{"title":"Spaciotemporally Generated Microfluids: Asymmetric Flow Resistor for On-chip Pumping","authors":"Makoto Saito, S. Sakuma, Y. Kasai, F. Arai","doi":"10.1109/MHS48134.2019.9249293","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249293","url":null,"abstract":"In the conventional microfluidic chips, the functions of microchannels are limited due to the laminar flow environment. To overcome the limitation, we present an unpreceded concept of “spaciotemporally generated microfluids (SGMs)” which generate micro-vortices in micro channels as “walls” of pressure. Based on this concept, we developed “asymmetric flow resistors (AFRs), which have different flow resistance to bidirectional flow. In this paper, we evaluate flow resistance of AFRs and demonstrate on-chip pumping.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125862858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Textile-based Electrode Array for FES and sEMG Recording Fabricated by Screen Printing","authors":"Wenguang Lu, D. Owaki, M. Hayashibe","doi":"10.1109/MHS48134.2019.9249261","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249261","url":null,"abstract":"In this paper, a wearable textile-based electrode array that is capable of both functional electrical stimulation (FES) and surface electromyography (EMG) recording was proposed. The electrode array was fabricated with a screen-printing method by printing multi-layer functional stretchable pastes on polyester/cotton textile base. During the FES and sEMG recording tests, the fabricated electrode array showed the capability of realizing electrical stimulation and sEMG recording. This research aims at providing a new multifunctional tool for rehabilitation purpose. In this paper, a wearable textile-based electrode array that is capable of both functional electrical stimulation (FES) and surface electromyography (EMG) recording was proposed. The electrode array was fabricated with a screen-printing method by printing 4 layers functional stretchable pastes, which were stretchable insulating paste, stretchable conductive silver paste, and stretchable conductive carbon paste, on polyester/cotton textile base. For tests, the fabricated electrode array was connected to a customized connector, through the connector the fabricated electrode array was connected to FES stimulator and sEMG recording device for tests. During the FES and sEMG recording tests, the fabricated electrode array showed the capability of realizing electrical stimulation and sEMG recording, while the sEMG recording quality was not very stable and needs to be improved. This research aims at providing a new multifunctional tool for rehabilitation purpose.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121806759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Detection and Control of Air Liquid Interface with an Open-Channel Microfluidic Chip for Rare Cell Isolation","authors":"Bilal Turan, T. Masuda, F. Arai","doi":"10.1109/MHS48134.2019.9249275","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249275","url":null,"abstract":"We have developed a rare cell isolation system using an open-channel microfluidic chip. We have developed an image analysis algorithm to detect the position of the air-liquid interface and using this to control the flow speeds of sample introduction and suction syringe pumps, we can control the air-liquid interface position.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121114184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kento Tanaka, S. Sugimoto, T. Tamiya, K. Yagi, Satoshi Kobayashi
{"title":"Improvement of strength and porosity of β-TCP/HA composited bone filling material synthesized by Hydrothermal Hot-Pressing","authors":"Kento Tanaka, S. Sugimoto, T. Tamiya, K. Yagi, Satoshi Kobayashi","doi":"10.1109/MHS48134.2019.9249332","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249332","url":null,"abstract":"At present, it is expected that we can use the β-tricalcium phosphate (β-Ca3(PO4)2, β-TCP) bone graft material with good bio absorbability for the treatment of bone defects. However, there is a problem that the strength of β-TCP applied clinically is low. It is because a porous body having a porosity of 70 % or more is required to speed up the reformation of the affected area in the scenes of medical treatment. The wet method is mainly used in the conventional β-TCP synthesis. Although the method can easily control porosity and pore shape, there is a limit to improvement of its strength. Therefore, we studied in order to synthesize a bone filling material that maintains a compressive strength of 10 MPa while having a porosity of 70 % by the Hydrothermal Hot-Pressing (HHP) method. Since the HHP makes a sample denser and generates pores at the same time, it is possible to synthesize a porous and high-strength sample. Furthermore, improvement in strength is expected by compositing Hydroxyapatite (Ca10(PO14)6(OH)2, HA) with β-TCP synthesis step. Whereas, although there are cases that β-TCP is composited in the HA sintered body in the previous study, there is no reports of compositing HA with β-TCP by the HHP method. Dividing the synthesis process of β-TCP into three steps of HHP, pre-sintering and sintering, we established the synthesis method of β-TCP / HA composited by controlling the reaction that occurs in each process. In addition, controlling the amount of water generated in each reaction, we reduced several millimeters of crucks to several micrometers order, and the porosity and strength were greatly improved. As a result, we were able to obtain sample with a porosity of 49 % and a compressive strength of 25 MPa. However, it was difficult for the molded body to maintain high strength for a long time, because cracks generated during sintering grew as time passes and it became powder (powdering). The sintered body kept its shape just after the sintering, but powdering occurred in seven days. In addition, powdering is more likely to occur as the porosity is higher. Thus we have to solve this problem to synthesize a sample with higher porosity. We analyzed the composition of the sintered body by XRD in order to investigate the cause of powdering. In consequence it became clear that α-tricalcium phosphate (α-Ca3(PO4)2,a-TCP) is mixed in and disappears in 7days. α-TCP is the high temperature phase of β-TCP. It is known to be soluble in water and to hydrolyze into HA. Thus, it is considered that powdering occurs in the following process. First, as the crystallinity of the synthesized at the time of HHP is lower, the reactivity in pre-sintering and sintering increases, and α-TCP is formed at a relatively low temperature. Second, powdering proceeds as α-TCP generated during sintering gradually hydrolyzes. Based on this result, we tried suppressing the formation of α-TCP. As the result of controlling the crystallinity of the synthesized at the time of H","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121214249","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of drive mechanism of forceps for Single Incision Laparoscopic Surgery","authors":"Ryo Ono, M. Nokata","doi":"10.1109/MHS48134.2019.9249320","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249320","url":null,"abstract":"We have designed and developed a forceps which has construction to circumvent the abdominal wall. This forceps keeps the operating portion and the grasping portion in alignment by having three parallel link mechanisms. According to a result of the operation verification, the transmission part was not able to transmit the drive power for switching and rotating actions of the grasping portion because the transmission part was caught inside of this forceps. Therefore, the objective of our research is to the development of the drive mechanism of this forceps. As the first step of our research, we experimented to confirm the specification of bending the transmission part by using two rotary encoders. Thus, we found the bending angle of the transmission part that the drive power can be transmitted.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124022795","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of novel tensile testing device for SEM observation of thin films under tension","authors":"Kensuke Nakata, T. Ando","doi":"10.1109/MHS48134.2019.9249346","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249346","url":null,"abstract":"We report a novel tensile testing device that maintains a deformation even after a load applied to extend a specimen is removed. The device is based on a compliant mechanism with a deformable frame, up and down springs, and two parallel beams to directly apply a force to the specimen. Two markers are included in the device to give the displacement, from which the strain and stress ate obtained it. This device uses a ratchet-like structure as the mechanism to maintain deformation even after the load is removed. From the results of the analysis of the device, we obtained a strain of 1.1 % and a stress ratio of 1.03, in agreement with the expected values. The device utilizes an SOI wafer and the Bosch process.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122550170","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fusion of life and machine to create novel principle devices","authors":"Y. Tanaka","doi":"10.1109/MHS48134.2019.9249278","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249278","url":null,"abstract":"A number of recent studies have exploited the sizes and functional properties of microdevices and cellular mechanical components to construct bio-microdevices. Micro total analysis systems (μ-TAS), or lab-on-a-chip, is a promising field that relies on microelectromechanical system (MEMS) technologies and creates extremely efficient and novel conceptual devices that exploit the advantages of microfluidics. One of the most significant characteristics of these devices is that their scale can accommodate different cell sizes and processing capabilities. Based on this fact, a number of efficient bioreactors and bioassay systems using cellular functions have been produced. To date, the main focus of these devices has been the analysis of cellular chemical functions. On the other hand, our concept is to use cells as components of devices. So far, we have developed a various kind of life-machine fusion devices [1]. The working principle of these devices are novel because they just use chemical energy input. Understanding fundamental concepts behind the distinct features and performance characteristics of these cell-based micro-systems will lead to development of new devices that will be exploited in various fields in the future.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129010687","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Maruyama, T. Masuda, Ruixuan Weng, Zhaoyu Wang, Eiji Tokai, F. Arai
{"title":"Fluorescence Microsensor Using Near-Infrared Light for Physiological Measurement inside Tissue","authors":"H. Maruyama, T. Masuda, Ruixuan Weng, Zhaoyu Wang, Eiji Tokai, F. Arai","doi":"10.1109/MHS48134.2019.9249274","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249274","url":null,"abstract":"This paper introduces a novel measurement method at the inner pH in the deep area of the tissue-like structure. The proposed method uses fluorescence microsensors using near-infrared light, which represents high tissue transmittance, and reference sensors for compensating the absorption of excitation and emission light to the tissue-like structure. In this paper, fluorescence pH microsensors are fabricated and evaluated the pH sensitivity. Finally, measurement of environmental pH using reference sensors, and detection of fluorescence microsensor at 1.5 mm deep in tissue-like structure are successfully demonstrated.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128730657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Stress analysis of shelf acetabuloplasty for acetabular dysplasia patients using dynamical load during walking","authors":"Akira Komatsu, T. Iwami, Y. Shimada","doi":"10.1109/MHS48134.2019.9249282","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249282","url":null,"abstract":"In this study, we analyzed the stress distribution on the hip joint surface of pre-post surgery of shelf acetabuloplasty for acetabular dysplasia patients during walking using the musculoskeletal model and FEA. Firstly, we calculated the hip contact force during walking using the commercial musculoskeletal software from motion capture data and force gauge data. Secondly, we created the three-dimensional finite element (FE) model of the patient-specific hip joint using the modeling software from computed tomography data. The participants were two female acetabular dysplasia patients. The FE model has constituted from the pelvis (acetabulum), femur (femoral head), and cartilage layer (Labrum, articular cartilage). Finally, we analyzed the stress distribution and the maximum stress value of the hip joint model using the FEA software. In the analysis, von-mise equivalent stress at each load pattern in the stance phase (Heel strike, 1st peak, and Toe off) was analyzed with the load during walking calculated by the musculoskeletal model as the boundary condition. As a result, the stress distribution on the hip joint surface was dispersed in the postoperative model compared with the preoperative model in all participants. The maximum stress value was reduced in the postoperative model compared to the preoperative model in all participants.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127545609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Miyawaki, Ayuko Saito, Yoshikazu Kobayashi, Satoru Kizawa, T. Matsunaga, Y. Shimada
{"title":"Development of Exercise Support Apparatus for Prevention of Locomotive Syndrome","authors":"K. Miyawaki, Ayuko Saito, Yoshikazu Kobayashi, Satoru Kizawa, T. Matsunaga, Y. Shimada","doi":"10.1109/MHS48134.2019.9249325","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249325","url":null,"abstract":"Locomotive syndrome is the state in which a risk of a person needing care increases because of an impediment of the locomotive parts of the body. The main cause is functional decline of locomotive organs such as the bones, joints, and muscle. The syndrome is the main cause of the necessity of care for bedridden people. This disease is severer than the musculoskeletal ambulation disability symptom complex indicating the state entailing increased risk of a decline of balance ability and walking ability, homeboundness, and increased falling because of aging. Exercise and training are effective as preventive measures. The author developed an exercise-assisting device. Results show that the exercise-assisting device is effective for preventing Locomotive syndrome.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130223904","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}