Analysis of Potential Alternative Energy Sources for Electricity Conservation in Yogyakarta State Finance Building 日惹州财政大楼电力节约的潜在替代能源分析
Journal of Electrical Technology UMY Pub Date : 2019-09-22 DOI: 10.18196/JET.3360
A. N. N. Chamim, Rahmat Adiprasetya Al Hasibi, Agus Jamal, Siva Aprilia, Y. Jusman, Jeckson Jeckson
{"title":"Analysis of Potential Alternative Energy Sources for Electricity Conservation in Yogyakarta State Finance Building","authors":"A. N. N. Chamim, Rahmat Adiprasetya Al Hasibi, Agus Jamal, Siva Aprilia, Y. Jusman, Jeckson Jeckson","doi":"10.18196/JET.3360","DOIUrl":"https://doi.org/10.18196/JET.3360","url":null,"abstract":"State Finance Building of Yogyakarta is a community service that is included in the types of buildings that consume electric energy that is large, so that often led to the power outage unexpectedly due to excessive use of electricity. This excessive use of electricity has also contributed to bill accounts for electricity from PLN which each month up to hundreds of millions of dollars. To that end, this research was undertaken that aim to be able to device that most optimal configuration in the use of solar panels and could compare the PLTS system between On-Grid and PLN in the aspect of cost and CO2 emissions.In knowing the potential of alternative energy sources, namely solar power connected to the PLN as the optimal power plant is carried out by means of conducting research in the form of knowing the intensity of the solar radiation data, data in the form  of electric power load is active for 24 hours, and data rates time of outside peak load and time of peak load from PLN for State Finance Building Of Yogyakarta. Later, she did the simulation using software to help homer modeling from use of the most optimal solar panel. In the research results obtained that the potential PLTS system that are connected with the grid PLN unfit to be carried out because the cost of the initial investment to expenses during the period of operation of the system including the high value of the NPC of $970,742. However, the potential of the power plant that are appropriate for the conditions on site research solar power plant was connected to the grid PLN power plant configuration that is optimized for without using batteries, use only PV with a capacity of 91,35 kW, the converter with a capacity of 400 kW, and power grid network of PLN the system transmitted to PLTS On-Grid of 552 kW.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121101754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Auditing of Power Quality on Building G5 of Universitas Muhammadiyah Yogyakarta 日惹穆罕默德大学G5楼电能质量审计
Journal of Electrical Technology UMY Pub Date : 2019-09-22 DOI: 10.18196/JET.3361
Agus Jamal, Slamet Suripto, Rama Okta Wiyagi, Dimas Bangkit Wijayanto, Y. Jusman, T. Prasetyo
{"title":"Auditing of Power Quality on Building G5 of Universitas Muhammadiyah Yogyakarta","authors":"Agus Jamal, Slamet Suripto, Rama Okta Wiyagi, Dimas Bangkit Wijayanto, Y. Jusman, T. Prasetyo","doi":"10.18196/JET.3361","DOIUrl":"https://doi.org/10.18196/JET.3361","url":null,"abstract":"Universitas Muhammadiyah Yogyakarta, as an educational institution, indeed uses the building as a supporting facility for all activities carried out. In each of the reviews, these activities, of course, use of electrical energy, but not infrequently the electrical energy used exceeds the limits of the reasonableness of the resulting use in financial swelling. An energy audit is an activity carried out periodically to determine the amount of energy consumption, irregularities in the system, and load imbalances that cause power losses in a building. These parameters can be obtained by measuring on the SDP panel using a power quality analyzer with IEEE 59-1992 as a obtained reference to the results of the average voltage fluctuations are still within the safe limits determined by PLN items, i.e., from 198 to 231 volts. THDv is still within the safe limit under 5%, as well as for the THDi is also still within the safe limit of tolerance of 15%. As a result of harmonic disturbances and load imbalances in the building G5 in 2018, the caused losses of power losses that need to be borne by Universitas Muhammadiyah Yogyakarta in the amount of Rp 9,210,133.09.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131189459","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of Reliability-based Systems of 20kv Distribution Network Disturbance on PT. PLN Rayon Panam PT. PLN Rayon Panam上20kv配电网扰动可靠性系统分析
Journal of Electrical Technology UMY Pub Date : 2019-09-20 DOI: 10.18196/JET.3359
Slamet Suripto, Karisma Trinanda Putra, Y. Jusman, Muhammad Rusydi Al Aroffi, J. Jamaaluddin
{"title":"Analysis of Reliability-based Systems of 20kv Distribution Network Disturbance on PT. PLN Rayon Panam","authors":"Slamet Suripto, Karisma Trinanda Putra, Y. Jusman, Muhammad Rusydi Al Aroffi, J. Jamaaluddin","doi":"10.18196/JET.3359","DOIUrl":"https://doi.org/10.18196/JET.3359","url":null,"abstract":"Electricity needs for each year has increased, this is due to an increase in people's lives. Reliability is an important factor in the operation of distribution system and is an important factor in the continuity of the waiter to the consumer. Several parameters are used as reference to megukur level of reliability of a distribution system that is SAIFI (avarage interuption of frequency index system) is a calculation of the number of failures or disruptions average - average one year, SAIDI (System of interruption Duration Index) index median duration - average system interruption during the year. In this study was also performed calculations eens (Expected Energy Not Supplied) This calculation is done because of disturbance at each feeder there is energy that can not be channeled, it can happen losses. Based on the calculation and analysis that the reliability index is obtained there are some feeder Rayon Panam categorized as not reliable because it has a high SAIFI value not in accordance with the target SPLN No. 68-2 1986 and IEEE std 1366-2003. Energy losses that can not be distributed annually sizeable each feeder. This indicates a feeder located at Panam Rayon considered less reliable, to the need for repairs and maintenance","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114327480","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative Analysis of The Use of LED and HPS Lights in PT. Bukit Asam 武吉阿萨姆邦使用LED和HPS灯的比较分析
Journal of Electrical Technology UMY Pub Date : 2019-09-19 DOI: 10.18196/JET.3358
Rahmat Adiprasetya Al Hasibi, Agus Jamal, Indar Surahmat, Tio Hardiyanto, Y. Jusman, Fardhan Arkan
{"title":"Comparative Analysis of The Use of LED and HPS Lights in PT. Bukit Asam","authors":"Rahmat Adiprasetya Al Hasibi, Agus Jamal, Indar Surahmat, Tio Hardiyanto, Y. Jusman, Fardhan Arkan","doi":"10.18196/JET.3358","DOIUrl":"https://doi.org/10.18196/JET.3358","url":null,"abstract":"The lamp is the main construction facility in the company that serves as a support for the activities of the economic system and mobility in the company. An analysis of the difference between the use of LED lights with HPS lamps at PT. Bukit Asam Tbk. reference is used to recommend the use of appropriate (technical) lighting equipment for industrial areas and to obtain better cumulative costs and energy savings for the company in the future. In this study using the lamp replacement method with the same lumen level comparison. The goal is that later the level of lighting produced is the same for each lamp. From the results of this study it was found that the technical use of 70W, 150W, 250W and 400W HPS lamps has an efficacy level of 84 to 123 lm / W. Whereas the 80W, 200W, 300W, 450W LED lamps are 90 lm / W and the results of the cumulative value or the total cost of operating and maintenance costs for 15 years between HPS lamps versus the LED lights that occur is that in HPS lamps the total cost incurred amounting to 20,604,230,235 rupiahs while for LED lamps it is 27,787,386,324 rupiahs which can be seen that the use of more economical lighting is HPS lamps.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115962474","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Detection of Cervical Cancer Based on Learning Vector Quantization and Wavelet Transform 基于学习向量量化和小波变换的宫颈癌检测
Journal of Electrical Technology UMY Pub Date : 2019-09-18 DOI: 10.18196/JET.3357
Dhimas Arief Dharmawan, Latifah Listyalina
{"title":"Detection of Cervical Cancer Based on Learning Vector Quantization and Wavelet Transform","authors":"Dhimas Arief Dharmawan, Latifah Listyalina","doi":"10.18196/JET.3357","DOIUrl":"https://doi.org/10.18196/JET.3357","url":null,"abstract":"Cervical cancer has became the common women dsease in the world. Mostly, cervical cancer has been already known lately, because it is very dificult to detect this in early stage. In this work, a computer based software using Learning Vector Quantization (LVQ) has been designed as the early cervical cancer detection aid tool. There are six methods before the detection is performed, namely preprocessing, contrast stretching, median filtering, morphology operation, image segmentation, and Wavelet Transform based feature extraction. In tihis work, 73 cervical cell images that consist of 50 normal images and 23 cancer images are used. 35 normal images and 14 cancer images are used to train the LVQ. Then, 23 normal images and 9 cancer images are used in the testing process. Our results show 88,89 % cancer image can be detected correctly (sensitivity), 100 % normal image can be detected corerctly (specificity), and 95,83 % for overall detection (accuracy).","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125248300","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of Differential Protection in a Main Power Transformer: A Case Study in PT Pertamina Geothermal Energy Area of Kamojang 主变压器差动保护评价——以卡莫江PT Pertamina地热能区为例
Journal of Electrical Technology UMY Pub Date : 2019-06-11 DOI: 10.18196/JET.3256
Gady Altama, Muhamad Yusvin Mustar, R. Syahputra, T. Prasetyo
{"title":"Evaluation of Differential Protection in a Main Power Transformer: A Case Study in PT Pertamina Geothermal Energy Area of Kamojang","authors":"Gady Altama, Muhamad Yusvin Mustar, R. Syahputra, T. Prasetyo","doi":"10.18196/JET.3256","DOIUrl":"https://doi.org/10.18196/JET.3256","url":null,"abstract":"The electric power system consists of various components, ranging from the components of generation, transmission, and distribution. The systems are quite expensive, so that excellent, reliable, and economic protection is needed to avoid internal and external faults.  The faults can trigger damage to components, especially on the main transformers in the Power Plant Geothermal Unit 4 of the Kamojang area managed by PT Pertamina Geothermal Energy. Disturbances that occur in the main transformers of various types so that the primary protection needed in the transformer is a differential relay to protect to avoid interference that occurs. This study discusses the comparison of theoretical differential relay calculation calculations with actual differential relay setting data in the Kamojang Unit 4 Geothermal Power Plant and simulates with ETAP 12.6 software. The problem that occurs in the main transformer of the Geothermal Power Unit Unit 4 Kamojang area is the difference in the slope 1 of the actual setting data with a mathematical calculation that is the actual setting data of 40% and the numerical calculation data worth 8.5%. Please note that the minimum slope one limit is 5%. PT Pertamina Geothermal Energy made slope one changes, so that differential relays are not too sensitive to the interference current that occurs within the protection zone of differential relays.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"116 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114235569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Report of Energy Audit in Building F1, F3, F4, and G6 of Universitas Muhammadiyah Yogyakarta 日惹穆罕默德大学F1、F3、F4、G6楼能源审计报告
Journal of Electrical Technology UMY Pub Date : 2019-06-10 DOI: 10.18196/JET.3255
Destria Yoga Ningrum, A. N. N. Chamim, R. Syahputra, J. Jamaaluddin
{"title":"Report of Energy Audit in Building F1, F3, F4, and G6 of Universitas Muhammadiyah Yogyakarta","authors":"Destria Yoga Ningrum, A. N. N. Chamim, R. Syahputra, J. Jamaaluddin","doi":"10.18196/JET.3255","DOIUrl":"https://doi.org/10.18196/JET.3255","url":null,"abstract":"Energy audits on buildings are carried out to determine the load profile of electrical energy usage and to avoid wasting electricity. This energy waste can cause the use of electricity in buildings that are not efficient. An electrical energy audit is carried out to produce actual data that is in accordance with existing building conditions. This study conducted on buildings F1, F3, F4, and G6 in Universitas Muhammadiyah Yogyakarta to determine the value of the intensity of energy consumption used, whether it is following the Indonesian National Standards Agency. Measurement of electrical energy consumption using a tool that is the Power Factor Analyzer. The results of the calculation of the value of the intensity of electrical energy consumption showed that the buildings of F1, F3, F4, and G6 at the Universitas Muhammadiyah Yogyakarta obtained an average energy intensity value of 10.18 kWh/month. In this case, building standards are known to be between 7.92 - 12.08, which means that the building standards are categorized as efficient because they are under established standards. Furthermore, the use of electrical energy consumption used in buildings F1, F3, F4, and G6 in Universitas Muhammadiyah Yogyakarta in a month that is equal to 190,952.769 kWh/month.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125512330","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of Power Transformer Insulation: A Case Study in 150 kV Bantul Substation 电力变压器绝缘分析——以150kv班图尔变电站为例
Journal of Electrical Technology UMY Pub Date : 2019-06-08 DOI: 10.18196/JET.3254
A. Hidayat, Agus Jamal, A. N. N. Chamim, R. Syahputra, Jeckson Jeckson
{"title":"Analysis of Power Transformer Insulation: A Case Study in 150 kV Bantul Substation","authors":"A. Hidayat, Agus Jamal, A. N. N. Chamim, R. Syahputra, Jeckson Jeckson","doi":"10.18196/JET.3254","DOIUrl":"https://doi.org/10.18196/JET.3254","url":null,"abstract":"Insulation of the transformer is one of the essential components. So that the quality of the resistance in the isolation of the transformer is essential to note the condition, in order to find out the condition of the transformer isolation, several tests must be performed, namely the polarization index, delta tangent, and break down voltage. In this study, all three tests were carried out on Transformer 1 in the 150 kV Bantul substation. Polarization index testing itself is testing the leakage current on the transformer isolation by comparing the test results for 1 minute with the results of the 10-minute drive test. While delta tangent is testing capacitive leakage current in the isolation transformer, and break down voltage is a test of the ability of the breakdown voltage in transformer insulation oil. Based on the results of the analysis, it can be seen that the value of the transformer polarization index in 2016 and 2018, the average value between the windings has been in the rating of 1.25-2.0. As for the delta tangent test results in 2016 and 2018, the value between the capacitive parts is already in the rating of 0.18% -0.36%. For the breakdown voltage test results in 2016 and 2018, the average breakdown voltage value is 43.9 kV/mm - 65.5 kV/mm. From these data, it can be concluded that the transformer isolation conditions in 2016 and 2018 are in good condition, although there was a decline in the transformer isolation conditions in 2016. However, the National Electric Company has made repairs and maintenance of the isolation transformer. This is seen due to an increase in the quality of transformer insulation in 2018. Repair and maintenance of transformer insulation are done to maximize the work system and the life of the transformer.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"214 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133805652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Retinal Blood Vessel Segmentation as a Tool to Detect Diabetic Retinopathy 视网膜血管分割作为检测糖尿病视网膜病变的工具
Journal of Electrical Technology UMY Pub Date : 2019-06-07 DOI: 10.18196/JET.3253
Dhimas Arief Dharmawan, Latifah Listyalina
{"title":"Retinal Blood Vessel Segmentation as a Tool to Detect Diabetic Retinopathy","authors":"Dhimas Arief Dharmawan, Latifah Listyalina","doi":"10.18196/JET.3253","DOIUrl":"https://doi.org/10.18196/JET.3253","url":null,"abstract":"The retina is an important part of the eye for humans. In besides its main function as part of the sense of sight, in the world medically, the retina after an image can be used to detect a number diseases, such as diabetic retinopathy. To detect a number of diseases, Retinal digital images taken using a digital fundus camera are used. In detecting diabetic retinopathy, digital images are needed segmented retina. Nevertheless, automatic segmentation of digital images the retina is a complex work, given the presence of artifacts as well as noise on the retinal digital image, evenly illuminated, intensity low, low contrast, and varying lengths of retinal blood vessels. In this research, a blood vessel segmentation software system has been designed through three stages image processing, namely (i) preprocessing, (ii) improving image quality, (iii) and segmentation of retinal blood vessels. With three image processing stages, the performance value is obtained, i.e . 84.62 .","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125907033","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of 4G LTE Indoor Networks Performance with Networks in the Engineering Faculty G5 Building Universitas Muhammadiyah Yogyakarta 日惹大学工程学院G5大楼4G LTE室内网络性能分析
Journal of Electrical Technology UMY Pub Date : 2019-06-06 DOI: 10.18196/JET.3252
Widyasmoro Widyasmoro, R. Syahputra, K. Purwanto, Dedy Prasetiyo, Y. Jusman
{"title":"Analysis of 4G LTE Indoor Networks Performance with Networks in the Engineering Faculty G5 Building Universitas Muhammadiyah Yogyakarta","authors":"Widyasmoro Widyasmoro, R. Syahputra, K. Purwanto, Dedy Prasetiyo, Y. Jusman","doi":"10.18196/JET.3252","DOIUrl":"https://doi.org/10.18196/JET.3252","url":null,"abstract":"Analysis of the performance of the LTE network with WiFi networks was carried out in the G5 building of the Faculty of Engineering, University of Muhammadiyah Yogyakarta, which is the building of the Faculty of Engineering Laboratory. This research was conducted by comparing the LTE network with indoor or indoor WiFi networks, measuring these two networks using the Network Analyzer and Wifi Analyzer application to obtain information on signal quality data based on KPI and TIPHON standardization, which shows RSRP, RSRQ, and Throughput values through measurement using the Network Analyzer and Wifi Analyzer application. From the results of research that has been done shows that the G5 building has a WiFi internet network that is superior to the LTE internet network. The overall condition of the Wifi network is in very good condition and is stable for each floor. While the LTE network even though it has increased conditions on the second floor but overall is in a bad condition to normal. The LTE network has an RSRP value with an average of -143 dBm, while a WiFi network with an average of -90 dBm. Then the LTE network has an RSRQ value with an average of -13 dBm, while the Wifi network with an average of -15 dBm. For LTE network throughput it has an average max. ping by 50.9 ms and min. ping is 864.5 ms, while WiFi networks have max average. ping by 24.3 ms and min. ping of 144.5 ms. From the results of these data show that the G5 Building has a good WiFi network and is superior to the LTE network.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116885970","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信