Vacuum arc characters research on DC forcing interruption 直流强制中断真空电弧特性研究
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122940
B. Liu, Jianwen Wu, Liying Zhu, Yihang Sun
{"title":"Vacuum arc characters research on DC forcing interruption","authors":"B. Liu, Jianwen Wu, Liying Zhu, Yihang Sun","doi":"10.1109/ICEPE-ST.2011.6122940","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122940","url":null,"abstract":"In this paper, the characters of the vacuum arc parameters in 270V DC forcing interruption were investigated. In which we considered some factors, such as the forcing frequency, the rate of the current and voltage at zero passage (di/dt, dv/dt), the charging voltage of the commutation circuit capacity, and the current magnitude. The experiment was performed on a synthetic test circuit, which composed by the RC main current circuit, LC commutation circuit and a cup type AMF contactor, which electrodes' diameter is 66mm, and gap is 4mm and a plane one for miniaturization use. The experiment showed that with the forcing frequency increases (2.3 kHz, 3.1 kHz, and 4.2 kHz) and other factors the same, the forcing arc duration decreased obviously, and the rate of the di/dt raised. Meanwhile the peak of the arc overvoltage raise, the voltage noise get smooth, and the inverse arc current peak increase. In other experiments, we fixed the di/dt. Under the same circuit parameters, the current magnitude influenced the current and voltage peak value, And the charging voltage determine the arc duration. 3 types waveform for the failure interruption, and the di/dt-dv/dt characteristics was investigated. And finally compare the obviously difference of post-arc current between AMF and plane VI, The knowledge may guides us to optimize a smaller apparatus for utility use.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114698522","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Chaotic analysis of High Voltage SF6 circuit breaker during breaking process Part I: Electric field chaos of the arc quenching chamber 高压SF6断路器分断过程混沌分析第一部分:灭弧室电场混沌
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122954
Xiaoming Liu, X. Leng, Yundong Cao, Yunxue Zhao, Zhengbo Li
{"title":"Chaotic analysis of High Voltage SF6 circuit breaker during breaking process Part I: Electric field chaos of the arc quenching chamber","authors":"Xiaoming Liu, X. Leng, Yundong Cao, Yunxue Zhao, Zhengbo Li","doi":"10.1109/ICEPE-ST.2011.6122954","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122954","url":null,"abstract":"A 252kV High Voltage SF6 circuit breaker (HV SF6 CB) is taken as an example in this paper, CC method and Wolf algorithm are applied to identify the chaotic characteristic of the electric field during the breaking process, and it is shown that the chaos phenomena exists in the variation of the electric field strength, especially each observation points exist chaos. And the distribution of the chaotic characteristic in the electric field has the consistency and uniformity feature. Compared with the gas flow characteristic during the breaking process, the prediction of the discharge possibility and insulation weakness is found.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"134 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127370436","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
An approach to diagnose pressure hazard of vacuum bulbs 真空灯泡压力危害的诊断方法
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122981
O. Yamamoto, H. Naruse, H. Morii
{"title":"An approach to diagnose pressure hazard of vacuum bulbs","authors":"O. Yamamoto, H. Naruse, H. Morii","doi":"10.1109/ICEPE-ST.2011.6122981","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122981","url":null,"abstract":"Vacuum bulbs may encounter the pressure rise hazard that results in failure in interrupting over currents in power systems. The pressure may unexpectedly increase due to a slow leak through cracks after a long period of operation in the power system. Several methods for monitoring the pressure onsite have been proposed so far, but most of them are poor in the ability to checkup the hazardous pressure level of 1 Pa or less. The present paper reports the results of a primitive attempt conducted for diagnostic purposes. In the study, by monitoring the electrification on the insulator surface of a real vacuum bulb, we successfully provide a method to detect the pressure rise around 10−1 Pa.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125670887","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Isolation fault forecasting model for intelligent high voltage circuit breaker 智能高压断路器隔离故障预测模型
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122968
Yun Teng, Jianyuan Xu, Xin Lin
{"title":"Isolation fault forecasting model for intelligent high voltage circuit breaker","authors":"Yun Teng, Jianyuan Xu, Xin Lin","doi":"10.1109/ICEPE-ST.2011.6122968","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122968","url":null,"abstract":"A novel risk forecasting model of high voltage circuit breaker insulation based on double artificial neural networks is proposed in the paper by analysis of the relationship between ESDD, flashover voltage and environmental factors. The data used to build the forecasting model is obtained from artificial pollution test. The proposed insulation fault risk forecasting model calculates the insulation fault probability under given environmental factors. Results of artificial pollution text indicate that the forecasting of this method is satisfied to practical application and useful to theoretical research.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125061175","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical research on switching arc of circuit breaker 断路器开关电弧的数值研究
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6123036
M. Rong, Yi Wu, Fei Yang, C. Niu, Ruiguang Ma
{"title":"Numerical research on switching arc of circuit breaker","authors":"M. Rong, Yi Wu, Fei Yang, C. Niu, Ruiguang Ma","doi":"10.1109/ICEPE-ST.2011.6123036","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6123036","url":null,"abstract":"This paper focuses on the numerical investigation of arc plasma behaviour in arc chamber of direct current (DC) circuit breaker. A 3-D simulation model of arc chamber including ferromagnetic splitter plates is built and calculated, which is based on magneto-hydrodynamics theory. Coupled electromagnetic and gas dynamic interactions are considered as usual, and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc roots. Therefore, the arc-splitting process with ferromagnetic plates can be included. To reduce the time consuming, the arc simulation results of arc commutation process from contact to arc runner is taken as the calculation initial condition in the model. Arc motion is described in detail by the temperature distribution. Moreover, the simulation result is compared with experimental result, which shows good agreement.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"114 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123413047","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Study on the bifurcation of the shock wave in SF6 circuit breaker SF6断路器冲击波分岔的研究
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122960
Ying Han, Xiaoming Liu, Yuejun An, Yunxue Zhao, Liying Li
{"title":"Study on the bifurcation of the shock wave in SF6 circuit breaker","authors":"Ying Han, Xiaoming Liu, Yuejun An, Yunxue Zhao, Liying Li","doi":"10.1109/ICEPE-ST.2011.6122960","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122960","url":null,"abstract":"For studying the effect of the pressure on the breaking performance during the cold gas interruption of a SF6 circuit breaker (CB), 1D compressive gas flow field mathematical model was deduced by replacing the mass equation with the pressure equation based on the mathematic transformation. And the distribution of Mach number in gas flow field under different opening strokes were simulated using finite volume method (FVM), and the density, the pressure, the velocity, and the temperature distribution of the gas flow were obtained and especially the above gas flow parameter variations at the region of the shock wave formed have been calculated. And the fundamental solution of the equations describing the gas flow in the SF6 CB has been resolved using separation of variables method, and 1D differential equations with constant coefficient were derived. Based on the proposed model, the bifurcation diagrams at different opening strokes have been calculated. The results show that for the gas flow with different velocity, the system exhibits periodic, quasi-periodic or even chaotic behavior in the arc quenching chamber. And the instability of the shock wave may be one of the origins of the complex phenomena.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"509 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122761627","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Compact switching technologies, state-of-art and future trends 紧凑型开关技术,最新技术和未来趋势
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122924
Hiroki Ito, H. Kohyama, D. Yoshida, T. Minagawa
{"title":"Compact switching technologies, state-of-art and future trends","authors":"Hiroki Ito, H. Kohyama, D. Yoshida, T. Minagawa","doi":"10.1109/ICEPE-ST.2011.6122924","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122924","url":null,"abstract":"The development of EHV and UHV substation equipment have been proceeding to cope with the electricity demand expansion due to economic growth in the world. Simultaneously, the requirements for substation equipment compactness, cost reduction and efficiency also have been emphasized in the competitive market. This paper introduces several examples of recent developments on the compact and reliable switching technologies. They include advanced diagnostic techniques based on field data for operation and maintenance, and monitoring and diagnostic systems, controlled switching supported by information technology with the latest sensor technology and information network.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130419076","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study on distributed digital simulation analysis system of aerospace electromagnetic relay based on Ethernet network 基于以太网的航天电磁继电器分布式数字仿真分析系统研究
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6123017
Wenying Yang, G. Zhai
{"title":"Study on distributed digital simulation analysis system of aerospace electromagnetic relay based on Ethernet network","authors":"Wenying Yang, G. Zhai","doi":"10.1109/ICEPE-ST.2011.6123017","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6123017","url":null,"abstract":"The design of aerospace electromagnetic relay is complicated and the process refers to the multi-fields problem including the kinematic, electricity, magnet and thermal. Aim to the problem, a new modeling language named RML and a distributed simulation method were proposed for the design of the aerospace electromagnetic relay. Through the secondary development of the related software, such as FLUX, ANSYS, ADAMS et al., the model of the relay built by RML could be recognized by any software above. The integrated simulation system of the aerospace electromagnetic relay was developed by the C++ Builder software. The system has the functions of the parameter design and kinematic analysis. The design and analysis of the relay are simplified for a certain extent when the system in the paper was adopted. The research in the paper is useful for the design of the digital analysis system of the other similar type switch apparatus.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121323954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Research and development of self-energy SF6 circuit breaker on the breaking capacity 自能SF6断路器分断能力的研究与开发
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6122949
Wen Gao, Wenbing Zhang, Ma Zhiying, W. Haibin, Peng Lei, Du Wenjuan, Jiao Qiuzhong
{"title":"Research and development of self-energy SF6 circuit breaker on the breaking capacity","authors":"Wen Gao, Wenbing Zhang, Ma Zhiying, W. Haibin, Peng Lei, Du Wenjuan, Jiao Qiuzhong","doi":"10.1109/ICEPE-ST.2011.6122949","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6122949","url":null,"abstract":"By improving of the dielectric performance between the breakers, medium condition and arc extinguishing ability, the breaking capacity of circuit breaker is increased. The main architecture of the 252kV circuit breaker is determined in which double chamber of interrupter construction + dual-direction moving of contacts mode are introduced. The key structure design parameter have been optimized combined with the design experiences of the finalized product: The volume of thermal expand chamber and puffer chamber as well as the cooperation between them are determined which ensures the breaking of the high current. Electric field analysis software is used to calculate, analyze and optimize the electric field strength of the circuit breaker contacts in some sensitive positions. Improving airflow channel for the decrease of the gas density is to be restrained and the hot gas exhaust efficiency is to be increased. As a result, the medium condition is improved. All the test verification has achieved for the researched and developed circuit breaker, and the product have been on stream. In the meantime, it provides the new technical foundation for the various following switchgears.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130326866","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study on SF6 gas decomposition products of typical GIS defect models by infrared detection 基于红外检测的典型GIS缺陷模型SF6气体分解产物研究
2011 1st International Conference on Electric Power Equipment - Switching Technology Pub Date : 2011-10-01 DOI: 10.1109/ICEPE-ST.2011.6123038
Wang Yuanyuan, Wei-Wei Ning, Ji Shengchang, Ding Weidong, Ma Kui
{"title":"Study on SF6 gas decomposition products of typical GIS defect models by infrared detection","authors":"Wang Yuanyuan, Wei-Wei Ning, Ji Shengchang, Ding Weidong, Ma Kui","doi":"10.1109/ICEPE-ST.2011.6123038","DOIUrl":"https://doi.org/10.1109/ICEPE-ST.2011.6123038","url":null,"abstract":"Detection of SF6 gas decomposition products has been increasingly used for monitoring the insulation condition of Gas Insulated Substation (GIS) for its advantages, comparing to traditional partial discharge detection methods, such as excellent anti-interference ability, explicit calibrating method and so on. In this paper, based on the setup of two typical GIS defect models including needle-to-plate and insulator surface, gas decomposition products were detected by IRprestige-21 Fourier transform infrared (FTIR) spectrophotometer. Types, concentrations and trends of typical gas decomposition products were analyzed. Moreover, influences of acquisition and transportation duration on detection results were studied. Obvious differences were found among infrared spectra of gas decomposition products from different defect models, which verifies the feasibility of IR gas decomposition detection method for GIS fault detection and diagnosis.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134024648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信