2015 9th International Conference on Sensing Technology (ICST)最新文献

筛选
英文 中文
Printed electronics: Present and future opportunities 印刷电子:现在和未来的机会
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438427
A. Nag, A. I. Zia, A. Babu, S. Mukhopadhyay
{"title":"Printed electronics: Present and future opportunities","authors":"A. Nag, A. I. Zia, A. Babu, S. Mukhopadhyay","doi":"10.1109/ICSENST.2015.7438427","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438427","url":null,"abstract":"The world had faced a leap in the field of science and technology to a great extent in the last five decades. The fabrication of materials is done in a more miniaturized way for merging the different aspects of the working field in a single device. The paper presents a review of different technologies that had been used electronically for the last two decades for the production of substances that are used in the field of electronics, electrical and biochemistry. The review includes the development of nanoparticles, biosensors and other small scaled devices for practical applications like detection of bacteria and other pathogens. The paper also describes the process of ink-jet printing that had been used since its introduction and gives a few methods for making stable conductive compounds like silver, copper in room temperature.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123563217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Multi-point hydrogen detection using SPR-based hetero-core structured hydrogen tip sensors and time domain interrogating system by PNCR 基于spr的异核结构氢尖传感器和PNCR时域询问系统的多点氢探测
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438500
A. Hosoki, M. Nishiyama, Kazuhiro Watanabe, H. Igawa
{"title":"Multi-point hydrogen detection using SPR-based hetero-core structured hydrogen tip sensors and time domain interrogating system by PNCR","authors":"A. Hosoki, M. Nishiyama, Kazuhiro Watanabe, H. Igawa","doi":"10.1109/ICSENST.2015.7438500","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438500","url":null,"abstract":"In this paper, the multi-point hydrogen detection system has been presented using the hetero-core optical fiber hydrogen tip sensor based on surface plasmon resonance (SPR) and time domain interrogating system based on Pseudorandom Noise code correlation reflectometry (PNCR) This method makes use of the correlation between a launched pseudorandom noise code signal and its reflection, can obtain a high signal to noise ration. A hetero-core optical fiber SPR hydrogen tip sensor consists of multilayer films of 25 nm Au/60 nm Ta2O5/5 nm Pd, coated onto a cylindrical cladding surface. The SPR resonant wavelength is shifted 17 nm for 4% hydrogen concentration in nitrogen. In addition, multi-point hydrogen detection is demonstrated using two SPR hydrogen tip sensors. All sensors have successfully detected the hydrogen concentration with real-time responses and sufficient sensitivities.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124802866","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Development of a multispectral imaging system for apple firmness prediction 苹果硬度预测多光谱成像系统的研制
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438390
Jason Sun, R. Künnemeyer, A. McGlone, P. Rowe, S. Talele
{"title":"Development of a multispectral imaging system for apple firmness prediction","authors":"Jason Sun, R. Künnemeyer, A. McGlone, P. Rowe, S. Talele","doi":"10.1109/ICSENST.2015.7438390","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438390","url":null,"abstract":"Multispectral imaging has been studied in recent years as a means of assessing fruit firmness. Here we report on the development of a static multispectral imaging system (MSI) that was used to validate the potential of the technique for high-speed commercial grading. The system consists of a high-performance CMOS camera, four lasers, electronically controlled shutters and a location control system. It captures four spectral scattering images on the fruit. In this study 100 `Royal Gala' apples have been measured using the static MSI. The MSI measurements were applied on the intact apple and also on a flat surface of internal flesh exposed by removing a thick skin slice. The scattering profiles were fitted with a standard light diffusion model and a heuristic modified Lorentzian model. The results showed that the correlations between penetrometer firmness and model parameters were poor, with the correlation coefficient, R, ranging from 0.4 to 0.8 in the best circumstance of the flat surface measurements. Although multivariate models can improve the correlations, this work suggests that laser scattering information on its own is not sufficient to predict the firmness.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129708051","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Improved detection limits for phthalates by selective solid-phase micro-extraction 选择性固相微萃取法提高邻苯二甲酸酯的检出限
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438493
A. I. Zia, Nasrin Afsarimanesh, Li Xie, A. Nag, I. Al-Bahadly, P. Yu, J. Kosel
{"title":"Improved detection limits for phthalates by selective solid-phase micro-extraction","authors":"A. I. Zia, Nasrin Afsarimanesh, Li Xie, A. Nag, I. Al-Bahadly, P. Yu, J. Kosel","doi":"10.1109/ICSENST.2015.7438493","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438493","url":null,"abstract":"Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128421208","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Analyzing Artificial Neural Networks and Dynamic Time Warping for spoken keyword recognition under transient noise conditions 瞬态噪声条件下语音关键字识别的人工神经网络和动态时间翘曲分析
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438406
P. López-Meyer, H. A. C. Maruri, Arturo Quinto-Martinez, Omesh Tickoo
{"title":"Analyzing Artificial Neural Networks and Dynamic Time Warping for spoken keyword recognition under transient noise conditions","authors":"P. López-Meyer, H. A. C. Maruri, Arturo Quinto-Martinez, Omesh Tickoo","doi":"10.1109/ICSENST.2015.7438406","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438406","url":null,"abstract":"Spoken keyword recognition has been under the spotlight for the past several decades, but has gained significant attention in recent years due to the rapid increase in front-end technology applications for mobile and wearable computing. This work presents the trade-off in performance between Artificial Neural Networks (ANN) and Dynamic Time Warping (DTW) methodologies, implemented for this task under three different transient noise conditions (inside a car, in a pub, and outdoors), where no external noise reduction pre-processing is used. For this purpose, two types of recognition models were implemented: speaker dependent (SD) and speaker independent (SI). Experimental results show comparable high keyword recognition precision in SD models for both ANN and DTW using baseline data, i.e. no transient noise, but for the SI models, a significant drop in precision was observed for the case of DTW. Additional precision analyses present the results on how the different types of transient noise affect the recognition methodologies of interest. From the point of view of storage resources, both methodologies require comparable memory usage for the SD models, however, the SI model increases the memory needed with the DTW methodology. Lastly, time performance analysis showed a faster recognition time using the ANN methodology.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129367401","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Time Domain Reflectometer for measuring liquid waste levels in a septic system 时域反射计,用于测量化粪池系统中的废液水平
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1007/978-3-319-47322-2_8
Shreya Reddy Mamidi, M. Haji-Sheikh, M. Kocanda, Donald Zinger, Mansour Taherinezahdi
{"title":"Time Domain Reflectometer for measuring liquid waste levels in a septic system","authors":"Shreya Reddy Mamidi, M. Haji-Sheikh, M. Kocanda, Donald Zinger, Mansour Taherinezahdi","doi":"10.1007/978-3-319-47322-2_8","DOIUrl":"https://doi.org/10.1007/978-3-319-47322-2_8","url":null,"abstract":"","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129290434","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Modeling of tri-axial accelerometers in a self-designed wearable inertial measurement unit 自行设计的可穿戴惯性测量装置中三轴加速度计的建模
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438470
H. Alqudah, X. Cui, Lin Ye, Kai Cao, J. Szymanski, Ying Guo, Steven W. Su
{"title":"Modeling of tri-axial accelerometers in a self-designed wearable inertial measurement unit","authors":"H. Alqudah, X. Cui, Lin Ye, Kai Cao, J. Szymanski, Ying Guo, Steven W. Su","doi":"10.1109/ICSENST.2015.7438470","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438470","url":null,"abstract":"This paper introduces a self-designed wearable inertial measurement unit (IMU-BMSJv2) and the calibration of its tri-axial accelerometers. We compare two popular accelerometer calibration approaches, the classical method (attitude dependent) and auto calibration method (attitude independent). Both these two calibration methods have been applied for the calibration of the self-designed IMU-BMSJv2; verification experiments have been carried out for the calibration of the tri-axial accelerometers. Experimental results show that although the auto-calibration method has the advantage of attitude independency, the classical calibration method can achieve better parameter estimation. We thus claim that the attitude dependent calibration method is still the first option considered when certain experimental conditions are satisfied.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131065174","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Automated bias-removal resistance measurement circuit for precision on-site temperature calibration exploitation of state changes of materials 利用材料状态变化进行精密现场温度校准的自动除偏电阻测量电路
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438398
Ciaran Doyle, D. Riordan, Joseph Walsh
{"title":"Automated bias-removal resistance measurement circuit for precision on-site temperature calibration exploitation of state changes of materials","authors":"Ciaran Doyle, D. Riordan, Joseph Walsh","doi":"10.1109/ICSENST.2015.7438398","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438398","url":null,"abstract":"An innovative process is proposed for the calibration of thermometric devices, combining materials which change state at primary temperature calibration points defined in international standards, and electrical impedance measurement techniques. The process will use pure samples of such materials and a measurement apparatus which enables the automated matching of the elimination of measurement bias to each of a number of calibration points, improving resolution and accuracy. The proposed process will be low-cost to allow implementation and regular calibration of temperature sensing and controlled devices in a standard manufacturing process.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132889747","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Development of a monitoring system for honeybee activities 蜜蜂活动监测系统的开发
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438495
Wei-Sheng Chen, Chien-Hao Wang, Joe-Air Jiang, En-Cheng Yang
{"title":"Development of a monitoring system for honeybee activities","authors":"Wei-Sheng Chen, Chien-Hao Wang, Joe-Air Jiang, En-Cheng Yang","doi":"10.1109/ICSENST.2015.7438495","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438495","url":null,"abstract":"This research develops a honeybee behavior monitoring system. The proposed system monitors honeybees' daily activities of getting in and coming out their beehive. It provides a new way to observe honeybee behavior and replace the methods of human observation. Specifically, it automatically records environmental parameters near and in the beehive. The information collected by the system is used for statistical analysis, and the analyzed results help researchers have a better understanding of the relationship between the environmental factors and honeybees' activities of getting in and coming out of their beehive. The research results show that the proposed system is beneficial to future research projects involving large scale monitoring of bee colony activities.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130991527","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Hydrogen sensing performance of an electrophoretic deposition (EPD) based Pd/GaN Schottky diode 电泳沉积(EPD)基Pd/GaN肖特基二极管的氢传感性能
2015 9th International Conference on Sensing Technology (ICST) Pub Date : 2015-12-01 DOI: 10.1109/ICSENST.2015.7438422
Wei-Cheng Chen, Huey-Ing Chen, Po-Cheng Chou, Ching-Hong Chang, Yung-Jen Chiou, Wen-Chau Liu
{"title":"Hydrogen sensing performance of an electrophoretic deposition (EPD) based Pd/GaN Schottky diode","authors":"Wei-Cheng Chen, Huey-Ing Chen, Po-Cheng Chou, Ching-Hong Chang, Yung-Jen Chiou, Wen-Chau Liu","doi":"10.1109/ICSENST.2015.7438422","DOIUrl":"https://doi.org/10.1109/ICSENST.2015.7438422","url":null,"abstract":"In this work, an interesting Pd/GaN Schottky diode-type hydrogen sensor, prepared by electrophoretic deposition (EPD) method, is fabricated and investigated. The studied device shows a high sensing response of 6.67×10<sup>4</sup> when exposing to a 1% H<sub>2</sub>/air gas at 100°C, and also detect even as low as 50 ppm H<sub>2</sub>/air gas. Moreover the studied device shows short response time and recovery time as 10 and 82 s, respectively, when exposing to a 1% H<sub>2</sub>/air gas at 150°C. Based on these excellent properties, the studied device gives a promise for high-performance hydrogen sensing applications.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"247 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123261903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信