Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage最新文献

筛选
英文 中文
The Design of a Small-Scale Pumped Heat Energy Storage System for the Demonstration of Controls and Operability 小型抽水蓄能系统的设计及可操作性论证
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-83424
N. Smith, B. Tom, Aaron M. Rimpel, Joshua Just, Michael Marshall, George N. Khawly, Thomas Revak, K. Hoopes
{"title":"The Design of a Small-Scale Pumped Heat Energy Storage System for the Demonstration of Controls and Operability","authors":"N. Smith, B. Tom, Aaron M. Rimpel, Joshua Just, Michael Marshall, George N. Khawly, Thomas Revak, K. Hoopes","doi":"10.1115/gt2022-83424","DOIUrl":"https://doi.org/10.1115/gt2022-83424","url":null,"abstract":"\u0000 Long-duration, grid-scale energy storage technologies provide a potential pathway to enable the full penetration of renewables into the electricity grid while still maintaining grid reliability and security. Among these technologies, pumped heat energy storage (PHES) stores energy thermally using a heat pump and discharges that stored thermal energy with a heat engine when needed. With high potential system performance, implementation versatility, and no geological and geographical constraints, PHES is a promising technology. While PHES leverages many existing component technologies, no air-based PHES system has been built and demonstrated and the path to commercialization requires intermediate demonstration. This paper summarizes the design of a PHES system with the purpose of demonstrating operation and verifying control strategies of a closed air Brayton PHES at lab scale. With lower temperatures and smaller machinery, this facility will provide better understanding of operational limitations, discover first implementation challenges, and reduce risk for the full-scale system. This paper presents the challenges associated with cycle design using off-the-shelf hardware, and how that lead to the development of custom machinery including the turbine aerodynamic flowpath and nearly all mechanical design of the turbocompressors. Finally, cycle analysis updates with as-built hardware and transient modelling are presented. The subject design effort resulted in a simple recuperated lab-scale PHES with three heat exchangers shared between charge and discharge mode and two turbocompressor drivetrains, one for each operation mode. At design point, the system is predicted to have 10% round trip efficiency, generate 5 kW with 1 hr of storage.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115413153","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimization Under Uncertainties of a Biogas-Fueled SOFC-GT Hybrid System 沼气燃料SOFC-GT混合动力系统的不确定优化
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-81785
Paolo Finocchi, V. Zaccaria, M. L. Ferrari, David Tucker
{"title":"Optimization Under Uncertainties of a Biogas-Fueled SOFC-GT Hybrid System","authors":"Paolo Finocchi, V. Zaccaria, M. L. Ferrari, David Tucker","doi":"10.1115/gt2022-81785","DOIUrl":"https://doi.org/10.1115/gt2022-81785","url":null,"abstract":"\u0000 SOFC-GT hybrid systems can be a good solution for small-medium size applications of distributed generation thanks to their high efficiency and their high fuel flexibility. Fueling these systems with raw biogas coming from biomass gasification makes them also completely renewable, but it introduces a high variability of performance due to the syngas composition fluctuations. For this reason, this work pursues the aim of realizing a robust system optimization, necessary to obtain the best design and ensure high efficiency combined with low variability. To do this, a co-flow, planar, anode supported SOFC Simulink model was used. Moreover, a related surrogate model was created to decrease the computational time and increase exponentially the number of simulations. To calculate the robust optimum design, the Monte Carlo method was used, simulating the syngas composition distribution with 2000 points and to the operating envelope with 5000 input combinations. Mean value and standard deviation in system efficiency were used to select a Pareto front. The robust points turned out to be those with low electric load, small-medium pressure, and high temperature, while maximum efficiency points were characterized by higher pressure levels. The smaller standard deviation at lower pressure was shown to be linked to the bottoming cycle operation and in particular to the gas turbine off-design condition. This difference between the two design conditions (robust optimum and efficiency optimum) confirmed the importance of this optimization process and the influence of fuel composition on system performance.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128713975","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Micro-Gas Turbine Cycle Configurations for Biomass Combined Heat and Power Plants 生物质热电联产电厂微型燃气轮机循环配置
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-80772
K. Bollas, T. Efstathiadis, D. Mertzis, A. Kalfas
{"title":"Micro-Gas Turbine Cycle Configurations for Biomass Combined Heat and Power Plants","authors":"K. Bollas, T. Efstathiadis, D. Mertzis, A. Kalfas","doi":"10.1115/gt2022-80772","DOIUrl":"https://doi.org/10.1115/gt2022-80772","url":null,"abstract":"\u0000 The potential of integrating micro-gas turbine systems into biomass micro-Combined Heat and Power (CHP) units is investigated, following a thermodynamic analysis. Various cycle configurations are elaborated, utilising the producer gas of an existing biomass gasification CHP unit, with a capacity of 30 kWe. The reference CHP unit consists of a fluidised bed gasifier coupled with a gas treatment unit, a gas cooler and an Internal Combustion Engine (ICE). The gas cooler operation is entailed with environmental issues, concerning tar condensation and removal. In this paper, alternative approaches of direct fuel combustion, at elevated temperatures, through micro-gas turbine systems are investigated. Five configurations, based on the internally-fired (simple and recuperative μ-GT) or the externally-fired gas turbine (μ-EFGT), as well an additional reheated micro-gas turbine (μ-RHGT) are considered. The μ-EFGT is investigated for two cases: unfiltered (UF) and filtered (F) producer gas fuel. Each configuration is optimised, using in-house solvers, while the components are modelled using turbomachinery and heat exchanger detailed designs. The recuperative μ-rGT and the unfiltered μ-EFGT/UF show a similar electrical efficiency of around 31.5%, while the overall efficiencies are 63% and 74.8% respectively, which is improved by 5%, compared to the ICE. Challenges related to fuel compression, mainly due to the high rotational speed, are expected in the μ-rGT case, while fouling is expected to be a serious challenge in the μ-EFGT/UF case. Both challenges can be addressed by the filtered μ-EFGT, however, this results in lower electrical efficiency, around 26.5%, which is −12% compared to the ICE.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130853284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical Investigation on Regenerative Heat-Driven Cryocoolers for Zero Boil-Off Storage of Liquid Hydrogen 蓄热式液氢零蒸发储存制冷机的数值研究
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-81737
Jing Luo, Yanyan Chen, Limin Zhang, V. Sankar, D. Prabhudharwadkar, S. Saxena, D. Lacoste, W. Roberts, E. Luo
{"title":"Numerical Investigation on Regenerative Heat-Driven Cryocoolers for Zero Boil-Off Storage of Liquid Hydrogen","authors":"Jing Luo, Yanyan Chen, Limin Zhang, V. Sankar, D. Prabhudharwadkar, S. Saxena, D. Lacoste, W. Roberts, E. Luo","doi":"10.1115/gt2022-81737","DOIUrl":"https://doi.org/10.1115/gt2022-81737","url":null,"abstract":"\u0000 Aiming at the zero boil-off demand of liquid hydrogen storage tank, this paper uses SAGE software to design and simulate 300 W @ 20 K regenerative heat-driven cryocoolers, verifying the principle feasibility of duplex free-piston Stirling cryocooler and thermoacoustic heat-driven pulse tube cryocooler for the zero boil-off storage of liquid hydrogen. The results show that under the design conditions of mean pressure of 5 MPa, the operating frequency of 50 Hz, the heating temperature of 500°C, and ambient temperature of 30°C, the exergy efficiency of the duplex free-piston Stirling cryocooler can reach 19.4%, while the exergy efficiency of the thermoacoustic heat-driven pulse tube cryocooler is 14.3%. However, because a fixed-parameter harmonic oscillator is used to couple the engine and the cryocooler in the duplex free-piston Stirling cryocooler, it is difficult to achieve multi-condition matching, which makes it very sensitive to changes in operating parameters such as mean pressure and heating temperature. In contrast, the thermoacoustic heat-driven pulse tube cryocooler is completely free of moving parts and has excellent adaptability to the operating conditions. Therefore, the thermoacoustic heat-driven pulse tube cryocooler may be a promising solution in the application field of zero boil-off storage of liquid hydrogen.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134450284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Part-Load of Steam Rankine Cycles for Solar Salts-Based Concentrating Solar Power Plants 太阳能盐基聚光太阳能电站蒸汽朗肯循环部分负荷研究
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-79378
Davide Belverato, E. Martelli, M. Binotti, L. Pilotti, A. Giaconia
{"title":"Part-Load of Steam Rankine Cycles for Solar Salts-Based Concentrating Solar Power Plants","authors":"Davide Belverato, E. Martelli, M. Binotti, L. Pilotti, A. Giaconia","doi":"10.1115/gt2022-79378","DOIUrl":"https://doi.org/10.1115/gt2022-79378","url":null,"abstract":"\u0000 This work proposes two ad hoc part-load control strategies for steam cycles adopted in concentrated solar power plants. The control strategies are designed to keep the molten salt temperature above the minimum allowed value set by solidification issues in the 30–100 % load range. Particularly critical is the temperature of molten salts in contact with the heat exchanger tubes, the so called skin temperature. The first control strategy adopts a turbine with controlled extraction and readmission valve while the second strategy employs a throttling valve and a feedwater preheating loop. Off-design simulations show that both strategies are capable of avoiding the molten salts solidification issue but at the cost of a non negligible penalty (up to −1.9 percentage points) in power block efficiency at low loads (30–50%). The off-design analysis considers also the effect of ambient temperature variations and the optimization of the cooling fan rotational speed. The results are used to derive best-fit polymonials relating the power block efficiency to the ambient temperature and load.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124916062","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Gas Turbine Combined Cycle Range Enhancer - Part 1: Cyber-Physical Setup 燃气轮机联合循环范围增强器。第1部分:网络物理设置
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-82494
T. Reboli, M. Ferrando, L. Mantelli, Lorenzo Gini, A. Sorce, J. Garcia, R. Guédez
{"title":"Gas Turbine Combined Cycle Range Enhancer - Part 1: Cyber-Physical Setup","authors":"T. Reboli, M. Ferrando, L. Mantelli, Lorenzo Gini, A. Sorce, J. Garcia, R. Guédez","doi":"10.1115/gt2022-82494","DOIUrl":"https://doi.org/10.1115/gt2022-82494","url":null,"abstract":"\u0000 Natural gas turbine combined cycles (GTCCs) are playing a fundamental role in the current energy transition phase towards sustainable power generation. The competitiveness of a GTCC in future electrical networks will thus be firmly related to its capability of successfully compensating the discontinuous power demands. This can be made possible by enhancing power generation flexibility and extending the operative range of the plant.\u0000 To achieve this goal, a test rig to investigate gas turbine inlet conditioning techniques was developed at the TPG laboratory of the University of Genoa, Italy. The plant is composed of three key hardware components: a micro gas turbine, a butane-based heat pump, and a phase-change material cold thermal energy storage system. The physical test-rig is virtually scaled up through a cyber-physical approach, to emulate a full scale integrated system.\u0000 The day-ahead schedule of the plant is determined by a high-level controller referring to the Italian energy market, considering fluctuations in power demands.\u0000 By using HP and TES, it is possible to control the mGT inlet air temperature and thus enhance the operational range of the plant optimizing the management of energy flows.\u0000 This article (Part 1) introduces the new experimental facility, the real-time bottoming cycle dynamic model, and the four-level control system that regulates the operation of the whole cyber-physical plant. The experimental campaign and the analysis of the system performance are presented in the Part 2.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128621945","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Liquid Salt Combined Cycle 液盐联合循环
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-82343
W. Conlon, Milton Venetos, S. Hume
{"title":"Liquid Salt Combined Cycle","authors":"W. Conlon, Milton Venetos, S. Hume","doi":"10.1115/gt2022-82343","DOIUrl":"https://doi.org/10.1115/gt2022-82343","url":null,"abstract":"\u0000 The Liquid Salt Combined Cycle™ (LSCC) is introduced as a hybrid energy storage system that integrates electrically heated thermal energy storage with gas turbine exhaust heat. The objective is to provide low-cost, large-scale storage of increasingly curtailed renewable energy, and to use the stored energy to reduce the fuel heat rate of the combined cycle and the time required from startup to full power. The performance, capital, and operating characteristics of a hybrid storage system using two energy sources are contrasted with thermal generation using a fuel source and with energy storage using an electric source. These characteristics are mapped onto LSCC technology, which is depicted with a diagram showing the flow of electricity into storage during charging, the flow of stored thermal energy during discharge. Stored energy provides latent heating of steam and fuel energy drives a gas turbine whose exhaust gas provides sensible heating of feedwater and superheated steam. A description of the major LSCC equipment is provided: turbomachinery, two-tank molten salt storage, charge heaters, steam generator, exhaust heat recovery, and condensate heating. Material selection and thermal design of LSCC are summarized and performance is compared to simple and combined cycle. The Cost of Energy and Avoided Cost of Energy are assessed for a hypothetical LSCC unit within the ERCOT region.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"252 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133713464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Compressor Surge Precursors for a Turbocharger Coupled to a Pressure Vessel 与压力容器耦合的涡轮增压器的压气机喘振前兆
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-81731
P. Silvestri, F. Reggio, Carlo Alberto Niccolini Marmont Du Haut Champ, M. L. Ferrari, A. Massardo
{"title":"Compressor Surge Precursors for a Turbocharger Coupled to a Pressure Vessel","authors":"P. Silvestri, F. Reggio, Carlo Alberto Niccolini Marmont Du Haut Champ, M. L. Ferrari, A. Massardo","doi":"10.1115/gt2022-81731","DOIUrl":"https://doi.org/10.1115/gt2022-81731","url":null,"abstract":"\u0000 Dynamic compressors operating region is mainly constrained by fluid-dynamic instabilities occurring at low mass flow rate conditions, such as surge and rotating stall. This work presents a vibro-acoustic experimental investigation on a centrifugal compressor of an automotive turbocharger aimed to identify and confirm some surge precursor values in correspondence of its inception conditions. The experimental campaign was carried out at the University of Genoa and developed on a vaneless diffuser turbocharger exploited for the pressurization of an innovative solid oxide fuel cell (SOFC) emulator. The investigated turbocharger is coupled with a pressure vessel for a former emulation activity on a pressurized SOFC. In this kind of plants, the joint effect of large volume size downstream of the compressor makes more complex the dynamic behavior of the whole system during transients, thus significantly increasing surge onset risk.\u0000 The activity The main goal is to obtain a suitable quantitative indicator capable to detect in advance surge inception by relying only on vibrational and acoustic system response. Several transient operations starting from a compressor stable condition to surge instability onset were performed at different initial rotating speeds by progressively closing specific valves in the air line. When moving close to the surge line, vibro acoustic signals were acquired at a high sampling rate to detect variations in compressor blade passage phenomena due to possible interactions with rotating stall inception. Meanwhile, the trend of pressures, temperatures and mass flow rates measured in specific plant sections were acquired at a lower sampling rate to obtain a link between the compressor vibro-acoustic and performance behavior. Cyclostationary analysis and Several post-processing methods in time, angle and frequency domains were performed on microphone and accelerometer acquired signals to provide innovative diagnostic and predictive solutions (precursors) able to warn the incoming of surge compressor instability with cheap and not intrusive sensors like microphones and accelerometers.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"10 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132507612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Exergy Analysis of Green Power-to-Hydrogen Chemical Energy Storage 绿色电力制氢化学储能的能量分析
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-82107
Antonio Escamilla, D. Sánchez, L. García-Rodríguez
{"title":"Exergy Analysis of Green Power-to-Hydrogen Chemical Energy Storage","authors":"Antonio Escamilla, D. Sánchez, L. García-Rodríguez","doi":"10.1115/gt2022-82107","DOIUrl":"https://doi.org/10.1115/gt2022-82107","url":null,"abstract":"\u0000 Power-to-Hydrogen-to-Power are chemical energy storage systems that store surplus renewable energy in the form of hydrogen, through water electrolysis, for its later use as power when power demand rises again. Due to the very low energy and mass density of H2 at standard conditions, 0.083 kg/m3, compression of hydrogen to pressures as high as 900 bar is usually performed for storage. This is why variations in the operating conditions of the electrolyzers lead to significantly different operating conditions of the hydrogen compression system. Accordingly, a detailed thermodynamic analysis is required to identify the individual contributions of each component to the total exergy losses: a proton-exchange membrane electrolyser, and a volumetric compressor. As expected, the volumetric compressor shows the largest improvement when switching from single stage compression to multistage intercooled compression; in particular, moving from single adiabatic compression to four compression stages with intercooling enables an exergy efficiency improvement of more than ≈20 %. On the other hand, the study reveals that optimizing the operating temperature and pressure of the electrolyzer can lead to compression exergy efficiency gains of ≈5 % when the operating temperature of the electrolyser is reduced from 352.15 K to 313.15 K and ≈25 % when the corresponding pressure increases from 1bar to 30 bar. On the contrary, reducing the operating temperature of the electrolyzer would lead to an increase in the power requirements to split the water molecule, thereby reducing the overall exergy efficiency of the system by ≈2 %.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131167782","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance Assessment of a Recuperated Turboshaft Engine: A Multifuel Case 多燃料情况下的回热式涡轮轴发动机性能评价
Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage Pub Date : 2022-06-13 DOI: 10.1115/gt2022-80455
Jody Anfossi, J. Al-Zaili, Tala El Samad, A. Sayma
{"title":"Performance Assessment of a Recuperated Turboshaft Engine: A Multifuel Case","authors":"Jody Anfossi, J. Al-Zaili, Tala El Samad, A. Sayma","doi":"10.1115/gt2022-80455","DOIUrl":"https://doi.org/10.1115/gt2022-80455","url":null,"abstract":"\u0000 The low cycle efficiency of simple cycle micro gas turbines is typically raised by the use of recuperators. The recuperated cycle allows for improved efficiency at low power-to-weight ratio, mainly due to the weight of the added heat exchanger. As weight is considered to be a key parameter for aeroengines, an analysis that addresses benefits and drawbacks of a more efficient, but heavier propulsion system design is required to be carried out. This paper assesses propulsion systems based on simple and recuperated cycle small gas turbine configurations, unusual in aviation, running with conventional jet fuel or hydrogen. An analytical model capable of modelling a turboshaft engine steady state design and off-design operation is developed. The specific fuel consumption of different engine arrangements is therefore calculated to evaluate the performance trade-off between the improved power plant fuel economy and its larger weight under a generic reference mission for a light helicopter. To enable a consistent mission analysis study of the hydrogen fueled rotorcraft, the weight of the tanks for liquid hydrogen storage is estimated according to a preliminary design model. The results obtained suggest that a hydrogen-fueled recuperated powerplant can shorten the flight time to reach the breakeven point, compared to a recuperated jet fuel powerplant of the same power rating.","PeriodicalId":217779,"journal":{"name":"Volume 4: Cycle Innovations; Cycle Innovations: Energy Storage","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127667883","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书