid Based on Integrated Demand Response","authors":"Lei He, Yuan Jiang, Chuanjun Pang, Tie Bao","doi":"10.1109/iSPEC48194.2019.8975179","DOIUrl":"https://doi.org/10.1109/iSPEC48194.2019.8975179","url":null,"abstract":"Combined heat and power (CHP) micro-grid has the characteristics of high energy utilization rate, flexible operation, and reliable energy supply mode, which makes it an important means to realize the transformation of energy production and consumption. The coupling relation of heat and electricity in the CHP micro-grid brings adverse effects to the flexibility and economy of the system operation. Therefore, this paper proposes a method for the operation optimization of the CHP micro-grid based on the integrated demand response (IDR). The IDR includes the thermal load response and the electric load response, which provides extra optimization space for the thermal and electric production of the CHP micro-grid. The thermal load response is based on the thermal model of the buildings, and the equation between the heating power and the indoor temperature is established. The electric load response includes the transferable load. Based on the IDR, a mixed integer linear programming (MILP) model is established to optimize the operation of the CHP micro-grid, which is then solved by the CPLEX software. The analysis results of the case study shows that the application of the IDR enhances the flexibility of the heat and power production of the CHP microgrid, and brings considerable economic benefits to the system operation.","PeriodicalId":413554,"journal":{"name":"2019 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130509924","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书