Volume 5: Biomedical and Biotechnology最新文献

筛选
英文 中文
Design of Human Head and Neck Replica to Facilitate Concussion and TBI Research 设计人体头颈部模型以促进脑震荡和脑外伤的研究
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-72094
Peyman Honarmandi, Elias Awikeh
{"title":"Design of Human Head and Neck Replica to Facilitate Concussion and TBI Research","authors":"Peyman Honarmandi, Elias Awikeh","doi":"10.1115/imece2021-72094","DOIUrl":"https://doi.org/10.1115/imece2021-72094","url":null,"abstract":"\u0000 Mitigating concussion and researching more about the motion of the brain is vital to develop safer protection gears for athletes and others around the world. The key to furthering research surrounding concussions is to dive deeper into the effect a hit to the head has on the brain. Most areas of this research look to analyze and track the movement of the head. As this may offer an idea as to what happens to the brain, there is still a completely different motion that the brain experiences during a hit. The goal of this project is to offer a realistic method to analyze the motion of the brain via a head and neck replica model. By creating a model with a human like brain within it, the motion of the brain can be tracked via accelerometers. Our goals with this project are to shed light on the lasting damage concussions can do to the brain and potentially study on further concussion prevention technology. What this project aims to accomplish is to create a head and neck model that can more accurately track the actual motion of the head and brain. Selection of the corresponding materials and validation of the model have been conducted. The purpose of creating this model would be to further the understanding of how the brain reacts to certain impacts within different scenarios.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134226714","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Pulse Wave Velocity and Transmission at the Carotid Artery and the Ascending Aorta 颈动脉和升主动脉脉波速度和传递
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-69412
Sara M. Smith, Justin Marin, Amari Adams, Keith West, Z. Hao
{"title":"Pulse Wave Velocity and Transmission at the Carotid Artery and the Ascending Aorta","authors":"Sara M. Smith, Justin Marin, Amari Adams, Keith West, Z. Hao","doi":"10.1115/imece2021-69412","DOIUrl":"https://doi.org/10.1115/imece2021-69412","url":null,"abstract":"\u0000 With consideration of a full set of mechanical properties: elasticity, viscosity, and axial and circumferential initial tensions, and radial and axial motion of the arterial wall, this paper presents a theoretical study of pulse wave propagation in arteries and evaluates pulse wave velocity and transmission at the carotid artery (CA) and the ascending aorta (AA). The arterial wall is treated as an initially-tensioned, isotropic, thin-walled membrane, and the flowing blood in the artery is treated as an incompressible Newtonian fluid. Pulse wave propagation in arteries is formulated as a combination of the governing equations of radial and axial motion of the arterial wall, the governing equations of flowing blood in the artery, and the interface conditions that relate the arterial wall variables to the flowing blood variables. We conduct a free wave propagation analysis of the problem and derive a frequency equation. The solution to the frequency equation indicates two waves: Young wave and Lamb wave, propagating in the arterial tree. With the related values at the CA and the AA, we evaluate the influence of arterial wall properties on their wave velocity and transmission, and find the opposite effects of axial and circumferential initial tensions on transmission of both waves. Physiological implications of such influence are discussed.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134433514","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design of a Carbon Fiber Ankle Foot Orthotic With Optimal Joint Stiffness 具有最佳关节刚度的碳纤维踝关节矫形器的设计
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-73248
A. Koch, Brandon Richardson, Daniel Schell, D. Piovesan
{"title":"Design of a Carbon Fiber Ankle Foot Orthotic With Optimal Joint Stiffness","authors":"A. Koch, Brandon Richardson, Daniel Schell, D. Piovesan","doi":"10.1115/imece2021-73248","DOIUrl":"https://doi.org/10.1115/imece2021-73248","url":null,"abstract":"\u0000 An Ankle Foot Orthosis, or AFO, is a device used in human rehabilitation to support lower extremities. The device is similar to a brace that is capable of maintaining the stability of a joint while storing some elastic energy to help lifting the legs at the ankle.\u0000 The main challenge for this design is to determine the optimal stiffness of the device and how such stiffness comes from the distribution of the stiffness at the joints. Furthermore, the device must be stiff enough for athletic play, but be comfortable for clinical scenarios.\u0000 We performed a set of experiments on a commercial AFO made of carbon fiber. The angles at the ankle and toes were measured during self-paced walking together with the interaction force between the shin and the AFO. Based on such measurements, we estimated the total rotational stiffness of the device and the distribution of stiffness at each joint. A 3-point bending test following ASTM D7264/D7264M-15 standard was used to evaluate the stiffness of the material produced by a Mark II 3D printer capable of printing long fiber composite. After the optimal printing parameters were selected to obtain the desired stiffness of the material, a finite element analysis was performed to design the AFO geometry to match each single joint stiffness.\u0000 This customized procedure can provide the design specification of a device so to produce the best athletic performances still maintaining comfort.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114517678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Improving the Performance of Ambulatory Gait Training System for Rehabilitation by Mechatronics and Design Simulation 基于机电一体化和设计仿真提高康复运动步态训练系统的性能
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-71487
D. Shetty, Lara A. Thompson, P. Sánchez, C. Campana
{"title":"Improving the Performance of Ambulatory Gait Training System for Rehabilitation by Mechatronics and Design Simulation","authors":"D. Shetty, Lara A. Thompson, P. Sánchez, C. Campana","doi":"10.1115/imece2021-71487","DOIUrl":"https://doi.org/10.1115/imece2021-71487","url":null,"abstract":"\u0000 This paper addresses the design procedures and simulation results from the mechatronic model of the rehabilitation equipment, which can improve the functionality and precision of the ambulatory gait training system. The distinguishing feature of mechatronic systems is the achievement of system functionality through intensive integration. The paper demonstrates how the mechatronic design modeling has helped improve the design and performance of the new rehabilitation equipment built by the authors and is known as Navigaitor. The Navigaitor is designed to aid the patients who need to improve their balance and walk. The mechatronics aspects allow a better understanding of the dynamic behavior and interactions of the components. Depending on the severity of the patient’s injury (stroke survivor, Parkinson, etc.), the oscillatory motion can range from uniform to non-uniform. The motion needs to be converted from the oscillatory sinusoidal motion of the patient into linear motion that the system can follow the patient with minimum lag and maximum stability. The data acquired during the training stage showing a different rate of recovery and response assists the system designers and thereby provides input to fine-tune the system and upgrade the control requirements.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114375478","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Lower Limb Joint Reaction Forces and Moments Calculations for a “Dabke Jump”: Application of 3D Inverse Dynamics Technique “小跳”下肢关节反作用力和力矩计算:三维逆动力学技术的应用
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-68282
Perla C. Sammour, I. Hage, C. Ghnatios, N. Metni, Ré-Mi S. Hage, R. Hamade
{"title":"Lower Limb Joint Reaction Forces and Moments Calculations for a “Dabke Jump”: Application of 3D Inverse Dynamics Technique","authors":"Perla C. Sammour, I. Hage, C. Ghnatios, N. Metni, Ré-Mi S. Hage, R. Hamade","doi":"10.1115/imece2021-68282","DOIUrl":"https://doi.org/10.1115/imece2021-68282","url":null,"abstract":"\u0000 The study involves applying the inverse dynamics to calculate the 3-dimensional (3D) reaction forces and moments at the lower limbs namely: hip, knee, and ankle joints. The study is specific to performing the Lebanese folkloric dance known as the “Dabke jump”. The aim is to compare the impact forces generated at the three joints. Also envisioned is to contrast the forces generated for a male (63 Kg) and a female (50.4 kg) dancer (barefoot and while she wears 8.5 cm high heels).\u0000 The experimental part of the study consists of measuring position data of the right lower limb of the participant when performing the jump. All at once, the reaction forces generated at the impact are synchronously measured. The position data are obtained using the OptiTrack™ motion capture system. The ground reaction forces are measured using the AMTI force plate.\u0000 Using kinematics analysis in conjunction with inverse dynamics, the filtered and fitted experimental data are then imported into MATLAB® to obtain a table containing all the internal forces and moments at each joint (ankle, knee, and hip joints) as function of time. Next, the results are plotted and compared. Force and moment data are analyzed using R Project for statistical computing software. The boxplot technique is used to identify the presence of outliers. Using both MannWhitney and Krustkal Wallis tests, all joint reaction forces and moments in three dimensions are analyzed, at different time intervals to instantaneously identify the prominent effect on each joint.\u0000 It is found that the largest impact force is generated at the ankle joint for both subjects. For the male participant, the impact maximum vertical force measured at the ankle is about 2.2 of body weight (BW). For the female participant, a maximum vertical force of 1.84 BW is recorded both barefoot and with heals. The forces and moments obtained for this male individual are larger than those obtained for this female individual. Moreover, for the female participant the vertical forces obtained for all joints when wearing an 8.5 cm high heel are found to be lower than those obtained when she is barefoot. This is most notably recorded at the hip joint where a maximum decrease of 21.2% is observed. This finding suggests that when a dancer performs the “Dabke jump”, wearing an appropriate heel of suitable height will decrease the vertical impact forces on the lower limb joints and decrease the risk of injuries.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126379022","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigating the Use of Magnetic Actuation for a Self-Contained Functional Tongue Prosthetic 磁致动在独立功能舌假体中的应用研究
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-69641
Sarah Vasquez, Thomas G Lipkin, D. Landry, Jenna Currie, P. Radhakrishnan, D. Albrecht, K. Pahlavan
{"title":"Investigating the Use of Magnetic Actuation for a Self-Contained Functional Tongue Prosthetic","authors":"Sarah Vasquez, Thomas G Lipkin, D. Landry, Jenna Currie, P. Radhakrishnan, D. Albrecht, K. Pahlavan","doi":"10.1115/imece2021-69641","DOIUrl":"https://doi.org/10.1115/imece2021-69641","url":null,"abstract":"\u0000 Oral cancer can result in the loss of the tongue through surgical removal known as glossectomy. Patients who have undergone this procedure face challenges during speech, mastication, and deglutition. Currently, tongue prosthetics lack functionality and are mainly cosmetic. Many of these prosthetics are made of wax and connected to a retainer, which attaches to the back molars of the patient. The goal of this project was to develop a self-contained mechatronic tongue prosthesis that can fit within the oral cavity and aid in deglutition. Investigations into various techniques and sensors supporting miniaturization were carried out and magnetic actuation was found to be the most promising technique. The development process involved redesigning the silicone cast to house sensors, selecting sensors and components for magnetic actuation, magnetic field quantification and miniaturizing various other electrical components. The tongue prosthesis was tested, and the displacement was comparable to a normal human tongue. Details from literature review, design iterations, simulations, validation processes, manufacturing challenges and conclusions will be discussed in depth in this paper.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129217281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analytical Impact Analysis of the Brain Motion in Low-Velocity Head Impacts Using Concentric Viscoelastic Bodies 同心粘弹性体低速头部碰撞中脑运动分析
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-73590
P. Thapa, Shahab Mansoor Baghaei, A. Sadegh
{"title":"Analytical Impact Analysis of the Brain Motion in Low-Velocity Head Impacts Using Concentric Viscoelastic Bodies","authors":"P. Thapa, Shahab Mansoor Baghaei, A. Sadegh","doi":"10.1115/imece2021-73590","DOIUrl":"https://doi.org/10.1115/imece2021-73590","url":null,"abstract":"\u0000 Mild traumatic brain injury (mTBI) and concussion could occur in vehicular accidents, contact sports, or other physical traumas when the head is subjected to high linear or angular acceleration. Understanding the physiology and dynamics of such events has attracted many researchers’ attention. Due to the hidden risks in such events, it is very important to understand the cause and effect of the relative motion between the brain and skull and the implications of normal and shear stresses in the meningeal region.\u0000 Since the early 70’s to date wide variations of experimental, analytical, and numerical models has been developed to analyze multilayer spherical head impact model to quantify the dynamic response of the human head due to blunt impact and explain the process and likely cause of mild traumatic brain injuries. There are many high-fidelity finite element models and research studies of the various head models, but very limited analytical models to date for parametric studies. Analytical models of head impact play a vital role in predicting relative displacement between skull and brain, transmitted forces, post-impact velocity, and acceleration of the head system. However, to define a reliable mathematical model which can illustrate the mechanisms of motion and deformation of the brain within the skull requires knowledge of dynamics of a multibody system, material properties, boundary conditions at the brain–skull interface, and experimental data or FEM simulation for validation.\u0000 In this paper, a mathematical model of the brain and meningeal layers, as two separate viscoelastic materials that are modeled using a Kelvin–Voigt model, have been investigated and the motion of the brain relative to the skull during blunt head impacts have been analyzed. Specifically, the model consists of three concentric spherical mediums including a spherical shell (skull), a thin spherical layer (meningeal layer), and a spherical mass (brain). The interface between these spherical mediums consists of springs and dashpots representing stiffness and viscoelasticity of the skull, meningeal layer, and the brain. This model of the head is initially at rest and subjected to an impulse load. The equations of motion for this multi-body system were obtained, solved, and validated by performing a lumped mechanical model and the multibody dynamics finite element analysis simulation. Multiple parametric studies were performed to determine the maximum amplitude of impact force for which there is a contact between the skull and the brain.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126649715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Behavior of Cell Flowing Over Oblique Micro Rectangular Groove 斜微矩形槽上的细胞流动行为
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-69696
S. Hashimoto, Hiroki Yonezawa, Shogo Uehara
{"title":"Behavior of Cell Flowing Over Oblique Micro Rectangular Groove","authors":"S. Hashimoto, Hiroki Yonezawa, Shogo Uehara","doi":"10.1115/imece2021-69696","DOIUrl":"https://doi.org/10.1115/imece2021-69696","url":null,"abstract":"\u0000 Is it possible to distinguish cells with minimally-invasive method according to the characteristics of cells when moving through the flow path in vitro? A microflow channel with 45 degrees diagonal microgrooves against the mainstream direction has been manufactured by photolithography technique. The flow path between the two transparent PDMS (polydimethylsiloxane) disks (0.05 mm high, 1 mm wide, and 25 mm long) has a rectangular microgroove (4.5 μm deep, 0.2 mm long) at the bottom with variations in groove widths (0.03 mm, 0.04 mm, and 0.05 mm). The deformation and direction change of floating mouse-myoblasts (C2C12) during passage over the microgroove were measured. The experimental result shows that the change in angle tends to be smaller for cells with larger shape changes in the groove. This method may be applicable to classification by cell deformability.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117023011","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fatigue Properties of 3D Printed Carbon Fiber 3D打印碳纤维的疲劳性能
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-67626
A. Schmitz
{"title":"Fatigue Properties of 3D Printed Carbon Fiber","authors":"A. Schmitz","doi":"10.1115/imece2021-67626","DOIUrl":"https://doi.org/10.1115/imece2021-67626","url":null,"abstract":"\u0000 Three-dimensional printing with carbon fiber has been used to create lower limb prosthetics. However, the fatigue resistance of carbon fiber is understudied. The goal of this work was to quantify the fatigue properties of three-dimensionally printed carbon fiber. Moore bending fatigue specimens were created using a commercially available printer (Markforged, Watertown, MA). Specimens were printed using (1) a chopped carbon fiber matrix or (2) chopped carbon fiber matrix with embedded continuous carbon fiber. Cycles to failure was measured for three bending stress levels: 11.8, 8.8, and 7.4 kpsi. Ultimately, adding continuous carbon fiber to the chopped matrix increased the short cycle fatigue life (i.e. 103) from 17 to 274 MPa and had no effect on the endurance limit. During a single stance phase of the gait cycle, the heel and toe portions of a prosthetic foot experience up to 262 MPa of von Mises stress. This means the carbon fiber produced from three-dimensional printing would last two gait cycles. Hence, lower limb prosthetics cannot yet be made completely from three-dimensionally printed carbon fiber.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128617933","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Effect of Shaking at or Near Resonance of a Simple Head Model on Skull/Brain Connectors 简单头部模型共振或近共振振动对颅脑连接的影响
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-69054
J. Daboin, P. Saboori
{"title":"Effect of Shaking at or Near Resonance of a Simple Head Model on Skull/Brain Connectors","authors":"J. Daboin, P. Saboori","doi":"10.1115/imece2021-69054","DOIUrl":"https://doi.org/10.1115/imece2021-69054","url":null,"abstract":"\u0000 A solid model of a six-month-old child has been developed using average human anatomical characteristics combined with crash test dummy dimensions. The model consisted of a body and limbs, and a neck and head combination with the head being hollow and housing a hemispherical brain. This model was then exposed to a linear sinusoidal input displacement to the chest, and the angular displacement of the skull and brain were observed. The resulting data showed that the oscillatory behavior was a function of frequency, and maximal oscillations existed at a frequency close to the expected natural frequency of the head/neck system, and at a frequency one order of magnitude greater than this frequency. In addition, when a square wave was applied, rather than a sine wave, the resulting oscillation proved to be more violent; and finally, a real input was applied to the model, from previous tests, to discover if a different oscillatory behavior resulted.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114841574","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信