Journal of Advanced Research in Fluid Mechanics and Thermal Sciences最新文献

筛选
英文 中文
Investigating the Effects of Air Bubbles Injection Technique on the Cooling Time of Warm Drinking Water 研究气泡注入技术对饮用温水冷却时间的影响
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-16 DOI: 10.37934/arfmts.119.1.164174
Kareem Jafar Alwan, Ali Jaber Talib, Nawfel Muhammed Baqer Muhsin, Ali Shakir Baqir, Hameed Balacem Mahood
{"title":"Investigating the Effects of Air Bubbles Injection Technique on the Cooling Time of Warm Drinking Water","authors":"Kareem Jafar Alwan, Ali Jaber Talib, Nawfel Muhammed Baqer Muhsin, Ali Shakir Baqir, Hameed Balacem Mahood","doi":"10.37934/arfmts.119.1.164174","DOIUrl":"https://doi.org/10.37934/arfmts.119.1.164174","url":null,"abstract":"This paper deliberates experimentally the inspiration of capacity flow rate of air bubbles inserted on the time period of a water cooler container with 30 liters of regular water initially at 37 °C. Four various volume flow rates of the injected air were used in the experiments (Qa=0.5; 1.0; 1.5 and 2.0 LPM). The air was injected into the water basin from the bottom as small air bubbles with an average diameter of (0.1 mm) via a spiral sparger made of silicon tube with (1400) holes and 0.1 mm hole diameter. In addition, four air pressures (P=2, 3, 4, and 5 bar) were used in the experiments. Consequences exhibited that the time required to cool down the water temperature (about 5 °C) was much smaller with injecting air bubbles than that of without injecting air bubbles (using the traditional cooling method). This consequence was more pronounced with amassed the volume airstream of the inserted air bubbles. The escalation the air volume flow rate, the quicker reduction the water cooling. Also, it was found that the pressure of the injected air bubbles had only a minor impact on the cooling process. Furthermore, the heat transfer and the cost of the cooling process with and without injecting air bubbles were studied. The heat transfer convection coefficient correlated of Nu was investigated to be increased with rising the volume flow rate of the injected air bubbles. Similarly, the cost of cooling down a specific amount of water was noticed to be decreased with increasing the injected air bubbles., The calculations illustrated that small air bubbles motility amount have a very significant guidance on time. The possibility of reaching the end of the cooling process can be achieved quicker as air flow rate amount is increased. It was clear how much electricity is saved using air bubble inoculation technique.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141831784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Exploration of Timber Dry and Wet Rot Defects in Buildings: Types, Causes, Effects and Mitigation Methods 探讨建筑物中的木材干腐和湿腐缺陷:类型、原因、影响和缓解方法
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-16 DOI: 10.37934/arfmts.119.1.196217
Rozaidi Arsyad Mahalil, Md Azree Othuman Mydin, R. Omar
{"title":"Exploration of Timber Dry and Wet Rot Defects in Buildings: Types, Causes, Effects and Mitigation Methods","authors":"Rozaidi Arsyad Mahalil, Md Azree Othuman Mydin, R. Omar","doi":"10.37934/arfmts.119.1.196217","DOIUrl":"https://doi.org/10.37934/arfmts.119.1.196217","url":null,"abstract":"The present study is an appraisal of dry and wet rot defects and their effects on structural and non-structural elements. There were three main objectives to be achieved which were to determine the main causes that lead to wet and dry rot defects in structural and non-structural elements of the building, to establish the effects of wet and dry rot defects on the structural and non-structural elements of the building and lastly to recommend approaches and techniques for repairing wet and dry rot flaws on building structural and non-structural elements. Various study methodologies were utilised, including thorough literature review, case study analysis, and interviews with subject matter experts. The study revealed that timber houses can possess notable flaws in both their structural and non-structural components, which can have adverse effects on its materials and environment. These problems can result in diminished comfort levels, health concerns, and potential risks to the occupants' lives. Dry rot mostly impacts timber components, resulting in significant harm and compromising the structural integrity. Wet rot is a type of decay that happens in moist environments and can impact a broader variety of materials. Moreover, it is essential to implement proactive maintenance and repair methods to mitigate the risks connected with rot. Some recommendations include implementing effective moisture management systems, conducting frequent inspections to detect deterioration early, and promptly responding to any evidence of decay by completing targeted repairs or replacements.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141831706","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An Experimental Study using Diesel Additives to Examine the Combustion and Exhaust Emissions of CI Engines 使用柴油添加剂检测 CI 发动机燃烧和废气排放的实验研究
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-16 DOI: 10.37934/arfmts.119.1.6779
K. Nasir, Maher Faris, Sa'ib, Abbas Hamid Aljubury, R. Zulkifli
{"title":"An Experimental Study using Diesel Additives to Examine the Combustion and Exhaust Emissions of CI Engines","authors":"K. Nasir, Maher Faris, Sa'ib, Abbas Hamid Aljubury, R. Zulkifli","doi":"10.37934/arfmts.119.1.6779","DOIUrl":"https://doi.org/10.37934/arfmts.119.1.6779","url":null,"abstract":"A single-cylinder diesel engine is used for an experimental inquiry utilizing diesel fuel (Di) and two different improver types: diethyl ether (DE) and bael oil (BO). The purpose of this research is to enhance fuel quality for improved engine efficiency in reduced emissions from engines by using diethyl ether and Bael oil. The fuel's cetane number was tested after 15% bael oil and 10% diethyl ether were added to commercial diesel. In order to assess engine performance and emissions, engine tests were conducted with the three fuels at progressively higher speeds, without load, and in the 1000–2500 RPM range with 250 RPM steps. The study's findings indicate that using diethyl ether and bael oil, respectively, improved the fuel cetane number from 48 to 52 and 54. Additionally, a notable rise in engine efficiency by 9.9% and 17.6% and a notable increase in engine brake power by approximately 15.9% and 26.8%, respectively, had been observed for the entire engine speed. At low and medium engine speeds, there was a notable decrease in specific fuel consumption of 19.7% and 36.6%, respectively. Furthermore, compared to commercial diesel, a discernible decrease in emissions has been noted for CO of 15.3% and 29.8%, CO2 of 9.2% and 24.2%, and HC of 13% and 24.4%, respectively. Thus, it can be concluded that if you want to improve engine performance and lower exhaust emissions, you can use diethyl ether as a fuel additive with commercial diesel.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141832351","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analyzing the Impact of Droplet Impingement Interval on Biodiesel Deposition Characteristics 分析液滴撞击间隔对生物柴油沉积特性的影响
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-16 DOI: 10.37934/arfmts.119.1.4253
F. Jikol, Mohd Zaid, Y. M. Arifin, Mohd Azli Salim, S. Herawan
{"title":"Analyzing the Impact of Droplet Impingement Interval on Biodiesel Deposition Characteristics","authors":"F. Jikol, Mohd Zaid, Y. M. Arifin, Mohd Azli Salim, S. Herawan","doi":"10.37934/arfmts.119.1.4253","DOIUrl":"https://doi.org/10.37934/arfmts.119.1.4253","url":null,"abstract":"The purpose of this work is to investigate the effect of droplet impingement interval on deposition characteristics of diesel fuel (DF) and palm oil biodiesel with different blending ratios (B10-B50) by applying the hot surface deposition test (HSDT). Generally, HSDT method is a simplified method to simulate fuel deposition in diesel engines by impinging fuel droplets on a heated aluminum alloy plate surface. The mass of accumulated deposits after droplets ND=16000 for impingement interval of timp=7 seconds (dry condition) MR=3.7mg (DF), MR=3.9mg (B10), MR=17.1mg (B20), MR=24.0mg (B30), MR=25.1mg (B40), and MR=28.8mg (B50). For impingement interval of timp=3 seconds (wet condition), the deposit mass was MR=4.4mg (DF), MR=8.9mg (B10), MR=20.4mg (B20), MR=31.1mg (B30), MR=62.4mg (B40), and MR=58.2mg (B50). In terms of deposit surface temperature, the recorded average minimum and maximum deposit surface temperatures were between Td=295°C to Td=325°C (timp=7 seconds) and Td=200°C to Td=300°C (timp=3 seconds) for DF. For B10-B50, the deposit surface temperatures were around Td=290°C to Td=350°C (timp=7 seconds) and below Td=200°C for impingement interval of timp=3 seconds.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141832583","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fluid-Structure Interaction Modelling of Blood Flow in Peripheral Arterial Disease 外周动脉疾病血流的流体-结构相互作用模型
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-16 DOI: 10.37934/arfmts.119.1.117133
Muhammad Firdaus Mohd Fauzi, Nasrul Hadi Johari, Mohd Jamil Mohamed Mokhtarudin, Bazli Mohd Yusoff, Baolei Guo
{"title":"Fluid-Structure Interaction Modelling of Blood Flow in Peripheral Arterial Disease","authors":"Muhammad Firdaus Mohd Fauzi, Nasrul Hadi Johari, Mohd Jamil Mohamed Mokhtarudin, Bazli Mohd Yusoff, Baolei Guo","doi":"10.37934/arfmts.119.1.117133","DOIUrl":"https://doi.org/10.37934/arfmts.119.1.117133","url":null,"abstract":"The study presents the fluid-structure interaction (FSI) modeling in Peripheral Arterial Disease (PAD) geometry, highlighting the effects of arterial blockage on hemodynamics and arterial wall mechanics. Employing a RANS-based SST-Tran model, the study examines stenotic PAD models under realistic boundary conditions, coupled with a hyperelastic Mooney-Rivlin model to simulate the arterial wall's response. The analysis includes velocity profiles, wall shear stress (WSS), pressure distribution, and wall displacement, revealing significant differences between healthy and stenosed models. It demonstrates adaptive hemodynamics, the impact of stenosis on flow mechanics, and potential implications for atherosclerosis and plaque formation. The findings highlight the importance of understanding stenosis severity for clinical risk assessment, treatment planning, and monitoring.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141832091","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Statistical Analysis of Wind Resource Assessment for Different Locations in South-Western Thailand 泰国西南部不同地点风资源评估的统计分析
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-04 DOI: 10.37934/arfmts.118.2.87100
Attapon Chumapan, Paramin Neranon, Juntakan Taweekun
{"title":"Statistical Analysis of Wind Resource Assessment for Different Locations in South-Western Thailand","authors":"Attapon Chumapan, Paramin Neranon, Juntakan Taweekun","doi":"10.37934/arfmts.118.2.87100","DOIUrl":"https://doi.org/10.37934/arfmts.118.2.87100","url":null,"abstract":"Weibull parameters have been widely used to evaluate wind energy potential. In this work presents wind resource assessment by statistical analysis with a Weibull distribution model for Krabi, Phuket, and Ranong weather stations in south-western Thailand. Ten-minute intervals include wind speed and wind direction of 10m from four-year records obtained by the Thai meteorological department. Four numerical methods, namely empirical method, graphical method, energy pattern factor method and maximum likelihood method are examined to estimate the Weibull parameters. The Weibull distribution obtained from each method is compared with the observed wind speed distribution by the performance tests using root mean square error, mean percentage error, and chi-square error to select a suitable method for the station area. The results revealed that the maximum likelihood method was the most accurate for Krabi and Phuket stations, and the energy pattern factor method was the most accurate for Ranong station. At a hub height of 80m, the highest mean wind speed and mean wind power density found in Krabi station were 3.25 m/s and 44.84 W/m2. The most probable wind speed value in three stations had a range from 1.80 to 2.50 m/s. The maximum wind speed carrying maximum energy found in Krabi station was 5.53 m/s. The operating probability of a wind turbine in Krabi station was 49.61%, followed by Phuket station was 46.80%, and Ranong station was 37.84%, respectively. In conclusion, all three stations had wind power potential classified as wind class 1 and can be sorted as follows: Krabi, Phuket, and Ranong stations.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141678796","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mechanical and Thermal Properties of 3D-Printed Acrylonitrile Butadiene Styrene Reinforced with Rubberwood Fiber 用橡胶木纤维增强的三维打印丙烯腈-丁二烯-苯乙烯的机械性能和热性能
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-04 DOI: 10.37934/arfmts.118.2.7486
Thanate Ratanawilai, Noppanat Jaturonlux, Anas Awae, Warinthon Muangnivet, Zaleha Mustafa
{"title":"Mechanical and Thermal Properties of 3D-Printed Acrylonitrile Butadiene Styrene Reinforced with Rubberwood Fiber","authors":"Thanate Ratanawilai, Noppanat Jaturonlux, Anas Awae, Warinthon Muangnivet, Zaleha Mustafa","doi":"10.37934/arfmts.118.2.7486","DOIUrl":"https://doi.org/10.37934/arfmts.118.2.7486","url":null,"abstract":"An additive manufacturing (AM) has become very popular due to its simplicity in producing complicated products using just one process due to the layer-by-layer addition of material, which makes it possible for more complicated products to be created. The constraint of Fused Filament Fabrication (FFF) printed components with inadequate mechanical qualities has prevented AM from being widely adopted by numerous industries. The mechanical and thermal qualities of FFF printed components which is a pure polymer could be enhanced by reinforcing the wood fiber into the polymer. In this study, the twin-screw extruder was used to produce the wood plastic composites (WPCs) filaments, which were made with ABS (Acrylonitrile Butadiene Styrene) as the matrix material and 1-3wt% rubberwood fiber (RWF) for reinforcement. The effects of the extrusion parameter, such as the volume fraction of RWF and the temperature of the extrusion process, on the 3D-printed WPCs samples were investigated. The experimental results of 3D-printed WPC sample were found that the highest compressive strength value is 24.3 MPa, obtained from the rubberwood 1wt% at the extrusion temperature 218 °C whereas the pure ABS filaments obtaining from the commercial and extrusion process gave the values of 28.9 and 14.5 MPa, respectively. The highest value of tensile strength is 8.4 MPa with the rubberwood 2wt% and temperature 198 °C whereas the pure ABS filaments obtaining from the commercial and extrusion process gave the values of 10.9 and 7.4 MPa, respectively. The morphological analysis of the 3D-printed WPC sample was observed to exhibit an effect of printing process. The result showed that an increasing temperature of extrusion process increases both tensile and compressive strengths of the samples whereas an increasing amount of fiber increases the tensile strength but decreased the compressive strength. Analysis of variance demonstrated linear factor and 2-way interaction factor of the extrusion parameter influence on compression and tensile strength significantly. The rubberwood 2wt% and the temperature 218 °C was suggested to achieve the suitable condition for extrusion process for the 3D-printed WPC sample. In addition, the discussions were supported with the thermal properties achieved from Thermogravimetric analysis and Differential Scanning Calorimetry.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141677496","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Optimization of Chillers Air-Conditioning in Thailand Supermarkets using a Retail Energy Management System (REMS) 利用零售能源管理系统(REMS)优化泰国超市的冷风机空调系统
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-04 DOI: 10.37934/arfmts.118.2.6273
Piyanut Saengsikhiao, Chayapat Prapaipornlert, Juntakan Taweekun
{"title":"The Optimization of Chillers Air-Conditioning in Thailand Supermarkets using a Retail Energy Management System (REMS)","authors":"Piyanut Saengsikhiao, Chayapat Prapaipornlert, Juntakan Taweekun","doi":"10.37934/arfmts.118.2.6273","DOIUrl":"https://doi.org/10.37934/arfmts.118.2.6273","url":null,"abstract":"Supermarkets in Thailand continue to grow and there will be more than 1500 branches by 2023 open 18-24 hours a day. In this research, we will present how to increase energy efficiency in retail stores by reducing the energy consumption of compressors of chiller air conditioning systems by using energy management systems in retail stores. Retail energy management systems in retail stores use the Internet of Things to connect to a device to store data and analyze and process from big data, then Artificial Intelligence controls and commands to make the air conditioning system energy efficient. Controlling 10 AHUs using central sensors at the sales area instead of return sensors allows us to save 25% of energy or 12,886 kWh/Year. As for the cold-water pump, it is controlled by an inverter. By using sensors to measure the water flow rate, we save 33% of energy or 19,755 kWh/Year. When controlling the water pump and AHU, the chiller compressor will save energy because when the air handling unit and the water pump have reduced work, the work of the compressor to cool water is reduced as well, resulting in energy savings of 12% or 25,211 kWh/Day. Using such a system reduces the overall energy consumption of the chiller air conditioning system. 17% or 57,852 per year has a payback period of 3 years and can also be extended to other systems within the store or other stores.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141680291","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Influence of Varying Ar/O2 Gas Ratio with Catalyst-Free Growth by Homemade Thermal Evaporation Technique 自制热蒸发技术中不同氩气/氧气比对无催化剂生长的影响
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-04 DOI: 10.37934/arfmts.118.2.101113
Azira Khairudin, Najiha Hamid, Syahida Suhaimi, Mohd Ikmar Nizam Mohamad Isa, Nur Athirah Mohd Taib, Syamsul Kamar Muhamad @ Wahab
{"title":"The Influence of Varying Ar/O2 Gas Ratio with Catalyst-Free Growth by Homemade Thermal Evaporation Technique","authors":"Azira Khairudin, Najiha Hamid, Syahida Suhaimi, Mohd Ikmar Nizam Mohamad Isa, Nur Athirah Mohd Taib, Syamsul Kamar Muhamad @ Wahab","doi":"10.37934/arfmts.118.2.101113","DOIUrl":"https://doi.org/10.37934/arfmts.118.2.101113","url":null,"abstract":"A nanostructured zinc oxide (ZnO) with different percentages of argon and oxygen gas flow rate was deposited on a silicon wafer by a simple hot tube thermal evaporation technique. The effect of different percentages of gas flow rate on the crystal structure, surface morphology and optical properties were characterized using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), energy dispersive X-ray (EDX) and RAMAN spectroscopy, respectively. The changes of morphologies from FESEM were significant where the grown ZnO nanostructures show three different shapes which are nanotripods, nanoclusters and nanorods at 5%, 10% and 25% of oxygen gas, respectively. EDX results revealed that Zn and O elements have a major percentage in the sample indicating a composition has high purity of ZnO. XRD patterns displayed the most intense diffraction peak of ZnO at (101), which exhibited a single crystalline hexagonal structure with preferred growth orientation in the c-axis. RAMAN scattering study found that synthesized ZnO shows the high intensity of E2 mode and low intensity of E1 mode attributed to all the samples having good crystal quality containing fewer structural defects. In conclusion, the E15 sample with a 25% oxygen gas flow rate was selected as an optimum result for synthesizing a homogenous surface and high crystallinity of ZnO by using a hot tube thermal evaporation process. This work can enhance the development of ZnO production in various applications.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141678285","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Predictive Placement of IC Chips using ANN-GA Approach for Efficient Thermal Cooling 利用 ANN-GA 方法预测集成电路芯片的放置位置以实现高效散热
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Pub Date : 2024-07-04 DOI: 10.37934/arfmts.118.2.137147
Anant Sidhappa Kurhade, Ramdas Biradar, Rahul Shivaji Yadav, Prashant Patil, Nitin Babanrao Kardekar, Shital Yashwant Waware, Kashinath Haribhau Munde, Ajitkumar Gulab Nimbalkar, Govindarajan Murali
{"title":"Predictive Placement of IC Chips using ANN-GA Approach for Efficient Thermal Cooling","authors":"Anant Sidhappa Kurhade, Ramdas Biradar, Rahul Shivaji Yadav, Prashant Patil, Nitin Babanrao Kardekar, Shital Yashwant Waware, Kashinath Haribhau Munde, Ajitkumar Gulab Nimbalkar, Govindarajan Murali","doi":"10.37934/arfmts.118.2.137147","DOIUrl":"https://doi.org/10.37934/arfmts.118.2.137147","url":null,"abstract":"In this research, numerical modelling is used to explore the heat transfer through natural convection capabilities of nine aluminum integrated circuit chips that are installed on substrate board. The goal is to figure out where on the substrate board these IC chips would be best placed if they were arranged differently. The dimensionless parameter (λ) plays a very essential role, and by applying a hybrid technique consisting of ANN and GA. ANSYS Icepack calculates IC chip temperature distributions in 3D steady state numerical simulations. It has been shown that the form, dimensions, and IC chips' substrate board positioning affects their operating temperature. In comparison to the strategies that have been used in the past, hybrid optimization is the strategy that has shown to be the most reliable in properly predicting how the IC chips would be arranged on the substrate board. It has been observed that higher values of one of these parameters lead to a reduction in the maximum temperature surplus. A correlation has been established to illustrate this relationship as it increases. The most favorable simulation outcomes are utilized to drive a genetic algorithm (GA), which identifies the optimal configuration ensuring that the temperatures of the heat sources remain well below their specified maximum operating conditions, as outlined in the data sheets. The maximum temperature variation between the lowest and highest extreme configurations ranges between 4 - 8%. The smallest size IC chip, U2 with high heat dissipation rate attains the maximum temperature in the configuration, however, the temperature variation for the low powered IC chips U3, U4 and U7 are very small. Found good agreement of both the data with an error band of 10%, and thus confirms the accuracy of the network.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141679150","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信