2009 International Conference on Power Systems最新文献

筛选
英文 中文
Design of pulsed power system for fusion reactor 核聚变反应堆脉冲动力系统设计
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442709
B. Srilatha, A. Sinha
{"title":"Design of pulsed power system for fusion reactor","authors":"B. Srilatha, A. Sinha","doi":"10.1109/ICPWS.2009.5442709","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442709","url":null,"abstract":"This Paper presents dynamic analysis of dc and ac excited flywheel generators for pulsed load of a fusion reactor. Simulations are carried out using PSCAD/EMTDC software and the performance of flywheel generator connected to the electricity grid under various operating conditions is analyzed and compared. The study is helpful in designing power system with flywheel energy storage.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"94 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131921000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
System planning and protection engineering - An overview 系统规划与保护工程—概述
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442705
Amit Jain, K. Garg
{"title":"System planning and protection engineering - An overview","authors":"Amit Jain, K. Garg","doi":"10.1109/ICPWS.2009.5442705","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442705","url":null,"abstract":"System planners are responsible for future planning of system and substation/protection engineers are responsible for the protection system and design. An engineer with an experience of both planning and protection can plan and design an adequate system and protection for the future. This paper aims to provide a comprehensive reference document to the practicing engineers, researchers, and academicians of fast growing developing countries about the system planning and protection engineering techniques and tools practiced in North American Power System, which is one of the largest and most advance power systems.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123882052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Lightning electromagnetic fields at different heights above the ground 地面上不同高度的闪电电磁场
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442745
K. Chandrasekaran, P. Durai Kannu
{"title":"Lightning electromagnetic fields at different heights above the ground","authors":"K. Chandrasekaran, P. Durai Kannu","doi":"10.1109/ICPWS.2009.5442745","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442745","url":null,"abstract":"This paper presents the computed results of electric and magnetic fields generated by the near by lightning. The electric and magnetic fields have been computed for different heights ranging from 10 m to 2 km above the ground and for the lateral distances varying from 20 m to 2 km from the lightning return stroke. For airborne vehicles e.g. satellite launch vehicles, missiles etc, it has become necessary to understand the behavior of these when illuminated by a strong electromagnetic fields generated by a near by lightning. The coupling of these fields with the above system could be by means of the leakage of the transient electromagnetic fields through the joints of the vehicles, leakage through the improperly shielded cables, leaks through the edges of closed doors etc. This results the generation of transient voltages and currents with the internal circuitry of such systems. The objective of this work is to compute the fields along the airborne vehicles when excited by plane electromagnetic fields. These plane electromagnetic fields consist of electric and magnetic fields, where the fields could get modified at different heights from the ground plane and for different distances from the lightning channel.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128298931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigation and modeling of epoxies aging tests under the effect of variation of parameters on partial discharge (PD) 参数变化对局部放电影响下环氧树脂老化试验的研究与建模
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442715
C. K. Vibhakar, S. Kanitkar
{"title":"Investigation and modeling of epoxies aging tests under the effect of variation of parameters on partial discharge (PD)","authors":"C. K. Vibhakar, S. Kanitkar","doi":"10.1109/ICPWS.2009.5442715","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442715","url":null,"abstract":"this paper is based on the investigations made by applying High Voltage (H. V.) ageing test on five different epoxy insulators under different voltage and temperature conditions. Also the effect of temperate is monitored for PD according to the IS: 11322-1985 manual and IOP publication 35 {IOP report publication 35(2002) 33–39} as a matter of investigation on material performance. Experiments are carried out on widely employed simple epoxy resin based high-voltage insulation electrode systems having a pin hole (cavity). Before placing epoxy insulator at high voltage assembly it is passed from x-ray unit to check the size of pin hole. Each insulator temperature is regulated from 30°C to 150°C inside thermal chamber during the experiment. On the basis of a previously performed analysis of the ageing mechanism in different solid insulating materials, simple phenomenological aging and life effects are proposed. This gives a new approach and new tool for the problem for future application on electrical components. The investigation and modeling of long term ageing test by studying the effect of parameters (i. e. temperature on PD and energy wasted in the epoxy during ageing) were assumed to be a stress function in the inverse power law.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128281464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Graph theory based corrective control strategy during single line contingency 基于图论的单线事故纠偏控制策略
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442671
M. K. Maharana, K. Swarup
{"title":"Graph theory based corrective control strategy during single line contingency","authors":"M. K. Maharana, K. Swarup","doi":"10.1109/ICPWS.2009.5442671","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442671","url":null,"abstract":"This paper presents a new Graph Theory based corrective control strategy to alleviate overloads of transmission lines, with the help of a local optimization concept. A Direct Acyclic Graph (DAG) technique for selection of participating generators and load buses with respect to a contingency is presented. Particle Swarm Optimization (PSO) technique has been employed for generator rescheduling and/or load shedding to the identified generators and loads, to bring back the system from abnormal to normal operating state. The effectiveness of the proposed approach is demonstrated for different contingency cases in IEEE 57 and modified IEEE 118 bus systems. The result shows that the proposed approach is computationally fast, reliable and efficient, in restoring the system to normal state after a contingency with minimal control actions.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128116974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Transient stability analysis using modified Euler's iterative technique 基于改进欧拉迭代法的暂态稳定分析
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442678
A. A. Nimje, C. Panigrahi
{"title":"Transient stability analysis using modified Euler's iterative technique","authors":"A. A. Nimje, C. Panigrahi","doi":"10.1109/ICPWS.2009.5442678","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442678","url":null,"abstract":"This paper presents a detailed analysis on transient stability in power system using modified Euler's iterative techniques. Transient stability studies are of prime importance while planning as well as control and operation of the system. To carry out the transient stability studies, the initial operating conditions of the system just before the disturbances should be known. All these initial conditions are obtained by load flow studies prior to the disturbances by proper load flow methods.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128711321","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Control of 4-Leg VSC based DSTATCOM using modified Instantaneous Symmetrical Component Theory 基于改进瞬时对称分量理论的四足VSC DSTATCOM控制
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442769
Sunil Kumar, Bhim Singh
{"title":"Control of 4-Leg VSC based DSTATCOM using modified Instantaneous Symmetrical Component Theory","authors":"Sunil Kumar, Bhim Singh","doi":"10.1109/ICPWS.2009.5442769","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442769","url":null,"abstract":"In this paper, a 4-leg VSC (voltage source converter) based DSTATCOM (Distribution Static Compensator) is used for the load compensation and neutral current compensation in 3-phase 4-wire distribution system. For extracting the reference source currents, Instantaneous Symmetrical Component Theory (ISCT) based control algorithm is modified for voltage regulation and used with indirect current control technique for controlling the DSTATCOM currents. The DSTATCOM is controlled for power factor correction and voltage regulation at PCC (point of common coupling). Simulations are performed for various load conditions such as a reactive linear load, an unbalanced load and a non-linear load in Power Factor Correction (PFC) mode and in Zero Voltage Regulation (ZVR) mode in MATLAB environment using SIMULINK and Sim Power System (SPS) toolbox.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128985714","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 27
Mitigation of detrimental subsynchronous oscillations by linear optimal control with prescribed degree of stability 用规定稳定度的线性最优控制减轻有害的次同步振荡
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442757
Iman Mohammad Hoseiny Naveh, E. Rakhshani
{"title":"Mitigation of detrimental subsynchronous oscillations by linear optimal control with prescribed degree of stability","authors":"Iman Mohammad Hoseiny Naveh, E. Rakhshani","doi":"10.1109/ICPWS.2009.5442757","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442757","url":null,"abstract":"In this paper, an innovative method is proposed to improve the performance of linear optimal control for mitigation of sub-synchronous resonance in power systems. This method is based on shifting eigenvalues of the state matrix of system to the left hand-side of s plane. It is found that this proposed controller is an extended state of linear optimal controller with prescribed degree of stability. A proposed design, which is presented in this paper, has been developed in order to control of severe sub-synchronous oscillations in a nearby turbine-generator. The proposed strategy is tested on second benchmark model and compared with the optimal full-state feedback method by means of simulation. It is shown that this method creates more suitable damping for these oscillations. The proposed method is applied to the IEEE Second Benchmark system for sub-synchronous resonance studies and the results are verified based on comparison with those obtained from digital computer simulation by MATLAB.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"1474 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120876637","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Direct model reference adaptive internal model controller for DFIG wind farms with dither injection 带有抖动注入的DFIG风电场直接模型参考自适应内模控制器
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442663
N. Amuthan, Shikha Singh
{"title":"Direct model reference adaptive internal model controller for DFIG wind farms with dither injection","authors":"N. Amuthan, Shikha Singh","doi":"10.1109/ICPWS.2009.5442663","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442663","url":null,"abstract":"This paper presents the Direct model reference adaptive internal model controller for doubly fed induction generator used in wind farms based on MIT Rule adjustment mechanism with dither injection. Direct model reference adaptive internal model controller is developed and it is tuned using MIT rule. Rotor current controller is designed using direct model reference adaptive internal model controller to improve the robust performance of the system and triangular dither signal is injected to improve the performance of the system. The performance is compared with conventional direct model reference adaptive internal model controller and is described. Flexibility of proposed method in shunt connection is illustrated, dynamic response under fault causes sag condition, like sudden drop in terminal voltage and it affects the behavior of the machine, this phenomenon is simulated using MATLAB/SIMULINK and is presented.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"27 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120974630","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
A methodology for selective localization of capacitor banks for power systems 电力系统电容器组的选择定位方法
2009 International Conference on Power Systems Pub Date : 2009-12-01 DOI: 10.1109/ICPWS.2009.5442688
S. Raman, Amit Jain, M. Ramamoorty, A. Vaghamshi
{"title":"A methodology for selective localization of capacitor banks for power systems","authors":"S. Raman, Amit Jain, M. Ramamoorty, A. Vaghamshi","doi":"10.1109/ICPWS.2009.5442688","DOIUrl":"https://doi.org/10.1109/ICPWS.2009.5442688","url":null,"abstract":"The issue of voltage instability has been a predominant one to deal with in what has developed into power systems loaded near its maximum capabilities in recent times. To address this concern, with the added responsibility of accomplishing it with the resources economically, is a challenge in itself. As stated, the problem thus naturally draws attention to the localization of the components able to contribute to the stepping up of overall voltage in the system. This paper discusses a methodology for the suitable selection of buses for the placement of capacitors wherein the injection of a fixed amount of reactive power into each bus is made to depict a picture of the overall improved voltage in the system for the respective injection at that bus. The reduced Jacobian is used to determine the impact of the reactive power injection in the form of system voltage improvement. The significance however lies in this analysis being done for different operating points of the power system using continuation power flow to choose the optimum location for capacitor to affect maximum voltage improvement in total over a range of operating points. The relevant results are enlisted for the IEEE 14 bus system.","PeriodicalId":337759,"journal":{"name":"2009 International Conference on Power Systems","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115269980","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书