{"title":"A Short Overview of Active-Clamped Resonant DC Link Inverter","authors":"Darko Vracar","doi":"10.1109/INDEL50386.2020.9266172","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266172","url":null,"abstract":"In this manuscript an extended mathematical model of a three-phase actively-clamped resonant dc link inverter is shown. The control approach based on usage of the analog sigma-delta modulator with prediction of resonant dc link current is explained in detail. The inverter operation under resistive, inductive and capacitive load is examined by simulations. It is shown that inverter can work with all types of loads under zero-voltage switching circumstances even when having resonant-current reversals and with low modulation index.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130907200","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"[INDEL 2020 Copyright notice]","authors":"","doi":"10.1109/indel50386.2020.9266236","DOIUrl":"https://doi.org/10.1109/indel50386.2020.9266236","url":null,"abstract":"","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"126 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122527060","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Simple Circuit to Visualize Space Vectors by an Oscilloscope","authors":"P. Pejovic","doi":"10.1109/INDEL50386.2020.9266170","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266170","url":null,"abstract":"The paper presents a simple circuit for analog computation of space vector components on the basis of phase voltages. The space vector trajectory could be directly visualized by an oscilloscope. Proposed circuit consists of nine resistors only. An algorithm to compute the resistor values and programs that support the design are provided. The method is experimentally verified using a three-phase voltage source inverter model. Three methods to visualize recorded data are proposed, each capturing different aspect of the space vector trajectory.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117281221","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
O. Dvornikov, V. Tchekhovski, N. Prokopenko, A. Titov
{"title":"Comparison of Fast Response and Noise of Charge-Sensitive Amplifiers with Various Types of Input Fets","authors":"O. Dvornikov, V. Tchekhovski, N. Prokopenko, A. Titov","doi":"10.1109/INDEL50386.2020.9266185","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266185","url":null,"abstract":"The circuit simulation results of the charge-sensitive amplifiers (CSA) with various types of input field-effect transistors (FET) are considered. CSA-1 and CSA-2 are implemented on Si bipolar transistors, besides in CSA-1 the input transistor is a Si field-effect transistor with p-n junction (Junction Field Effect Transistor, JFET) and in CSA-2 - a GaAs FET with a gate formed by Schottky contact (metalized semiconductor FET, MESFET). CSA-3 is developed completely on the GaAs MESFET. In order to adequately compare the CSAs with respect to the rise-time τ of the output pulses and the equivalent noise charge (ENC), all input transistors were selected with approximately equal drain current and the ratio of the gate width to the length W/L. The electrical circuits of the CSAs, the simulation results of the operating mode, the critical parameters, the dependence of τ and the ENC on the capacity of the input signal source CD are presented.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129180404","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E. Musić, Vladimir Milojevic, Srdan Calija, D. Jokić
{"title":"Development of a traceable reference system for measurement of power and power quality","authors":"E. Musić, Vladimir Milojevic, Srdan Calija, D. Jokić","doi":"10.1109/INDEL50386.2020.9266278","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266278","url":null,"abstract":"Quality of measurement results and their accuracy in not neccessary to be high in conventional systems, approximate results are enough to know exactly what happens in the system. However, with increased penetration of renewable sources in the grid, need for high quality and precise measurements has risen. In order to have precise information about power quality, good knowledge of the behaviour of power quality analyzers is needed. Good knowledge can only be obtained by calibration of those meters. This paper describes start of development of a fully traceable power quality reference setup for the calibration of power quality analyzers based on digital sampling of voltage/current signals, and shown preliminary results.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"124 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127412564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Popovic, B. Vujkov, Mladen Vučković, V. Vasic, D. Marčetić, Đura Oros
{"title":"MAPT strategy for IPMSM with parameter sensitivity analysis","authors":"V. Popovic, B. Vujkov, Mladen Vučković, V. Vasic, D. Marčetić, Đura Oros","doi":"10.1109/INDEL50386.2020.9266282","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266282","url":null,"abstract":"In this paper, minimum ampere per torque strategy of interior permanent magnet synchronous machine in low voltage drive application is presented. The general optimization function is derived, with neglected the iron losses. Furthermore, the optimal dq currents were calculated. The presented mathematical and obtained optimal currents were further used to perform computational simulations. Two sets of simulations were performed in order to present the parameter sensitivity of minimum ampere per torque strategy. The main focus of the research was a variation of the two most important parameters, direct and quadrature inductances and their impact on the proposed strategy.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131864344","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance analysis of the speed servomechanism with the adaptive PI controller","authors":"I. Krcmar, P. Matić, D. Marčetić, P. Maric","doi":"10.1109/INDEL50386.2020.9266250","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266250","url":null,"abstract":"An adaptive proportional and integral controller for digital speed control in electrical drives is derived and analysed. Adaptation of the controller parameter is gradient descent procedure. The adaptive controller is derived from the discrete-time model of a digitally controlled speed servomechanism. Discrete-time model is obtained from the Z-transforms of the system signals and elements. Applied controller has distributed structure, i.e. integral action is placed in the direct path, while proportional action is positioned in the feedback path of the system. Thus, it provides improved system accuracy, while it maintains sufficient level of system relative stability. Due to presence of feedback in the system and controller structures, gradient of criterion function is computed through a recurrent procedure. Performance analysis of the speed servo-mechanism with the adaptive proportional and integral controller is performed in complex domain, using root locus techniques. The analysis indicates controller parameter influence on the system stability and reference tracking capability. Further, it shows that the adaptive controller yields zero steady state error and step disturbance rejection, as well as good system performance in the presence of modelling errors. Experiments, performed as reference tracking tasks, support the analysis.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"170 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124740398","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Half-Bridge LLC Converter: Design Notes and Simulation Challenges in PLECS","authors":"Darko Vracar","doi":"10.1109/INDEL50386.2020.9266133","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266133","url":null,"abstract":"In this paper the design notes for a half-bridge LLC dc-dc converter and simulation challenges in software PLECS are presented. The given design notes were targeted at readers who do not have previous experience with the LLC converter. The PLCES simulation challenges were: how to simply model specific analog control IC for closed-loop operation and how to provide the \"switching frequency vs. time\" waveforms. Key to solution of the first challenge was to model only the VCO section and minimum needed IC pins so that one could execute closed-loop simulations. This approach was verified by simulation of the 600 W half-bridge LLC converter. In addition, the \"frequency vs. time\" measurement block in PLECS was custom-made and, for the first time, measurements of \"switching frequency vs. time\" of a LLC converter were presented.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125464526","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Survey on Switched Reluctance Starter/Generator for the More Electric Aircraft","authors":"Nena Apostolidou, N. Papanikolaou, Michael Loupis","doi":"10.1109/INDEL50386.2020.9266164","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266164","url":null,"abstract":"This study summarizes the current state-of-the-art regarding the switched reluctance machine (SRM), as one of the most promising starter/generator (S/G) candidates to be aggregated in the high voltage (270 V or 540 V) DC distribution system of the more electric aircraft (MEA). The machine operational principles, its fundamental technical parameters regarding the specific application and the proposed control schemes are presented.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132208538","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An I-f Startup Method for Back-EMF based Sensorless FOC of PMSMs with Improved Stability During the Transition","authors":"Dunzhi Chen, K. Lu, Dong Wang","doi":"10.1109/INDEL50386.2020.9266266","DOIUrl":"https://doi.org/10.1109/INDEL50386.2020.9266266","url":null,"abstract":"The I-f control is often used as a startup method for back-EMF based sensorless field-oriented-control (FOC) of permanent magnet synchronous machines (PMSMs). In this hybrid control scheme, usually a large current magnitude is used for the I-f control to start the machine. After the machine reaches a certain speed when the position and speed estimations from the back-EMF based method are accurate enough, the control can be switched to FOC. To obtain a smooth transition, a popular method reported in the literature is reducing the current vector magnitude to move the current vector to the q-axis before the transition. However, the current reduction methods usually assume that load torque does not change during the process of reducing the current vector magnitude. In cases where the load torque changes, since the current vector magnitude cannot be increased automatically to reject the load disturbance, synchronism can be lost and the transition to FOC may fail. To achieve a smooth transition with improved stability during the transition process, this paper proposes an I-f startup method with compensation loops, which can move the current vector to the q-axis and fix it there even when load varies. Since the current vector is already on the q-axis in the I-f control mode, the switching to FOC is made very smooth. Experimental results verify the effectiveness of the proposed method.","PeriodicalId":369921,"journal":{"name":"2020 International Symposium on Industrial Electronics and Applications (INDEL)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130108339","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}