The Japanese journal of medical instrumentation最新文献

筛选
英文 中文
Development of an artificial joint with excellent fluid film lubrication performance: Part 2 Evaluation of lubricating film maintenance ability of the sliding surface@@@第2報 試作した摺動部コンポーネントの潤滑膜維持能の評価 Development of an artificial joint with excellent fluid film lubrication performance:Part 2 Evaluation of lubricating film maintenance ability of the sliding surface@@@第二报试制的滑动部组件的润滑膜维持功能的评价
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/jjmi.84.566
M. Morita, K. Doi, Masahito Miki, H. Ozawa, Yoshiyuki Ishimaru
{"title":"Development of an artificial joint with excellent fluid film lubrication performance: Part 2 Evaluation of lubricating film maintenance ability of the sliding surface@@@第2報 試作した摺動部コンポーネントの潤滑膜維持能の評価","authors":"M. Morita, K. Doi, Masahito Miki, H. Ozawa, Yoshiyuki Ishimaru","doi":"10.4286/jjmi.84.566","DOIUrl":"https://doi.org/10.4286/jjmi.84.566","url":null,"abstract":"As previously reported, we developed an ultra-low friction Total Hip Arthroplasty Components consists of a Ti-13Zr-13Nb femoral head with high sphericity and a UHMWPE acetabular socket. For these components, we evaluated the ability to maintain the lubricating film by using an artificial hip joint simulator and a detaching testing system of the femoral head from the acetabulum. As the results, the filloeing facts became clear. 1) The lubricating film was well maintained by radial clearance 13μm or less in the combination of PE acetabulum and metal head with the spericity of 8μm and 0.75μm, respectively. 2) If a good lubricating film is maintained in artificial joint sliding surface, the torque generated by the walking exercise fell to 1/100 of dry friction. Then, a good lubricating ability is kept at walking period 40rpm or more.","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128650702","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electromagnetic Interference of An Implantable Cardiac Pacemaker by A Home Electric Massage Machine Using Solenoid Coils 家用电动按摩机对植入式心脏起搏器电磁干扰的研究
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.82.399
S. Yoshida, K. Fujiwara, M. Hirose
{"title":"Electromagnetic Interference of An Implantable Cardiac Pacemaker by A Home Electric Massage Machine Using Solenoid Coils","authors":"S. Yoshida, K. Fujiwara, M. Hirose","doi":"10.4286/JJMI.82.399","DOIUrl":"https://doi.org/10.4286/JJMI.82.399","url":null,"abstract":"Massage machines designed to massage the shoulders are medical use devices which percussively massage the shoulders with pads driven by two solenoid coils. There was concern that such shoulder massagers might transmit electromagnetic interference (EMI) to implantable cardiac pacemakers because of the time-varying magnetic field associated with the activation of the solenoid coils. The objective of this study was to investigate the potential EMI effect of one such shoulder massage machine on implantable cardiac pacemakers. We measured the distribution profile of the magnetic field intensity around the shoulder massager. We also performed an inhibition test and an asynchronous test using the standardized Irnich human body model. The distribution profile of the magnetic field intensity was highest on one of the solenoid coils with a value of 212 (A/m). The maximal interference distance from this shoulder massager was 28cm. The technical specifications in the device’s user manual contain no information about the potential problems involving the EMI effect of the massager on implantable cardiac pacemakers. When patients with an implanted pacemaker use a shoulder massager activated with solenoid coils, a warning must be placed in the user’s manual regarding the potential adverse effects of EMI on pacemakers. ソレノイドコイルを使用した家庭用電気マッサージ器による 植込み型心臓ペースメーカへの電磁干渉に関する研究 吉 田 冴 子 藤 原 康 作 廣 瀬 稔 , * 1","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128969263","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Development of a New Dental Unit without a Water Supply Pipe for Infection Control 一种新型无供水管口腔感染控制装置的研制
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.83.439
Y. Tamazawa, K. Tamazawa, Masaaki Iwamatsu
{"title":"The Development of a New Dental Unit without a Water Supply Pipe for Infection Control","authors":"Y. Tamazawa, K. Tamazawa, Masaaki Iwamatsu","doi":"10.4286/JJMI.83.439","DOIUrl":"https://doi.org/10.4286/JJMI.83.439","url":null,"abstract":"Water contamination from conventional dental units is serious problem. Health, Labour and Welfare Ministry of Japan set recommended water quality standard as 100 CFU/ml ( common bacteria ) and 2,000 CFU/ml ( heterotrophic bacteria ). However, there are no reports on dental units meeting this standards in Japan. The purpose of this study was to develop a dental units without a water supply pipe, and meet water quality standards of Japan . We removed the water supply pipe from a dental unit, installing a built-in removable water supply tank. We grew common bacteria on standard agar at 36 ℃ for one days and heterotrophic bacteria on R2A agar at 20 ℃ for 7 days, and measured bacterial numbers in the conventional type and the tank type. The results of the conventional type ranged from 180 to 31,000 CFU/ml in common bacteria, and 2,000 to 86,000 CFU/ml in heterotrophic bacteria. The results of the tank type ranged from 30 to 50 CFU/ml in common bacteria, and 30 to 1,500 CFU/ml in heterotrophic bacteria achieving the water quality standard of Japan. The conventional type has a water supply pipe 6-7 m long. In contrast, the tank type has 26cm.","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126896047","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Usefulness and Future Aspect of Intraoperative MRI for Neurosurgery 术中MRI在神经外科中的应用及未来展望
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.81.282
Y. Muragaki, H. Iseki, T. Maruyama, Takashi Suzuki, K. Yoshimitsu, Souko Ikuta, M. Tamura, Taichi Saito, J. Okamoto, M. Chernov, C. Niki
{"title":"Usefulness and Future Aspect of Intraoperative MRI for Neurosurgery","authors":"Y. Muragaki, H. Iseki, T. Maruyama, Takashi Suzuki, K. Yoshimitsu, Souko Ikuta, M. Tamura, Taichi Saito, J. Okamoto, M. Chernov, C. Niki","doi":"10.4286/JJMI.81.282","DOIUrl":"https://doi.org/10.4286/JJMI.81.282","url":null,"abstract":"","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129121139","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Assessment of fatigue caused by VDT operation VDT作业疲劳评估
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/jjmi.90.405
N. Itoh, S. Takeda, Ryosuke Kasai, F. Kamijo, T. Kano, T. Shimamine, Minoru Ogino, Nae Hinata, K. Shinohara, Kohei Tanaka
{"title":"Assessment of fatigue caused by VDT operation","authors":"N. Itoh, S. Takeda, Ryosuke Kasai, F. Kamijo, T. Kano, T. Shimamine, Minoru Ogino, Nae Hinata, K. Shinohara, Kohei Tanaka","doi":"10.4286/jjmi.90.405","DOIUrl":"https://doi.org/10.4286/jjmi.90.405","url":null,"abstract":"","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116290098","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of an artificial joint with excellent fluid film lubrication performance: Part 3 : Improvement of the surface roughness of Ti-13Zr-13Nb artificial femoral head by ELID grinding processing@@@第3報 ELID研削によるTi合金製人工関節摺動部材の表面粗さの改善 Development of an artificial joint with excellent fluid film lubrication performance: Part 3:Improvement of the surface roughness of Ti-13Zr-13Nb artificial femoral head by ELID grindingprocessing@@@第3报根据ELID磨削的Ti合金制人工关节滑动部件的表面粗糙度的改善
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.85.2
M. Morita, A. Kagami, K. Doi, Masahito Miki
{"title":"Development of an artificial joint with excellent fluid film lubrication performance: Part 3 : Improvement of the surface roughness of Ti-13Zr-13Nb artificial femoral head by ELID grinding processing@@@第3報 ELID研削によるTi合金製人工関節摺動部材の表面粗さの改善","authors":"M. Morita, A. Kagami, K. Doi, Masahito Miki","doi":"10.4286/JJMI.85.2","DOIUrl":"https://doi.org/10.4286/JJMI.85.2","url":null,"abstract":"We have developed an ELID (ELectrolytic In-process Dressing) grinding technique that creates mirror-like surfaces on Ti-13Zr-13Nb alloys. To create a smooth surface, a metal-bonded grinding wheel was used for rough grinding and then a rubber-bonded wheel was used for final grinding. The optimum conditions for rough processing were a rotational speed of 400 rpm, a cut depth of 0.5 mm, a 40 mm/s feed rate of the work , and pitch interval for feeding in the y-direction of 1 mm. For final grinding, the optimum spark-out scanning time was 20 min. This new ELID processing technology decreased surface roughness to 30 nm (Ra).","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126435161","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Blood Pressure Measurement in High Noise and Patient Motion 高噪声和患者运动中的血压测量
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.80.647
隆洋 山口
{"title":"Blood Pressure Measurement in High Noise and Patient Motion","authors":"隆洋 山口","doi":"10.4286/JJMI.80.647","DOIUrl":"https://doi.org/10.4286/JJMI.80.647","url":null,"abstract":"","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"176 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132532800","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Roles and Advancements of Blood Pressure Monitors in Cardiovascular Medicine 血压监测仪在心血管医学中的作用与进展
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.80.622
O. Shirasaki
{"title":"Roles and Advancements of Blood Pressure Monitors in Cardiovascular Medicine","authors":"O. Shirasaki","doi":"10.4286/JJMI.80.622","DOIUrl":"https://doi.org/10.4286/JJMI.80.622","url":null,"abstract":"","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"66 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134545549","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
5.脳神経外科手術時の皮膚消毒方法に関する検討(第51回 日本医科器械学会大会 講演集) 5.脳神経外科手術時の皮膚消毒方法に関する検討(第51回 日本医科器械学会大会 講演集)
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/ikakikaigaku.46.suppl_13
岩根 幸子, 金沢 テツ, 渡辺 初江, 草地 宣美, 利治 佐々木, 植原 早苗, 羽場 史枝, 歌子 久保田, 小林 寛伊, 林 キイ子, 高橋 泰子, 都築 正和, 益沢 秀明, 三井 香児, 清水 喜八郎
{"title":"5.脳神経外科手術時の皮膚消毒方法に関する検討(第51回 日本医科器械学会大会 講演集)","authors":"岩根 幸子, 金沢 テツ, 渡辺 初江, 草地 宣美, 利治 佐々木, 植原 早苗, 羽場 史枝, 歌子 久保田, 小林 寛伊, 林 キイ子, 高橋 泰子, 都築 正和, 益沢 秀明, 三井 香児, 清水 喜八郎","doi":"10.4286/ikakikaigaku.46.suppl_13","DOIUrl":"https://doi.org/10.4286/ikakikaigaku.46.suppl_13","url":null,"abstract":"","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132835833","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development and testing of a ventilator remote adapter via communication between ventilator and receiving smart device utilizing accompanying app. 开发和测试一种呼吸机远程适配器,通过呼吸机和接收智能设备之间的通信,利用配套的应用程序。
The Japanese journal of medical instrumentation Pub Date : 1900-01-01 DOI: 10.4286/JJMI.88.449
Jun Yoshioka, Satoshi Ishiyama, Daiki Saitoh, Tomoka Nagasawa, Tomomi Matsuda, M. Hoshina, Norihiko Tsuchiya
{"title":"Development and testing of a ventilator remote adapter via communication between ventilator and receiving smart device utilizing accompanying app.","authors":"Jun Yoshioka, Satoshi Ishiyama, Daiki Saitoh, Tomoka Nagasawa, Tomomi Matsuda, M. Hoshina, Norihiko Tsuchiya","doi":"10.4286/JJMI.88.449","DOIUrl":"https://doi.org/10.4286/JJMI.88.449","url":null,"abstract":"院内で使用している人工呼吸器,人工透析装 置,人工心肺装置等の生命維持管理装置は患者 への侵襲性が高く,不具合が生じた場合には生 命の危険に直結する恐れがある.そのため,生 命維持管理装置からのアラームは,迅速に発生 場所や状況,原因を明確にする必要がある.生 命維持管理装置の一つである人工呼吸器は,医 療技術の発展によって高度化した.しかし,多 くの CPU 基板やセンサー類を搭載したため複 雑な回路構成になり,壊れ易い欠点を持つよう になった.そこで,高度化した人工呼吸器を 使用する上で更なる安全性が求められ,より徹 底した保守管理体制の構築と稼働中の換気状態 の監視が求められている.そのような中,人 工呼吸器を使用している臨床現場から離れた場 所にいる医師,看護師,臨床工学技士等の医療 従事者が遠隔より人工呼吸器を監視でき,かつ, 人工呼吸器に異常・不具合が発生した際にはリ アルタイムにアラーム内容を確認できるシステ ムが望まれている. そこで我々は,医工連携事業の一環として, 院内の無線ネットワークを利用したアラーム通 知機能を有する人工呼吸器遠隔監視システムを 地域 IT 企業と共同開発した.また,当院にお いて本システムの検証試験を実施し,評価した.","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130705672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书