{"title":"Speed Control of Single and Three Phase Induction Motor Using Full Bridge Cycloconverter","authors":"B. Brindha, T. Porselvi, R. Ilayaraja","doi":"10.1109/ICPECTS.2018.8521626","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521626","url":null,"abstract":"This project proposes a full bridge cyclo-converter for three and single-phase induction motor speed control. The speed control of Induction Motor is simple and can be made efficient by using various methods to control the action of Cyclo-converter which will control the motor performance. There are two ways to control the speed of the motor, one method is by changing the frequency and the second method is by changing the number of poles. The speed control by the second method is uneconomical because under running conditions the number of poles can't be varied and the machine size becomes bulkier, but the problems can be overcome by the first method. In this scheme, the motor supply frequency can be varied in running conditions, so it will not change the motor size. In this scheme, the Cyclo-converter is a frequency changing device. It is a power electronic device used to convert constant frequency constant voltage AC power to adjustable frequency adjustable voltage. AC power is used without a DC link. Among all the schemes the frequency method is reliable, simple and economical. By using Cyclo converter the various speed of induction motor is obtained. The merits of proposed bridge type cyclo converter for speed control of single and three phase induction motor is verified by simulations in MATLAB/Simulink environment.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"51 32","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120839744","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Simultaneous Multiple DG and Capacitor Installation Using Dragonfly Algorithm for Loss Reduction and Loadability Improvement in Distribution System","authors":"R. Arulraj, N. Kumarappan","doi":"10.1109/ICPECTS.2018.8521605","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521605","url":null,"abstract":"Insufficient reactive power generation has major impact on power loss, voltage stability margin (VSM) and maximum loadability of electric distribution system. In this paper optimal separate as well as simultaneous multiple installation of DG and capacitor are presented to solve these issues, which alters system reactive power flow, thereby having positive influence on system parameters. Minimization of total reactive power loss (QL) is taken as the main objective and the optimization problem is solved using a swarm intelligence based optimization algorithm called dragonfly algorithm (DA). The proposed methodology is studied using standard 33-bus distribution systems. Results demonstrate the effectiveness of DG and capacitor in minimizing QL, thereby enhancing VSM and loadability of distribution system. The efficiency of the proposed technique is also demonstrated by comparing the results with other optimization techniques.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121147458","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"IoT Enabled Coherent Detritus Management","authors":"G. Balasubramanian, S. Sridhar, A. Ramamurthy","doi":"10.1109/ICPECTS.2018.8521569","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521569","url":null,"abstract":"Technology has reached and has modified and manipulated almost every part of us human beings. But technology seems to lag behind in developing and enhancing the waste disposal system. The waste disposal system is very ancient and outdated. As a result, the nation lags behind in waste recycling and management system, while countries like Denmark have achieved perfection to an extent such that it has begun importing waste from other countries to keep their recycle plants running. Hence this paper is aimed at modifying one significant part of waste management that can prove to improve the efficiency of waste management. Usually, the Waste Trucks will scavenge streets after garbage bins and will collect the waste. But this happens at irregular time periods. Sometimes a road is visited after the Bin overflows with garbage and a complaint is raised to the corporation. This has a lot of disadvantages as wastes are not properly managed, the bins overflow with scraps and litter the surroundings; traffic ensures as the truck blocks the road at random times. To combat this issue, we propose an idea where we enhance the waste bins by featuring it with a level indicating sensor integrated to the internet using Wi-Fi Module. The whole setup is connected to a central microcontroller. Likewise, all the Bins in an area are given the similar configuration, and these are interconnected wirelessly. Each area is distinguished and is given a separate new identification in the ‘Coordination Controller.’ This is a web portal designed precisely where all the data of the bins are accumulated online in this portal. So by a pre-fed algorithm, the Coordination Controller will be able to determine which area needs immediate attention. The trucks will be fitted with a GPS sensor, and an App-enabled PDA will be handed to the driver. So when an area needs immediate attention, the nearby truck is notified immediately. The algorithm prioritizes areas on a basis like Schools; Hospitals are given high priority, while the less critical areais given least priority. It will be able to analyze which area requires regular attention based on the history and will provide it with a high priority. So if a particular area has a maximum waste generation, based on a pattern that area will be offered primary priority. So when the level of a bin reaches a maximum, it'll be immediately reported through the Coordination Controller to the nearby truck and that particular containeris emptied. This method is Simple, Cheap and easy to implement. This will benefit over the older process in many ways. The wastes are managed efficiently, regular collection ensures. Littering and overflow of waste is prevented. Schools and Hospital areas can be kept clean. An Arduino UNO Microcontroller, Wi-Fi Module and the level sensor will be able to change the way Waste is managed.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114143418","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Selvakumar, T. Sourabi Krishna, B. Surendaran, K. P. Hariharasudhan
{"title":"Artificial Re-Fueling System Using PLC","authors":"T. Selvakumar, T. Sourabi Krishna, B. Surendaran, K. P. Hariharasudhan","doi":"10.1109/ICPECTS.2018.8521647","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521647","url":null,"abstract":"The conventional re-fueling stations consume a lot of man power and low degree of accuracy making the overall experience as an unpleasant one. The project aims to enhance the gasoline filling experience at a vendor more pleasant and accurate one. The Automated Re-fueling Station (ARS) is implementing programmable logic controllers in making this a reality. Today, automation engulfs all science fields making everything simple and easily approachable. The idea of ARS sparked due to the events like inaccuracy in filling the tank and malpractices involved in it.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128400522","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modern Electric Engine for Future Cars","authors":"T. Selvakumar, S. Karthik, S. A. Kumar","doi":"10.1109/ICPECTS.2018.8521629","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521629","url":null,"abstract":"In today World, majority of the population use Fuel dependent vehicles. Parallel to current scenario, the demand for Fuel is also keeps growing day by day. On such issue, we could replace the existing engine with Hybrid Engine. It could run by both Electrical and Fuel modes of operation. In Electrical mode, A supply of 36V DC is given for excitation of temporary magnet which is fixed over engine and piston. Thereby the piston works by attraction and repulsion process. The excitation in turned off when the engine is switched to Fuel mode where is works as the concept of the as Internal Combustion Engine (IC engine).","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"89 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129038310","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Solid State Transfomer Based Wind Energy Conversion System","authors":"A. Ambika, K. Gayathri, T. Iswarya, S. Malarvizhi","doi":"10.1109/ICPECTS.2018.8521624","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521624","url":null,"abstract":"The impact of renewable energy integration into the power system resulted in wind power as one of the emergingtechnology in the present scheme. This paper focuses on Solid State Transformer (SST) based wind system. Itaims to attain voltagetransmissionfromintermediate to high frequencyisolation, therefrom to enable reduced volume architecture as compared with the conventionaltransformer. A combined configuration of doubly fed induction generatorand SST operation is proposed hereto achieve the active power compensation in the wind system [4].","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"12 9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121565828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Dhandayuthapani, R. Mohanapriya, C. Sharmeela, E. Kanimozhi
{"title":"FOPID Controlled Shunt Active Filter in IEEE Nine Bus System with Improved Dynamic Time Response","authors":"S. Dhandayuthapani, R. Mohanapriya, C. Sharmeela, E. Kanimozhi","doi":"10.1109/ICPECTS.2018.8521561","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521561","url":null,"abstract":"This paper investigates a Fractional Order Proportional Integral Differential controlled Shunt active filter for a Wind Energy Conversion Systems(WECS) connected to IEEE Nine bus system to enhance its dynamic response. The SAF is constructed with Voltage Source Inverter and proposed FOPID controller is used to generate the switching pulses. Simulation results of PI and FOPID controller based SAF are compared and the corresponding time domain parameters are validated. It is shown that proposed FOPID active filter is increase the system performance through simulation.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126322281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Lavanya, Samvirt Ji Kanwar, A. K. Nanda, M. Ravikiran, P. L. Bora
{"title":"Design, Development and Performance Evaluation of Automated Relay Controller for Solenoid Valve Operation During Static Test of Rocket Motors","authors":"D. Lavanya, Samvirt Ji Kanwar, A. K. Nanda, M. Ravikiran, P. L. Bora","doi":"10.1109/ICPECTS.2018.8521634","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521634","url":null,"abstract":"This paper presents the design and development of an automated relay controller for pulse mode operation of solenoid valves for switching on / off the propellant flow to the combustion chamber of a thruster during static test. This paper enumerates the design of multi-channel solenoid valve controller using electro-mechanical relays operated through microcontroller. Two application software have been developed for automation purpose - one for simultaneous operation of multiple solenoid valves, as per required pulse sequence, developed in embedded C language and the other for configuration of the system, developed in MATLAB with a GUI. The performance of the designed system has been evaluated through various tests carried out in lab, field and during static tests.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"147 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132690641","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Direct Energy Transfer Technique Based DC-DC Converter with Distributed MPPT for PV Charging Applications","authors":"K. V. Kumar, C. Vyjayanthi","doi":"10.1109/ICPECTS.2018.8521633","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521633","url":null,"abstract":"The solar based charging systems depend on factors like irradiance, temperature, MPPT tracker, etc. Its performance can be improvised by selecting appropriate converter topologies and system's design specifications. While analyzing the Solar irradiance pattern, both uniform and nonuniform (partial) shading conditions need to be considered. Normally, by-pass diodes are used in anti-parallel to the module or panel to protect it from the hot spot effect. Due to partial shading conditions, multiple local Maximum Power Points (MPP's) occur in the Power-Voltage graph, because of by-pass diodes, and only one among them is the global MPP. For best operation of PV, it is to be operated at global MPP. But, at the global MPP, the partial shaded modules/panels are unable to produce the maximum power. To utilize the power produced by each panel/module efficiently, distributed MPPT is used; where each converter is connected to a module/panel and operated at their local MPP's and the output of the converters are connected in series or parallel to meet the desired voltage and current levels respectively. This paper presents the performance of a system under uniform and non-uniform irradiance conditions analyzing stress on the converter and overall system efficiency for conventional Buck-Boost and direct energy transfer based technique with distributed MPPT for PV charging applications. The simulation is carried out using MATLAB/Simulink, and results are presented.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116987807","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of Controllers for DC-DC Boost Converter","authors":"S. Padhmanabhaiyappan, R. Karthik, K. Ayyar","doi":"10.1109/ICPECTS.2018.8521643","DOIUrl":"https://doi.org/10.1109/ICPECTS.2018.8521643","url":null,"abstract":"The DC-DC boost converter has the most desirable features such as high efficiency, high power density, high reliability and low EMI. In this paper a comprehensive review of the control schemes used in the power electronic converters was presented. The linearization of control output transfer function of Boost converter and the various performances of controllers include rise time, peak time, overshoot and settling time are investigated. The controllers of PI, PID, PR, and PIR controllers are designed by the step response of Ziegler - Nichols tuning rule and investigation of parameters Kp, Ti, Td as to contrivance the boost converter. Comparison of response of controllers is provided.","PeriodicalId":220180,"journal":{"name":"2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128872372","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}