Retrieval analysis of an explanted NuNec cervical disc: A case report 外植的NuNec颈椎间盘的恢复分析:1例报告
Biotribology Pub Date : 2020-12-01 DOI: 10.1016/j.biotri.2020.100150
Göksu Kandemir , Simon Smith , John Andrews , Andrew Bowey , Thomas J. Joyce
{"title":"Retrieval analysis of an explanted NuNec cervical disc: A case report","authors":"Göksu Kandemir ,&nbsp;Simon Smith ,&nbsp;John Andrews ,&nbsp;Andrew Bowey ,&nbsp;Thomas J. Joyce","doi":"10.1016/j.biotri.2020.100150","DOIUrl":"10.1016/j.biotri.2020.100150","url":null,"abstract":"<div><p><span><span>Retrieval analyses allow investigation of the efficacy of artificial implants<span> to replace diseased or damaged natural joints. </span></span>Implants<span><span><span> are not always removed due to mechanical failure; a well-functioning implant may require removal due to causing pain. As an alternative treatment to fusion, </span>total disc replacement is an evolving treatment. Recently, to eliminate the possible failure mechanisms observed in metal-on-polymer and metal-on-metal artificial discs, an all-polymer cervical artificial disc has been introduced. The NuNec cervical </span>arthroplasty<span><span> system is a self-mating, all-polymer design which utilizes a ball-in-socket configuration with each component made of polyether ether ketone. For the first time, a retrieval analysis of a NuNec cervical disc, which has been removed due to pain from a 54-year-old female patient, has been undertaken. The main reason associated with pain was the size of the implant which was found to be too big for the patient. The time in vivo of the implant was 2 years and at the time of removal, the implant was thought to be functioning well. The average </span>surface roughness values of the socket and the ball of the explanted NuNec disc were measured as 0.067 ± 0.056 μm (Sa) and 0.037 ± 0.023 μm (Sa). Compared to an unused disc, the surface roughness significantly decreased (</span></span></span><em>p</em><span> = 0.00). The articulating surfaces<span> of the explant had negative skewness and burnished appearances. Evidence for both abrasive and adhesive wear mechanisms was observed on the explant. The hydroxyapatite coatings at the backsides were completely lost.</span></span></p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"24 ","pages":"Article 100150"},"PeriodicalIF":0.0,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2020.100150","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44074798","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Corrigendum to “In Vitro Wear Performance of X-ray Cross-Linked Vitamin E Blended Polyethylene” Biotribology 21 (2020) 100115 “x射线交联维生素E混合聚乙烯的体外磨损性能”生物摩擦学21 (2020)100115
Biotribology Pub Date : 2020-12-01 DOI: 10.1016/j.biotri.2020.100148
M.A. Mulliez , B. Fritz , M. Holderied , C. Schilling , T.M. Grupp
{"title":"Corrigendum to “In Vitro Wear Performance of X-ray Cross-Linked Vitamin E Blended Polyethylene” Biotribology 21 (2020) 100115","authors":"M.A. Mulliez ,&nbsp;B. Fritz ,&nbsp;M. Holderied ,&nbsp;C. Schilling ,&nbsp;T.M. Grupp","doi":"10.1016/j.biotri.2020.100148","DOIUrl":"10.1016/j.biotri.2020.100148","url":null,"abstract":"","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"24 ","pages":"Article 100148"},"PeriodicalIF":0.0,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2020.100148","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45153071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Study of Skin Physiology, Sensation and Friction of Nonwoven Fabrics Used in Absorbent Hygiene Products in Neutral and Warm Environments 中性和温暖环境下吸水性卫生用品用非织造布的皮肤生理、感觉和摩擦研究
Biotribology Pub Date : 2020-12-01 DOI: 10.1016/j.biotri.2020.100149
Lanjun Yin, Eunkyoung Shim, Emiel DenHartog
{"title":"A Study of Skin Physiology, Sensation and Friction of Nonwoven Fabrics Used in Absorbent Hygiene Products in Neutral and Warm Environments","authors":"Lanjun Yin,&nbsp;Eunkyoung Shim,&nbsp;Emiel DenHartog","doi":"10.1016/j.biotri.2020.100149","DOIUrl":"10.1016/j.biotri.2020.100149","url":null,"abstract":"<div><p><span><span><span>Absorbent hygiene products like diapers, </span>feminine hygiene, and wet wipes are life necessities. These products commonly use </span>nonwoven fabrics as the layer that is in contact with the skin. Their performance in terms of skin health and comfort is receiving increased attention because of the existence of concerns for skin health issues such as </span>skin irritation<span> and dermatitis, and the large influence of skin sensation on individuals' preference. Friction is usually recognized as an important factor for skin comfort and dermatitis issues, but there is a lack of understanding of the relationship between friction and skin physiology<span>, skin sensation, in the use of absorbent hygiene products. This study reports a measurement of friction in vivo with the evaluation of skin physiology and sensation in neutral and warm environments to explore the effects of fabric and friction on skin comfort. Friction tests between the volar forearm and nonwoven fabrics were conducted with the measurement of transepidermal water loss<span>, skin redness, and the evaluation of subjective skin sensation. The interaction between skin and eight nonwoven fabrics with a surface roughness (arithmetic mean height) between 3 μm and 20 μm was evaluated in neutral (22 °C) and warm (35 °C) environments. Skin physiological changes after friction were able to be detected quantitatively by the transepidermal water loss and skin redness measurement. In the warm environment, there was significantly higher friction, less pleasantness, more changes in transepidermal water loss but not in skin redness. The friction can only relate to skin physiology and sensation in the neutral environment while the surface roughness of fabrics related to them in both neutral and warm environments. Both rough and smooth fabrics caused high friction in the warm environment, but the rough fabric caused a higher adverse impact on skin physiology and sensation than smooth fabrics that suggested the adhesion and deformation friction could have different effects on skin comfort. Deformation friction is more likely to have effects on skin physiology and pleasantness sensation than adhesion friction. The pleasantness sensation has a negative relationship with skin physiology. A more unpleasant sensation can indicate more impact on skin physiology. This provides a potential that the unpleasant sensation can be a precaution signal for the adverse effects on skin physiology.</span></span></span></p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"24 ","pages":"Article 100149"},"PeriodicalIF":0.0,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2020.100149","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43718201","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
PEEK-matrix composites containing different content of natural silica fibers or particulate lithium‑zirconium silicate glass fillers: Coefficient of friction and wear volume measurements peek基复合材料含有不同含量的天然二氧化硅纤维或颗粒型硅酸锂锆玻璃填料:摩擦系数和磨损体积的测量
Biotribology Pub Date : 2020-12-01 DOI: 10.1016/j.biotri.2020.100147
Júlio C.M. Souza , Marta S.T. Correia , Miguel Noronha Oliveira , Filipe S. Silva , Bruno Henriques , Antonio P. Novaes de Oliveira , José R. Gomes
{"title":"PEEK-matrix composites containing different content of natural silica fibers or particulate lithium‑zirconium silicate glass fillers: Coefficient of friction and wear volume measurements","authors":"Júlio C.M. Souza ,&nbsp;Marta S.T. Correia ,&nbsp;Miguel Noronha Oliveira ,&nbsp;Filipe S. Silva ,&nbsp;Bruno Henriques ,&nbsp;Antonio P. Novaes de Oliveira ,&nbsp;José R. Gomes","doi":"10.1016/j.biotri.2020.100147","DOIUrl":"10.1016/j.biotri.2020.100147","url":null,"abstract":"<div><p><span>The purpose of this work was to evaluate the friction and sliding wear behavior of poly-ether-ether ketone (PEEK) matrix composites containing natural amorphous silica fibers (NASF) or particulate lithium‑zirconium silicate (LZSA) glass-ceramics. PEEK and PEEK containing different weight content (10, 20, and 30 wt%) of LZSA or NASF were processed by hot pressing. Reciprocating sliding wear tests were performed on the specimens in </span>artificial saliva<span> solution against an alumina ball on 30 N normal force. Tests were performed at 1 Hz sliding frequency, and at 4 mm stroke length in artificial saliva solution. The worn surfaces were morphologically inspected by field emission guns scanning electron microscopy (FEGSEM) to calculate the wear volume. Coefficient of friction values recorded on PEEK or PEEK-NASF composites against alumina were lower than those on PEEK-LZSA composites. The presence of LZSA particles negatively affected the wear resistance of the PEEK composites. On sliding tests mimicking oral conditions, PEEK composites containing NASF revealed low friction and high wear resistance close to that one exhibited by PEEK. Such results can stimulate further studies on the processing and tribological characterization of PEEK composites including different percentage of natural amorphous silica fibers.</span></p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"24 ","pages":"Article 100147"},"PeriodicalIF":0.0,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2020.100147","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41425975","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Bioinspired Self-Assembled 3D Patterned Polymer Textures as Skin Coatings Models: Tribology and Tactile Behavior 仿生自组装三维图案聚合物纹理作为皮肤涂层模型:摩擦学和触觉行为
Biotribology Pub Date : 2020-12-01 DOI: 10.1016/j.biotri.2020.100151
Ruting Jin , Lisa Skedung , Colette Cazeneuve , Jeanne C. Chang , Mark W. Rutland , Marina Ruths , Gustavo S. Luengo
{"title":"Bioinspired Self-Assembled 3D Patterned Polymer Textures as Skin Coatings Models: Tribology and Tactile Behavior","authors":"Ruting Jin ,&nbsp;Lisa Skedung ,&nbsp;Colette Cazeneuve ,&nbsp;Jeanne C. Chang ,&nbsp;Mark W. Rutland ,&nbsp;Marina Ruths ,&nbsp;Gustavo S. Luengo","doi":"10.1016/j.biotri.2020.100151","DOIUrl":"10.1016/j.biotri.2020.100151","url":null,"abstract":"<div><p><span><span>It is well known that during evolution, specific surface patterns emerged (e.g., on lotus leaves and butterfly wings) endowed with many remarkable surface properties (superhydrophobicity, vibrant structural color, delicate textures, etc.). In order to obtain these natural effects in cosmetics, we look for ways to transfer topographic patterns in coatings and treatments. Textured </span>polymer surfaces<span><span><span> were studied to explore their friction properties on the microscale<span> and possible correlations with human tactile friction on the macroscale. We have chosen self-assembling block and random </span></span>copolymers<span><span> as model systems to prepare reliable biomimetic films with different micrometer and </span>nanometer<span><span> scale randomly patterned and randomly rough surfaces. The surface texture of the films was characterized by atomic force microscopy (AFM), and their tribological (friction) properties were studied with a surface forces apparatus (SFA) at a </span>low sliding speed<span> of 3 μm/s and at a speed of 10 cm/s relevant to realistic applications. The results are evaluated in terms of polymer segment<span> mobility, interpenetration, entanglement and relaxation at interfaces, surface texture as described by </span></span></span></span></span>roughness parameters<span>, and interlocking of asperities. A stiction spike (static friction) was commonly found for the randomly patterned glassy polymer films. Random roughness patterns made from semi-crystalline polymers above their </span></span></span><em>T</em><sub>g</sub><span> gave high friction at low speed, but their friction coefficients were reduced at high speed due to less time for local entanglement and relaxations. The friction response of one of them was also affected differently by humidity than that of glassy polymer films. Tactile friction measurements with a human finger sliding against the polymer films revealed that the textures also provided differences at the macroscale, although the dynamic changes possibly due to lipid transfer, occlusion of moisture and/or damage of the films makes it difficult to draw robust conclusions. Finally, as an example, it is shown that these textures can be transferred to a soft elastomeric skin mimic substrate. This study introduces the concept of surface patterning by self-assembly to deliver tactile sensorial properties in coatings.</span></p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"24 ","pages":"Article 100151"},"PeriodicalIF":0.0,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2020.100151","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43819906","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Effects of Mucin on the dexterity and tactile sensitivity of medical glove users 粘蛋白对医用手套使用者灵巧性和触觉敏感性的影响
Biotribology Pub Date : 2020-12-01 DOI: 10.1016/j.biotri.2020.100146
Daniel Preece, Roger Lewis, Matt J. Carré
{"title":"Effects of Mucin on the dexterity and tactile sensitivity of medical glove users","authors":"Daniel Preece,&nbsp;Roger Lewis,&nbsp;Matt J. Carré","doi":"10.1016/j.biotri.2020.100146","DOIUrl":"10.1016/j.biotri.2020.100146","url":null,"abstract":"<div><p><span><span><span>The evaluation of medical glove performance has mostly focused on analysing how good a barrier the glove materials are, as well as their durability. Very few studies aim to determine how these gloves affect the performance of the user. This could lead to a lowered ability to carry out tasks, leading to poor healthcare due to diminished sensitivity and dexterity. Furthermore, none of these studies incorporate contaminants to replicate the real-world environments in which medical gloves are used. The work carried out here aims to look at the effects of the bodily fluid mucin on medical glove user's performance. This was assessed via the use of the Purdue Pegboard and Crawford Small Parts Dexterity Test in conjunction with a tactile bump sensitivity test. These tests were carried each in five conditions; bare hand, donned natural rubber latex (NRL) and donned </span>acrylonitrile </span>butadiene<span> rubber (XNBR) gloves – both with and without a 10 mg/ml concentration of porcine gastric mucin applied. The results show that donning gloves decreased dexterity and sensitivity compared to the bare hand. However, mucin was shown to increase dexterity and sensitivity in XNBR, but not with NRL. This is expected to be due to the different ways in which the materials interact with the mucin, affecting the ability to develop a muco-adhesive film and changing the </span></span>frictional properties of the glove materials.</p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"24 ","pages":"Article 100146"},"PeriodicalIF":0.0,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2020.100146","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48604876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Responsive polysaccharide-grafted surfaces for biotribological applications 用于生物核糖应用的响应性多糖接枝表面
Biotribology Pub Date : 2019-06-01 DOI: 10.1016/j.biotri.2019.100092
Clementine Pradal , Gleb E. Yakubov , Martin A.K. Williams , Michael A. McGuckin , Jason R. Stokes
{"title":"Responsive polysaccharide-grafted surfaces for biotribological applications","authors":"Clementine Pradal ,&nbsp;Gleb E. Yakubov ,&nbsp;Martin A.K. Williams ,&nbsp;Michael A. McGuckin ,&nbsp;Jason R. Stokes","doi":"10.1016/j.biotri.2019.100092","DOIUrl":"10.1016/j.biotri.2019.100092","url":null,"abstract":"<div><p><span><span>The elucidation of biolubrication mechanisms and the design of artificial biotribological contacts requires the development of model surfaces that can help to tease out the cues that govern friction in biological systems. Polysaccharides<span> provide an interesting option as a biotribological mimic due to their similarity with the glycosylated molecules present at biointerfaces. Here, pectin was successfully covalently grafted at its reducing end to a </span></span>polydimethylsiloxane (PDMS) surface via a reductive amination reaction. This method enabled the formation of a wear resistant pectin layer that provided enhanced </span>boundary lubrication<span> compared to adsorbed pectin. Pectins with different degrees of methylesterification and blockiness were exposed to salt solutions of varying ionic strength<span> and displayed responsiveness to solvent conditions. Exposure of the grafted pectin layers to solutions of between 1 and 200 mM NaCl resulted in a decrease in boundary friction and an increase in the hydration and swelling of the pectin layer to varying degrees depending on the charge density of the pectin, showing the potential to tune the conformation and friction of the layer using the pectin architecture and environmental cues. The robust and responsive nature of these new pectin grafted surfaces makes them an effective mimic of biotribological interfaces and provides a powerful tool to study the intricate mechanisms involved in the biolubrication phenomenon.</span></span></p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"18 ","pages":"Article 100092"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2019.100092","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49417086","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Changes in the morphology of microgrooved stem tapers with differing assembly conditions 不同装配条件下微槽茎尖形态的变化
Biotribology Pub Date : 2019-06-01 DOI: 10.1016/j.biotri.2019.100096
Karl Dransfield, Radu Racasan, James Williamson, Paul Bills
{"title":"Changes in the morphology of microgrooved stem tapers with differing assembly conditions","authors":"Karl Dransfield,&nbsp;Radu Racasan,&nbsp;James Williamson,&nbsp;Paul Bills","doi":"10.1016/j.biotri.2019.100096","DOIUrl":"10.1016/j.biotri.2019.100096","url":null,"abstract":"<div><h3>Background</h3><p>Fretting and corrosion at the head-stem taper junction has been cited as a potential clinical concern. Material loss measurement is a vital tool for quantifying changes due to in vitro, in vivo, and/or ex-vivo implant experience. Material loss measurement requires reconstruction of pre-implantation geometry to delineate damage. This is straightforward in principle for plain machined tapers, integrating between a fitted interpolated cone and the measured data. Mathematical filtration methods have been developed to remove this texture and facilitate measurement. The extent to which the assembly process could influence filtration accuracy is not currently known.</p></div><div><h3>Methods</h3><p><span>An engagement/ disengagement study was performed on 27 head/ stem pairs using 2, 4, and 8kN impact loads. Impact was delivered in three locations; axial, 10</span><sup>o</sup> anterior, and 10<sup>o</sup><span> anteroproximal. Pull-off force was measured, and stems were measured pre and post assembly using a Talyrond 365 roundness measurement machine.</span></p></div><div><h3>Results</h3><p>An increase in the plastic deformation<span><span> of microgrooves and pull-off force was noted with increasing assembly loads. Off-axis impaction resulted in reduced pull-off strength and reduced uniform microgroove distortion. </span>Volumetric change between pre and post assembly was below the noise threshold on stem and head surfaces.</span></p></div><div><h3>Discussion</h3><p>The measurement method was shown to be capable of capturing linear microgroove deformation of 1 μm peak – peak and volume loss above 0.1mm<sup>3</sup>. Lower peak load was noted when impacting a seated head when compared with engagement of discrete heads and stems, under the same assembly conditions.</p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"18 ","pages":"Article 100096"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2019.100096","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46184285","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Effect of Surface Finish on Wettability and Bacterial Adhesion of Micromachined Biomaterials 表面光洁度对微机械生物材料润湿性和细菌粘附性的影响
Biotribology Pub Date : 2019-06-01 DOI: 10.1016/j.biotri.2019.100095
Santhosh Kumar S. , Somashekhar S. Hiremath , Balaji Ramachandran , Vignesh Muthuvijayan
{"title":"Effect of Surface Finish on Wettability and Bacterial Adhesion of Micromachined Biomaterials","authors":"Santhosh Kumar S. ,&nbsp;Somashekhar S. Hiremath ,&nbsp;Balaji Ramachandran ,&nbsp;Vignesh Muthuvijayan","doi":"10.1016/j.biotri.2019.100095","DOIUrl":"10.1016/j.biotri.2019.100095","url":null,"abstract":"<div><p><span>Bacterial infection is one of the major complications occurs in biomedical implants<span><span><span>. Bacterial adhesion on the </span>implant surfaces<span><span> can form a biofilm, which leads to infection and failure at an earlier phase of implantation. So the surface properties of the implant such as surface topography<span>, surface energy, and chemistry play a crucial role in bacterial adhesion. For decades, several surface finishing techniques have been developed to alter the surface properties in turn to reduce the bacterial adhesion. Most of these implants exhibit freeform surfaces which are difficult to finish with available finishing methods to obtain the uniform surface properties. The current paper focused on the development of a unidirectional </span></span>abrasive flow finishing<span> process used to finish biomaterials- stainless steel (SS316L) and titanium alloy (Ti-6Al-4 V ELI) with two different abrasive media and a varying number of cycles. The purpose of this study is to evaluate the effect of this finishing process on enhancing the surface characteristics like surface finish, surface topography and its role on wettability and initial bacterial adhesion. Optical profilometer and a </span></span></span>scanning electron microscope<span><span> are used to examine the surface topography and surface morphology of the finished surfaces. The </span>goniometer is used to study the wettability of the finished samples using the sessile drop technique. Further, for the bacterial adhesion study both Gram-negative </span></span></span><em>Escherichia coli</em> (<em>E. coli</em>) and Gram-positive <span><em>Staphylococcus aureus</em></span> (<em>S. aureus</em>) are selected because these bacterial strains were commonly found on implant-related infections. The obtained result shows that, the surface finish and topography influences on wettability and bacterial adhesion. In conclusion, these results demonstrate that the possibilities of the developed process to enhance the surface finish of the biomedical implants which in turn reduce the implant-related infections and chances of early phase implant failure.</p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"18 ","pages":"Article 100095"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2019.100095","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44976110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Fretting-corrosion of cardiovascular stent materials: The role of electrochemical polarisation on debris generation mechanisms 心血管支架材料的微动腐蚀:电化学极化对碎片产生机制的作用
Biotribology Pub Date : 2019-06-01 DOI: 10.1016/j.biotri.2019.100093
Emily R. Clark , Karen E. Porter , Michael G. Bryant
{"title":"Fretting-corrosion of cardiovascular stent materials: The role of electrochemical polarisation on debris generation mechanisms","authors":"Emily R. Clark ,&nbsp;Karen E. Porter ,&nbsp;Michael G. Bryant","doi":"10.1016/j.biotri.2019.100093","DOIUrl":"10.1016/j.biotri.2019.100093","url":null,"abstract":"","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"18 ","pages":"Article 100093"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2019.100093","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46518841","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信