{"title":"Model Adaptive Controller for Multi-Level Quasi Z-Source Inverter","authors":"G. Dhivya, P. Manoharan, M. Kumar","doi":"10.1109/ICPECTS.2018.8521642","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521642","url":null,"abstract":"The Model Reference Adaptive Controller (MRAC) is implemented for the model of nine- level Cascaded H Bridge (CHB) asymmetrical Quasi Z Source Inverter (QZSI). The proposed MRAC controller forces the output current to be sinusoidal, with low current harmonics, and to be in phase with the line voltage. The advantages of using MRAC over conventional proportional-integral control are its flexibility, adaptability, and robustness; moreover, MRAC can self-tune the controller gains to assure system stability. Since the QZSI is a non linear system, it is hard to design the controller. MRAC is simple and predict the future values of output variables using a dynamic model of the process comparing conventional PI controller. In this work, the performance of MRAC is compared with conventional PI controller based on the settling time and harmonic distortion. The simulation results clearly showed that the MRAC can lead to reduction in the settling time and harmonic distortion of the obtained output for the system. In addition to this the cascaded nine level QZSI with asymmetrical input voltage in the ratio of 1:3, whose performance is analyzed to provide a boosted output voltage and due to the asymmetrical input configuration the output voltage can be obtained with more voltage levels with lesser number of component thus lead to better outputvoltage quality with the reduction in filter size.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115013399","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
G. Jayanthi, S. Arunachalam, K. Praveen, Krishnan P S Unni
{"title":"Cost Effective SCADA for Remote Monitoring and Control for Effective Process Automation Using HMI","authors":"G. Jayanthi, S. Arunachalam, K. Praveen, Krishnan P S Unni","doi":"10.1109/ICPECTS.2018.8521608","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521608","url":null,"abstract":"The process automation is made effective and more accurate with help of automation tools like DCS/PLC and SCADA. In present the industries are moving towards INDUSTRY4.0. This in simple terms can be translated as remote control and analysis of process data. In order to provide basic control action to those working on the field a HMI is fixed to the control panel with a necessary set of switches. Thus remote sharing of data to the respective field personnel can be made much easier and simple. Since, it acts as interface medium for viewing real time process in mobile over a certain area using TP-LINK connection. And same HMI screen developed can also be used as SCADA. Thus acting as cost efficient Human Interface for small and medium scale industry who is looking for cost effective automation tool and process should have less complexity for easy implementation.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115690648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Sinha, Prasanth Ram J, Arun Kumar, N. Rajasekar
{"title":"Green Algae, Sunflower Seed and Reduced Graphene Oxide in Organic Photovoltaic Cell","authors":"P. Sinha, Prasanth Ram J, Arun Kumar, N. Rajasekar","doi":"10.1109/ICPECTS.2018.8521621","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521621","url":null,"abstract":"This paper describes about the fabrication of layer of a solar cell with organic materials. The organic materials used in this work are green algae, sunflower seed and reduced graphene oxide. It's a well- known fact that a green algae acts as an air purifier as it does photosynthesis and also there is comparative study between a full grown big tree and green algae of same volume as that of tree, it says that green algae consumes 70% more carbon dioxide than tree. Sunflower seed has tocopherols which is responsible for photosynthesis. Sunflower seed are used in flour form. Reduced Graphene Oxide is obtained by processing carbon rod which is taken from dry cell of a torch. The method involve in this to convert carbon rod into reduced graphene oxide is Modified Hummers Method. Till date different set of materials have been used to make layers of a solar cell, from silicon to metallic to combination of organic and metal compounds or elements. So making these layers involves complex processes and some of these processes are also not eco-friendly. All these processes are done to achieve one single goal of mimicking the natural process of photon trapping at bigger scale to convert light energy into electricity. So the main objectives of this work, firstly to get more or equal open circuit voltage and short circuit current as compared to other metallic compound used in making layers for solar cell, secondly to make layers of solar cell with simples organic or eco-friendly resources commonly available and can obtained easily without any complex processing of raw materials, thirdly instead of going for different complex processes just take the natural raw material and use it in its natural form to achieve the goal. This work is carried out by checking that whether the algae can give some open circuit voltage and it has been done successfully. Then by taking a beaker or glass pot and adding firstly, reduced graphene oxide, secondly, sunflower seed flour and lastly, algae in the same vessel containing algae and reduced graphene oxide. These three materials are added in different proportions to achieve greater value of open circuit voltage and short circuit current. So value ranges from 0.6V to more than 2V of open circuit voltage and more than 3mA for that short circuit current. The electrolyte used is water and if better electrolyte is used using same material then greater values can be achieved easily.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115803836","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Jithin, P. Prasanth, Vikas Gautam, V. Meheranusha, S. Kumaravel, S. Ashok
{"title":"A Sensitivity Analysis on Performance of a Typical Single Axle Battery Electric Vehicle","authors":"T. Jithin, P. Prasanth, Vikas Gautam, V. Meheranusha, S. Kumaravel, S. Ashok","doi":"10.1109/ICPECTS.2018.8521616","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521616","url":null,"abstract":"This paper outlines the sensitivity analysis of battery energy consumption for varying vehicle parameters and efficiencies of the powertrain components in a battery driven electric vehicle. The paper elucidates the calculation of energy consumption from the battery using backward calculation algorithm. The energy consumption from battery depends on a number of factors and losses at each stage has effects of varying magnitudes in the overall efficiency. The major scope of this paper is to quantify these effects based on a sensitivity analysis and to find the critical vehicle parameter and critical component in the powertrain, allowing suggestions for the improvement in performance of the battery driven electric vehicle for a lower consumption rate based on the sensitivity analysis. This aids in a significant improvement in the electric vehicle range by intelligent design of the vehicle parameters and powertrain components. The concept is analyzed for different combinations of vehicle parameters and powertrain componentefficiencies for NEDC (New European Driving Cycle) cycles. This enables additional degrees of freedom to optimize the component design for performance and cost based on application.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"132 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131507565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design and Hardware Implementation of Self Lift Negative Output Luo Converter Using MPPT for PV Applications","authors":"M. Devi, Ms. P. Abirami, M. Banu","doi":"10.1109/ICPECTS.2018.8521577","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521577","url":null,"abstract":"The design and analysis of self lift N/O luo is discussed in this paper. The incremental conductance mppt extracts the maximum power from PV panel and transfers to the load. The PV panel is designed by using equivalent circuit of PV cell. The output obtained from the solar panel contains more ripples. The ripples will produce more fluctuations. By using self lift negative output luo converter the unregulated output will be conveted into regulated voltage and stepped up to the higher voltage. For obtaining simulation results Matlab software is used.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"181 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131145741","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Lakhyadeep Rajkonwar, R.T. Arun Ram Prasath, Jasper D, N. K. Roy
{"title":"Studies on Epoxy Based TiO2Nano-filler for High Voltage Application","authors":"Lakhyadeep Rajkonwar, R.T. Arun Ram Prasath, Jasper D, N. K. Roy","doi":"10.1109/ICPECTS.2018.8521635","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521635","url":null,"abstract":"In recent years, dry transformers are playing a dominant role in electrical system. Dry type transformers mainly comprise of different types of solid insulating materials. Traditionally, epoxy based solid insulating materials are used for the purpose of insulation. In this paper, dielectric properties of epoxy resin based Titanium di-oxide (TiO2) nanocomposite is presented for the use of an alternative insulation for high voltage applications. Plain epoxy resin has been mixed with different volume fractions of TiO2nano particle to study the properties of AC breakdown voltage (BDV). The AC breakdown voltage test was performed in oil medium at room pressure and temperature as on the lines of ASTM standard. It is observed that addition of nano particle to plain epoxy enhances the breakdown voltage with increase in volume fractions of TiO2nanofiller. BDV of 0.03% volume fraction sample shows the maximum enhancement of breakdown voltage. Therefore, nano-filler based solid dielectric will be an alternative to conventionally used solid dielectrics for compact design of HV power apparatus.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121199470","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electrifying Villages Using Microgrids","authors":"C. Nayanathara, Srilatha R","doi":"10.1109/ICPECTS.2018.8521612","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521612","url":null,"abstract":"According to a recent survey by the Rural Electrification Corporation Limited, there are a total of 18,000 villages in India that have no access to electricity. These villages cannot be easily connected to the main grid as they are much far away from the centralized grids. This requires transmitting power through very large distances. The concepts of microgrids have been prevailing for a while in the energy industry. A microgrid is a localized group of energy resources that has the ability to support a set of defined loads and are connected with the centralized grid. But, the microgrids can also be operated with or without the support of the main centralized grid. In this work, the concept of microgrids was studied to electrify these villages which can work independently just like the main grid but by using distributed and cleaner energy resources such as the solar energy. It was found that the cost of constructing a microgrid was roughly three times cheaper than bringing power from the centralized main grid. Even though some of the villages are continually being electrified by the Indian Government, there are still many villages left that are impossible to be powered by connecting with the grid.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116968703","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power Line Commnuication -A Smart Approach for Efficient Data Transmission","authors":"S. Varunkumar","doi":"10.1109/ICPECTS.2018.8521571","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521571","url":null,"abstract":"In a rapidly changing world new technological advancements and improvements are a constant need and in the field of communication and data transmission the necessity of a new technology is a need of the hour. The Power Line Communications (PLC) is one such technology described in this paper which allows transmission of data over existing power lines. Since power lines are almost ubiquitous this technology could have a rapidly emerging market, utilizing existing electricity power lines for high speed transmission of data and voice servers. This method could possibly be seen as a new approach for home automation and for data transmission within industries internally and externally.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127253681","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Neoteric Approach Towards Anxiety Quantification by EEG Signal Analysis","authors":"M. J. Mary Juliana, N. Rangaswamy","doi":"10.1109/ICPECTS.2018.8521562","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521562","url":null,"abstract":"Anxiety has become a moiety of day today life for many, an inseparable complement of every endeavor. This serves as a fountain head of several complications and health hazards. Anxiety causes various changes in the body of which those reflected by the Central Nervous System (CNS) are predominant. This paper focuses on the exhaustive analysis of the electroencephalogram (EEG) signal concerning anxiety quantification. The signals are taken from various databases of which the MIT-BIH and Physionet databases are worth mentioning, then four chosen classification algorithms namely, KNN, QDA, LDA and D Tree respectively are applied, the Principle Component Analysis is utilized as the feature classification tool and the spectral characteristics of the sub bands are studied. Lastly the FFT is applied to the raw EEG to perform its frequency domain analysis and anxiety is thus detected in PC using MATLAB as the tool.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126829640","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Field Testing and Analysis of Stray Current Interference on Gas Pipeline from Metro Maintenance Base","authors":"Chen Zhiguang, Zhang Xuyan, Qin Chaokui","doi":"10.1109/ICPECTS.2018.8521575","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521575","url":null,"abstract":"Stray current generated from the rail transit system will cause serious corrosion to the nearby buried gas pipelines. With the development of rail transportation and gas industry, stray current corrosion of gas pipelines is becoming more serious. Existing test research mainly focus on the rail transit line station, stray current interference from the metro depot and maintenance base does not see more. In this paper, a gas pipeline near Shanghai rail transit base has been chosen as the research object, the gas pipeline potential, soil potential gradient, and rail potential have been tested, the stray current interference intensity and flow direction in the soil have been analyzed. Results show that, the tested gas pipeline is in danger of serious stray current corrosion. The average positive deviation of the pipe-to-soil potential during the subway operation is about 0.5V, while the fluctuation range of the soil potential gradient is - 10mV/m~15mV/m. The current in soil flow into the rail in metro maintenance base while the rail-to-soil potential is negative, which is consistent with the operation of rail transit.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129788025","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}