2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)最新文献

筛选
英文 中文
Analysis of distribution network by reliability indices 配电网可靠性指标分析
Jeenia Bhadra, T. Chattopadhyay
{"title":"Analysis of distribution network by reliability indices","authors":"Jeenia Bhadra, T. Chattopadhyay","doi":"10.1109/EPETSG.2015.7510094","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510094","url":null,"abstract":"A distribution network links the bulk power system to the utilities or customers. The reliability of such a system is assessed by the performance at the customer end, i.e., at the load points. This paper presents the comparison and performance some of the reliability indices by increment of load in equal and unequal mode on every node. Hence, it helps to find out a healthy mode of increment of load for 33-node distribution network. The results show that a multiplying factor is suitable for the increment of load at various nodes for a distribution system.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116037355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Performance evaluation of DEPSO algorithm on automatic voltage regulator using conventional PID & Fuzzy-PID controller 基于传统PID和模糊PID控制器的DEPSO算法在自动调压器上的性能评价
Snigdha Priyambada, P. Mohanty
{"title":"Performance evaluation of DEPSO algorithm on automatic voltage regulator using conventional PID & Fuzzy-PID controller","authors":"Snigdha Priyambada, P. Mohanty","doi":"10.1109/EPETSG.2015.7510141","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510141","url":null,"abstract":"This paper describes about the design and scrutiny of AVR using three different controllers namely Fuzzy-PID, PID-N & PID. The proposed system is optimized using novel DEPSO algorithm tuned by aforementioned three controllers. Objective function for the AVR system is taken as Integral Time Absolute Error (ITAE). The dynamic response of the system is obtained. Finally it is being observed that FPID proves better in terms of peak overshoot & settling time than the other two. The robustness analysis is by varying time constants by ± 50 %.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116735972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Load frequency control of an interconnected three-area thermal power system using conventional PID & Fuzzy-logic controller 采用传统PID和模糊控制器对三区互联火电系统负荷频率进行控制
T. Pati, Jyoti Ranjan Nayak, B. K. Sahu, Bibek Gantayat
{"title":"Load frequency control of an interconnected three-area thermal power system using conventional PID & Fuzzy-logic controller","authors":"T. Pati, Jyoti Ranjan Nayak, B. K. Sahu, Bibek Gantayat","doi":"10.1109/EPETSG.2015.7510137","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510137","url":null,"abstract":"This paper deals with design of automatic generation control (AGC) of a three-area interconnected thermal power system using conventional PID, PID-N & Fuzzy-PID controller structures. A single input Fuzzy Proportional Integral Derivative (FPID) controller is used to study the transient response of the proposed system. Area-1 & 2 1 consists of two thermal generating units with reheat turbinesand area-3 has one thermal generating units of non-linear turbine model with GRC unit. The gains of the proposed three controllers are optimized using novelhybrid Differential Evolution-Particle Swarm Optimization (DEPSO) technique. Step load perturbation (SLP) of 1 % is applied in area1 to study the performance of the proposed algorithm upon three controllers on as the three-areas in terms of undershoot, overshoot & settling time. Finally it is observed that the FPID controller optimised DEPSO algorithm performs better than the other two.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126898159","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Comparative analysis of resonant power converters for renewable energy generation applications 谐振功率变换器在可再生能源发电中的应用比较分析
R. Sah, Shivam
{"title":"Comparative analysis of resonant power converters for renewable energy generation applications","authors":"R. Sah, Shivam","doi":"10.1109/EPETSG.2015.7510086","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510086","url":null,"abstract":"This paper develops comparative analysis of resonant power converters for renewable energy application. These circuit topology of resonant converter with zero-voltage switching (ZVS) with an energy-blocking diode with zero-current switching (ZCS). Only active power switches are used for power energy conversion to reduce the cost of active power switches and control circuits. The active power switches are controlled by pulse width modulation at a fixed switching frequency and a constant duty cycle. In all cases the resonant converters are operated at discontinuous conduction mode, the inductor current through the resonant tank could achieve ZCS of the energy-blocking diodes. All active power switches can be operated with ZVS, and measured energy conversion efficiency. MATLAB/SIMULATION results demonstrated a satisfactory performance of resonant power converter, which is particularly, suited to the energy conversion applications in renewable energy generation systems.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"193 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114863901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Short-term hydrothermal scheduling using Time Varying Acceleration coefficient based Particle Swarm Optimization with Constriction Factor and Inertia Weight Approach 基于收缩因子和惯性权的时变加速度系数粒子群优化短期热液调度
Koustav Dasgupta, Sumit Banerjee, C. K. Chanda
{"title":"Short-term hydrothermal scheduling using Time Varying Acceleration coefficient based Particle Swarm Optimization with Constriction Factor and Inertia Weight Approach","authors":"Koustav Dasgupta, Sumit Banerjee, C. K. Chanda","doi":"10.1109/EPETSG.2015.7510163","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510163","url":null,"abstract":"The paper presents Time Varying Acceleration Coefficient Based Particle Swarm Optimization with Constriction Factor and Inertia Weight Approach which is applied to determine the optimal hourly schedule of power generation in a hydrothermal power system. The objective of the hydrothermal scheduling problem is to find out the discharge of hydro plants and power generation of thermal plants to minimize the total fuel cost at a schedule horizon while satisfying various constraints. In the present work, the effects of valve point loading in the fuel cost function of the thermal plants are also considered. The developed algorithm is illustrated for a test system consisting of four hydro plants and three thermal plants. It is found that proposed Time varying acceleration coefficient based particle swarm optimization with constriction factor and inertia weight factor approach (TVAC-PSOCFIWA) appears to be the powerful to minimize fuel cost.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131395640","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Estimation of tire slip-angles for vehicle stability control using Kalman filtering approach 基于卡尔曼滤波的车辆稳定性控制中轮胎滑移角估计
S. Sen, Shouvik Chakraborty, A. Sutradhar
{"title":"Estimation of tire slip-angles for vehicle stability control using Kalman filtering approach","authors":"S. Sen, Shouvik Chakraborty, A. Sutradhar","doi":"10.1109/EPETSG.2015.7510138","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510138","url":null,"abstract":"The increasing number of accidents worldwide has motivated the need to develop technologically sophisticated automobiles that provide improved vehicle handling, stability, comfort, fuel efficiency and safety. In automotive industry, current focus is on the development of active safety systems, which assist the driver in order to avoid critical situations. But, some key states which are valuable for the vehicle dynamics control system are not measurable or cost prohibitive. Hence, the states are to be estimated. This paper presents the estimation of tire slip-angles, which are among the essential states. A simplified model of the vehicle has been considered during a turning maneuver. Then, the interdependency of lateral and longitudinal velocities w.r.t yaw rate is depicted. Later, the longitudinal velocity is subsequently used for slip angle estimation for the front and the rear wheels using linear Kalman filter approach. Computer simulation have been conducted to verify the proposed approach with results indicating that the proposed approach is very effective and robust in estimating tire slip-angles of a vehicle.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131942338","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Design a compact tri-band band pass filter using asymmetric SIRs and DGS 使用非对称SIRs和DGS设计一个紧凑的三带带通滤波器
T. Sheikh, J. Borah, Sahadev Roy
{"title":"Design a compact tri-band band pass filter using asymmetric SIRs and DGS","authors":"T. Sheikh, J. Borah, Sahadev Roy","doi":"10.1109/EPETSG.2015.7510169","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510169","url":null,"abstract":"In this research, a novel compact tri-band microstrip bandpass Filter is design using Asymmetric SIRs and DGS to achieved the characteristic of low insertion loss, high selectivity, wider range of bandwidth, low group delay for WiMAX (2.5GHz), WiMAX (3.4GHz) and UWB applications. The novel filter is design intentionally selecting the impedance ration(R) and length of the microstrip of the asymmetric SIRs and DGS is used to improve the coupling strength of the last band. The measurement entities of the novel filter for WiMAX (2.5GHz), WiMAX (3.4GHz) and UWB (4.12-5.32GHz) are insertion losses (S21) are -0.26dB, -0.07dB, -0.05dB, and return losses (S11) are -11.29dB, -19.25dB and -22.64dB respectively. The response of the filter was simulated using Ansoft HFSS Simulator.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126145770","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Optimal D-STATCOM placement in radial distribution system based on power loss index approach 基于损耗指标法的径向配电系统D-STATCOM优化配置
A. Gupta, Abhinav Jain, Ashwani Kumar
{"title":"Optimal D-STATCOM placement in radial distribution system based on power loss index approach","authors":"A. Gupta, Abhinav Jain, Ashwani Kumar","doi":"10.1109/EPETSG.2015.7510122","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510122","url":null,"abstract":"In this paper, power loss index method is used for the placement of D-STATCOM in radial distribution system for reduction of line losses and improvement of voltage profile. For this, the load flow is carried out for calculating bus parameters. The mathematical modeling of D-STATCOM is performed for calculation of reactive power injections of D-STATCOM for all the buses. This reactive power value is used for finding out the optimal location of D-STATCOM by power loss index (PLI) method. Finally the proposed algorithm is tested on IEEE 10, 33 and 69-bus radial distribution system by using MATLAB software. Results show the reduction in line losses and improvement in voltage profile for all test systems.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128302068","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Terminal reliability assessment and comparision of new SEN-MIN: Critical component in power systems generation 新型SEN-MIN——电力系统发电关键部件的终端可靠性评估与比较
S. Gupta, G. L. Pahuja
{"title":"Terminal reliability assessment and comparision of new SEN-MIN: Critical component in power systems generation","authors":"S. Gupta, G. L. Pahuja","doi":"10.1109/EPETSG.2015.7510107","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510107","url":null,"abstract":"Multistage Interconnection Networks (MIN), characterized by minimum latency, high Bandwidth & Throughput and cost effectiveness as compared to counterparts, embedded in parallel and multiprocessing systems allow faster communication of data related to nuclear reactor and nuclear fusion in effective and efficient generation of electricity along with decision making and functioning of the system. Reliability and Fault Tolerance of different variants of SEN MIN such as SEN, SEN+, SEN+2 exist in literature. Recently reliability evaluation of SEN-has been advanced. Limitations such as no full connectivity, Single path availability have been figured out by us and also (i) a new topology of SEN-has been purposed that mitigates the limitations, and (ii) Terminal reliability of purposed network has been computed and demonstrated that it not only outperforms other SEN variants in terms of terminal reliability and cost but has the improved features of fault tolerance and disjoint minimal length path set.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"66 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128671442","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Short circuit analysis and adaptive zonal protection of distribution system with distributed generators 分布式发电机配电系统短路分析及自适应分区保护
K. Vijitha, M. Selvan, P. Raja
{"title":"Short circuit analysis and adaptive zonal protection of distribution system with distributed generators","authors":"K. Vijitha, M. Selvan, P. Raja","doi":"10.1109/EPETSG.2015.7510069","DOIUrl":"https://doi.org/10.1109/EPETSG.2015.7510069","url":null,"abstract":"Grid integration of Distributed Generation (DG) is considerably increasing in recent days in order to meet the ever increasing electricity demand and to reserve the fossil fuel resources. DG is expected to play an important role in modern electric power system in near future due to the support offered by current political policies and global environmental issues. Besides a lot of benefits offered by DG, it may cause negative impacts on the distribution network. The injected currents of DGs to a distribution network lead to not having a radial network anymore, and consequently network faces an inefficient protection system that was formerly designed according to the existing philosophy behind the distribution network. In the present work, an adaptive zonal protection scheme is suggested for distribution network with DG. The distribution network is divided into several zones with the help of boundary circuit breakers. The operation of these circuit breakers are monitored and controlled by the control center. The analysis is carried out in an 11 kV, 25-bus radial distribution network and the results are discussed.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"29 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120983791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×